| 1 | B&R PORTION:Dismantling floor hearth and wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises complete all as specified and directed. |
| 2 | S&F prelaminated PVC rigid foam sheet wall panelling of 5 mm thick stuck on inner frame work of 35 mm wide strips of 5 mm thick rigid foam sheet. The strips should have a groove of 6 mm width and 2 mm depth for sinking the head of screw used to fix the strips to the all and should be placed vertically at equal intervals of 300 mm C/C. The PVC strips to be fixed to the all using 65 mm long MS screws through the groove in the strip by using PVC fasters incl moulding at columns, windows and doors jambs complete all as specified and directed.Note:-(a) Work for fixing of wall panelling shall be got executed through manufacturers authorised applicators only under the close supervision of their technical staff.(b) The entire qty of wall panelling and their allied ancillaries shall be procured directly from the manufacturer or their authorised dealer only. |
| 3 | M&L for GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced betweenmain \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings complete all as specified and directed. by Engineer-in-charge.Make :Diamond Ceilings/Armstrong/Knauf Ceiling/Durlum |
| 4 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius in CM 1:6 with old size bricks complete all as specified and directed. |
| 5 | Taking down cement or cement lime plaster any description including racking out joints, hacking for key, scrubbing down with water etc including removal of debris out side MoD land (The work shall be carried out upto sixth storey height of buildings) complete all as specified and directed. |
| 6 | M&L for 15 mm thick ready mix plaster on brick or concrete surfaces of wall in two layers (thickness of each layer not more than 10 mm finished even & smooth) The first layer shall be prepared as per manufacturer instructions, relevant IS code and Engineering practices. The complete work of this item shall be executed only by a skilled labour of the trade complete all as specified and directed by Engr-in-Charge |
| 7 | M&L for 5mm thick ready mix plaster READIPLAST RP of (Make Ultra tech) on any surfaces of brick/concrete includidng aapplication of bonding coat as Ultratech seal and Dry 5 Plus as per manufacturers instruction including finished even and smooth on soffits/ceiling surfaces (The work shall be carried out upto sixth storey height of buildings including all safety factor) complete all as specified and directed. |
| 8 | M&L for preparation of newly plastered surface of wall andapplying two coat of weather proof exterior emulsion extra premium 100% acrylic emulsion as approved over a coat of primer complete all as specified and directed by Engr in charge. |
| 9 | M&L for preparation of new plastered surface of wall andapplying two coats ofoil bound distemper over a coat of alkali resistant primer complete all as specified and as directed by Engr-in-Charge. |
| 10 | S&F Rolled Mild Steel Framed work as in doors or Gates of angle or other section confirming to Fe 410 -W, with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering and hanging and fixing (including necessary double steel scaffolding where required upto two storey bldg) complete all as specified and directed. |
| 11 | M&L for glazed ceremic tiles in vertical surface of size 450X300X7 mm on vertical Surfaces of wall on 10mm cement mortar 1:3 set and jointed in net cement slurry and pointed in white or colour cement to match complete all as specified and directed. |
| 12 | Taking down chowkhats or frame without taking off shutters n. exc 1.50 sqm complete all as specified and directed. |
| 13 | Taking down chowkhats or frame without taking off shuttersexc 1.50 sqm but n.exc 4.0 sqm complete all as specified and directed. |
| 14 | S&F powder coated aluminium window incl frame using 63 mm X 38 mm X 1.6 mm chowkhats with 48mm X 48 mm X 1.6mm openable section as in shutter , 5.5 mm thick glass panes of approved make with rubber for fixing glass and including builders hardware such as aluminium handles 100 mm -02 Nos, tower bolts 100 mm 02 Nos, butt hinges SS 100 mm 04 Nos etc complete all a specified and directed by Engr-in-Charge |
| 15 | S&F powder coated aluminum door using 96.6mm X 44.8 mm X 1.6 mm aluminium chowkhats 84.0 x44.7mmX1.6mm section vertical styles 101.60X44.88X1.6mm rails including mortice lock vertical type mild steel 100 mm size (Make : Godrej/Harrison) 02 Nos tower bolt 150 mm , door handles, SS butt hinges 125 mm 04 Nos, hydraulic door closer and fittings, bottom panel with 12 mm thick laminated Novapan and top panel with 5.5 mm thick plain glass fixed with snap beading rubber of suitable size complete all as specified and directed.Make of glass (MODI/FLOAT/ATUL) |
| 16 | S&F aluminium ornamantal grill 8mm dia 75x95mm aperture complete incl U channel complete all as specified and directed. |
| 17 | S&F powder coated aluminium sliding window shutters with frames (consisting of 02 Nos grazed shutters and 01No gauge shutter) series D(25mm), 3 track sliding shutters, duly fitted with neoprene beading glass 5.5mm nominal thickness in gazed shutters, stainless steel wire mess of 0.254 mm nominal dia of wire and 0.95mm average width of aperture in gauzed shutter, powder coated ornamental aluminium grill 8mm dia, 75 x 97 mm aerature fixed with standard aluminium beading fixed in outer portion of the chowkhat etc complete all as specified and directed. |
| 18 | M&L for 20 mm thickgranite (any type) stone machine cut bedded and jointed with grey cement slurry and pointed with white cement with pigment to match incl cutting and polishing over 20 mmthick screed in CM 1:6 in floors complete all as specified and directed. |
| 19 | S&F ZEBRAvenetian blinds horizontal type incl guide rail, pulling thread etc incl taking down existing pelmets. |
| 20 | S&F powder coated aluminium partition n.exc 1.20 Sqm in each panel using 95.6 mm x 44.8mm x 1.6mm frame work with 12 mm thick exterior grade veneered particle boards with decorative veneers on both faces/5.50 mm thick frosted glass including aluminium beading for fixing board complete all as specified and directed.Make: GLASS Make MODI/ FLOAT/ ATUL |
| 21 | M&L for mirror polishing on old surface of kota stone including rubbing polishing & treating the surface complete all as specified and directed.Note: Carborandum stone of 0 unit shall be used in polishing operation. |
| 22 | S&F door closer hydraulically regulated designation No 1 universal type, aluminum body suitable for door shutters of up to 700 mm in widthand weight not more than 35 Kg complete all as specified and directed. |
| 23 | E&M PORTION:Taking down carefully old point wiring with aluminium/ copper conductor (Light / Fan/ Socket/ power Point ) complete including fittings such as ceiling rose, pendent holders, regulators and socket point etc and making good the disturbed surface & wall/ floor complete all as specified and directed by Engr in charge. |
| 24 | M&L for point wiringwith PVC insulated unsheathedmulti strandedFRLS type copper conductor cable of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded FRLS type copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth dolly in and including PVC concealed conduit 20 mm dia medium grade ISI marked andits accessories including provn of new factory made pressed steel modular switch/terminal box of suitable size and new modular front & back plates of approved colour/model of suitable size for housing the modular switches, sockets, fan regulators for one light/ fan/ exhaust fan point controlled by one no, one way 5 Amp switch complete all as specified and directed.Note: (i)Cutting chases for concealed conduit and making good in cement mortar is deemed included in unit rate.(ii)No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring. In this specified portion wire shall run through the existing conduit or surface new conduit shall be provided as required.(iii) In case the wiring is encountered with any beam/column, then the wiring will run on surface to avoid any damage to the RCC portion. |
| 25 | All as per item No 24.00 above but for one light point controlled by two way 5 Amp switch complete all as specified and directed. |
| 26 | All as per item No 24.00 above but for One bell/buzzer point controlled by one bell push complete all as specified and directed. |
| 27 | All as per item No 24.00 above but for One 3 pin 5 Amp socket outlet on the same board complete all as specified and directed. |
| 28 | All as per item No 24.00 above but for One three pin 5 Amp socket outlet point controlled by one no, one way switch on independent board complete all as specified and directed. |
| 29 | All as per item No 24.00 above butwith 2 x 2.5 Sqmm +1 x 2.5sqmm Copper conductor cable for one 3 pin, 15 Amps Switch socket out let on independent board complete all as specified and directed. |
| 30 | S&F in repair modular switch flush type, 6 Amp. SP, one way ,1 module complete all as specified and directed.Make: Anchor/legrand/havells/CG/C&S/Indo asian/Gold Medal/ Panasonic/Schneider/Seimens |
| 31 | S&F in repair modular switch flush type, 6 Amp. SP, two way ,1 module complete all as specified and directed.Make: Anchor/legrand/havells/CG/C&S/Indo asian/Gold Medal/ Panasonic/Schneider/Seimens |
| 32 | S&F in repair modular bell push 6 amps complete all as specified and directed.Make: Anchor/legrand/havells/CG/C&S/Indo asian/Gold Medal/ Panasonic/Schneider/Seimens |
| 33 | S&F in repair modular socket outlet, 3 pin, 6 Amp, flush type 2 module complete all as specified and directed.Make: Anchor/legrand/havells/CG/C&S/Indo asian/ Gold Medal/ Panasonic/ Schneider/ Seimens |
| 34 | S&F in repair modularsocket outlet, 2/3 pin, 6/16 Amp flush type 2 module complete all as specified and directed.Make-Anchor/legrand/havells/CG/C&S/Indo asian/Gold medal/Panasonic/Schneider/Seimens |
| 35 | S&F in repair electric bell AC 230 Volt complete all as specified and directed by Engr in charge. |
| 36 | S&F in replacement of moduler Mini MCB SP 16-20 Amp,240V 3kA, C Curve, fitted in main switch board including 2.5 sqmm wire connecting socket & modular MCB complete all as specified and directed.Make -Havells/Legrand/L&T/C&S/Indo asian/Schneider/Siemens |
| 37 | S&F in repair modular AC BOX with 16-20 Amp mini MCB 230 Volts AC complete all as specified and directed.Make: Havells Cat Part No DHFNCSPA016, LK (L&T) cat part no. CB93101KW16, Schneider cat part no. P8016-N. |
| 38 | S&F in replacement of submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 4 sqmm completedrawn in new PVC concealed conduitand its accessories along with 1x 4 sqmm PVC insulated unsheathed copper conductor multi strandedFRLS type cable for continuous earth wire and duly connected to common earth dolly complete all as specified and directed.Make:-RR/Polycab/Havells |
| 39 | S&F in replacement of submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 10 sqmm completedrawn in new PVC concealed conduitand its accessories along with 1x 10 sqmm PVC insulated unsheathed copper conductor multi strandedFRLS type cable for continuous earth wire and duly connected to common earth dolly complete all as specified and directed.ake:-RR/Polycab/Havells |
| 40 | S&F in replacement for sheet metal enclosure TPN DB-VTPN 8 way 415V,double door,250 A copper bus bar, IP43,Suitable for 63-160Amp MCCB as incomer as flush mounted complete all as specified and as directed by Engr in charge.Make:-Havells/ Legrand /L&T /C&S/ Indoasian/ Schneider |
| 41 | S&F in replacement factory made sheet steel distribution boards, double door, SPN 12 way, concealed type, 240 volts AC with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing complete all as specified and directed. |
| 42 | S&F in replacement MCCB, 4 pole, 415 volt of capacity 80-100 amp, breaking capacity not less than 36 KA , Icu=100% Ics thermal magnetic type adjustable type80 to 100 % confirming to IEC-60947-II, IS-13947-II , including thimbles, nuts, bolts ,washers etc. and connections, replacement of thimbles, minor parts like nuts bolts washer etc. complete all as specified and directed by Engr in charge. |
| 43 | S&F in replacement MCB, SP 6 to 32 Amp current carrying capacity, 240V 10KA, B or C curve as per site reqt in the MCB DB complete with connection testing complete all as specified and directed. |
| 44 | All as per item No 43.00 above but MCB SP 40 Amps complete all as specified and directed. |
| 45 | All as per item No 43.00 above but MCB SPN 32 Amps complete all as specified and directed. |
| 46 | M&L in replacement plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4mm up to 7.50 RM bolted (with GI nuts, bolts & check nuts) and rivetedto earth (Plate) electrode at one end and connected to main switch board / test point (including test point) at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0using 12 mmgraded crushed stone aggregate, RCC cover, funnel, wire mesh etc including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified and directed by Engr in charge. |
| 47 | M&L in replacement plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25x4 mm up to 7.50 RM bolted (with GI nuts, bolts & check nuts) and rivetedto earth (Plate) electrode at one end and connected to main switch board / test point (including test point) at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0using 12 mmgraded crushed stone aggregate, RCC cover, funnel, wire mesh etc including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified and directed by Engr in charge. |
| 48 | S&F in replacment earth continuity conductor or main earthing lead fixed to wall on batten or reccess or chases or burid in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing as required 25x4 mm galvanised iron strip complete all as specified and directed by Engr in charge. |
| 49 | S&F Rigid non-metallic PVC conduit 25mm bore exclusive of boxes (junction/ terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed. |
| 50 | All as per item No 49.00 above but for size 40 mm bore complete all as specified and directed. |
| 51 | Taking down carefully LAN/telephone cables from existing conduit/casing capping and refixing the same including accessories such as couplers, lock nuts, saddles, pipe hooks etcand making good the disturbed surface & wall/ floor complete all as specified and directed. |
| 52 | S&F in replacementLED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.Make:- Philips/Havells/bajaj/crompton |
| 53 | M&L for taking down of existing AC window type or split type and refixing the the same at its original position along with complete accessories including minor repiars and repair of PCB/ display, making good surface od disturbed area at wall complete all as specified and directed. |
| 54 | Supply and installation, testing and commissioning of hard drawn copper refrigerant pipes of size 6 mm ( 1/4\" ) thickness for AC units with necessary copper fittings, laid neatly, secured with GI clamps and wall brackets with pipe supports as per technical specifications, at every 1.5 meter interval and at bends including insulation with 19 mm thick class \"O\" nitrile rubber, UV treatment (coating) for exposed refrigerant piping insulation all as required at site as per specifications, complete all as specified and directed by Engr in charge. |
| 55 | All as per item No 54.00 above but for size 9 mm ( 3/8\" ) thickness complete all as specified and directed. |
| 56 | All as per item no 54.00 above but for size 13 mm ( 1/2\" ) thickness complete all as specified and directed. |
| 57 | All as per item No 54.00 above but for size 16 mm ( 5/8\" ) thickness complete all as specified and directed. |
| 58 | S&F PVC drain pipes threaded 32 mm dia and fith clamps at every 1 m along with bends and maintaining slope complete all as specified and directed by Engr in charge. |
| 59 | S&F in repair GI Raceway made from 1.5mm thick pregalvanized sheet for top,bottom & sides and complete with top cover with rubber gasket of size 100x38mm complete for mounting and supporting the cable tray system,along with vertical bends, including taking down and re fixing and type of electric/signal cable, if require through wall/floor cutting and making good surface of disturbed area, complete all as specified and directed. |
| 60 | S&F in repair GI bracket for raceway mentioned in above item here-in-before of 100mm width, complete all as specified and directed. |
| 61 | S&F in repair coupler for raceway of 100 mm width complete all as specified and directed. |
| 62 | S&F in repair PVC duct cable tray/ wiring channels for top,bottom & sides and complete with top cover with rubber gasket of size 100x100mm complete for mounting and supporting the cable tray system,along with vertical bends, including taking down and re fixing and type of electric/signal cable, if require through wall/floor cutting and making good surface of disturbed area, complete all as specified and directed. |
| 63 | All as per item No 62.00 above but for size 100x50mm complete all as specified and directed. |
| 64 | Supply & Charging of R407/R410 refregerent gas complete all as specified and directed. |
| 65 | M&L for taking down of existing LT panel and refixing the the same at its original position along with complete accessories making good surface old disturbed area at wall complete all as specified and directed. Note: (a) Srl Item No 02.00 to 04.00, 06.00, 10.00, 11.00, 14.00, 15.00, 17.00 to 19.00, 24.00, 38.00 to 41.00, 52.00 & 59.00 of BOQ are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody.(b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge. |