| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil |
| 2 | Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, Note:-Excavation of hard rock shall be the property of the contractor subject to recovery. excavated material has to shift from site within 15 days after instruction issued by Engineer-In- Charge otherwise after this penalty will imposed on contractor at the rate of Rs 50 per cum per day. Hard rock (blasting prohibited) |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : With 20mm nominal size graded stone aggregate. M-10 Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level |
| 5 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. Uptoplinthlevel. |
| 6 | Extra for shuttering in circular work or any other geometrical shape (20%of respectivecentering and shuttering items). |
| 7 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Columns, Pillars , Piers, Abutments, Posts and Struts. |
| 8 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Lintels, beams, girders, bressumers and cantilevers |
| 9 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. |
| 10 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Weather shade, Chajjas, corbels etc., including Edges. |
| 11 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Shelves(Cast in situ) |
| 12 | Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete |
| 13 | Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: M-20 Grade Concrete |
| 14 | Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate)in beams, suspended floors, roofs havingslope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstaircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. M-20 Grade Concrete |
| 15 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS-456 RCC Design & SP 34 Reinforcement detailing ) etc. complete .(Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.2. No extra payment shall be done for overlaps and/or couplers.3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) Thermo-Mechanically Treated bars. FE 500conforming to IS 1786 |
| 16 | Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 17 | Supplying chemical emulsion in sealed containers including delivery as specified. (Chlorpyriphos/ Lindane emulsifiable concentrate of 20%) |
| 18 | Providing and fixing circular/ Hexagonalcast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mmheight, top lid of 1.5mm thick M.S. sheetwith its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 16mm dia M.S. bar bent to shape as per standard drawing. |
| 19 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, up to plinth : Having 50 kg / cm2 average compressive strength. Cement mortar 1:6 (1 cement : 6 sand) |
| 20 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : Having 50 kg / cm2 average compressive strength. Cement mortar 1:6 (1 cement : 6 sand) |
| 21 | Half brick masonry with fly ash lime Gypsum bricks (FALG bricks) conforming to IS: 12894, in super structure above plinth and upto floor two level.: Having 50 kg / cm2 average compressive strength. Cement mortar 1:4 (1 cement : 4 sand) |
| 22 | Supplying and applying fibre reinforced, UV resistant elastomeric liquid applied waterproofing & Heat reflective coating coating with PU Hybrid polymers & acrylic fibers. The coating shall resist 10 bars of water pressure as per DIN 1048 standards, with elongation of 350% as per ASTM D412 &crack bridging of upto 2.5mm conforming to ASNZ standard. The operation shall be carried out after scrapping and properlycleaning the surface to remove loose particles with wire brushes, complete in all respect as recommended by the manufacturer’s specification and as per the direction of Engineer-in-Charge |
| 23 | Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominalsize graded stone aggregate.) |
| 24 | Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours& shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand)preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 25 | Providing and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 26 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece |
| 27 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. |
| 28 | Structural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 29 | Providing and fixing factory made ISI marked glazed steel doors, windows and ventilators side /top /centre hung with beading and Z-section all members such as F7D, F4B, K11 B and K12 B and other tubular section member etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of Cement Concrete 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 20 mm nominal size). |
| 30 | Providing and fixing glass panes/ steel sheet/ fibre sheet with putty and glazing clips in steel doors, windows, clerestory windows all complete. With 4.0 mm thick glass panes |
| 31 | Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion 110 mm diameter (minimum wall thickness 2.2mm) |
| 32 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend (minimum wall thickness 2.2mm) |
| 33 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc.complete. 110 mm (minimum wall thickness 2.2mm) |
| 34 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe (minimum wall thickness 2.2mm) |
| 35 | Providing and fixing to the inlet mouth of rain water pipe fixing cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 36 | UPVC trap of self cleaning design Providing and fixing UPVC trap ofself cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet |
| 37 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting andmaking good the walls and floors wherever required : White plastic seat cover and lid W.C. pan with ISI marked white solid plastic seat and lid |
| 38 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 39 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe (only in residential & complaxes) 32 mm dia |
| 40 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper |
| 41 | Providing and fixing PTMT grating of approved quality and colour. Circular type. 125 mm nominal dia with 25 mm waste hole. |
| 42 | Providing and fixing C.P. brass grating of approved quality and make conforming to IS: specification. 100 mm dia |
| 43 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 600mm long towel rail with totallength of 645mm, width 78mm and effective height of 88mm, weighingnot less than 190gms. |
| 44 | Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 45 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Concealed pipe including painting with anti corrosivebitumastic paint, cutting chases and making good the wall. 15 mm dia nominal bore |
| 46 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work - Internal work - Exposed on wall 20 mm dia. nominal bore |
| 47 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore. |
| 48 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931and weighing not less than 400gm, 15 mm nominal bore. |
| 49 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 50 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) |
| 51 | 12 mm cement plaster of mix :1:4 (1 cement : 4 sand) |
| 52 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 sand) |
| 53 | Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 54 | Wall painting by any mechanical or manual means with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand andmanufacture, including applying additional coats wherever required, toachieve even shade and colour. Two coats |
| 55 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 56 | Providing and fixing squaremouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design : 100x100 mm size P type With well burnt bricks |
| 57 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stoneaggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard designInside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With well burnt bricks. |
| 58 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 59 | Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out theexcavatedsoil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavatedsoil as directed, within a lead of 50 m : (No extra lift is payable if work is done by mechanical means) in all kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 60 | Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 andIS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly. 110 mm diameter OD(min. wall thickness 3.2mm) |
| 61 | Providing and laying cement concrete 1:3:6 (1 cement: 3sand: 6 graded stone aggregate 20 mm nominal size) all-round PVC. Pipes including bed concrete as per standarddesign: 110 mm diameter PVC. pipe |
| 62 | Supplying and fixing of FRP/GRP composite manhole cover with frame of clearopening size 600mm (round) having weight of (complete unit) (weight of frame 13.6kg + weight of cover 43.1kg + - 10%) (HD/25MT) having load bearing capacity (Point load 25MT) asper testing code BSEN 124:1994. having lifting arrangement should have an insertion of 5 mm double sealed closed key hole and high strength plastic alloy/stainless steel socketed arrangement |
| 63 | Providing, laying and jointing including testing following socket & spigot centrifugally cast (Spun) Ductile Iron pressure pipes with inside cement mortar lining (class K-7) conforming to IS 8329/2000 with suitable Rubber Gasket (Push on) joints as per IS:5382/85 4/29/2025 - 300 mm diameter |
| 64 | Providing, laying and jointing including testing following socket & spigot centrifugally cast (Spun) Ductile Iron pressure pipes with inside cement mortar lining (class K-7) conforming to IS 8329/2000 with suitable Rubber Gasket (Push on) joints as per IS:5382/85 4/29/2025 - 200 mm diameter |
| 65 | Providing, laying and jointing including testing following socket & spigot centrifugally cast (Spun) Ductile Iron pressure pipes with inside cement mortar lining (class K-7) conforming to IS 8329/2000 with suitable Rubber Gasket (Push on) joints as per IS:5382/85 4/29/2025 - 150 mm diameter |
| 66 | Providing, laying and jointing including testing following socket & spigot centrifugally cast (Spun) Ductile Iron pressure pipes with inside cement mortar lining (class K-7) conforming to IS 8329/2000 with suitable Rubber Gasket (Push on) joints as per IS:5382/85 4/29/2025 - 100 mm diameter |
| 67 | Providing and Laying including testing ductile iron PN 16 type flanged sockets conforming to IS:9523/2000 having dimension as per table 23 of IS:9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining with finishing as per clause 13 of IS:9523/2000. 300 mm diameter |
| 68 | Providing and Laying including testing ductile iron PN 16 type flanged sockets conforming to IS:9523/2000 having dimension as per table 23 of IS:9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining with finishing as per clause 13 of IS:9523/2000. 200 mm diameter |
| 69 | Providing and Laying including testing ductile iron PN 16 type flanged sockets conforming to IS:9523/2000 having dimension as per table 23 of IS:9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining with finishing as per clause 13 of IS:9523/2000. 150 mm diameter |
| 70 | Providing and Laying including testing ductile iron PN 16 type flanged sockets conforming to IS:9523/2000 having dimension as per table 23 of IS:9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining with finishing as per clause 13 of IS:9523/2000. 100 mm diameter |
| 71 | Providing and Laying including testing Ductile Iron Double Socket 45° Bends conforming to IS:9523/2000 having dimension as per table 16 of IS:9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 300 mm diameter |
| 72 | Providing and Laying including testing Ductile Iron Double Socket 45° Bends conforming to IS:9523/2000 having dimension as per table 16 of IS:9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 200 mm diameter |
| 73 | Providing and Laying including testing Ductile Iron Double Socket 45° Bends conforming to IS:9523/2000 having dimension as per table 16 of IS:9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 150 mm diameter |
| 74 | Providing and Laying including testing Ductile Iron Double Socket 45° Bends conforming to IS:9523/2000 having dimension as per table 16 of IS:9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. 100 mm diameter |
| 75 | Providing and Laying including testing Ductile Iron All socket Tees conforming to IS-9523/2000 having dimension as per table 21 of IS-9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining with finishing as per clause 13 of IS-9523/2000.300 mm x 300 mm |
| 76 | Providing & fixing of following Ductile iron double flanged sluice valves as per IS :14846-2000 fitted with cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. Class PN 1.0 - 300 mm diameter |
| 77 | Providing & fixing of following Ductile iron double flanged sluice valves as per IS :14846-2000 fitted with cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. Class PN 1.0 - 200 mm diameter |
| 78 | Providing & fixing of following Ductile iron double flanged sluice valves as per IS :14846-2000 fitted with cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. Class PN 1.0 - 150 mm diameter |
| 79 | Providing & fixing of following Ductile iron double flanged sluice valves as per IS :14846-2000 fitted with cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete. Class PN 1.0 - 100 mm diameter |
| 80 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. internal work - Exposed on wall 25 mm dia. nominal bore |
| 81 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 82 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- Using modular accessorie (Light point/fan points) looping point, Primary short point |
| 83 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- Using modular accessorie (Light point/fan points) looping point,Primary medium point |
| 84 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- Using modular accessorie (Light point/fan points) looping point,Primary long point |
| 85 | Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC conduit (MMS) ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes forClassification of Conduit Wiring Point No.10) 3 Wire sub main 2.5 sq. mm. cable |
| 86 | Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board : 100 Watt (1 module). |
| 87 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single Pole MCB SP 6Amp to 32Amp 10kA rating |
| 88 | Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection) ISI marked complete as per I.S. standard conforming to IEC:61009-1 & IS:12640-2, 240/415V 50 Hz with 10 kA short circuit withstand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification DP (4 module) 2 pole 32Amp, 30mA sensitivity |
| 89 | Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar,connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 12 Way double door IP 43 protection |
| 90 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVCinsulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- Power point On separate board: Medium point Using modular accessories |
| 91 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVCinsulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- Power point On separate board: Long point Using modular accessories |
| 92 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 4 Module metal box |
| 93 | Earthing with G.I. earth plate 600mm X600mm X 6mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without charcoal or coke and salt) complete as required |
| 94 | Add extra for using salt and charcoal/coke for G.I. plate or copper plate earth electrode as required including excavation and refilling the pit in all type of soil, murrum |
| 95 | Providing and fixing 25mm X 5mm G.I.strip in 40 mm dia G.I. pipe from earthelectrode as required |
| 96 | Supply and laying 25mm X 5mm G.I. strip at 0.5 metre below ground level as strip earth electrode including jointing etc. as required. |
| 97 | Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15mm dia G.I. Pipe from earth electrode as required. |
| 98 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor : Armoured 3 core 25 sq. mm |
| 99 | Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments. Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value ≥ 4.00 as per BEE. |
| 100 | Supply and fixing Led tube rod comprising of LED tube with non integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should bemore than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser. |
| 101 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 6 Module metal box |
| 102 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 12 Module metal box |
| 103 | Laying of one number armoured / unarmoured power cable 1.1KV grade of size not exceeding 25 sq. mm direct in ground including excavation in all soil/ murrum /soft rock, sand cushioning,protective covering and refilling the pit etc. as required. |