| 1 | Civil Items |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 4 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 5 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 6 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, away from CSIR-CLRI Regional Centre, Jalandhar campus ) , for all leads including all lifts involved. |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer byamming and watering, lead up to 50 m and lift upto 1.5 m. |
| 9 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 11 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete below and above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers |
| 14 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 16 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form forEdges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 18 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 19 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:1½:3 (1 cement : 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 20 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position andapplying a suitable priming coat of approved epoxy primer and two coats of epoxy paintall complete as per the direction of engineer in charge.In gratings, frames, pipe clamp stand, guard bar, ladder, railings, brackets, gates and similar works |
| 21 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron \"Y\" shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 22 | Finishing walls with 100% Premium acrylic emulsion painthaving VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistanceexterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coatof exterior primer applied @ 0.90 litre/10 sqm. |
| 23 | Electrical Items |
| 24 | DWC HDPE PIPE LAYING: Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (750 mm below ground level) including excavation and refilling thetrench,etc.,complete as required.Make: Gemini/Rex/Duraline63 mm dia (OD-120 mm & ID-103 mm nominal) |
| 25 | MV CABLE LAYING:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC/PVC pipe as required.Upto 35 sq. mm |
| 26 | MV Cable laying in wall:-Laying and fixing of one number PVC insulated and PCV shealted /XLPE power cable of 1.1 kV grade following size on wall surface/recesses as required.Upto 35sq mm (clamped with 1 mm thick saddle) |
| 27 | CABLE END TERMINATION: Supplying and making end termination with brass compression gland and Aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.Make: LOTUS/COMET/DOWELLS4 X 6 sq. mm |
| 28 | CABLE END TERMINATION: Supplying and making end termination with brass compression gland and Aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.Make: LOTUS/COMET/DOWELLS4 X 10 sq. mm |
| 29 | SINGLE ARM G.I PIPE: Supplying and embendding following dia G.I pipe (Medium class) in collar/foundation (during casting) for cable entry including bending the pipe to the required shape and fixing the pipe in surface G.I clamp,bolt,nut & washer etc. complete as required. 40mm dia |
| 30 | Circuit Wiring in existing 3X1.5sqmm: Supplying and drawing of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. MAKE:POLYCAB/FINOLEX/HAVELLS |
| 31 | Circuit Wiring 3X1.5sqmm: Supplying and drawing of FRLS PVC insulated copper conductor, single core cable in the surface/recessed medium class PVC conduit as required. MAKE:POLYCAB/FINOLEX/HAVELLS |
| 32 | SUPPLY OF 4 CORE,6 SQ MM,ALUMINIUM UG CABLE:Supply of 4 core, 6 sq mm,PVC insulated, Sheathed and armoredaluminium 1100 Vgrade as per IS 1554 Standard UG cable, produce with necessary test certificate etc. as required. Make: Finolex/Polycab/Q-Flex |
| 33 | SUPPLY OF 4 CORE,10 SQ MM,ALUMINIUM UG CABLE:Supply of 4 core, 10sq mm,PVC insulated, Sheathed and armoredaluminium 1100 Vgrade as per IS 1554 Standard UG cable, produce with necessary test certificate etc. as required. Make: Finolex/Polycab/Q-Flex |
| 34 | SMC BOX: Supplying and Installing of suitable size SMC box comprises with one no. of 6-32 A SP MCB & 6 no.s of 25sqmm elmax connector with mounting rail and same fixingon the existing compound wall/light post,giving connection etc..,as required.Make: SINTEX /ELMAX/L&T |
| 35 | POST ANGLED LED FIXTURE: Supply,Installation,testing and commisioning of prewired,LED 45W street light outdoor fitting Pressure die cast aluminium with heat resistant toughened glass and IP-66 Protection, including driver andexisting GI medium class Pipe for fixing the fitting with bolt,nut,washer an existing arm,making the connection with 1.5sqmm FRLS PVC insulated copper conductor,single core cable to smc cable terminal box.etc,as required.Make: Crompton /Philips/ Havalls. |