| 1 | 4 pair, should confirm or exceed the EIA/TIA 568 B.2-1, (CAT 6, CAT 6-A) standards for physical & electrical specifications, Sheath Fire retardant PVC Compound (FRPVC) Flame Rating : 60 deg. C As per UL 1685 CM/CMR, UL listed & Verified, Should be certified by independent test lab (ETL etc.) for Zero bit Error Rate Gigabit Ethernet Performance,23 AWG solid bare copper, ROHS compliant 600MHz (Per Meter) |
| 2 | 4 pair, should confirm or exceed the EIA/TIA 568 B.2-1, (CAT 6, CAT 6-A) standards for physical & electrical specifications, Sheath Fire retardant PVC Compound (FRPVC) Flame Rating : 60 deg. C As per UL 1685 CM/CMR, UL listed & Verified, Should be certified by independent test lab (ETL etc.) for Zero bit Error Rate Gigabit Ethernet Performance,23 AWG solid bare copper, ROHS compliant 600MHz (Per Meter) |
| 3 | 110 wiring block at rear end & RJ 45 jack on front panel, 19” rack mountable, should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Metallic high strength &Height should be 1U , to save the Rack space., confirm EIA/TIA 568 B wiring pattern, should have routing rings & ties and labeling strips for identification, UL listed & Verified, Ports shoild be individually replaceable, ROHS complaint |
| 4 | 110 wiring block at rear end & RJ 45 jack on front panel, 19” rack mountable, should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Metallic high strength &Height should be 1 U , to save the Rack space, confirm EIA/TIA 568 B wiring pattern, should have routing rings & ties and labeling strips for identification, UL listed & Verified., ROHS Compliant |
| 5 | 19 “ rack mountable, Metallic high strength with metal jumper rings for routing cable assemblies, mounts to the front of 19” rack & 1 U height |
| 6 | Surface mount box with single RJ 45 socket, should confirm or exceed the EIA/TIA 568 B standards for CAT 6, provision for dust cover, labeling icons & strips, anchors for contact , UL listed & Verified, (per unit) |
| 7 | Surface mount box with Dual RJ 45 socket, should confirm or exceed the EIA/TIA 568 B standards for CAT 6, provision for dust cover, labeling icons & strips, anchors for contact , UL listed & Verified, (per unit) |
| 8 | Should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Factory molded transparent boots on RJ 45 plugs at both ends, Option for Straight & cross over cable with colour – Grey, Blue, Red & Green. |
| 9 | Should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Factory molded transparent boots on RJ 45 plugs at both ends, Option for Straight & cross over cable with colour – Grey, Blue, Red & Green. |
| 10 | Should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Factory molded transparent boots on RJ 45 plugs at both ends, Option for Straight & cross over cable with colour – Grey, Blue, Red & Green. |
| 11 | Should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Factory molded transparent boots on RJ 45 plugs at both ends, Option for Straight & cross over cable with colour – Grey, Blue, Red & Green. |
| 12 | Should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Factory molded transparent boots on RJ 45 plugs at both ends, Option for Straight & cross over cable with colour – Grey, Blue, Red & Green. |
| 13 | Should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Factory molded transparent boots on RJ 45 plugs at both ends, Option for Straight & cross over cable with colour – Grey, Blue, Red & Green. |
| 14 | Should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Factory molded transparent boots on RJ 45 plugs at both ends, Option for Straight & cross over cable with colour – Grey, Blue, Red & Green. |
| 15 | Should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Factory molded transparent boots on RJ 45 plugs at both ends, Option for Straight & cross over cable with colour – Grey, Blue, Red & Green. |
| 16 | RJ45 Connector |
| 17 | Fiber Optic outdoor armoured cable (OM 3) Multi-mode (MM), 850nmlaser optimized 50/125micron, support 10G Ethernet upto 300 m Multimode optical fiber cable, 850nm laser optimized 50/125 micron graded index, support IEEE 802.3ae 10 gigabit Ethernet standard to full 300m distance, support 10 Gb/s laser based application as well as LED based application, anti-rodent, required for outdoor applications for direct burial, fiber should be protected inside jelly filled loose tube, armouring with acrylic coated good quality steel, should confirm or exceed the EIA/TIA 455, EIA/TIA 568-B.3, ISO 11801 & ICEA -640 standards for Fiber and cable performance specifications, Required in following configuration (Per Meter) |
| 18 | Fiber Optic outdoor armoured cable (OM 3) Multi-mode (MM), 850nmlaser optimized 50/125micron, support 10G Ethernet upto 300 m Multimode optical fiber cable, 850nm laser optimized 50/125 micron graded index, support IEEE 802.3ae 10 gigabit Ethernet standard to full 300m distance, support 10 Gb/s laser based application as well as LED based application, anti-rodent, required for outdoor applications for direct burial, fiber should be protected inside jelly filled loose tube, armouring with acrylic coated good quality steel, should confirm or exceed the EIA/TIA 455, EIA/TIA 568-B.3, ISO 11801 & ICEA -640 standards for Fiber and cable performance specifications, Required in following configuration (Per Meter) |
| 19 | Multimode optical fiber cable, 850nm laser optimized 50/125 micron graded index, support IEEE 802.3ae 10 gigabit Ethernet standard to full 300m distance, support 10 Gb/s laser based application as well as LED based application, anti-rodent, should confirm or exceed the EIA/TIA 455, EIA/TIA 568, ISO 11801 & ICEA -640standards for Fiber and cable performance specifications with LSZH sheathing, required in following configuration (Per Meter) 6 fibers |
| 20 | Single mode optical fiber cable, 9/125 micron graded index, anti-rodent, required for outdoor applications for direct burial, fiber should be protected inside jelly filled loose tube, armoring with acrylic coated good quality steel, should confirm or exceed the EIA/TIA 455, EIA/TIA 568, ISO 11801 & ICEA -640 standards for Fiber and cable performance specifications., required in following configuration |
| 21 | Single mode optical fiber cable, 9/125 micron graded index, anti-rodent, required for outdoor applications for direct burial, fiber should be protected inside jelly filled loose tube, armoring with acrylic coated good quality steel, should confirm or exceed the EIA/TIA 455, EIA/TIA 568, ISO 11801 & ICEA -640 standards for Fiber and cable performance specifications., required in following configuration |
| 22 | Single mode optical fiber cable, 9/125 micron graded index, anti-rodent, required for outdoor applications for direct burial, fiber should be protected inside jelly filled loose tube, armoring with acrylic coated good quality steel, should confirm or exceed the EIA/TIA 455, EIA/TIA 568, ISO 11801 & ICEA -640 standards for Fiber and cable performance specifications., required in following configuration |
| 23 | 9/125 single mode fiber optic cables that are compliant to ISO/IEC 11801 with LSZH sheathing |
| 24 | 9/125 single mode fiber optic cables that are compliant to ISO/IEC 11801 with LSZH sheathing |
| 25 | SC type, Epoxyless, Field mountable with required accessories & consumables, required for terminating (per unit) |
| 26 | SC type, Epoxyless, Field mountable with required accessories & consumables, required for terminating (per unit) |
| 27 | LC type, Epoxyless, Field mountable with required accessories & consumables, required for terminating (per unit) |
| 28 | LC type, Epoxyless, Field mountable with required accessories & consumables, required for terminating (per unit) |
| 29 | Duplex, 50/125 micron MM fiber, SC connector at both ends, LSZH Sheathing with factory mount ceramic connector at both end with length ofa) 3 metre |
| 30 | Duplex, 50/125 micron MM fiber, SC connector at both ends, LSZH Sheathing with factory mount ceramic connector at both end with length ofb) 5 metre |
| 31 | Duplex, 50/125 micron MM fiber, SC connector at both ends, LSZH Sheathing with factory mount ceramic connector at both end with length ofc) 10 metre |
| 32 | Duplex, 50/125 micron MM fiber, SC connector at both ends, LSZH Sheathing with factory mount ceramic connector at both end with length ofd) 20 metre |
| 33 | Duplex, 50/125 micron MM fiber, LC connector on both ends, LSZH Sheathing with factory mount ceramic connector at both end with length ofa) 3 metre |
| 34 | Duplex, 50/125 micron MM fiber, LC connector on both ends, LSZH Sheathing with factory mount ceramic connector at both end with length ofb) 5 metre |
| 35 | Duplex, 50/125 micron MM fiber, LC connector on both ends, LSZH Sheathing with factory mount ceramic connector at both end with length ofc) 10 metre |
| 36 | Duplex, 50/125 micron MM fiber, LC connector on both ends, LSZH Sheathing with factory mount ceramic connector at both end with length ofd) 20 metre |
| 37 | Duplex, 50/125 micron MM fiber, SC connector at one end and LC connector on other end, LSZH Sheathing with factory mount ceramic connector at both end with length ofa) 3 metre |
| 38 | Duplex, 50/125 micron MM fiber, SC connector at one end and LC connector on other end, LSZH Sheathing with factory mount ceramic connector at both end with length ofb) 5 metre |
| 39 | Duplex, 50/125 micron MM fiber, SC connector at one end and LC connector on other end, LSZH Sheathing with factory mount ceramic connector at both end with length ofc) 10 metre |
| 40 | Duplex, 50/125 micron MM fiber, SC connector at one end and LC connector on other end, LSZH Sheathing with factory mount ceramic connector at both end with length ofd) 20 metre |
| 41 | Duplex, 9/125 micron SM fiber, LC connector at one end and FC connector on other end, with factory mount ceramic connector at both end with length ofa) 3 metre |
| 42 | Duplex, 9/125 micron SM fiber, LC connector at one end and FC connector on other end, with factory mount ceramic connector at both end with length ofb) 5 metre |
| 43 | Duplex, 9/125 micron SM fiber, LC connector at one end and FC connector on other end, with factory mount ceramic connector at both end with length ofc) 10 metre |
| 44 | Duplex, 9/125 micron SM fiber, LC connector at one end and FC connector on other end, with factory mount ceramic connector at both end with length ofd) 20 metre |
| 45 | Duplex, 9/125 micron SM fiber, SC connector at both ends, with factory mount ceramic connector at both end with length ofa) 3 metre |
| 46 | Duplex, 9/125 micron SM fiber, SC connector at both ends, with factory mount ceramic connector at both end with length ofb) 5 metre |
| 47 | Duplex, 9/125 micron SM fiber, SC connector at both ends, with factory mount ceramic connector at both end with length ofc) 10 metre |
| 48 | Duplex, 9/125 micron SM fiber, SC connector at both ends, with factory mount ceramic connector at both end with length ofd) 20 metre |
| 49 | Duplex, 9/125 micron SM fiber, SC connector at one end and LC connector on other end, with factory mount ceramic connector at both end with length ofa) 3 metre |
| 50 | Duplex, 9/125 micron SM fiber, SC connector at one end and LC connector on other end, with factory mount ceramic connector at both end with length ofb) 5 metre |
| 51 | Duplex, 9/125 micron SM fiber, SC connector at one end and LC connector on other end, with factory mount ceramic connector at both end with length ofc) 10 metre |
| 52 | Duplex, 9/125 micron SM fiber, SC connector at one end and LC connector on other end, with factory mount ceramic connector at both end with length ofd) 20 metre |
| 53 | Pigtails SC type, compatible with fusion or mechanical splices, Field mountable with required accessories & consumables, for terminating (per unit)a) 50/125 micron MM fiber |
| 54 | Pigtails SC type, compatible with fusion or mechanical splices, Field mountable with required accessories & consumables, for terminating (per unit)b) 9.2/125 micron SM fiber |
| 55 | Loaded with SC ceramic couplers & adaptor plates for 12 fibers 50/125 micron MM, 19” rack mountable metallic distribution enclosure slide & tilt drawer type 1U/2U, should have inbuilt / pre-installed splice tray with all clamps, harnessing rings, ties etc, compatible cable management rings/ bars should be provided |
| 56 | Loaded with LC ceramic couplers & adaptor plates for 12 fibers 50/125 micron MM, 19” rack mountable metallic distribution enclosure slide & tilt drawer type 1U/2U, should have inbuilt / pre-installed splice tray with all clamps, harnessing rings, ties etc, compatible cable management rings/ bars should be provided |
| 57 | Loaded with SC ceramic couplers & adaptor plates for 24 fibers 50/125 micron MM, 19” rack mountable metallic distribution enclosure 1U/2U height with removable back cover, should have inbuilt / pre- installed splice tray with all clamps, harnessing rings, ties etc, Front & rear compatible cable management rings/ bars should be provided |
| 58 | Loaded with LC ceramic couplers & adaptor plates for 24 fibers 50/125 micron MM , 19” rack mountable metallic distribution enclosure 1U/2U height with removable back cover, should have inbuilt / pre- installed splice tray with all clamps, harnessing rings, ties etc, Front & rear compatible cable management rings/ bars should be provided |
| 59 | Route Survey & documentation for laying of UTP & Fibre cable along with detailed cable route diagram, rack position , cable length from each node to switch , identification of switch location with labels & rout marking as per standard and approved labelling plan etc on per node basis |
| 60 | In building laying of UTP CAT 6/CAT 6-A Cable ( Shielded/Unshielded) (Per Meter) |
| 61 | Removing of cable/duct ( as per actual removed cable/duct) (Per meter) |
| 62 | Supply of duct (per meter) |
| 63 | Supply of duct (per meter) |
| 64 | Supply of duct (per meter) |
| 65 | Fixing of duct |
| 66 | Fixing of duct |
| 67 | Fixing of duct |
| 68 | Supply of PVC Conduit of OD size (per Meter) |
| 69 | Supply of PVC Conduit of OD size (per Meter) |
| 70 | Supply of PVC Conduit of OD size (per Meter) |
| 71 | fixing of PVC Conduit of OD size (per Meter) |
| 72 | fixing of PVC Conduit of OD size (per Meter) |
| 73 | fixing of PVC Conduit of OD size (per Meter) |
| 74 | Installation of Jack Panel & termination of UTP CAT 6 & 6A cable on Jack panel (12 port) ( per port/node) |
| 75 | Installation of Jack Panel & termination of UTP CAT 6 & 6A cable on Jack panel (24 port) ( per port/node) |
| 76 | Installation of Jack Panel & termination of UTP CAT 6 & 6A cable on Jack panel (48 port) ( per port/node) |
| 77 | Crimping of RJ 45 connectors per connector |
| 78 | Installation & Termination of information outlets (including termination of CAT 6 & 6A cable on I/O)(per node) |
| 79 | Testing of laid cables for the nodes (per node) |
| 80 | Site certification for performance warranty of 20 yearsthrough OEM, Network Audit |
| 81 | Site certification for performance warranty of 20 yearsthrough OEM, Network Audit |
| 82 | Site certification for performance warranty of 20 yearsthrough OEM, Network Audit |
| 83 | In building laying of fiber in duct/conduit (per meter) |
| 84 | Outdoor laying of fiber with (per meter), wherever required |
| 85 | Excavation and resurfacing of the soil (depth 1 mtr) (per meter), or as per requirement |
| 86 | Excavation and resurfacing of concrete (per meter) |
| 87 | Excavations under road crossing & rail track without effecting the traffic (per meter) |
| 88 | Supply and installation / fixing of 1\"diameter GI pipe underground and on surface (per meter) |
| 89 | Supply and installation / fixing of 2\"diameter GI pipe underground and on surface (per meter) |
| 90 | Supply and installation of 1.5\"diameter HDPE PVC jacket for underground laying (per meter) |
| 91 | Supply and installation of 2\"diameter HDPE PVC jacket for underground laying (per meter) |
| 92 | Supply and installation of 4\"diameter HUME pipe for underground laying (per meter) |
| 93 | SC/LC connector termiantion on Fiber Optic Cable (wih support of proper buffer tubing & termination of fibers in Fiber Termination/ Interconnection Unit with SC/LC coupler) per unit |
| 94 | Supply and installation of buffer tubing kit |
| 95 | Cable pulling pit made of reinforced concrete and brick walls with removable covers, (Cable Vault), in coordination with concerned agency |
| 96 | Performance testing of laid Fiber Optic Cable for continuity, length & dB loss as per EIA/TIA-455-60 document for FO test procedures & Documentation of the results (per link) |
| 97 | Installation and Termination of fiber termination/Interconnection unit with SC/LC Coupler (per Unit) |
| 98 | Pigtail splicing per unit |
| 99 | Fiber splicing per unit |
| 100 | Should confirm DIN 41494 & IEC 297 standard, Load bearing capacity of 40 Kgs, having following accessories 19 “ AC power distribution channel with 5 & 15 Amp power Universal/Indian standard sockets & two fans with wall mounting hardware |
| 101 | Installation of 6U Rack |
| 102 | Should confirm DIN 41494 & IEC 297 standard, Load bearing capacity of 40 Kgs, having following accessories 19 “ AC power distribution channel with 5 & 15 Amp power Universal/Indian standard sockets & two fans with wall mounting hardware |
| 103 | Installation of 9U Rack |
| 104 | Should confirm DIN 41494 & IEC 297 standard, Load bearing capacity of 40 Kgs, having following accessories 19 “ AC power distribution channel with 5 & 15 Amp power Universal/Indian standard sockets & spike suppressor, equipment mounting screws/hardware packets (2 nos), with two fan |
| 105 | Installation of 12U Rack |
| 106 | Dressing of 6U rack withoutaccessories |
| 107 | Dressing of 9U rack withoutaccessories |
| 108 | Dressing of 12U rack withoutaccessories |
| 109 | Network Switch 24 ports |
| 110 | Network Switch 48 ports |
| 111 | Network Switch 8 ports |
| 112 | Network Switch 16 ports |
| 113 | Network Switch 24 ports |
| 114 | Network Switch 48 ports |
| 115 | Wi-Fi |
| 116 | SFP |
| 117 | SFP |
| 118 | SFP |
| 119 | SFP |
| 120 | SFP |
| 121 | Comprehensive Annual Maintenance Contract (CAMC) of Local Area Network & Networking Work (consists of around 4000 active network nodes and various LAN Switches, LAN Networks etc.) for a Period of one year i.e. 1st Year |
| 122 | Comprehensive Annual Maintenance Contract (CAMC) of Local Area Network & Networking Work (consists of around 4000 active network nodes and various LAN Switches, LAN Networks etc.) for a Period of one year i.e. 2nd Year |
| 123 | Cost ofNetwork Administrator (Per Engineer) (Per Month)• Will serve as the overall Network In-Charge for the Supreme Court’s Main Building Complex, Administrative Buildings Complex, and the Residential Office/Guest House of Hon’ble Judges.• Responsible for end-to-end network operations, performance monitoring, routing & switching management, firewall oversight, and overall network availability.• Acts as the primary point of contact for coordination with NIC, NKN, ISP(s), OEM(s), and other support agencies.• Oversees incident management, change management, documentation, and policy compliance. |
| 124 | Cost of Senior Network Field Officer (Senior NFO) (Per Engineer) (Per Month)• Assists the Network Administrator in day-to-day network operations and escalated issues.• Supervises NFO teams deployed across different Supreme Court locations.• Responsible for advanced troubleshooting, network performance checks, and coordination during maintenance windows.• Ensures timely resolution of critical incidents and supports planning of network upgrades/expansions. |
| 125 | Cost of Network Field Officers (NFOs) (Per Engineer) (Per Month)• Responsible for day-to-day network operations, L1/L2 troubleshooting, user-side issue resolution, and on-site technical support.• Perform network device health checks, monitoring, and escalation to Senior NFO or Network Administrator when required.• Provide support during configuration changes, link migrations, maintenance activities, and new service deployments.• Coordinate with internal teams and NIC/ISP teams for issue resolution across all Supreme Court locations. |