| 1 | STEEL WORK |
| 2 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete._Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 3 | FLOORING |
| 4 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete._Size of Tile 600x600 mm |
| 5 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete._Size of Tile 600x600 mm |
| 6 | FINISHING |
| 7 | Distemperingwith 1stqualityacrylicdistemper (ready mixed)havingVOCcontentlessthan50gram/litre,of approved manufacturer, of required shade and colour all complete: |
| 8 | New work (two or more coats) over and including water thinnableprimingcoat withcement primerhavingVOC content less than50 pram/litre |
| 9 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 10 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required said and colour complete to give and even said._Old work (one or more coats) |
| 11 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 12 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :_One or more coats on old work |
| 13 | REPAIRS TO BUILDING |
| 14 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:_Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 15 | Dismantling and Demolishing |
| 16 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead._For thickness of tiles 10 mm to 25 mm |
| 17 | N.S. |
| 18 | Removing of damagedportion ofgypsum board from existing false ceiling and provingand fixing of new gypsum boardto existing ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 19 | Add for revised GST @18% in place of 12% ie 6.33% on 153038 |