| Sl. No. | Item Description |
| 1 | Providing supply and installation of Tennis Net Post with net with foundation all complete as per standards. |
| 2 | Providing and applying Acrylic Synthetic sports flooring eight layers,1st layer of applying Acrylic Resurfacer mixed with approved grade of Silca sand and cement and water and applied with rubber squeege @0.024 persq.ft as per Standards.2nd layer of applying SBR granules (Coarse and fine) mixed with Rebound liquid rubber resin and water @.024 ltrs per sq.ft. as per as per Standards.3rd layer of applying SBR granules (fine) mixed with Rebound liquid rubber resin and water @.020 ltrs per sq.ft. as per as per Standards.4th and 5th layer of applying SBR granules (fine) mixed with Rebound liquid rubber resin and water @0.021 ltrs per sq.ft. per layer as per as per Standards.6th layer of applying Acrylic filler layer mixed with approved grade of silca sand and water @ 0.022 ltrs per sq.ft as per manufacturer`s specification. Color added @0.005 in Filler to make in color for easy application.Sanding of the entire area with rubbing stone to make the surface smooth for color coat application.7th and 8th layer of UV Resistant Rebound Acrylic color of approved shade mixed with water @ 0.024 ltrs per sq.ft as per as per Standards.Application of UV protected White Rebound line marking as per international standards |
| 3 | Providing and Fixing TOILET CUBICLE - Toilet Cubicle Made Of Heat, Bacteria, Water Chemical, Scratch, Impact and Anti Bacterial Resistant 12Mm Thick ,Solid Compact Laminate Panels Included Doors, Pilasters and Intermediate Panels.Toilet cubicle I Shape (Front Partition) with standard ,dimension of Upto1950mm height x 1200mm width x 1500mm ,depth which includes 550-600mm door size width.Doors 1,Vertical Pilaster 2,U / Door Channels and Top Rail :- SS 304 Grade as per plan,Foot Assembly :- Shoe Box SS 316 Grade 16,Door lock with indicator SS 304 Grade 8,Door Knob SS 304 Grade 8,Self Closing Gravity Hinges SS 304 Grade 24,Coat Hook SS 304 Grade 8,Screws SS 304 Grade as per plan.all work done as per directed by engineer in charge. |
| 4 | Main LT Panel: Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor.400A FP MCCB, 415 V, 50 Hz. : 2 Nos400A 4P Contractor 415 V, 50Hz.: 2 Nos With Electro Mechanical Interlocking arrangmentIndication and digital metering 400TP plus N Aluminium sectionalised BUS suitable for 1.1 K V with a fault level with-stand: 20 KA for 1 second. The Earth Bus shall be of AL and run contInuously throughout the width of the panel.Outgoing :125A, 4Pole, 50 Hz, MCB : 1 Nos. 63 A, 4Pole, 50 Hz, MCB : 6 Nos. 40 A, 4Pole, 50 Hz, MCB : 4 Nos. 20 A, DPPole, 50 Hz, MCB : 3 No. Indication lamps (RYB) with control MCB - 03 Sets Danger notice plate Make : As listed in UHBVNL |
| 5 | Main LT Panel : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor.125A FP MCCB, 415 V, 50 Hz. : 2 Nos125A 4P Contractor 415 V, 50Hz.: 2 Nos With Electro Mechanical Interlocking arrangmentIndication and digital metering 125TP plus N Aluminium sectionalised BUS suitable for 1.1 K V with a fault level with-stand: 20 KA for 1 second. The Earth Bus shall be of AL and run contInuously throughout the width of the panel.Outgoing :63 A, 4Pole, 50 Hz, MCB : 3 Nos. 40 A, 4Pole, 50 Hz, MCB : 2 Nos. 20 A, DPPole, 50 Hz, MCB : 3 No. Indication lamps (RYB) with control MCB - 03 Sets Danger notice plateMake : As listed in UHBVNL |
| 6 | Pathway Lighting Panel : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor.Incomer :40A TPN MCCB - 1 NOS :Outgoing : 16A TPN MCCB - 3 NOS : Indication lamps (RYB) with control MCB - 03 Sets with Timer and ContactorDanger notice plateMake : As listed in UHBVNL |
| 7 | Providing, Fabricating, Assembling, Painting, Hoisting and Erecting in position including detailing of Primary Steel Structure M.S RHS/SHS/CHS/Plates of thicknesses as per static analysis conforming to IS 4923 / 1161/ 2062 Grade 250MPA in profile. Fabrication of structural elements shall be done using ARC/SAW/MAW/ welding process, including transportation, cutting, threading, machining, all leads and lifts up to all heights, tools and plants and necessary scaffolding etc. required for all operations.The structural members shall be painted with first coat of Epoxy Primer DFT 30-micron, Final Coat Epoxy Paint 80 microns thick (to be applied in two coats) of which first coat shall be at ground and second coat after erection including touch- up of damaged area of already painted surfaces if any, up to all heights including Designing, Detailing, Providing, Fixing including Fabrication, Assembling and Erection of Roofing Material as per Non-Linear Analysis Maintaining a min Safety Coefficient of 4. Roofing Material Should be PES PVC Coated Fabric with both side PVDF lacquered/Coated, Weight 950 GSM, minimum Tensile Strength 5600/5400 N/5cm, minimum Tear Resistance 1000/900 N, minimum 10/15 years warranty FR Retardant B1.This work shall include raw material, patterning, forming, cutting, Seaming (Welding), fixing and installation with GI cables thickness as per Analysis, flashing, SS Swage End Grade 304, Galvanized Membrane Plate with Paint as per Spec. etc. complete as per direction of the Engineer-in-Charge.Clamping and Fixing Plate should be Galvanizedthickness as per design requirement. Seam Width should be Single Stroke and Minimum 50mm wide. Standard Warranty on Roofing Material should be minimum 10/15 Yrs. from Roofing Material Manufacturer/Supplier.Note:1. Mode of Measurement: Surface Area of ConsumedTensile FabricStructure proposed by the contractor shall be vetted byKSCL through NIT/IIT etc. and vendor shall have to work accordingly.Fabric Make: Ferrari/ Mehler/ Verseidag/ Haytex/ Hiraoka/ Sieon/ SattlerFabric Colour: White or as approved by KSCL |
| 8 | Providing, Fabricating, Assembling, Painting, Hoisting and Erecting in position, including detailing of Primary Steel Structure M.S RHS/SHS/CHS/Plates of thicknesses as per static analysis conforming to IS 4923 / 1161/ 2062 Grade 250MPA in profile. Fabrication of structural elements shall be done using ARC/SAW/MAW/ welding process, including transportation, cutting, threading, machining, all leads and lifts up to all heights, tools and plants and necessary scaffolding etc. required for all operations.The structural members shall be painted with first coat of Epoxy Primer DFT 30-micron, Final Coat Epoxy Paint 80 microns thick (to be applied in two coats) of which first coat shall be at ground and second coat after erection including touch- up of damaged area of already painted surfaces if any, up to all heights including Designing, Detailing, Providing, Fixing including Fabrication, Assembling and Erection of Roofing Material as per Non-Linear Analysis Maintaining a min Safety Coefficient of 4. Roofing Material Should be PES PVC Coated Fabric with both side PVDF lacquered/Coated, Weight 950 GSM, minimum Tensile Strength 5600/5400 N/5cm, minimum Tear Resistance 1000/900 N, minimum 10/15 years warranty FR Retardant B1.This work shall include raw material, patterning, forming, cutting, Seaming (Welding), fixing and installation with GI cables thickness as per Analysis, flashing, SS Swage End Grade 304, Galvanized Membrane Plate with Paint as per Spec. etc. complete as per direction of the Engineer-in-Charge.Clamping and Fixing Plate should be Galvanizedthickness as per design requirement. Seam Width should be Single Stroke and Minimum 50mm wide. Standard Warranty on Roofing Material should be minimum 10/15 Yrs. from Roofing Material Manufacturer/Supplier.Note:1. Mode of Measurement: Surface Area of ConsumedTensile FabricStructure proposed by the contractor shall be vetted byKSCL through NIT/IIT etc. and vendor shall have to work accordingly.Fabric Make: Ferrari/ Mehler/ Verseidag/ Haytex/ Hiraoka/ Sieon/ SattlerFabric Colour: White or as approved by KSCL |
| 9 | SITC of 40W LED Batten having Extruded aluminium housing fitted with Engg. Plastic end caps. With Opal diffuser.LED should be populated on FR4 PCB in which LED’s should be mounted and connection should be in series parallel.LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level))=110lumens/watt, Minimum system Lumens 4400 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500K ±500K, CRI)=80, PF)=0.9,THD(10%, and Operating Temperature Range-10 deg C to plus 50deg C, IP20. Built in Surge Protection of 4KV and an operating Voltage Range of 140 to 300V AC,50Hz.The driver should be constant current driver.The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance. Bajaj Cat. Ref.BCLAB SP 44L LED CW PC SD or Equivalent. |
| 10 | SITC of recessed mounted LED 600x600mm fitting made of CRCA) sheet steel housing comprising of LED’s connected in series parallel,Opal diffuser fixed in separate white powder coated ,Opal diffuser frame is held in with housing by screws for easy maintenance. Fixture should have minimum efficacy at System level (Not Chip Level) )=100lumens/watt, ,Minimum system Lumens 3600 lm ±10%Life of fixture 50000hrs@L70 Lumen maintenance, CCT up to 5700K±300K, CRI minimum 80, PF =0.95, THD (10% and an operating Voltage Range of 140 to 277V AC. Minimum Internal Surge Protection 2.5 kV. The fixture should comply with the other parameters as per IS10322 and specifications. Bajaj Cat. Ref BZRSLL 36W LED WH i |
| 11 | Supply of LED recessed Downlighter with a nominal system lumen output of 1200 lumens ±10% and a minimum system efficacy of 100 lm/W. The luminaire should have a color temperature of 5700K and CRI)80. The luminaire shall meet IP20 rating with THD(10% and PF ) 0.95. Built-in Surge protection of 2 kV,Maintenance of lumen output 50000 hrs.The luminaire housing should made of pressure die cast aluminium with a high efficiency diffuser.Bajaj Cat. Ref BZSLOS nxt 12L LED WH SD |
| 12 | Supply of 40W LED industrial Weatherproof Batten having Extruded aluminium housing fitted with end caps. Luminaire should be Completely prewired with accessories up to terminal block and fixture should have minimum efficacy at System level (Not Chip Level))=120lumens/watt, Minimum system Lumens 4800 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500K ±500K, CRI)=80, PF)=0.9,THD(10%, and Operating Temperature Range-10 deg C to plus 50deg C, IP65,IK07. Built in Surge Protection of 4KV and an operating Voltage Range of 140 to 300V AC,50Hz.The driver should be constant current driver. The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance. Bajaj Cat. Ref.BIPC 40W XE TYPE or Equivalent. |
| 13 | Tennis court Lighting : Supply and Installation of 320W LED flood light Olymipc type luminaire, LED luminaire having Epoxy powder coated pressure die-cast aluminium housing,Weatherproof gaskets should be provided for LEDs and control gear compartments.Luinaire should be suitable for Side entry mounting for max. 38mm OD pipe bracket.The LED driver acces should be from top for easy maintenance.LEDs should be provided with non-yellowing modular secondary lens optics.LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level))=120lumens/watt, Minimum system Lumens 38400 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 5665K ±355K, CRI)=70, PF)=0.9, THD(10%, and Operating Temperature Range-5 deg C to plus 45deg C, IP66. Built in Surge Protection of 4KV and external surge protection of 10kVand an operating Voltage Range of 140 to 270V AC,50Hz.Luminaire Weight should not exceed 1.5kg.The driver used is specially designed to have built-in surge voltage, open/short circuit protections.The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance.LUMINAIRE MAKE : Phillips / Bajaj / Surya /VAK Lighting.LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM. |
| 14 | Supply, erection testing and commissoning of 8 person (540-560kg) electrically operated lift serving of 3 step call opening is same side, lift car and entrance shall be of stainless steel finish, automatic rescure device at a speed of 0.75 / 1.00 mps including all necessary equipment and power operated centre / side opening sliding door stainless - No.3 finish, Microprocessor based simplex selective collective control with I without attendent.(the floor identify buttons shall be tactile or braille control rovisions) |
| 15 | Supply 7 installation of GEYSER 9L .Make Bajaj,havells,Crompton and grieavs,V-guard. |
| 16 | Providing 6Kg Fire Extinguisher Mono Ammonium Phoshate Powder 50, Stored Pressure Type, Pressure Gauge, Gross weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism, Range minimum 4 meters, applicable on Class A,B,C and electrically started Fire, A Rating 21A, B Rating 898, Can construction: Deep drawn and Co., Mig welded, valve construction : Forging and Machining, Internal Coating of Can : Epoxy powder coating, External Coating of Can : Epoxy Polyster power coating, sheet metal thickness: 1.60MM, Helium Leak Detection Tested, lSI and EN Approved, 5 years |
| 17 | Providing and Placing Dining teble with chair set,Dimension:-table:l-59,w-35.5,h-29.5, chair:l- 16.5,w-16.5,h-38,Stone and Marble on table top white no of chair 6 nos with table.chair feature Embossing and Engraving |
| 18 | Providing and PlacingWOODEN ALMIRAH Providing and PlacingChair-Pedestal BaseGlass Fibre Nylon with ABS/ NylonTwin Caster Wheels Minimum 5 Nos, of 50 mm SizeArm Material:pu foam bonded chrome cotedseat material:PU Foam covered with Fabric Material of Fabric Back Cover / Material for Backrestmesh fabricMaterial of Fabric of Seat Coverfoam liminated mesh fabricsChair Typeonly revolving without tilting mechanismHeight Adjustment ± 5(mm)up to 100 mmArmWithType of backrest supportbackrest symmetrical lumber supportArm TypeFixedErgonomic Seat DesignYesBack typefixedbackrest has separate adjustable headrestNoSeat typefixedNumber of arm movement N.ALumber supportintegratedOverall Chair Height ±15mm 1800, 900 X 600 mm Wooden Almirah made up of Decorative Block Board MR Grade Conforming to IS 1659 Material of ConstructionDecorative Block Board MR Grade Conforming to IS 1659Number of Shelves (Nos)4,Number of Doors (Nos)2,Height in mm (±10 mm)850,Depth in mm (±5 mm)430,Width in mm (±10 mm)700,Thickness of Top in mm (±2 mm)18,Thickness of Sides in mm (±1 mm)18,Thickness of Back in mm (±1 mm)12,Thickness of Bottom in mm (±1 mm)18,Thickness of shelf in mm (±1 mm)18,Thickness of Door in mm (± 1 mm)18,Type of Doors:Hinged doors of equal width hung with auto closing hinges of 0 cranking overlay type |
| 19 | Providing and PlacingWooden Single box Bed (1900x900x450) Material of Bed Frame Flat single layer 19mm ply board 12406/Latest Headrest provided Yes Legrest provided Yes Opening of Storage Box Opening From Top Number of Openings (Nos) 2 Hydraulic System provided for OpeningNoTop Panel have Supports from all the four sidesYES Leg DetailsTeak wood Number of Supports under Bottom Panel of storage box (Nos)4 Mattress Fixing Length ±10 (mm) 1830 Mattress Fixing Width ±10 (mm)1200 Mattress Panel Height ±5 (mm)40Depth of Storage Box in mm (±10 mm) 550 Thickness of Mattresses Panel ± 1(mm)19 Thickness of Bottom Panel of Storage Box ±1 (mm)19 Thickness of Front, Back and Side Panels ±2 (mm)18 Thickness of material of Headrest ±2 (mm 36 Overall Height of Headrest ±5 (mm)300Length of Headrest ±10 (mm) 1833 Thickness of material of Legrest ±2 (mm) 18 Overall Height of Legrest ±5(mm) 500 Overall Length of Legrest ±10 (mm) 1833 Size OF SUPPORT for Top Panel ±2 (mmxmm)50 x 25Size of Supports on under Bottom Panel of storage box ±2 (mmxmm)35 x35 |
| 20 | Providing and PlacingTable Executive Table of Teak wood 1200 millimeter 600 millimeter 800 millimeter Storage providedBoth sideKeyboard trayProvidedFoot restProvidedTable top MaterialTeak woodGable end and modesty panel materialCarved teak woodLeg MaterialNO LEGSThickness of table top ±2 mm25 millimeterLength of table top ±10 mm1200 millimeterDepth of table ±10 mm600 millimeterHeight of table ±10 mm800 millimeter Dimension of leg(mmXmm) ±5mmNo legsNumber of Storage unit providedDouble storageMaterial thickness of footrest ±2mm15mm |
| 21 | Supply Installation, Testing and Commissioning of 2 ton 3 star split AC with Copper Pipe, Steblizer,with outlet pipe terminated to neareast drain, all complete. Make Voltas,Lloyd,Carrier. |
| 22 | Providing and fixing of single lever divertor as per specifications complete in all respects |
| 23 | Providing and fixing AUTO CLOSING CONCEALED URINAL FLUSH VALVE -MAKE JAQUAR |
| 24 | Providing and Fixing in position DIVERTER CHR CP FACE PLATE |
| 25 | Providing and fixing C.P. brass shower with shower arm 15 or 20 mm inlet:150 mm diameter |
| 26 | Providing and fixing Health Faucet CP |
| 27 | Providing and fixing G.I. chain link fabric fencing of required width inmesh size 25x25 mm made of G.I. wire of dia 3 mm includingstrengthening with 2 mm dia wire or nuts, bolts and washers asrequired complete as per the direction of Engineer-in-charge. |
| 28 | [10.37.1]Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick [Through Rate] |
| 29 | [10.38]Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. [Through Rate] |
| 30 | [10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate] |
| 31 | [10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. [Through Rate] |
| 32 | [10.58]Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. [Through Rate] |
| 33 | [10.63.2]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm [Through Rate] |
| 34 | [10.67.2]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. Size of Tile 600x600 mm [Through Rate] |
| 35 | [10.77]Providing and laying 80mm thick factory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design and shape, laid in required colour and pattern over (BIS 15658:2006) and including 60mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. [Through Rate] |
| 36 | [11.17]Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge [Through Rate] |
| 37 | [11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate] |
| 38 | [11.54]Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. [Through Rate] |
| 39 | [11.58]Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete [Through Rate] |
| 40 | [11.9.1]15 mm cement plaster on rough side of single or half brick wall of mix: 1. 1:4 (1 cement: 4 coarse sand) [Through Rate] |
| 41 | [11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate] |
| 42 | [11.97.1]Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 1. Two or more coats applied on walls @ 1.25 litre/10 sqm over and including one coat of Special primer applied @ 0.75 litre /10 sqm [Through Rate] |
| 43 | [12.121]Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width and 32 mm thickness, frame will be mitred and Jointed with self driven self tapping screws of size 38 mm x 4 mm and PVC solvent cement, including fixing the frame to wall with suitable dia and length anchor fastener as per manufacturer`s specification and direction of Engineer-in-charge. [Through Rate] |
| 44 | [12.134.4]Providing and fixing factory made uPVC white colour sliding glazed window up to 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame and sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware`s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 4. Three track three panels sliding window with fly proof S.S wire mesh (Two Nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). [Through Rate] |
| 45 | [12.171]Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). [Through Rate] |
| 46 | [12.33.2]Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 2. With 12 mm mild steel U beading [Through Rate] |
| 47 | [12.36.2]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 2. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate] |
| 48 | [12.75.2]Providing and fixing bright /matt finished Stainless Steel handles of approved quality and make with necessary screws etc all complete. 2. 100mm [Through Rate] |
| 49 | [12.79.2]Providing and fixing bright finished brass door latch with necessary screws etc. complete : 2. 250x16x5 mm [Through Rate] |
| 50 | [12.86]Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. [Through Rate] |
| 51 | [12.89]Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. [Through Rate] |
| 52 | [12.98.2]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm [Through Rate] |
| 53 | [12.99.3]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm [Through Rate] |
| 54 | [13.24.1]Providing and fixing glazing in door, window, ventilator shutters and partitions etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of Gasket / beading shall be paid as per respective item) 1. Float glass panes of 5.5mm thickness [Through Rate] |
| 55 | [13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works [Through Rate] |
| 56 | [13.30.1]Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 1. Hot finished welded type tubes [Through Rate] |
| 57 | [13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate] |
| 58 | [17.25.1]Prime Coat @ 0.85kg per sqm 1. Prime Coat @ 0.60kg per sqm Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means as per technical clause 503 of MORT&H specifications [Through Rate] |
| 59 | [17.26.2]Tack Coat 2. Providing and applying tack coat with penetration grade bitumen VG - 10 using bitumen pressure distributor at the rate of 0.30 kg per sqm on the prepared bituminous/ granular surface cleaned with mechanical broom as per technical clause 503 of MORT&H specifications [Through Rate] |
| 60 | [20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\" (1200mm) [Through Rate] |
| 61 | [20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate] |
| 62 | [21.84.2]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 2. Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) [Through Rate] |
| 63 | [21.85.2]Extra for every 0.30 metre depth of Inspection chamber 2. 450 mmx 600 mm inside [Through Rate] |
| 64 | [21.96.1]Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade and PN- 4 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 1. 200 mm Outside Dia [Through Rate] |
| 65 | [21.96.5]Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade and PN- 4 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 5. 315 mm Outside Dia [Through Rate] |
| 66 | [22.10.1.1]Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1.1. Kitchen sink with drain board 510x1040 mm bowl depth 250 mm [Through Rate] |
| 67 | [22.101.2.1]Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore [Through Rate] |
| 68 | [22.103.3]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore [Through Rate] |
| 69 | [22.105.1]Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore [Through Rate] |
| 70 | [22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore [Through Rate] |
| 71 | [22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate] |
| 72 | [22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. [Through Rate] |
| 73 | [22.117]Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. [Through Rate] |
| 74 | [22.119.2]Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 2. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. [Through Rate] |
| 75 | [22.123.1.2]Providing and fixing PTMT grating of approved quality and colour. 1.2. Circular type 125 mm nominal dia with 25 mm waste hole [Through Rate] |
| 76 | [22.14.2.1]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 2.1. Flexible pipe 32 mm dia [Through Rate] |
| 77 | [22.15]Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. [Through Rate] |
| 78 | [22.164.1]Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 1. 100 mm diameter S.W. pipe [Through Rate] |
| 79 | [22.164.2]Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 2. 150 mm diameter S.W. pipe [Through Rate] |
| 80 | [22.166.1.2]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.2. 100x100 mm size P type With Sewer bricks conforming to IS : 4885 [Through Rate] |
| 81 | [22.191.1.1]Extra for depth for manholes : 1.1. Size 90x80 cm With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 82 | [22.195.1]Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : 1. With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 83 | [22.2.1]Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 1. White vitreous chinaware Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer [Through Rate] |
| 84 | [22.20.2]Providing and fixing in position C.I. plain Nahani Trap conforming to I.S.I. specifications and of self cleaning design with C.P. brass hinged grating with frame complete 2. With 75 mm internal diameter outlet [Through Rate] |
| 85 | [22.201.1.1]Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 1.1. L D- 2.5 Rectangular shape 600x450 mm internal dimensions [Through Rate] |
| 86 | [22.202]Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg [Through Rate] |
| 87 | [22.203.2]Providing sand cast iron drop connection externally for 60 cm drop from branch sewer line to main sewer manhole including inspection and cleaning eye with chain and lid, sand cast iron drop pipe and bend encased all-round with cement concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) with all centering and shuttering required, cutting holes in walls and making good with brick work in cement mortar 1:4 (1 cement : 4 coarse sand) plastered with cement mortar 1:3 (1 cement : 3 coarse sand) on inside of the manhole wall, lead caulked joints between sand cast iron pipes and fittings, stiff cement mortar 1:1 (1 cement : 1 fine sand) joints between sand cast iron tee and S.W. pipe, making required channels complete as per standard design and specifications : 2. 150 mm dia sand cast iron drop connection [Through Rate] |
| 88 | [22.210.4]Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 4. Rectangular shape 1500x450 mm [Through Rate] |
| 89 | [22.212.1.2]Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. 1.2. C.P Brass Two Way [Through Rate] |
| 90 | [22.216.1]Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-in-charge. 1. 25 Litres capacity [Through Rate] |
| 91 | [22.222.2.1]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 92 | [22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 93 | [22.222.2.4]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.4. Single Socket Type B 75mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 94 | [22.25.2]Providing and fixing white vitreous chinaware flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 2. One urinal basin with manually operated 5 litres PVC cistern and manually operated stop cock/ angle valve [Through Rate] |
| 95 | [22.34]Providing and fixing floor mounted, white vitreous chinaware single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous chinaware cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. [Through Rate] |
| 96 | [22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass [Through Rate] |
| 97 | [22.50.1.2.1]Providing and fixing partitions for different type of urinals. 1.2.1. Vitreous Chinaware Partition plate. Large size 835mm x 355 mm White [Through Rate] |
| 98 | [22.50.1.2.2]Providing and fixing partitions for different type of urinals. 1.2.2. Vitreous Chinaware Partition plate. Large size 835mm x 355 mm Single Colour [Through Rate] |
| 99 | [22.8.3]Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). 3. Three way [Through Rate] |
| 100 | [22.86.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes [Through Rate] |
| 101 | [22.87.1]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 1. 15 mm nominal outer dia Pipes [Through Rate] |
| 102 | [22.94.1]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 1. 15 mm nominal bore [Through Rate] |
| 103 | [22.94.7]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 7. 65 mm nominal bore [Through Rate] |
| 104 | [22.94.8]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 8. 80 mm nominal bore [Through Rate] |
| 105 | [22.98.1]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore [Through Rate] |
| 106 | [22.98.3]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. [Through Rate] |
| 107 | [22.98.4]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore [Through Rate] |
| 108 | [23.22.3.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.2. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. S.P.N. or DP enclosure suitable for DP MCB [Through Rate] |
| 109 | [23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) [Through Rate] |
| 110 | [23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) [Through Rate] |
| 111 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 112 | [23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate] |
| 113 | [23.22.5.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.5. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs TRIPLE POLE [Through Rate] |
| 114 | [23.23.10]MISCELLANEOUS 10. Supplying and drawing of 1 no UTP 4 pair CAT 6a LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] |
| 115 | [23.3.6.10]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.10. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 3 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate] |
| 116 | [23.4.1.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B [Through Rate] |
| 117 | [23.4.3.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.2. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group B [Through Rate] |
| 118 | [23.4.4.2]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.2. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B [Through Rate] |
| 119 | [23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate [Through Rate] |
| 120 | [23.8.11.3]FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch [Through Rate] |
| 121 | [23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket [Through Rate] |
| 122 | [23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket [Through Rate] |
| 123 | [23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate] |
| 124 | [23.8.2.2]FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick [Through Rate] |
| 125 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 126 | [24.1.12]EARTHING AND LIGHTENING ARRESTOR 12. Supplying and laying 6 S.W.G G.I. wire at 0.50 m below ground level from earth electrode including thimbles, soldering etc. as required. [Through Rate] |
| 127 | [24.1.6]EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. [Through Rate] |
| 128 | [24.11.30]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 30. 25 Sq mm 3.5 core (Arm.) [Through Rate] |
| 129 | [24.11.38]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 38. 35 Sq mm 3.5 core (Arm.) [Through Rate] |
| 130 | [24.11.46]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 46. 50 Sq mm 3.5core (Arm.) [Through Rate] |
| 131 | [24.11.62]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 62. 95 Sq mm 3.5 core (Arm.) [Through Rate] |
| 132 | [24.11.70]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 70. 120 Sq mm 3.5 core (Arm.) [Through Rate] |
| 133 | [24.11.76]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 76. 150 Sq mm 3.5 core (Arm.) [Through Rate] |
| 134 | [24.2.4.2]LT CABLE 4.2. Laying of underground cable in pipe /existing open/closed trench etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core [Through Rate] |
| 135 | [24.2.4.3]LT CABLE 4.3. Laying of underground cable in pipe /existing open/closed trench etc as required:- 50 Sq mm to 150 sqmm 2 to 4 Core [Through Rate] |
| 136 | [24.2.7.4]LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core [Through Rate] |
| 137 | [24.2.8.9]LT CABLE 8.9. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmm [Through Rate] |
| 138 | [24.4.8.7]STREET LIGHT 8.7. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 9 Metre Long pole with top dia 100 mm and bottom 200 mm with base plate of size 350 x 350 x 20 mm. [Through Rate] |
| 139 | [24.5.2.2]MISCELLANEOUS ITEMS 2.2. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 50/40 mm outer dia/ inner dia [Through Rate] |
| 140 | [25.3.6]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 6. 100mm dia. [Through Rate] |
| 141 | [27.41]Mastic Asphalt wearing coat ( 516 & 2702) Providing and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing antiskid surface with bitumen precoated fine grained hard stone chipping of 9.5 mm nominal size at the rate of 0.005cum per 10 sqm and at an approximate spacing of 10 cm centre to centre in both directions, pressed into surface when the temperature of surfaces not less than 100 deg. C, protruding 1 mm to 4 mm over mastic surface, all complete as per clause 516 of MoRTH Specification (5th Revision, 2013) [Through Rate] |
| 142 | [29.7]Design supply and installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider and bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets and Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener and anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion and seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter and in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof and dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, TandP, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. [Through Rate] |
| 143 | [4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate] |
| 144 | [4.16.1.3]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.3. All kind of soil Pipes, cables etc, exceeding 300 mm dia but not exceeding 600 mm dia. [Through Rate] |
| 145 | [4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate] |
| 146 | [6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 147 | [6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 148 | [6.13]Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth. [Through Rate] |
| 149 | [6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate] |
| 150 | [6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate] |
| 151 | [6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate] |
| 152 | [6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate] |
| 153 | [6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate] |
| 154 | [6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate] |
| 155 | [6.39.1]Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate] |
| 156 | [7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate] |
| 157 | [7.51]Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). [Through Rate] |
| 158 | [9.32.2]Providing and fixing UV stabilised fibreglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated `J` or `L` hooks, bolts and nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2. 2 mm thick flat [Through Rate] |
| 159 | [9.46.3]Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 3. 12.5 mm thick tapered edge gypsum moisture resistant board [Through Rate] |
| 160 | [9.58.1.1]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.1. Coupler 75 mm [Through Rate] |
| 161 | [9.58.1.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.2. Coupler 110 mm [Through Rate] |
| 162 | [9.58.1.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.3. Coupler 150 mm [Through Rate] |
| 163 | [9.58.4.1]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 4.1. Single tee without door 75x75x75 mm [Through Rate] |
| 164 | [9.58.4.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 4.2. Single tee without door 110x110x110 mm [Through Rate] |
| 165 | [9.58.4.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 4.3. Single tee without door 150x150x150 mm [Through Rate] |
| 166 | [9.58.5.1]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.1. Bend 87.5° 75 mm bend [Through Rate] |
| 167 | [9.58.5.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend [Through Rate] |
| 168 | [9.58.5.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5° 150 mm bend [Through Rate] |
| 169 | [9.59.2]Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 2. 110 mm [Through Rate] Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail