| 1 | Providing and fixing of Pipe 3/8” or ¼” MOC-PVC Good grade/odourless material Make:- Astral/Ashirvad/Prince or equivalent etc. As per direction of Engineer in charge. |
| 2 | Providing and fixing of 40\"\"x40\"\" Membrane-Dia- 4\"\" for 500 ltr/hr capacity, Make ofDow filmtec/ Hydronautics etc As per direction of Engineer in charge. |
| 3 | Providing and fixing of 40x40 Membrane Housing (Dia- 5\"\") for 500 ltr/hr capacity, Make ofDow filmtec/ Hydronautics etc As per direction of Engineer in charge. |
| 4 | Providing and fixing of 13x54 Vessel, Make ofDow filmtec/ Hydronautics etc As per direction of Engineer in charge. |
| 5 | Providing and fixing ofMulti Port Valve 25 mb |
| 6 | Providing and fixing ofSS 500/250 LPH Frame |
| 7 | Providing and fixing of Micron filter Housing Length- 20\"\", Dia-3\"\",Make offilmtec/ Hydronautics etc As per direction of Engineer in charge. |
| 8 | Providing and fixing of Micron filter Candle Length- 20\"\", Dia-2.5\"\", MOC- MOC-PolypropyleneMake offilmtec/ Hydronautics etc As per direction of Engineer in charge. |
| 9 | Providing and fixing of Digital Pannel 250/500 LPH Size- 18\"\"x12\"\",As per direction of Engineer in charge. |
| 10 | Providing and fixing of 2/11 HP PUMP,Make- luvi, As per direction of Engineer in charge. |
| 11 | Providing and fixing of 1 HP CRI PUMP, As per direction of Engineer in charge. |
| 12 | Providing and fixing of Rota Meter (Square) Capacity- 1200 LPH For waste water, As per direction of Engineer in charge. |
| 13 | Providing and fixing of Flow Meter (Square) Capacity- 600 LPH For Product water, As per direction of Engineer in charge. |
| 14 | Providing and fixing of Pressure Gauge Meter (on Top/Vertical type) Output-100 PSI, Make ofEdose/Milton/Pentair/ hightech/Dow filmtec/ Hydronautics etc As per direction of Engineer in charge. |
| 15 | Providing and fixing of Pressure Gauge Meter (on Back side/Horizontal type) Output-300 PSI, Make ofEdose/Milton/Pentair/ hightech/Dow filmtec/ Hydronautics etc As per direction of Engineer in charge. |
| 16 | Providing and fixing of Stainer pipe (Riser Pipe) Dia- 1\"\", Length- 54\"\" MOC- UPVC, As per direction of Engineer in charge. |
| 17 | Providing and fixing of 1/4 Pressure Gauge Meter Connector As per direction of Engineer in charge. |
| 18 | Providing and fixing of 1/4 15mm Connector As per direction of Engineer in charge. |
| 19 | Providing and fixing of 1/4 15mm Top pressure gauge meter Connector As per direction of Engineer in charge. |
| 20 | Providing and fixing of TDS Adjuster As per direction of Engineer in charge. |
| 21 | Providing and fixing of UF Membrane, As per direction of Engineer in charge. |
| 22 | Providing and fixing of Dosing pump E-Dose, As per direction of Engineer in charge. |
| 23 | Providing and fixing of U.V Complete set (Housing, Lamp, Choke) Length- 12\"\" for 500LPH ROMake-ATZ/Sealux/Kemflo/Eqvt. , As per direction of Engineer in charge. |
| 24 | Providing and Filling of Anti scalent Superior in Quality Make of Rokleewn/chemiro/scale checck or Equivalent etc. As per Direction of Engineer in charge. |
| 25 | Providing and Filling of Membrane wash cleaner Superior in Quality Make of chemiro/scale checck or Equivalent etc. As per Direction of Engineer in charge. |
| 26 | Repairing/Re-winding of 2 HP Pump, As per direction of Engineer in charge. |
| 27 | Providing and Fixing of15 MM Ball valve, As per direction of Engineer in charge. |
| 28 | Providing and fixing UPVC pipe line, having thermal stability for hot & cold water supply including all PVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 15 mm nominal outer dia Pipes |
| 29 | Providing and fixing UPVC pipe line, having thermal stability for hot & cold water supply including all PVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia Pipes |
| 30 | Providing and fixing UPVC pipe line, having thermal stability for hot & cold water supply including all PVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes |
| 31 | Providing and fixingPVC Gate valve line 15mm , Make of Astral/Ashirvad/Prayag or equivalent etc. As per direction of Engineer in charge. |
| 32 | Providing and fixingPVC Gate valve line 20mm , Make of Astral/Ashirvad/Prayag or equivalent etc. As per direction of Engineer in charge. |
| 33 | Providing and fixingPVC Gate valve line 25mm , Make of Astral/Ashirvad/Prayag or equivalent etc. As per direction of Engineer in charge. |
| 34 | Providing and fixing 0.75HP Centrifugal pump, Make of Crompton/Kirloskar or equivalent etc. As per direction of Engineer in charge. |
| 35 | Providing and fixing Re winding / Repairing of 0.5HP/0.75HP Centrifugal pump, Make of Crompton/Kirloskar or equivalent etc. As per direction of Engineer in charge. |
| 36 | Providing and fixing 01 SQ mm wire , Make of Anchor/Havells/Finolex or equivalent etc. As per direction of Engineer in charge. |
| 37 | Providing and Filling of Catalytic charged media Mn SO4+KMno4 , Make superior quality As per direction of Engineer in charge. |
| 38 | Providing and Filling of Activatedcarbon media High grade Superior Quality . As per direction of Engineer in charge. |
| 39 | Providing and Filling of Manganese Di-oxide( Mno2) 75% High grade Superior Quality . As per direction of Engineer in charge. |
| 40 | Providing and Filling of Anthracites High grade Superior Quality . As per direction of Engineer in charge. |
| 41 | Providing and Filling of Activated Sand and Gravels of assorted size High grade Superior Quality . As per direction of Engineer in charge. |
| 42 | Providing and fixing of Rubber Gaskets, nut bolts etc |
| 43 | Providing and fixing ofMulti Port Valve 20 mb |
| 44 | Providing and fixing ofFRP Vessel 12X48E, for upto 3kg Pressure |
| 45 | Inspection/Servicing of IRFP and RO Plant (twice in a Month) including checking of all fittings/fixtures, against leakage, checking of electrical connection, water supply connection, tightening of all water connections, back washing, cleaning of membrane, checking of PVC connected pipe items of RO/IRFP plant, checking of TDS etc.(Excluding Installation of consumable/Spare Parts) (24x20= 480 Jobs) |