| 1 | Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator) / manual means in foundation/trenches or drains not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed. |
| 2 | M&L Providing and laying in position cement concrete of 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth levelcomplete all as specified and directed. |
| 3 | M&L Providing and laying in position specified grade of Reinforced cement concrete excluding the rate of centering ,shuttering and finishing,and reinforcement M-25 (Design Mix) all work upto plinth level.(foundation,footing,plinth beam etc) complete all as specified and directed. |
| 4 | M&L Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with M-25 (Design Mix) complete all as specified and directed. |
| 5 | M&L Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses,plinth and string course, fillet columns, pillars, piers, abutments, post and struts etc above plinth level upto floor five level excluding cost of centering,shuttering finishing and reinforcement M-25 (Design Mix) complete all as specified and directed. |
| 6 | M&L Steel reinforcement Thermo-Mechanically Treated bars of grade Fe-500D or more for R.C.C. work including straightening, cutting,bending, placing in position and binding complete all as specified and directed. |
| 7 | M&L Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform complete all as specified and directed. |
| 8 | M&L Centering and shuttering including strutting, propping etc. and removal of form for foundation,footing,etc for mass concrete complete all as specified and directed. |
| 9 | M&L Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantileverscomplete all as specified and directed. |
| 10 | M&L Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Strutscomplete all as specified and directed. |
| 11 | M&L Centering and shuttering for edges of slabs and breaks in floor and walls under 20cm wide complete all as specified and directed. |
| 12 | Material & Labour for 12mm thick cement plaster in CM 1:4(1 cement :4 fine sand) on brick or concrete surfaces finished even and fair complete all as specified and directed. |
| 13 | Material & Labour for 15mm thick cement plaster in two layers in CM 1:4 outer layer 5mm thickcomplete all as specified and directed. |
| 14 | M&L Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works, and applying a priming coat of approved steel primer using structural steel etc as required (Ornamental gates) complete all as specified and directed |
| 15 | M&L for applying two coat of Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeover a coat of primerincl preparation of new steel surfaces complete all as specified and directed. |
| 16 | Providing and laying Polished Granite stone slab floorings of all colour and texture Z-black/Ruby red/Lakha red in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc complete all as specified and directed. |
| 17 | Removing building materials etc.to a distance of upto 20 KM, beyond the lead included in the rates, including loading, unloading and stacking at the destination out side of MoD land complete all as specified and directed. |
| 18 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m complete all as specified and directed. |
| 19 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead complete all as specified and directed. |
| 20 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified and directed |
| 21 | Demolishing brick work manually/ by mechanical means In cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed |
| 22 | Brick work with non modular fly ash brick confirming to IS-12894 of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : built in cement mortar 1:6complete all as specified and directed |
| 23 | S&F Stainless steel letters or figures (Block.,roman, Italic or Indian) n exc. 30 cm high complete all as specified and directed. |
| 24 | Taking out doors, windows and clerestory window frame with shutter (without taking off shutter from frame) of area beyond 3sqm (steel or wood) including staking within 50mtr lead complete all as specified and directed. |
| 25 | Taking out chowkhat of doors, windows and clerestory window frame with shutter(without taking off shutter from frame) (steel or wood)of area 3 sq. metres and below including stacking within 50 metres leadcomplete all as specified and directed. |
| 26 | Taking out doors, windows and clerestory window shutters (steel or wood)of area below 3 sq. metresincluding stacking within 50 metres lead complete all as specified and directed. |
| 27 | Providing wood work of second class teak wood of factory made using in frames of doors and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastners of required dia & length(hold fast lugs or dash fastner shall be paid for separately). |
| 28 | S&F 40mm thick designer Solid wooden door(First class hard wood Sangwan) with any number of panels complete all as spd and directed. |
| 29 | M&L 30mm thick( first class HW Sagwan) Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24(a) fitted to chowkhat complete all as specified and directed. |
| 30 | Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge Including S/S door handle of 450mm long 2Nos per leaf and door lock suitable for double leaf glass door including drilling,clips ,fastners etc fixing in door glass complete all as specified and directed. |
| 31 | Providing and fixing bright finished brass tower bolt (barrel type) with necessary screws etc.size 250x10mm complete all as specified and directed. |
| 32 | Providing and fixing chromium plated brass handles size 125mm with necessary screws etc complete all as specified and directed. |
| 33 | Providing & fixing 5.0 mm thick glass panes with putty and glazing clips in steel doors, windows, clerestory windows, complete all as specified and directed |
| 34 | Providingfeature wall tilesmade of Wood Fibre cement composites with an option of colours as per the choice of the Architect/ person in charge of size 1200 X 600 mm highly recommend for walls . Has excellent noise absorption of 1 NRC as per ISO: 354-1985 and ASTM 423-90 a, Density 400 Kg/ m3, meets stringent Fire Ratings ASTMD-876 and Fire Class -1 and Class P-not easily ignitable as per BS-476-Part 5,6,7, weather resistance as per IS 3308, Thermal Insulation as per IS:3346-1980 with relative humidity of 90% RH at 60° Celsius (140° Fahrenheit) for 15 days= No deterioration. Tested as per En 131682001 and are RoHS Complaint. To be installed on G.I studs 600x600mm centre to centre2400mm X 25mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dippedgalvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life complete all as specified and directed |
| 35 | SupplyingAcoustics Elegant Wood Tile 600x600x5mm with square edge density 1050kg/m3 covered with laminate on front side and Acoustics fibre on the back side, thus making it acoustically absorbtive, water resistance, fire resistant.The tiles are anti sag and are to be installed with Aluminium H Profile on G.I studs 600x600mm centre to centre 2400mm X 25mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life complete all as specified and directed. |
| 36 | Providing and Fixing Acoustics Cement Fibre Elegant tile of size 600x600/600X1200mm andthickness 9 mmwith square edge density 1050kg/m3 covered with absorbtive microfiber coating on the front side colour as per the choice of the Architect/ person in charge and Acoustics fibre on the back side, thus making it acoustically absorbtive, water resistance, fire resistant Absorption Cofficient upto 0.89 at 160 Hz tested as per ISO 354 and Anti-Bacterial test as per JIS-Z2801-2010. The tiles are anti sag and are to be installed with Aluminium H profile on G.I studs 600x600mm centre to centre 2400mm X 25mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life complete all as specified and directed. |
| 37 | Supplying & Fixing of Acoustic Woodlot Premium 16mm thick with coloured grooves are pigmented as per the same shade as MDF finish. “Wooden slat Premium‟ FR grades min 2400X131 mm made of MDF backed with acoustical fleece providing sound absorption of 0.88 NRC as per ISO 354. to be installed with 15mm aluminium profile conforms to aluminium alloy 6063-t 6. Temper as per bs:1474-1987 and G.I lock in clips on the back of tongue and groove system. The density per panel is 750-800 kg/m3.the panels come with tongue & groove for seamless patterns, 4-28mm groove and visible panel and groove are pigmented as per the same shade as MDF finish. These slats are made from acoustical fibre board with linear perforations for excellent uniformity. The perpendicular holes are available on the back of panel which are covered by black acoustical fleece. Achieves sound reduction of 0.88NRC. To be installed on G.I studs 600x600mm centre to centre 2400mm x 25mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for acoustic vibration management and long life complete all as specified and directed. |
| 38 | S&F wooden moulding 12.5mm with polish complete all as specified and directed. |
| 39 | S&F wooden moulding 25mm with polish complete all as specified and directed. |
| 40 | S&F wooden moulding 45mm with polish complete all as specified and directed. |
| 41 | S&F wooden moulding 65mm with polish complete all as specified and directed. |
| 42 | Supplying & Fixing ofAcousticfalse ceiing 16mm thick with coloured grooves are pigmented as per the same shade as MDF finish. “Wooden slat Premium‟ FR grades min 2400X131 mm made of MDF backed with acoustical fleece providing sound absorption of 0.88 NRC as per ISO 354. to be installed with 15mm aluminium profile conforms to aluminium alloy 6063-t 6. Temper as per bs:1474-1987 and G.I lock in clips on the back of tongue and groove system. The density per panel is 750-800 kg/m3.the panels come with tongue & groove for seamless patterns, 4-28mm groove and visible panel and groove are pigmented as per the same shade as MDF finish. These slats are made from acoustical fibre board with linear perforations for excellent uniformity. The perpendicular holes are available on the back of panel which are covered by black acoustical fleece. Achieves sound reduction of 0.88NRC. To be installed on G.I studs 600x600mm centre to centre 2400mm x 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for acoustic vibration management and long life.Final finishes of Coffer ceiling made of teak wooden studs and wooden beading with polish complete all as specified and directed |
| 43 | Complete removal of existing treatment from plastered or unplastered surfaces of wall/ceiling complete all as specified and directed. |
| 44 | M&L for Two coat of plastic emulsion paint on old painted walls/ceiling etc.including preparation of old decorated surfaces by brooming down or steel wire brushing, scrabing down smoke soot, moulds, moss and efforescent salts and trading oil and greasy spots including two coats of wall care putty (average minimum 1mm thick) complete all as specified and directed. |
| 45 | M&L two coats of French polishing on New wooden surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler all as spd and directed. |
| 46 | M&L two coats of French polishing on Old wooden surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler all as spd and directed. |
| 47 | Earth work in surface excavation in all kind of soil not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m,including Clearing away all grass vegetation, saplings,shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area complete all as specified and directed. |
| 48 | M&L Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 49 | M&L 100mm thick PCC type B-2, (1:2:4) using 40mm graded stone aggregate as in floor etc complete all as specified and directed. |
| 50 | Providing and laying matt finished external vitrified tile of size 400x400x12mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc complete all as specified and directed. |
| 51 | Construction of reception cum security room including ATT, WPT, internal water supply, internal electric supply etc as shown in Drawing No. S-01,S-02, S-03, S-04,GE 01/04, 02/04,03/0404/04 and GE-01(Gate) complete all as specified and directed by Engineer-in-Charge. |
| 52 | S&F powder coated/pre painted Tensile car parking (size-21x 5mtr) with following specifications:- (a) MS Pillar of size 150mm outer dia and 2.8mm thick.(b) Pearing pillar of size 58mm outer dia and 2.5mm thick.(c) Other structural members of size 76mm outer dia and 2.8mm thick. (d) Total number of pillars - 7 Nos. (e) Fabric - Tensile fabric 800GSM blackout with minimum 7 years warranty. (f) All foundation work will be measured and paid separately under respective items. . |
| 53 | M&L Providing and laying in position cement concrete of 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) inluding the cost of centering and shuttering as in post holes complete all as specified and directed. |
| 54 | S&F Mild steel 16x600mm foundation bolt \"L\" shape ,85 HRC hardness for construction,16mm dia complete all as specified and directed. |
| 55 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W (GdeE-250)qualityAcomplete all as specified and directed. |
| 56 | Dismantling old plaster/grit plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed. |
| 57 | Material & Labour for 12mm thick cement plaster in CM 1:6(1 cement :6 fine sand) on brick or concrete surfaces finished even and fair complete all as specified and directed. |
| 58 | Material & Labour for 15mm thick cement plaster in two coats in CM 1:4 outer layer 5mm thickcomplete all as specified and directed. |
| 59 | Material & Labour for 12mm thick cement plaster in CM 1:3(1 cement :3 fine sand) on brick or concrete surfaces finished with a floating coat of neat cement mix on roof with water proofing compound complete all as specified and directed. |
| 60 | Material & Labour for 5mm thick cement plaster in CM 1:3(1 cement :3 fine sand) on fair faces of ceiling,chajjas,shelves andsurfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 61 | Supply only liquid water proofing compound complete all as specified and directed. |
| 62 | M&L two coats of 1st quality acrylic distemper on new ceiling surface over and including 1mm thick wall putty (average thickness not less than 1mm) complete all as specified and directed. |
| 63 | M&L Finishing walls with weather proof 100% acrylic smooth exterior emulsion paint of required shade in newly plastered surface of external wall and apply two coats applied @ 1.43ltr/10sqm over and including priming coat of exterior primer applied @0.90kg/10sqm complete all as specified and directed. |
| 64 | Dismantling tile work for thickness of tiles 10 mm to 25 mm in floors and roofs laid in cement mortar including stacking material within 50 metres lead complete all as specified and directed. |
| 65 | Providing and laying vitrified floor tiles 600x600x10mm with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete all as specified and directed. |
| 66 | S&F Frame size 65 x 125 mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profiledimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 67 | S& 30mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. Note: stainless steel butt hinges and necessary S.S screws shall be paid separately. |
| 68 | S&F 30mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain mosquito proof door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (face) & 900 N (edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. Note: stainless steel butt hinges and necessary S.S screws shall be paid separately. |
| 69 | Providing and fixing bright finished brass tower bolt (barrel type) with necessary screws etc.size 150x10mm complete all as specified and directed. |
| 70 | Providing and fixing chromium plated brass handles size 100mm with necessary screws etc complete all as specified and directed. |
| 71 | Providing and fixing ISI marked IS : 1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (copper oxidized as per IS: 1378) size 100x58x1.90 mm complete all as specified and directed. |
| 72 | Providing & fixing 4.0 mm thick glass panes with putty and glazing clips in steel doors, windows, clerestory windows, complete all as specified and directed. |
| 73 | Providing and fixing fly proof stainless steel grade 304 wire guage with 0.5mm dia wire and 1.4mm wide aperture with matching wood beading in wooden door or aluminium window shutter complete all as specified and directed. |
| 74 | M&L for wall cladding tiles in vertical surface 600 X 300 X 7mm thick set and jointed in neat cement slurry over and including 10 mm thick rendering in CM 1:3 and pointed in white or colour cement to match complete all as specified and directed. |
| 75 | Providing and laying non-pressure NP2 class R.C.C. pipes 150 mm dia. with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc complete all as specified and directed. |
| 76 | Material & Labour for 15mm thick cement plaster in two layers in CM 1:4 outer layer 5mm thick mixed with liquid water proofing compound@ 0.4% by the weight of cement including taking down old plaster complete all as spd and directed.Note :- Water proofing compound shall be paid separately. |
| 77 | M&L Providing and laying in position cement concrete of 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth levelcomplete as specified, supplied and fixed complete all as specified and directed. |
| 78 | Providing and fixing in position Pre-cast R.C.C. (LD 2.5) manhole cover and frame of required shape at site (size 900x450x75mm)) and approved quality including reinforcement and MS plate 2 mm thickall around the covers of size as per requirement at site complete all as specified and directed. |
| 79 | Taking down of Old unserviceable point wiring any type for light, fan, power etc includingunserviceable switch,socket, regulator and ceiling rose etc of any make complete including making good disturbed surfaces of walls, floors/roof etc complete all as specified and directed. |
| 80 | M&L for point wiring with PVC insulated unsheathed FRLSH wire 1.5 sqmm multi stranded two run single core copper conductor cable passing through in and including medium grade steel conduit pipe 25mm complete with all accessories and with 1.5 sqmm PVC insulated copper cable FRLSHas continuous earth wirewith recessed mounting GI sheet box with cover plate suitable for modular switch of adequate size including cutting chases in wall and making good the distrubed surface to match with the existing complete all as specified and directed for followings :- |
| 81 | (a)One light/ fan point controlled by one switch . |
| 82 | (b)One 3 pin socket outlet on independent board . |
| 83 | (c)One 3 pin socket outlet on same board . |
| 84 | All as per item No 80.00 here in before but for one socket point out let 3 pin 15 Amp with 2.5 sqmm PVC copper conductor FRLSH and 2.5 sqmm PVC insulated copper conductor FRLSH as earth continuity conductor. |
| 85 | S&F 05/06 Amp modular switch on the modular plate & switch box including connections but excluding modular plate etc. as required complete all as specified and directed.Note : The colour of Modular switch and frame should be match with existing wall panelling . |
| 86 | S&F 15/16 Amp modular switch on the modular plate & switch box including connections but excluding modular plate etc. as requiredNote : The colour of Modular switch and frame should be match with existing wall panelling . |
| 87 | S&Fmodular Socket outlet 3 pin 5/6 Amp including connections but excluding modular plate etc. as requiredNote : The colour of Modular socket and frame should be match with existing wall panelling |
| 88 | S&F modular Socket outlet 6 pin 15/16 Amp including connections but excluding modular plate etc. as required.Note : The colour of Modular Socket and frame should be match with existing wall panelling . |
| 89 | S&F ceiling rose, surface bakelite 65x50mm three terminals complete all as specified and as directed |
| 90 | S&F DLP trunking system plastic adoptable type 105x50mm with 2 compartment duly covered installed with suitable mosaic support joints including all accessories complete all as specified and as directed.Note : The colour of DLP trunking should be match with wall panelling. |
| 91 | S&F energy efficient LED light fitting surface mounted 4\" long, 20 watt, 240 volts, 50 hz made out of extrunded aluminium housing with acrylic diffuser, LM 80 certified LED, costant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 digree centigrade to 50digree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF>0.95 with efficiency 120 lumins/watt and TDH less than 10%, CRI > 90 digree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed. |
| 92 | S&F energy efficient LED light fitting, slim LED panel, recessed/surface mounting 600 mm x 600 mm made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF>0.95, high powder LEDs having efficiency of 100-120 lumens/watts, junction temperature less than 85 degree C and TH less than 12 % and CCT 6500K,, CRT>90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed.Add: Note -The colour of fittings should be match with false ceiling/ Paneling |
| 93 | S&F energy efficient, focus LED luminaire 10 watt with LED lamp for focus on roof ceiling 240 volts, 50 hz made out of extruded aluminum housing with acrylic diffuser, LM 80 certified LED, constant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 degree centigrade to 50degree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF>0.95 with efficiency 120 lumens/watt and TDH less than 10%, CRI > 90 degree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed. |
| 94 | S&F120 watt IP66 LED flood light comprising of pressure Die-Cast aluminum housing with weather proof gasket for lamp & driver compartment with system wattage of 120W with 120-degree view angle, > 120 lumen/watt, lumen maintenance >70% at 50,000 hrs, colour temperature of 5000-5700K,>70 color rendering and LM80 test compliance. The driver must be integral APFC and constant current type having THD <15% and power factor >0.95 with short circuit protection, open circuit protection, reverse polarity protection, high voltage protection, protection against 5 kV high surges and comply to IEC 60598-1, IEC 61000-3-2, IEC 61547. The luminaire must have secondary optics with perfectly matched lens for better light control. complete all as specified and directed. |
| 95 | S&F post top lantern Arian plus type 40 watt 230 volts, IP-67 outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 96 | S&F outdoor decorative type LED strip of multiple colour 75watt 240 volts, AC 50Hz, IP-65 with driver for outdoor applications suitable for lighting on wallincluding connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.Note:- Strip should be cut at marked interval to suit desired length. |
| 97 | S&F energy efficient, round shape 12 watt recessed /surface mounted240 volts, 50 hz made out of extruded aluminum housing with acrylic diffuser, LM 80 certified LED, constant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 degree centigrade to 50degree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF>0.95 with efficiency 120 lumens/watt and TDH less than 10%, CRI > 90 degree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed.Note:-The colour of fittings should be match with false ceiling/ Paneling |
| 98 | S&F adjustable type spot light suitable to adjust in different angles, 18 watt 220 volts AC recessed/ surface type, IP-65 with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Note :- The colour of fittings should be match with false ceiling/ Paneling. |
| 99 | S&F 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required complete all as specified and directed. |
| 100 | S&F 8 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required complete all as specified and directed. |
| 101 | S&F 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 6 to 32 Amps poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 102 | S&F 240V, 10 KA \"C\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 103 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) 1100 volt grade with stranded aluminium conductor of size 25 sqmm 4 core in trenches/wall/surface including saddles/thimbles complete all as specified and directed. |
| 104 | Supply and installation, commissioning of Desert air cooler,i-pure console with multistate filters, electric driven single phase 240 volts having approx. storage capacity 115 Liter of Make: Symphony Cat Part No SUMO115XL or equivalent in Usha/Havells. The product have fulfill the following specifications: -(a) Tank Capacity – 115 Ltr(b) Superior cooling with 3-side high efficiency honeycomb cooling pads.(c) Easy fill or hassle-free water filling(d) Clean air with i-pure technology having multistage filters.(e) Powerful fan with 28 ft air throw capacity.(f) Consumes 190 watt only(g) Manual control(h) Auto louver movement in virtually any direction to make surrounded by chilled air. |
| 105 | Excavation in trenches not exc 1.5 mtr wide and n. exc 1.5 m depth and getting out in soft/loose soil for laying UG cables of various sizes complete all as specified and directed. |
| 106 | Supply & laying clean and dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed.Note : Punned thickness shall be measured. |
| 107 | Supply and laying un-reinforced factory made precast concrete cable cover , class LV, type 1, flat size-250x180x40 mm complete all as specified and directed. |
| 108 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified anddirected. |
| 109 | Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level and not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 110 | Supply and laying GI pipe medium grade size 50 mm dia fixed on wall/laying in trench including all connected fitting/acessories including taking old unserviceable complete all as specified and directed. |
| 111 | M&L for Cutting of existing road/PCC/RCC/hard standing/removing tiles for laying of pipe including making good the disturbed surface to match with the adjoining surface with PCC 1:3:6type C2 complete all as specified and directed. |
| 112 | M&L of Wiring for circuit/submain wiring alongwith earth wire of FRLSH PVC insulated copper conductor,single core cable in recessed/ surface of size 2X6 sq mm + 1X4 Sq mm earth wire including suitable size ofsteel conduit and lugs/thimble with nuts,bollts and washers etc complete all as specified and directed. |
| 113 | S&F ceiling fan complete with blades, regulator, down rods accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 5.00 BEE. Five star rated with brushless direct current motor (BLDC) control with regulator including connection with 1.5 sqmm 3 core flexible copper cable complete all as specified and directed. |
| 114 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, Copper winding of sweep 300mm complete all as specified and directed. |
| 115 | M&L for earthing complete with MS galvanized plate of size 60 cm x 60 cm x 6 mm thick burried in ground vertically to a depth not less than 2.5 meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.copper plate connected with4 dia mm GI wire by means of nuts, bolts and washers.GI wire shall be laid in 40 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :-(a) 4 dia mm GI wire.(b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm diamild steel TMT bars suitable for carrying of pit cover. |
| 116 | S&F earth continuity conductor or main earthing lead fixed to wallor batten or recess or chases or burried in ground or drawn in coduit/ any other indicated situation for loop earthing etc.As required of 4mm dia GI wire complete as specified. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail