| Sl. No. | Item Description |
| 1 | M & LDouble charged Light shade/ Dark shade vitrified tiles of size 600 mm x 600 mm and 8-10 mm thick following the specifications as per IS 15622-2006, cut to required size set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles as in floor incl screed bed or bedding layer of mortar 15 mm thickin CM 1:4for laying of floor tiles incl dismantling of floor tiles including bedding (but not backing), and rubbish off premises or removed to store complete all as specified and directed. |
| 2 | M&L for 16 mm thick granite slab, polished as mirror finish without any hairline crack, as in cooking platforms, steps, window cills, incl proper edge moulding & cutting holes for gas pipe through drill machine and like in cement mortar (1:4) including pointing in coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl dismantling and rubbish off premises or removed to store complete all as specified and directed. |
| 3 | M&L for Non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles incl screed bed or bedding layer of mortar 15 mm thickin CM 1:6for laying of floor tiles incl dismantling of floor tiles including bedding (but not backing), and rubbish off premises or removed to store complete all as specified and directed. |
| 4 | M&L for Non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles incl screed bed or bedding layer of mortar 15 mm thickin CM 1:6for laying of floor tiles incl dismantling of floor tiles including bedding (but not backing), and rubbish off premises or removed to store complete all as specified and directed. |
| 5 | M&L for Glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surfaces such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over incl rendering 10 mm thick in cement mortar 1 : 4for fixing of wall tiles incl dismantling of wall tiles & rendering upto wall surface and rubbish off premises or removing to store complete all as specified and directed. Note:- (a) The rates include for all straight cutting and waste. Raking or circular cutting and waste shall be measured separately.(b) The rates for glazed tiles include for laying to any pattern with one or more colours as directed.(c) If tiles of different sizes are used then no price adjustment shall be done. |
| 6 | M&L for Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand incl dismantling of old paver block and rubbish off the premises or removing to store complete all as specified and directed. |
| 7 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required incl demolition of old unreinforced kerb stone complete all as specified and directed. (Note :-Rates include for all cutting and waste and work in all positions as well as in narrow widths.) |
| 8 | M&Lfor PCC 1:2:4type B-0using 12.50 mm graded aggregate as in sub-base flooring25 mm thick surface finishedeven and rough to receive the topping layer incl demolition of old unreinforced sub base pcc complete all as specified and directed.Note :- The rates of cement concrete in flooring include for:(i) Use and waste of form work/screed strips and to divide the area in panels. (ii) Finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc.even and rough to receive the topping layer.(iii) Finishing exposed edges fair or rounding or chamfering of exposed edges, where directed.(iv) Laying concrete in narrow widths, risers, treads, landings and the like. |
| 9 | M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor incl demolition of old unreinforced sub base pcc complete all as specified and directed. Note :-The rates of cement concrete in flooring include for:(i) Use and waste of form work/screed strips and to divide the area in panels. (ii) Finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc.even and rough to receive the topping layer.(iii) Finishing exposed edges fair or rounding or chamfering of exposed edges, where directed.(iv) Laying concrete in narrow widths, risers, treads, landings and the like. |
| 10 | M&L for preparation of new or previously untreated concrete surfaces of any description over 10 cm girth or width not otherwise described and applying two coats of Plastic emulsion paint over priming paints plaster coat complete all as specified and directed. |
| 11 | M&L for Preparing surface including cleaning the concerned RCC surface by means of wire brush to expose the concrete surface which should be free from all loose particles, dust, laitance, etc of sunken slab and applying 15 mm thick cement plaster 1:4 cement sand mortar with integral water proofing compound both on floor and wall.The surface shall then be cured and allowed to dry then applying Epoxy Resin coating polymer modified cementitious coating like brush bond of Fosroc, Pidilite and Bostic as per manufacturer\"s instructions both on floor as well as on wall and sunken floor shall be filled with graded cinder as per requirement of site complete all as specified.Note : The Rates includes for (a) Thickness of plaster key in joints, etc.(b) Arrises, chamfers of any width, internal rounded angles upto 80mm in width or girth external rounded angles upto 80mm in width or girth, except in thecase of mud plaster and leeping where angles etc. of any girth are included.(c) All labour and equipment necessary for incorporating integral waterproofing compound in the manner specified by the manufacturer and in the proportions indicated. The rates do not include for supply of integral waterproofing compound, which if supplied by the Contractor, shall be measured separately and paid for at “Supplied only\" rates.(d) Scoring surface of plastering for key, where the surface is not required to be finished fair.(e) Curing of plastered surface.(f) Cleaning stains and dripping mortar from floors and walls, etc. (g) Making corner fillets with Polymer modified cementitious (PMC) mortar (PMC:C:M :: 1:2:4 by weight) at all joints of horizontal and vertical surface and doing bore packing with PMC mortar(h) Joints of pipes and concrete/masonry are to be sealed with epoxy putty or epoxy mortar (PMC:C :: 1:2 by weight) and the same is semi-rounded upto 5mm above surface level all along the periphery of PVC pipes. |
| 12 | M&L for PCC 1:3:6 type C-2 using 40mm graded brick coarse aggregate as in sunken floors incl demolition of old sunken floor in neat and clean stage etc complete all as specified and directed.(Note :- (a) The quantity of concrete shall be taken as the net volume only of finished work. (b) Rates for cement concrete made with brickcoarse aggregates are applicable for volumetric mixes only.) |
| 13 | M&L Modular Brick work with Fly Ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 incl demolition of old brick work or stone/ boulder masonary built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed.Note :-(a) Picking, cleaning, sorting out etc. small articles such as wall ties, clamps, holding down bolts etc. not exceeding 3 kg each, which come out as a result of demolition.(b) Temporary shoring for the safety of portions not required to be pulled down, or of adjoining property, and providing temporary enclosures or partitions, where considered necessary by EIC.(c) Taking all necessary precautions for the protection of the public property and to keep down dust nuisance etc.(d) Any necessary disconnection of services, whether temporary or permanent as directed by EIC; any making good shall be measured separately. (e) No payments shall be made for any extra lead, when with the approval of the G.E., the unserviceable materials are removed by the Contractor for his ownuse, nor will any deduction be made for any value, they may have. (f) All coping’s, corbels, cornices and other projections shall be included with the wall measurements.(g) The rates include taking down walls, etc, with plaster but the measurements will be exclusive of plaster thickness. In case of pavings and floors the rates include for removal of bedding layer.(h) Honeycomb brickwork and hollow concrete blocks shall be measured solid.(i) Fly ash bricks shall be burnt clay flyash building bricks as per IS- 13757 with class designation 75 (Kgf/cm2) |
| 14 | M&L for Removing building materials etc. to a distance of 400 m to 500 m, including loading, unloading and stacking at the destination complete all as specified and directed. (Note :- Removal is to be done by the shortest practicable route and measurement shall be made accordingly, irrespective of the route actually taken. No additional price shall be allowed for roads in bad repairs, gradients or removal over unconsolidated ground.) |
| 15 | M&L 75 mm thick PCC 1:3:6 type C-1 using 20mm graded aggregate as in plinth protectionfinishing even & smooth without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 gde and three part of sand ( all by weight)incl demolition of old unreinforced plinth protection complete all as specified and directed.Note :- The rates of cement concrete in flooring include for:(i) Use and waste of form work/screed strips and to divide the area in panels. (ii) Finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc.even and rough to receive the topping layer.(iii) Finishing exposed edges fair or rounding or chamfering of exposed edges, where directed.(iv) Laying concrete in narrow widths, risers, treads, landings and the like. |
| 16 | M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like, landings,chajjas, shelves and similar articles with plain faces includingchamfered, weathering, throating etc. and set in cement mortar (1:4) slightly rounded or chamfered angles incl demolition of old unreinforced pcc complete all as specified and directed. (Note :- (a) The rates include for use of formwork (straight or curved). (b) Concrete items if so indicated, shall be reinforced. Reinforcement shall be measured separately.) |
| 17 | M&L for Pre-cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregateas in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match set in CM 1:4 incl demolition of old reinforcement cement concrete (Reinforcement cut as required to facilitate demolition) complete all as specified and directed. (Note :- (a) The rates include for the use of forms, moulds or machine moulds and setting the blocks, slabs, etc. complete including raking back the joints of the internal faces (at least 10 mm) for pointing as the work proceeds or finishing with neat flush joints. (b) Precast cement concrete item shall be reinforced, where indicated. Reinforcement shall be measured separately.) |
| 18 | M&L Mild Steel TMT bar 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.90mm dia or securing with clips complete all as specified and directed. (Note :- (a) The rates include for fixing and for bracing, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it. Rates also include for straightening where reinforcement is supplied in rolls/coils.) |
| 19 | M&L Rendering on fair faces of brick work or concrete surfaces of wall 15 mm thickin CM 1:6 and to be finished even and smooth without using extra cement incl taking down old cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified and directed. Note :-The Rates includes for (a) Thickness of plaster key in joints, etc.(b) Arrises, chamfers of any width, internal rounded angles upto 80mm in width or girth external rounded angles upto 80mm in width or girth, except in thecase of mud plaster and leeping where angles etc. of any girth are included.(c) Scoring surface of plastering for key, where the surface is not required to be finished fair.(d) Curing of plastered surface.(e) Cleaning stains and dripping mortar from floors and walls, etc. |
| 20 | M&L Rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces,second layer (finishing coat)mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer\"s instructions and finish the surfaces even and smooth without using extra cement incl taking down old cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified and directed. Note (i):-(a) Liquid WPC will be measured and paid separately. Note(ii) :-The Rates includes for (a) Thickness of plaster key in joints, etc.(b) Arrises, chamfers of any width, internal rounded angles upto 80mm in width or girth external rounded angles upto 80mm in width or girth, except in thecase of mud plaster and leeping where angles etc. of any girth are included.(c) All labour and equipment necessary for incorporating integral waterproofing compound in the manner specified by the manufacturer and in the proportions indicated. The rates do not include for supply of integral waterproofing compound, which if supplied by the Contractor, shall be measured separately and paid for at “Supplied only\" rates.(d) Scoring surface of plastering for key, where the surface is not required to be finished fair.(e) Curing of plastered surface.(f) Cleaning stains and dripping mortar from floors and walls, etc. (g) Use of all scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. |
| 21 | M&L Rendering 5 mm thick in cement mortar 1:3 on concrete surfaces of ceiling and finishing the surfaces even and smooth incl taking down old cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified and directed. Note :-The Rates includes for (a) Thickness of plaster key in joints, etc.(b) Arrises, chamfers of any width, internal rounded angles upto 80mm in width or girth external rounded angles upto 80mm in width or girth, except in thecase of mud plaster and leeping where angles etc. of any girth are included.(c) Scoring surface of plastering for key, where the surface is not required to be finished fair.(d) Curing of plastered surface.(e) Cleaning stains and dripping mortar from floors and walls, etc. |
| 22 | M&L for applying 1mm thick white cement based putty conforming IS 17545 : 2001 on newly plastered surfaces or on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper and applying two coats of water based acrylic distemper on wall or concrete over a coat of distemper primer applied by roller or any mechanical means on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 23 | M&L for complete removal of existing treatmentby brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and grease spots, washing rubbing down and stopping of distempered and painted surfaces and applying two coats of water based acrylic distemper over a coat of distemper primer on wall applied by roller or any mechanical means complete all as specified and directed. |
| 24 | M&L for applying one coat of water based acrylic distemper on walls applied by roller or any mechanical means on prepared surfacescomplete all as directed. |
| 25 | M&L for preparation of newly plastered surfaces or old decorated plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of lime wash conforming to IS 6278 : 1971 complete all as specified and directed. |
| 26 | M&L for applying one coat of lime wash on old walls on prepared surfaces complete all as specified and as directed. |
| 27 | M&L for preparation of newly plastered surfaces or old decorated plastered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of lime wash conforming to IS 6278 : 1971 complete all as specified and directed. |
| 28 | M&L for applying one coat of lime wash on old ceilings on prepared surfaces complete all as specified and as directed. |
| 29 | Material & Labour for applying two or more coats of Water based latex polymer dispersed vinyl emulsion paint having VOC less than 30 gm/litre and conforming to IS 15489:2004,UV resistance, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives between 0.90% to 1.10% by weight of paint over and including priming coat of acrylic cement exterior primer over new surfaces or old surfaces including complete removal of existing treatment complete all as specified and directed. |
| 30 | Material & Labour for applying two or more coats of Water based latex polymer dispersed vinyl emulsion paint having VOC less than 30 gm/litre and conforming to IS 15489:2004,UV resistance, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives between 0.90% to 1.10% by weight of paint over and including priming coat of acrylic cement exterior primer incl 1 mm thick acrylic wall putty over new surfaces or old surfaces including complete removal of existing treatment complete all as specified and directed. |
| 31 | Material & Labour for applying one coat of Water based latex polymer dispersed vinyl emulsion paint having VOC less than 30 gm/litre and conforming to IS 15489:2004,UV resistance, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives between 0.90% to 1.10% by weight of paint over and including priming coat of acrylic cement exterior primer incl preparation of old surfaces complete all as specified and directed. |
| 32 | M&L apply two coats (second coat should be applied perpendicular to the first one) of fiber reinforced elastomeric liquid (Damp proof) formulated with select elastomeric and resilient acrylic polymers and reinforcing synthetic fibers over one coat of primer using roller all as specified and directed as manufacturer instruction complete all as specified and directed. |
| 33 | The rates (from Sch Item- 22 to Item - 32) include for:(a) Use of all scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.(b) Removing of nails, making good holes, cracks, etc.(c) Work in patches, and in narrow \widths. bands, cornices, pilasters, etc. and cutting in edges to line, where necessary.(d) Spreading and removing coverings to doors, windows, floors, fittings, etc., to protect them from splashes.(e) Removing and replacing furniture, movable cupboard, chicks, blinds, etc.(f) Washing floors, cleaning glass, joinery, electric fittings, wiring, etc. of drops and splashes and leaving premise, clean and tidy. |
| 34 | Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 35 | Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 36 | Taking down shutter of any description area exceeding 1 sqm but n exc 2 sqm each and removing to store complete all as specified and directed. |
| 37 | Taking down shutter of any description area not exceeding 1 sqm each and removing to store complete all as specified and directed. |
| 38 | M&L Second class hard woodplain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. (Note :- The rates include for hardwood and rebated holes for hold fasts, bolts or screws including pelletting to heads.) |
| 39 | M&L Cutting holes in brick walls exc half brick but not exc one brick built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed. (Note :- (i) The rates do not include cost of holdfasts which shall be measured separately. (ii) ‘Making good’ includes for making good with serviceable old/new bricks/stone to match the adjoining work. (iii) The contractor may dismantle brickwork as alternative to cutting at his option. In that case he will make good with serviceable old/new brick to match with adjoining work. The rate shall include the above element.) |
| 40 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. (Note :- The rates include for riveting and/or welding as directed and fixing with screws, bolts, etc. complete) |
| 41 | S & F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube supplying & fixing in opening as per specified and shown on drawing made on section 8 of SSR 2020 Part-II complete all as specified and directed. (Note : - (i) Solid PVC Door Frame of the size 50 x 47mm made out of 5mm PVC sheet. The door profiles are to be reinforced with 19xl9 mm M.S. Square tube. EPDM rubber gasket weather seal to be provided through out the frame. The profile shall be mitre cut at two corners and joined by inserting 2nos. of 150mm long brackets of 15x15mm M.S. square tube inside the 19mm x 19mm M.S. square tube and suitably screwed.) |
| 42 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C\" channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing in section 8 of SSR-2020 part-II complete all as specified and directed. |
| 43 | S&F Window Shutters of second class hard wood 30 mm thick factory made glazed and skeleton shutters, open rebated and prepared to receive glass , gauze etc with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) complete all as specified and directed. Note :- The rates include for :(a) Nails, screws, wedges and keys as required.(b) Hardwood or bamboo pins to framed joints.(c) Coating framed joints with glue before being put together.(d) Punching and clenching nails.(e) Planing on all sides unless described as clean sawn.(f) Providing shutters in one leaf or more leaves, as directed.(g) All extra work due to diminished stiles, if directed.(h) Sand papering to an even and smooth texture.(i) Fitting of shutters to chowkats (and fixing in the case of fixed shutters) and preparing for hanging, sliding, etc. All builder’s hardware including hinges, pivots, etc. shall be measured in addition, as ‘supplied and fixed’.(j) Glass or wire cloth, etc. in panels or sash squares shall be measured separately. |
| 44 | S & F 35 mm thick second class hard wood rail and style plain, framed, factory made panelled shutters (Two panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and stiles are as per IS – 1003 (Part – I), kiln seasoned & chemically pressure treated complete all as specified and directed. Note :- The rates include for :(a) Nails, screws, wedges and keys as required.(b) Hardwood or bamboo pins to framed joints.(c) Coating framed joints with glue before being put together.(d) Punching and clenching nails.(e) Planing on all sides unless described as clean sawn.(f) Providing shutters in one leaf or more leaves, as directed.(g) All extra work due to diminished stiles, if directed.(h) Sand papering to an even and smooth texture.(i) Fitting of shutters to chowkats (and fixing in the case of fixed shutters) and preparing for hanging, sliding, etc. All builder’s hardware including hinges, pivots, etc. shall be measured in addition, as ‘supplied and fixed’. |
| 45 | S&F Door Shutters of second class hardwood 35 mm thick factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc without sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part I section 8 clause 8.24 (a) complete all as specified and directed.Note :- The rates include for :(a) Nails, screws, wedges and keys as required.(b) Hardwood or bamboo pins to framed joints.(c) Coating framed joints with glue before being put together.(d) Punching and clenching nails.(e) Planing on all sides unless described as clean sawn.(f) Providing shutters in one leaf or more leaves, as directed.(g) All extra work due to diminished stiles, if directed.(h) Sand papering to an even and smooth texture.(i) Fitting of shutters to chowkats (and fixing in the case of fixed shutters) and preparing for hanging, sliding, etc. All builder’s hardware including hinges, pivots, etc. shall be measured in addition, as ‘supplied and fixed’.(j) Glass or wire cloth, etc. in panels or sash squares shall be measured separately. |
| 46 | Hacking out old broken glass (any thickness, size quality or description) form wooden frames or stone, concrete or brick surrounds glazed with oil putty or fixed with beads complete all as specified and directed. |
| 47 | Hacking out old broken glass (any thickness, size quality or description) form from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed. |
| 48 | S&F 3 mm thick sheet glass ordinary quality and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 49 | S&F 3 mm thick figured glass pin headed type and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 50 | S&F 5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. (Note : The Glass may be transparent or tinted as approved by GE) |
| 51 | S&F 5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed. (Note : The Glass may be transparent or tinted as approved by GE) |
| 52 | S&F 5 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 53 | M&L for Securing glass of any description in existing wooden frames glazed with putty/ beads including removing loose or decayed putty/ beads, painting/oiling one coat on rebates, grooves, reputtying and painting/oiling puttied surface to match existing work complete all as specified and directed. |
| 54 | M&L for Securing glass of any description in existing metal frames glazed with beads including removing loose or decayed beads, painting/oiling one coat on rebates, grooves, reputtying and painting/oiling puttied surface to match existing work complete all as specified and directed. |
| 55 | S & FPowder coated aluminium sliding glazedwindows with three track shutter sliding (two shutters glazed and one shutterwire mesh) shall be two part as upper patr shall be three movable shutterand lower part consist three shutter (one openable in centre and both side fixed type shutter with frosted glass) with following specification and making good the adjacent side of jombs of windows by plastering in CM1: 3 even and smooth complete etc . shifting of existing cooler stand where required complete all as specified and as directed by Engr-in-charge.(i)Windows frame of cross section 101mm x 44mm x 1.5mm thick. (Min)(ii)Three way track for sliding shutters of cross section91.8mm x 31.75mm x1.1mm thick.(Min)(iii)Sliding shutter frame of cross section40 x 18 x 1mm thick.(Min)(iv)4 mm thickglass superior quality.(Min)(v) IDPE Rubber guasket for fixing of glass.(vi)Locking cleats per shutter -01 Nos.(Min)(vii)Sliding rollers per shutter - 02 Nos.(Min)(viii) Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples for shutters 01 Nos.(Ix)fixing screw for frame with wall per windows- 08 Nos.Note : Fabrication of aluminum door shall be done by authoried fabricator. |
| 56 | S&F Powder coated aluminium ventilator cross section 63.50 mm x 38.10 mm x 1.50 mm consisting of two portions upper portion shall have louvers with 3 mm thick pin headed glass and aluminium wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.40 mm fixed with aluminium beads and securing on outer face of frame and lower portion of ventilator shall be fixed with 3 mm thick pin headed glass with IDPE rubber gasket including aluminium beads including prepartion of jambs all around in CM 1:3 finishing even and smooth complete all as specified and directed. |
| 57 | M&L for Fe 410-W (Gde E-250 quality A) Framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete,drilled for fixing of steel sheeting or other covering. Doors,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing incl dismantling wrought iron or mild steel work of any description complete all as specified and directed. (Note :- (a) The rates allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. (b) The rates also include for drilling the members for site connections.) |
| 58 | S&F in repairs Mild Steel Plain Sheet 1.60 mm thick in Wall Cladding, Steel Gates and Similar Work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing and plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc as required complete all as specified and directed. (Note :-The rates include for all cutting and waste. Supports, clamps, stays, etc. for securing shall be measured separately.) |
| 59 | S&F Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed. |
| 60 | S&F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165incl dismantling wrought iron or mild steel work of any description complete all as specified and directed. (Note :-The rates include for riveting and/or welding as directed and fixing with screws, bolts, etc. complete) |
| 61 | M&L for cleaning and preparing the surfaces to be welded together, holding the members in true position while welding and bevelling of edges, thickness of metal to be welded exc 3 mm but n exc 6 mm complete all as specified and directed. (Note : The rate includes taking down the article and refixing in position after welding ) |
| 62 | M&L for cleaning and preparing the surfaces to be welded together, holding the members in true position while welding and bevelling of edges, thickness of metal to be welded exc 6 mm but n exc 9 mm complete all as specified and directed. (Note : The rate includes taking down the article and refixing in position after welding ) |
| 63 | M&L for Fe 410-W (Gde E-250 quality A) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etcincl dismantling wrought iron or mild steel work of any description complete all as specified and directed. (Note :- (a) The rates allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. (b) The rates also include for drilling the members for site connections.) |
| 64 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240incl dismantling wrought iron or mild steel work of any description complete all as specified and directed. (Note :- (a) The rates allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. (b) The rates also include for drilling the members for site connections.) |
| 65 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws incl dismantling of old sheet of any description and removing to store complete all as specified and directed. |
| 66 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush shutters of thickness 18/19 mm thick for cupboards/ wardrobes etc complete all as specified and directed. (Note :(i) It comprises virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. (ii) WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter all as per direction of Engineer- In- Charge. (iii) Fitting of shutters to chowkats (and fixing in the case of fixed shutters) and preparing for hanging, sliding, etc. All builder’s hardware including hinges, pivots, etc. shall be measured in addition, as ‘supplied and fixed’.) |
| 67 | S & F Continuous (piano) hinges of brass with width of flaps (when open) 40 mm complete all as specified and directed. |
| 68 | S&F 125 mm Hasp and staple, safety type, Aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws omplete all as specified and directed. |
| 69 | S&F 100 mm size Rim latch with two levers, of brass body, polished bright. stove enamelled finish; with brass knob or lever handle and fixed |
| 70 | S&F 2-lever Locks, drawer, grade I, size 75 mm of brass complete all as specified and directed. |
| 71 | S&F Brass Drawer pulls, 3 screw plate with fixed dished pull; 80 mm to 100mm long complete all as specified and directed. |
| 72 | S&F Ball catches (Magnetic catcher) with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed. |
| 73 | S&F in repairs Brass Hat and coat hooks, solid body, 175mm to 250 mm as approved complete all as specified and directed. |
| 74 | S&F in repairs Brass Wardrobe hooks (single) 50mm to 60mm as approved complete all as specified and directed. |
| 75 | M&L Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 for 75 mm long complete all as specified and directed. |
| 76 | M&L Butt hinges, extruded aluminium alloy with galvanised mild steelhinge pin, anodised and fixed, type B-21 for 100 mm long complete all as specified and directed. |
| 77 | S&F Aluminum alloy anodised sliding door bolts with hasp & staple (Bolt type) and fixing clips of sheet,cast extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy of 300 mm length of bolt complete all as specified and directed. |
| 78 | S&F Aluminium anodised barrel tower bolts of extruded section 150 mm long complete all as specified and directed. |
| 79 | S&F Aluminium anodised barrel tower bolts of extruded section 200 mm long complete all as specified and directed. |
| 80 | S&F 100 mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 81 | S&F 150 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed. |
| 82 | S&F 200 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed. |
| 83 | S&F Floor door stopper 140 mm overall length of cover plate of aluminium alloy body and tongue, anodised. With hard drawn spring, fixed in floor. complete as directed by Engr-in-charge |
| 84 | S&F Mild steel, 300 mm long ordinary helical door spring incl roller and roller plate including welding to Iron door shutter complete all as specified and directed. |
| 85 | Taking down and Refixingin the same opening shutters of any description not exceeding 1.00 Sq.m each after easing and adjusting complete all as specified and as directed. (Note :- The item for \"refixing\" includes taking down, easing and adjusting and also refixing new builders hardware as required including renewal of unserviceable screws, etc. Renewal of builder\"s hardware shall be paid separately as \"supplied and fixed in repairs\".) |
| 86 | Taking down and Refixingin the same opening shutters of any description exceeding 1.00 Sq.m and not exceeding 2.00 Sq.m each after easing and adjusting complete all as specified and as directed. (Note :- The item for \"refixing\" includes taking down, easing and adjusting and also refixing new builders hardware as required including renewal of unserviceable screws, etc. Renewal of builder\"s hardware shall be paid separately as \"supplied and fixed in repairs\".) |
| 87 | S&F in repairs Aluminium anodised barrel tower bolts of extruded section 150 mm long complete all as specified and directed. |
| 88 | S&F in repairs Aluminium anodised barrel tower bolts of extruded section 200 mm long complete all as specified and directed. |
| 89 | S&F in repairs Aluminium alloy anodised Sliding Door Bolt with hasp and staple (Bolt Type) of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 90 | S&F in repairs Aluminium alloy anodised Sliding Door Bolt with hasp and staple (Bolt Type) of size 250 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 91 | M&L in repairs Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 for 75 mm long complete all as specified and directed. |
| 92 | M&L in repairs Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 for 100 mm long complete all as specified and directed. |
| 93 | S&F in repairs 150 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed. |
| 94 | S&F in repairs 200 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed. |
| 95 | S&F in repairs125 mm Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws omplete all as specified and directed. |
| 96 | S&F in repairs Small fittings of 2nd class hardwood such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like not exc 200 cu. cm each complete all as specified and directed. |
| 97 | S&F in repairFloor door stopper of aluminium alloy body and tongue, anodised, over all length of cover plate 140 mm with hard drawn steel spring fixed in door etc complete all as specified and directed. |
| 98 | S&F in repairs 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 99 | S&F in repairs aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples in iron door shutter/ Aluminium Window shutter or any type of wooden glazed shutter complete all as specified and directed. |
| 100 | S&F in repairs Door seal with aluminium beading and 50 mm wide rubber sealcomplete fixed to aluminium/ Wooden doors complete all as specified and directed. |
| 101 | M&L for preparation of new wooden surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 102 | M & L for preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 103 | M & L for preparation of new steel surfaces any description n exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 104 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in floors, trenches incl taking down of old eave gutters and rainwater pipes of any size or pattern including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store complete all as specified and directed. |
| 105 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wallincl taking down of old eave gutters and rainwater pipes of any size or pattern including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store complete all as specified and directed. |
| 106 | S&F PVC (SWR) pipes 150mm bore single socketed in any length with rubber ring joints fixed to wallincl taking down of old eave gutters and rainwater pipes of any size or pattern including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store complete all as specified and directed. |
| 107 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in floors, trenchesincl taking down of old eave gutters and rainwater pipes of any size or pattern including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store complete all as specified and directed. |
| 108 | S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to wallsincl taking down of old eave gutters and rainwater pipes of any size or pattern including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store complete all as specified and directed. |
| 109 | S&F Stack clamps made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 150 mm PVC pipe complete all as specified and directed. |
| 110 | S&F Stack clamps made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 110 mm PVC pipe complete all as specified and directed. |
| 111 | S&F Stack clamps made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 75 mm PVC pipe complete all as specified and directed. |
| 112 | S&F PVC(SWR) bends, any radius of 110 mm bore without access door complete all as specified and directed. |
| 113 | S&F PVC(SWR) bends, any radius of 150 mm bore without access door complete all as specified and directed. |
| 114 | S&F PVC(SWR) bends, any radius of 110 mm bore with access door complete all as specified and directed. |
| 115 | M/L PVC(SWR) Tee of110mm dia etc complete all as specified and directed. |
| 116 | S&F PVC(SWR) bends, any radius of 75 mm bore without access door complete all as specified and directed. |
| 117 | S&F PVC(SWR) bends, any radius of 75 mm bore with access door complete all as specified and directed. |
| 118 | S&F PVC (SWR) branch pieces, single (equal or un equal) , ordinary or inverted (spigot or socket type) or with parralled branches of 110 mm dia with access door complete all as specified and directed. |
| 119 | S&F PVC (SWR) branch pieces, single (equal or un equal) , ordinary or inverted (spigot or socket type) or with parralled branches of 75 mm dia with access door complete all as specified and directed. |
| 120 | S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed. |
| 121 | S&F PVC (SWR)Floor trap of diameter of outlet 75 mm, plain with gratingincluding jointing with solvent cement 75mm dia etc complete all as specified and directed. |
| 122 | S&F PVC (SWR)Floor trap of diameter of outlet 110 mm, plain with gratingincluding jointing with solvent cement 75mm dia etc complete all as specified and directed. |
| 123 | S&F PVC (SWR) \"P\" trap for 110 mm dia etc complete all as specified and directed. |
| 124 | S&F PVC (SWR) \"S\" trap for 110 mm dia etc complete all as specified and directed. |
| 125 | The rates (from Sch Item- 103 to Item - 123) include for:(a) The measurement of pipes shall be net as fixed between the fittings including short lengths, without any allowance for cutting and waste or for the portions of pipes entering the sockets of the adjacent pipe or fitting. Fittings and accessories such as bends, branches, sockets etc.; shall be enumerated afterwards and measured separately. Rates include for all necessary extra joints, cutting and waste.(b) The rates include for supply of pipe nails, distance pieces, plugs, holder bats etc., and all jointing materials and also for all necessary cutting of pipes and jointing and fixing in positioninclude subsidiary materials, mentioned above and pipes, fittings and accessories and also waste arising from cutting of pipes. |
| 126 | M&L for preparation of old wood or wood based surfaces of any description, over 10 cm in width or girth and applying two coats of polyurethane paint over a coat of polyurethane direct primer incl removing old paints by paint removes or burning off by blow lamps and cleaning with scrapers, any number of coats,any width or girth complete all as specified and directed. |
| 127 | M&L preparation of old decorated wooden painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of polyurethane paint complete all as specified and as directed. |
| 128 | M&L for preparation of old steel surfaces of any description, over 10 cm in width or girth and applying two coats of polyurethane paint over a coat of polyurethane direct primer incl removing old paints by paint removes or burning off by blow lamps and cleaning with scrapers, any number of coats,any width or girth complete all as specified and directed. |
| 129 | M&L preparation of old decorated Steel painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of polyurethane paint complete all as specified and as directed. |
| 130 | The rates (from Sch Item- 124 to Item - 127) include for:(a) Use of all scaffoldings and cradles including hoisting and lowering.(b) Taking down, cleaning as directed and refixing blinds and fittings, picture rods, cornice poles and small items of builder’s hardware such as door knobs, finger plates, escutcheons, hooks etc. which are not required to be painted.(c) Use of dust sheets and other coverings for the protection of fixtures, fittings, furniture, etc.(d) Shifting of movable cupboards and furniture as required and replacing in position.(e) Work in patches (over one square metre each) including matching with existing work and marrying in at the edges.(f) Removing all splashes, drops, dirt, etc. and leaving premises in a clean state. |
| 131 | M & L for reparing of RCC projection, chajjas, roofs, facia, column etc by necessary preparation i.e scrapping ,cutting, chiseling, derusting and cleaning exposed reinforecement, surfaces of damaged, loose RCC surfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1: 1-1/2: 3) using 12.5 mm graded crushed stone aggregate and reinforeced with welded mesh of weight exc 2Kg per sqm but n.exc 3Kg/sqm with or without facia and finished including necessary scaffolding, shuttering, necessary chases to brick work or RCC members at any height upto 3 storey bldgs complete all as specified & directed (Note : Steel welded mesh is to be tightend / welded with the existing re-inforcement. The cost of welded mesh is deemed to be included in the unit rate quoted by the contractor). |
| 132 | M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed. |
| 133 | M&L Water proofing treatment on \"Non approachable / non accessible and approachable roof\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment,properly cleaning & drying the concrete surfaces complete (i) Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm(ii) Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm incl cleaning surfaces complete all as specified and directed. (iii) Laying evenly over the bitumen coated surface, polymeric water proofing membrane Hyperplas standardwith 100 mm over laps shall be sealed by flame as per manufacturers instruction complete all as specified and directed. (APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application (iv) Applying two coats of bitiminous aluminium paint @ 200 gm/sqm (minimum) in two coats all as specified and as manufacturer instruction complete as per manufacturers instruction. Note : (i) The work of water proofing treatment shall be got executed through expert team of manufacturers of authorized applicator of manufacturer. |
| 134 | M & L PCC (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) mixed with integral waterproofing chemical @ 200 ml per 50 Kg per cement, as in padding on roof surface for correcting / making proper slope on roof, and finishing the surfaces fair and even without using extra cementincl demolition complete all as specified and directed. (Note:- Liquid WPC shall be measured and paid separately.) |
| 135 | M&L10 mm thick rendering on roof surfaces/ concrete surface in CM 1:4 with liquid water proofing compound @ 200 ml per 50 Kg cement complete all as specified and directed.(Note:- Liquid WPC shall be measured and paid separately.) |
| 136 | Supply only water proofing compound (liquid), ISI marked complete all as specified and directed. |
| 137 | S&F in repairs ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. |
| 138 | S&F in repairs ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed. |
| 139 | S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed |
| 140 | S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed |
| 141 | S & FRotational moulded polyethylenewater storage tank (cylindrical vertical with closed top) 500 litre capacity hoisted and fixed in position including dismantling of old u/s water tankand removing to storecomplete all as specified and directed |
| 142 | S & FRotational moulded polyethylenewater storage tank (cylindrical vertical with closed top) 1000 litre capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed |
| 143 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store of 15 mm bore of pipe complete all as specified and directed. |
| 144 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store of 20 mm bore of pipe complete all as specified and directed. |
| 145 | M&L Cutting chases in brick walls/ stone masonary walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 146 | Supplying and laying of CPVC pipes with outer dia 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 147 | Supplying and laying of CPVC pipes with outer dia 25 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 148 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed. |
| 149 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed. |
| 150 | S&F Brass Elbow for CPVC Pipes with outer dia 20 mm complete all as specified and directed. |
| 151 | S&F Brass Elbow for CPVC Pipes with outer dia 25 mm complete all as specified and directed. |
| 152 | S&F Brass Elbow Rd (3/4 X ½) for CPVC Pipes with outer dia 20 mm complete all as specified and directed. |
| 153 | S&F Brass Teefor CPVC Pipes with outer dia 20 mm complete all as specified and directed. |
| 154 | S&F Brass Teefor CPVC Pipes with outer dia 25 mm complete all as specified and directed. |
| 155 | S&F Male Brass Threaded Adaptor (MTA/ MBTA)for CPVC Pipes with outer dia 20 mm complete all as specified and directed. |
| 156 | S&F Male Brass Threaded Adaptor (MTA/ MBTA)for CPVC Pipes with outer dia 25 mm complete all as specified and directed. |
| 157 | S&F Female Brass Threaded Adaptor (FTA/ FBTA)for CPVC Pipes with outer dia 20 mm complete all as specified and directed. |
| 158 | S&F Female Brass Threaded Adaptor (FTA/ FBTA)for CPVC Pipes with outer dia 25 mm complete all as specified and directed. |
| 159 | S&F Tank Adaptorfor CPVC Pipes with outer dia 20 mm complete all as specified and directed. |
| 160 | S&F Tank Adaptorfor CPVC Pipes with outer dia 25 mm complete all as specified and directed. |
| 161 | S&F Union for CPVC Pipes with outer dia 20 mm complete all as specified and directed. |
| 162 | S&F Union for CPVC Pipes with outer dia 25 mm complete all as specified and directed. |
| 163 | S&F Ball Valves for CPVC Pipes with outer dia 25 mm complete all as specified and directed. |
| 164 | S&F in repair 15 mm bore chromium plated central hole Basin mixer single lever without popup waste system with 450 mm long braided hoses complete all as specified and directed |
| 165 | S&F in repair Chromium plated wall mixer 3-in-1 system telephonic, connecting legs and wall flangecomplete all as specified and directed. |
| 166 | S & F in repair Brass chromium plated Swan Neck Sink mixer with raised J shaped swinging spout (Wall mounted model) with connecting legs & Wall flangescomplete all as specified and directed. |
| 167 | S&F in repair Vitreous china WHB size 550x400 mm white flat back including PVC waste pipe but excluding taps, waste, chain & plug & porcelain stopper but including brackets with two coats of synthetic enamel painting over a coat of red oxide primer etc complete all as specified and directed. |
| 168 | S&F in repair Vitreous China wash basin, angle back (counter-type/ table top), size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets with two coats of synthetic enamel painting over a coat of red oxide primer etc complete all as specified and directed. |
| 169 | S&F Vitreous pedestal china for WHB as per suilable for WHB size 550x400 mm complete all as specified and directed. |
| 170 | S & F in repair Bottle trap chromium plated for WHB as per approved quality all as per specified and directed. |
| 171 | S&F LDPE pipe 50mm of pressure rating 6 kgf/sqcm fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 172 | M&L in repair Wash down water closet vitreous china white pedestal pattern with \"P\" or \"S\" trap including connecting to outgoing drain pipe & to flushing pipe excluding flushing cistern and flush pipe complete all as specified and directed. |
| 173 | M&L in repairs Vitreous china squatting pan , ‘Orissa’ Pattern, size 580 X 440 mm white, with integral foot rests etc. complete all as specified and directed. |
| 174 | S&F in repairs Plastic water closet seat cover, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. (Note : Colour should be in harmony with EWC.) |
| 175 | S&Fin repairs 10 Ltr capacity PVC valveless shyphonic action type low level flushing cistern white with inlet, ball valve, float valve and handle incl bracket and flush pipe of low level of 32mm dia fixed to wall complete all as specified and directed. |
| 176 | S & F in repair Internal fitting for low level flushing cistern (Syphon) complete all as specified and directed. |
| 177 | S&F in repairs Brass Butter Fly Jet Spray with 1.2 meter Long Flexible Tube of premium quality fitted to Vitreous china, wash down water closet pan (pedestal pattern) stop cock/ angle cock all complete all as specified and directed. |
| 178 | S & F in repairs Health faucet (ABS Body) mild steel pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 179 | S&Fin repair PVC connection 15mm dia size with PTMT nuts and 450 mm long complete all as specified and as directed. |
| 180 | S&F in repair Looking Mirror 5.5 mm thick of selected quality glass of size 600 x 450 mm bevelled edge, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screw and cup washers including aluminium anodized frame complete as specified and directed. |
| 181 | S&Fin repair Bib taps 15 mm bore, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed |
| 182 | S&Fin repair Two-way Bib taps 15 mm bore, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed |
| 183 | S&F in repair Brass chromium plated tubular towel rail 20 mm dia, D type, 60 cm long between flanges complete all as specified and directed. |
| 184 | S&F in repair Angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe complete all as specified and directed. |
| 185 | S&F in repair Two-way Angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe complete all as specified and directed. |
| 186 | S&F in repair, 15 mm bore stop cock, cast copper alloy with long shank and cup (concealed type) fancy type chromium plated screwed down high pressure with crutch & butterfly handle screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 187 | S&F in repair Stainless Steel Soap dish complete all as specified and directed by Engineer-In-Charge. |
| 188 | S & F in repair Toilet paper holder with flat recessed type stainless steel complete all as specified and directed. |
| 189 | S&F in repair Chromium plated overhead shower rose swivel type 125 mm with CP arms 300 mm long complete all as specified and directed. |
| 190 | S&F in repair Glass shelf assembly cosisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard and railing 60cm long complete all as specified and directed. |
| 191 | S&F in repair Sliding door PVC cabinet mirror of size 600 mm x 450 mm with internal shelves all as specified and directed. |
| 192 | Taking down bib tap/ wash basin tap/ pillar tap/ stop cock/ mixer tap and refixing the same after repair and replacement ofspindles for 15 mm bore size complete all as specified and directed. |
| 193 | S&F in repair Pillar tap cast copper alloy with capstan head chromium plated crewed down high pressure with or without lettered hot or cold with long screwed sharks and ply nuts 15 mm dia complete all as specified and directed. |
| 194 | S&F in repairPVC waste pipe for WHB etc all as specified and directed. |
| 195 | S&F in repairs 32 mm bore dia waste coupling of(min weight 32 mm-45 gm of PTMT) (half or full threaded) etc complete all as specified and directed |
| 196 | S&F in repair CP grating 100 mm dia with waste hole (minimum weight 40 gm) complete all as specified and directed |
| 197 | S & F in repair Kitchen sink made of stainless steel 1 mm thick with plug washer and waste pipe incl bedding fixing cantilever brackets and connetction union to pipe overall size 915 X 460mm bowl size 405X 355 X160 mm complete all as specified and directed |
| 198 | S& F in repair 1 mm thick stainless steel plate rack of size 900X900X250 incl fixing with rawal plug and screws complete all as specified and directed. |
| 199 | S&F in repairs Flush pipe 32 mm dia of polyethylene of low or high density or PVC, for low level cisterncomplete all as specified and directed. |
| 200 | S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe of 20 mmbore dia of pipe complete all as specified and directed. |
| 201 | S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends (ISI marked) for iron pipe of 25 mmbore dia of pipe complete all as specified and directed. |
| 202 | S & F in repair Corner glass shelf of size 300 mm with brackets complete all as specified and directed. |
| 203 | S & F in repairs Magic Eyes for door eye viewers brass body complete all as specified and directed. |
| 204 | S & F in repair chromium plated towel ring with bracket complete all as specified and directed. |
| 205 | S&F in repair Stainless steel fancy type curtain rod 25 mm dia as approved complete all as specified and directed |
| 206 | S&F in repair SS Globes for 25 mm dia curtain rod as approved by Engr-In-Charge complete all as specified and directed. |
| 207 | S&F in repair SS Curtain rodBracket fancy type for single curtain rod 25 mm dia of any colour as approved complete all as specified and directed. |
| 208 | M&L for Cleaning of septic tank/soak well of any capacity, and any depth in mud in foul poistion by de-sludging, disilting and getting out all silt, sludge, organic and inorganic materials by manuyally / mechanically and removing the sludge to a distance exc 250 mtr but not exc. 500 mtr away from site and burrying in to pits and covered with earth including spreading bleaching powder @ 1 kg per sqm complete all as directed at site, complete all as specified and as directed. |
| 209 | M&L for Cleaning of blockageof sewer lines of any dia in any position by roddingfrom both sides between two adjacent manholes or from inspection chamber to manhole or from gully trap to inspection chamber or through inspection eye of any depth till clear flow of sewer/water is observed complete all as specified and as directed at site by Engineer in charge.Note:- Unit rate quoted shall deemed to be included of cleaning of scurbs,grass small roots etc,around the manholes, inspection chamber at adjacent to the pipe lines cleaningetc and along sewage lines wherever required or as directed and no extra payment shall be made on this account).Note: The length of sewage line to be measured from manhole to manhole/chamber for payment purpose. |
| 210 | Attending day to day complaint for Cleaning of blockage floor/ nahani/ bottle trap of wash hand basin/ sink/ bathrooms/ kitchen and WC (any type) by using hand pump with rubber bucket or by cleaning rod till clear flow of water is observed all complete all as specified and as directed.Note:- The complaint slips to be collected from the complaint cell daily by the contractor or his authorised representative/ supervisor. The complaint to be attended and cleared within 24 Hrs or otherwise as given in particular specifications from the date and time of handing over of complaint slip and to be deposited to the concerned JE I/C or Engineer-in-Charge duly signed by the users. In case of delay in clearing the complaint, the penalty to be imposed to the contractor as indicated in particular specifications for every day of delay. |
| 211 | M&L for Cleaning of blocked / soaked manholes and removal of sludge, soil, & any materials found from manholes by manually or machinically any depth of manhole complete all asspecified and as directed. |
| 212 | M&L for laying of Double Wall Corrugated (DWC) SN8 HDPE of 150 mm internal diameter of drain pipes laid in trenchesand jointed using a push-fit or push-on joint with elastomeric sealing ring cement concrete bed to drain pipes including packing under and haunching againstthe sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate including excavating the trench, demolition and breaking up old drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortar for 150 mm internal dia of pipe and returning and filling the soil after completion of work, complete all as specified and directed. (Note : Jointing method as Rope method, jointing jack method, backhoe method or thermal coupling method may also be used as per the site requirement and the direction of Engineer-In-Charge). |
| 213 | M&L for laying of Double Wall Corrugated (DWC) SN8 HDPE of 200 mm internal diameter of drain pipes laid in trenchesand jointed using a push-fit or push-on joint with elastomeric sealing ring cement concrete bed to drain pipes including packing under and haunching againstthe sides of pipe after they are laid & tested for 200 mm bore of pipe withcement concrete 1:3:6 type C-2 using 40mm graded stone aggregate including excavating the trench, demolition and breaking up old drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortar for 200 mm internal dia of pipe and returning and filling the soil after completion of work complete all as specified and directed. (Note : Jointing method as Rope method, jointing jack method, backhoe method or thermal coupling method may also be used as per the site requirement and the direction of Engineer-In-Charge). |
| 214 | Dismantling of 300 mm or 450 mm internal dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 215 | M&L for laying of 300 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed. |
| 216 | M&L for laying of 450 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed. |
| 217 | M&L for cement concrete bed to drain pipes including packing under and haunching againstthe sides of pipe after they are laid & tested for 300 mm / 450 mm of pipe withcement concrete 1:3:6 type C-2 using 40mm graded stone aggregatecomplete all as specified and directed. |
| 218 | M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed. |
| 219 | M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 200 mm internal dia of pipe complete all as specified and directed. |
| 220 | M&L in repairs salt glazed stone ware gully traps size 150 x 150mm, square or round mouthed, type ‘P’ including setting and jointing to drains with CM 1:1 including demolition of existing traps complete all as specified and directed. (Note: CI grating will be meaured separately). |
| 221 | M & L Light shade/ Dark shade Endura vitrified tiles of size size n exc 0.36 Sqm8-12 mm thick following the specifications as per IS 15622-2006, cut to required size set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles as in floor incl screed bed or bedding layer of mortar 15 mm thickin CM 1:4for laying of floor tiles incl dismantling of floor tiles including bedding (but not backing), and rubbish off premises or removed to store complete all as specified and directed. |
| 222 | M&L for preparation of newly plastered surfaces of walls and apply three coat of white wash complete all as specified and directed. |
| 223 | S&F Polycarbonate Water-proof film coated/ transparent plain sheet 6 mm thick of any colour in roof covering/ cladding to wall, sunshed etc fixing/ joint/ overlap incl requisite material all as per manufacturers instructions complete all as specififed and directed. |
| 224 | M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 250 ltr n.exc 500 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and usingbleaching powder @ 0.25 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning,etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 225 | M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 500 ltr n.exc 1000 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using with bleaching powder @ 0.50 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning,etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 226 | M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 1000 ltr n.exc 2000 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using with bleaching powder @ 0.50 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning,etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 227 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 228 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 229 | Excavating in post holes (or similar holes) each n.exc 0.5 cum getting outmaking good the disturbed surface if required in soft/ loose soil complete all as specified and directed. |
| 230 | M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in foundation filling and mass concrete all as specified and directed. |
| 231 | S&F Angle iron posts and rails,drilled and struts in fencing including cutting tops to shape as directed, driiling holes, notching for wire, etc, flat iron fillets (for secruing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 232 | Mild Screw bolts (Machine made) with hexagonal or square head at one ends andto fitted with washers and one hexagonal or square n.exc 15cm long, dia of neck 11 to 15mm all as specified and directed. |
| 233 | S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, includingcranking, bending spirally for hooping for columns, hooking endsand binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified & directed. |
| 234 | Dismantling posts or sturts (wood,steel or RCC) any section incl taking out embedded portion and making good disturbed ground etc all as specified and directed. |
| 235 | Dismantling fencing wire mesh any type etc all as specified and directed. |
| 236 | Disconnecting existing tanks capacity exc 250 Litre but n exc 500 Litre, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 237 | Disconnecting existing tanks capacity exc 500 Litre but n exc 1000 Litre, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 238 | S & F of precast SFRC Manhole cover including frame of circular or rectangular shape (required as per site condition), load capacity HD - 20 and M-30 or higher grade of concrete confirming to IS 12592:2002 as in cover slab of manholes, septic tank, soak well etc set in cement mortar 1:4 with plain fair faces complete all as specified and as directed. Note : (i) Contractor shall provide PV alongwith manufacturer test certificate of SFRC cover. (ii) Reinforcement shall not be measured and paid seperately |
| 239 | S&F in repair Single door PVC cabinet mirror of size 350 mm x 450 mm with internal shelves all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail