| 1 | Repair / Patch work / Encasingof Various Vessels & Ductsin SA Plant during ATA-2026 |
| 2 | Patchwork/Repair/ Encasing on Various Vessels and Ducts with MS Material.Collection and transportation of MS Plates [6mm / 8mm/10mm/12mm/16mm thk.] and required materials from CD-Stores.Necessary site arrangements including scaffolding shall be done.Cut and remove the damaged portion/weak areas of the duct/vessel as per instruction, fabricate new pieces from 6/8/10 mm MS plates, fit up new pieces after proper edge preparation by grinding and full welding the joints to meet the site requirement.Encase the weak portions of the ducts/vessels with additional MS plates of 6/8 thick and full welding as per instruction of engineer in charge. MS plate shall be formed and shaped to existing shape/profile and symmetry of the vessels/ducts. Patchwork/encasing will have to be carried out at all area and elevations as required.After work completion,dismantle the scaffolding, clear the site and transport the the scrap to the scrap yard. |
| 3 | Patchwork/Repair/ Encasing on Various Vessels and Ducts with SS Material.Collection and transportation of SS Plates [6mm / 8mm/10mm thk.] and required consumables from CD-Stores.Necessary site arrangements including scaffolding shall be done.Cut and remove the damaged portion/weak areas of the ducts/vessels as per instruction, fabricate new pieces from 6/8 mm SS plates, fit up new pieces after proper edge preparation by grinding and full welding the joints to meet the site requirement.Any weak portions of the ducts/vessels to be encased shall be done with additional SS plates of 6/8 mm thick and full welding as per instruction of engineer in charge. Patchwork/encasing will have to be carried out at all area and elevations.SS plates shall be rolled,formed and shaped to existing shape/profile and symmetry of the vessels/ductsAfter work completion,dismantle the scaffolding, clear the site and transport the the scrap to the scrap yard. |
| 4 | Supply/unloadingand Handingover of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured PVC outer sheathed cable of size 3.5 cores x 400 sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 5 | Supply/unloadingand Handingover of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured PVC outer sheathed cable of size 3.5 cores x 50 sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 6 | Supply/unloadingand Handingover of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured PVC outer sheathed cable of size 3 cores x 50 sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 7 | Supply/unloadingand Handingover of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured PVC outer sheathed cable of size 3 cores x 35 sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 8 | Supply/unloadingand Handingover of650/1100V, Aluminium unarmoured, earthing cable of size 1 core x 70sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 9 | Supply/unloadingand Handingover of650/1100V, Aluminium unarmoured, earthing cable of size 1 core x 35sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 10 | Supply/unloadingand Handingover of650/1100V, Copper conductor PVC insulated, armoured PVC outer sheathed cable of size 5 cores x 2.5 sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 11 | Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3.5 cores x 400 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required. |
| 12 | Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3.5 cores x 185 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required. |
| 13 | Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3.5cores x 50 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required. |
| 14 | Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3 cores x 50 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required. |
| 15 | Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3 cores x 35 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required. |
| 16 | Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 5 cores x 2.5 sq.mm., copper conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required. |
| 17 | Supply of heat srinkable cable jointing kit for armoured cable of size 3.5 cores x 300 sq.mm. |
| 18 | Supply of heat srinkable cable jointing kit for armoured cable of size 3 cores x 185 sq.mm. |
| 19 | Supply of heat srinkable cable jointing kit for armoured cable of size 3.5 cores x 120 sq.mm. |
| 20 | Supply of cable tags, aluminium or SS for cables (cable No. pre-fix will be given at the time of erection) |
| 21 | Supply and Installtion of UG LT Cable Route Marker as per engineer in charge instructions for cable identification |
| 22 | Laying of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, PVC outer sheathed cable of size 3.5 cores x 400 sq.mm. through the existing cable tray at Q10 substation 25 mts / excavated trench 85Mts and cable trayat phosphorc acid dic wall (35 Mts) as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays/racks/risers/walls/columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 23 | Laying of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured,PVC outer sheathed cable of size 3/3.5 x 50 sq.mm. through the existing and newly fabricatedcable trayat various locations in Q10 berth installations of FACT, as per the instruction of engineer-in-charge. The scope of workshallalsoinclude laying, dressing, fixing on cable trays /racks /risers /walls /columnsclamping,tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 24 | Laying of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured,PVC outer sheathed cable of size 3 x 35 sq.mm. through the newly fabricatedcable trayat phosphorc acid dic wall , as per the instruction of engineer-in-charge. The scope of workshallalsoinclude laying, dressing, fixing on cable trays /racks /risers /walls /columnsclamping,tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 25 | Laying of 1 core x 70sq.mm. (2 Run x 110 Meter) unarmoured, earthing cable through the existing cable tray at Q10 substation 25 mts / excavated trench 85Mts and cable trayat phosphorc acid dic wall (35 Meters) as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays/racks/risers/walls/columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 26 | Laying of1 core x 35sq.mm. unarmoured, earthing cable through the newly fabricatedcable trayat phosphorc acid dic wall , as per the instruction of engineer-in-charge. The scope of workshallalsoinclude laying, dressing, fixing on cable trays /racks /risers /walls /columnsclamping,tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 27 | Laying of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured,PVC outer sheathed cable of size 5 cores x 2.5 sqmm armoured coper cable (4 run x 35 Meter) through the newly fabricatedcable trayat phosphorc acid dic wall, as per the instruction of engineer-in-charge. The scope of workshallalsoinclude laying, dressing, fixing on cable trays /racks /risers /walls /columnsclamping,tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 28 | Rerouting and Laying of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured,PVC outer sheathed cable of size 3.5 x 185 sq.mm. through the excisting cable trayat phosphorc acid dic wall , as per the instruction of engineer-in-charge. The scope of workshallalsoinclude laying, dressing, fixing on cable trays /racks /risers /walls /columnsclamping,tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 29 | Glanding and Termination of cable of size 3.5 corex 400 sq.mm. at PAT MCC Incomer and substation out going with suitable lugs and crimping. |
| 30 | Glanding and Termination of cable of size 3.5 corex 185 sq.mm. at PAT MCC Outgoing with suitable lugs and crimping. |
| 31 | Glanding and Termination of cables of size 3.5 core x 50 sq.mm.at various locationsin Q10 berthinstallations of FACT with suitable lugs and crimping. |
| 32 | Glanding and Termination of cables of size 3 core x 50 sq.mm. at PAT to motor terminal (30 KW Motor, 2 Nos.) with suitable lugs and crimping. |
| 33 | Glanding and Termination of cables of size 3 core x 35 sq.mm. at PAT to motor terminal (15 KW Motor, 2 Nos.) with suitable lugs and crimping. |
| 34 | Termination of earthing cable of size 1 core x 70 sq.mm. at PAT MCC and substation with suitable lugs and crimping. |
| 35 | Termination of earthing cable of size 1 core x 35 sq.mm. at PAT MCC to motor terminals at acid P2O5 pump house with suitable lugs and crimping. |
| 36 | Glanding and Termination of cables of size 5 core x 2.5 sq.mm. at PAT MCC module to motor push button station with suitable lugs and crimping. |
| 37 | Jointing of armoured cable of size 3.5 cores x 300 sq.mm. using heat srinkable cable jointing kit |
| 38 | Jointing of armoured cable of size 3 cores x 185 sq.mm. using heat srinkable cable jointing kit |
| 39 | Jointing of armoured cable of size 3.5 cores x 120 sq.mm. using heat srinkable cable jointing kit |
| 40 | Excavation and back filling of cable trench for laying power/ earthing cables/ cable trench of not less than 300 mm width and 600 mm depth(0.6 meter depth from ground level) |
| 41 | Shifting of existing PAT MCC to temporary shed. The scope of work includes dismandling MCC and all incoming/outgoing cables and shifting to nearest temporary shed./reassembling/fixing the MCC and providing 1 number of incoming cable of size 3.5 cores x 400 sq.mm. and 5 numbers of out going power cables (2 no.s of 3 cores x 50 sq.mm.,2 no.s of 3 cores x 35 sq.mm.,1 no.s of 3.5 cores x 185 sq.mm.) and 4 numbers of control cables (5 cores x 2.5 sq.mm.) in newly fabricated cable tray/trench with suitable single compression gland. |