| 1 | Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of brick masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. |
| 2 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work. Mechanical Means Reference to MORT&H Specification 304 sr no 3.13 |
| 3 | Plain Cement Concrete M15 in Open Foundation complete as per Drawing and Technical Specifications. |
| 4 | RCC Grade M25 using batching plant transit mixer & Concrete pumpSame as Item 12.8 (E) upto 5m height, excluding formwork. For cost of formwork, add 4 per cent of cost of material, labour and machinery instead of 3.75 per cent . |
| 5 | RCC Grade M25 using batching plant transit mixer & Concrete pump Same as Item 12.8 (E) upto 5m height, excluding formwork. For cost of formwork, add 10 per cent of cost of material, labour and machinery instead of 3.75 per cent . |
| 6 | Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications. Reference to MORT&H Specification 1600 sr no 9.16 |
| 7 | Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. |
| 8 | Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification. Boulder Laid Dry Without Wire Crates. Reference to MORT&H Specification 2503 Sr No 15.1 |
| 9 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications |
| 10 | Providing and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in Table 500-39, prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing antiskid surface with bitumen precoated fine grained hard stone chipping of 9.5 mm nominal size at the rate of 0.005cum per 10 sqm and at an approximate spacing of 10 cm center to center in both directions, pressed into surface when the temperature of surfaces not less than 100 deg. C, protruding 1 mm to 4 mm over mastic surface, all complete as per clause 516. |
| 11 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 12 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. |
| 13 | Construction of Embankment with Material obtained from Borrowpits Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2. Reference to MORT&H Specification 305 Sr No 3.16 |
| 14 | Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical MORT&H Specification 2504 Sr No 16.05 |
| 15 | Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical Reference to MORT&H Specification 2504 Sr No16.04 |
| 16 | SUPPLY OF 1200mm Pipe RCC HUME PIPE NP-3 (SOCKETHUMEPIPE) |
| 17 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads up to 1 .00 km, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 |
| 18 | Brick soling with straight overburnt bricks laid on edge including preparation of subgrade to required camber and including supply of bricks, filling joints with local earth spreading a blind coat of 1cm(3/8\") depth of local earth P.I. 5 to 7 or sand over the entire surface and including labours, T&P etc. required for proper completion of work. |
| 19 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per technical specification clause 303.1 |
| 20 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 40 |
| 21 | Providing, laying, spreading and compacting stone aggregates of specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregates, watering and compacting to the required density grading 2 as per Technical Clause 405(4.8.3) |
| 22 | Providing, laying, spreading and compacting stone aggregates of specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregates, watering and compacting to the required density grading 3 as per Technical Clause 405(4.8.3) |
| 23 | Brick edging on both side of the road of M-150 bricks 8cm. (3\") wide and 12cm (4½\") deep laid with mud mortar including all labour and supply of brick finished to required template & ramming the excavated earth as directed by the Engineer-In-Charge. |
| 24 | Providing and applying primer coat with SS2 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 to 1.00 kg/sqm using mechanical means |
| 25 | Providing and applying Tack coat with bitumen VG-10 using Bitumen distributor at the rate of 0.30 kg per sqm on Primed/Granular surface cleaned with Hydraulic broom as per Technical Specification Clause 503 |
| 26 | Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm & 11.2 mm (Proportion 2:1) aggregates using VG-10 bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a HMP, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades. Technical Specification Clause 511. (MORTH) |
| 27 | Providing and laying of premix sand seal coat with HmP of appropirate capacity not less than 75 tonne/hours using crushed stone chipping 6.7mm size and penetration bitumen of suitable grade.as per MoRT&H Specification Clause No.513(ii). |
| 28 | Road Delineator Delineator: Supply & Fixing of MS Delineator made of Mild steel with pure polyester powder coating with the minimum thickness of powder coating of not less than 40 micron for protection against corrosion. The surface should be concealed so that there should not be any exposed surface without powder coating. Alternatively, these metal guide poles can be concealed with thermoplastic body. The posts shall have lan ellipsoidal or circular design with the height of the pole shall be 800 to 900 mm above the ground with about 200 to 300 mm base which can be anchored onto the ground. Mild steel Guide Poles shall conform to Type XI sheeting specifications as per IRC:67 and ASTM D4956 which would ensure to obtain clear visibility of the road alignment during night time. The Retro reflective sheeting shall be tested for A certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International Government Laboratory/Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 & Proof of the same Report shall be uploaded which quoting tender. The rate shall include all materials, labour T&P. transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge. |
| 29 | Retro-reflectorised Traffic sign as per IRC-67-2012providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67-2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm×75 mm×6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm×45 cm×60 cm. 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67.2012. Legends, letters, numerals and borders etc should be as per MORTH specification No-801.3.7. Proof of the same in form of government report shall be uploaded while quoting tender90 cm equilateral triangle with deffinitation plate size (20cm×60cm) |
| 30 | Retro-reflectorised Traffic sign as per IRC-67-2012providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67-2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm×75 mm×6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm×45 cm×60 cm. 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67.2012. Legends, letters, numerals and borders etc should be as per MORTH specification No-801.3.7. Proof of the same in form of government report shall be uploaded while quoting tender60 cm Circular with diffinitation plate (20cm×60cm). |
| 31 | Retro-reflectorised Traffic sign as per IRC-67-2012providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67-2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm×75 mm×6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm×45 cm×60 cm. 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67.2012. Legends, letters, numerals and borders etc should be as per MORTH specification No-801.3.7. Proof of the same in form of government report shall be uploaded while quoting tender30×90 cm (Left/Right) Object Hazard Please Enable Macros to View BoQ information |