| 1 | Supply, Erection/ Construction, Installation, Testing, Commissioning and satisfactory trial runs of advance fully automatic (having Micro processer-based control unit with IOT/ intranet/internet web-access, remote monitoring capabilities 5KLD capacity Faecal Sludge Treatment Plant (FSTP) of any Suitable Open Technology being adopted anywhere in India for Primary, Secondary & Tertiary/ any other Treatment of Faecal effluent meeting the standards prescribed by the MoEF&CC, GoI./ CPCB/ANPCC, as amend to date with treatment/ reuse/ safe disposal of sludge. The work including all Civil, Plumbing, Mechanical, Electrical & Instrumentation works along with spares wherever required as approved by Engineer-In-Charge. Including 03years of Operation & Maintenance of FSTP including deputation of technical manpower for testing, operation & monitoring/ supervision of Plant. |
| 2 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 3 | Providingand applyingtack coat usinghotstraight runbitumenof grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : |
| 4 | On W.B.M. @ 0.75 Kg / sqm |
| 5 | On bituminous surface @ 0.50 Kg / sqm |
| 6 | 2 cm premix carpet surfacing with 1.8 cum and 0.90 cum of stone chippings of 13.2 mm size and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately). |
| 7 | With paving Asphalt grade VG - 30 with no solvent |
| 8 | Providing and laying Bitumen Penetration Macadam with hard stone aggregate of quality, size and grading as specified, with bitumen of suitable penetration grade, including required key aggregate as specified, spreading coarse aggregate with the help of self propelled/ tipper tail mounted aggregatespreaderandapplyingbitumenbyapressuredistributor and then spreading key aggregate with the help of aggregate spreader complete, including consolidation with road roller of minimum 8 to 10 tonne capacity to achieve specified values of compaction and surface accuracy: |
| 9 | For 50 mm compacted thickness using coarse aggregate of size 50-20 mm graded @ 0.60 cum per 10 sqm key aggregate of size 12.5 mm graded @ 0.15 cum per 10 sqm. With paving asphalt grade VG - 10 @ 50 kg/ 10 sqm. |
| 10 | Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. |
| 11 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. |
| 12 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer- in-Charge. |
| 13 | With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 |
| 14 | Providing,Laying, stacking, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. |
| 15 | Sub base with stone aggreagte 90 mm to 45 mm including stone screening13.20mm |
| 16 | Base coarse with stone aggreagte 63 mm to 45 mm including stone screening 13.20 nn (Type-A) |
| 17 | Base coarse with stone aggreagte 53 mm to 22.4 mm including stone screening 11.20 mm (Type-B) |
| 18 | ProvidingIEI, EEI & Gen Set. |
| 19 | Supplying, installing and commissioning of Silent type \" Diesel generating set of 10 KVA with water cooled Diesel Engine, Electric start with suitable capacity 12 V battery, fitted complete with all the required accesories along with AC Alternator 3 Phase, 415 Volts, 50 Hz, 0.8 pfself Excited, Self RegulatedDesigned with Acoustic Enclosure(sound proof) as per CPCB-IV+, emission norms approved DG Set similar to KIRLOSKAR GREEN Make,Model:3R550NA 4GI or Equivalent. |
| 20 | Supply,inastallation, testing and commissioning of standard fully automatic mains failure panel for 10 KVA capacity genset of suitable size with following technical specification. (a)Electricity board supply of loading/Unloading in off/manual/auto mode.(b)Selectable Auto/Manual Start/Stop of the generator. (c)Selectable Auto/Manual loading/unloading of the generator. (d)Interlocking loops with solid state logic circuit to avoid shorting of EB supply side and generator supply side. (e) Short circuit protection system for both EB side and generator side. (f) Over load protection system for generator (g)Single phase reversal prevention system. (h) Phase sequence sensing system. (i) Time sensing system for all operation (j)Monitoring digital system for voltage, amps, and frequency.(k)Short circuit protection for DC circuit. (l)Fully automatic battery charger with all protections. (m) Manual Change over for EB by pass. |
| 21 | Supplying of one number XLPE insulated PVC outer sheathed with galvanised round steel wire or steel srtip armoured aluminium conductor power cable of 1.1 KV grade of size 25 sq.mm x 3.5 core conforming to IS 7098 (Part-I) 1988 amended upto date. |
| 22 | Supplying and layingof DWC HDPE pipe of size 50/38, ISI marked along with all accessories like socket, bend, couplers etc . Conforming to IS 16205 (Part 24): 2018/IS, complete with fitting and cutting, jointing etc. on open surface asrequired. |
| 23 | 50 mm dia (OD-50 mm & ID-38 mm nominal) |
| 24 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1kV grade of following size in the existing HDPE/DWC pipe as required. |
| 25 | Upto 35 sq. mm |
| 26 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1kV grade of following size in the existingopen surface/duct as required. |
| 27 | Upto 35 sq. mm |
| 28 | Providing Earthing with safe earthing electrode of galvanization 80 to 100 microns length 2000 mm, 48mm diaand inner space to be filled with crystaline conuctive mixture including filling - up with electrodite (Back fill Compound) 50kg for safe earth electrode and provoding masonary enclosure with cover plate having locking attagement etc. as required. (Similar to ASHLOK make SEE brand safe earthing or equivalent) |
| 29 | Providing· and fixing 25 mm X 5 mm· G.l. strip in 40 mm dia G.l. pipe from earth electrode including connection with G.l. nut, bolt, spring, washer excavation and refilling etc. as required. |
| 30 | Supplying and layingof DWC pipe of size 40/32, ISI marked along with all accessories like socket, bend, couplers etc . Conforming to IS 16205 (Part 24): 2018/IS, complete with fitting and cutting, jointing etc.direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 31 | 40 mm dia (OD-50 mm & ID-32 mm nominal) |
| 32 | Supplying and layingof DWC HDPE pipe of size 40/32, ISI marked along with all accessories like socket, bend, couplers etc . Conforming to IS 16205 (Part 24): 2018/IS, complete with fitting and cutting, jointing etc. on open surface asrequired. |
| 33 | 40 mm dia (OD-40 mm & ID-32 mm nominal) |
| 34 | Supplying of one number XLPE insulated PVC outer sheathed with galvanised round steel wire or steel srtip armoured aluminium conductor power cable of 1.1 KV grade of size 6 sq.mm x 3 core conforming to IS 7098 (Part-I) 1988 amended upto date. |
| 35 | Fabricating and Supplying of metallic street light pole made out of an overall length of 6.5 meters long having a bottom section length of 5.00 meters with 65 mm dia \"B\" class ISI marked G.I Pipe.Top section having a length of 1.5 meters with40 mm dia \"B\" class ISI marked G.I Pipe suitably bended for installing 01 No Street Light having earth stud and necessary GI reducer/coupling fixed at the top & middle. Welding 300 mm x 300mm x 6mm thick MS base plateto the bottom including welding100 mm X 25mm X 5mm M.S Flat for fixing PVC junction Box with 6A MCB on the Pole, i/c one coat of metalic primer and 02 coat of silver paint.Providing necessary wiring between junction box and st light fitting by 2x 1.5 Sq mm FR-LSH PVC Insulated copper conductor cable etc. as required. |
| 36 | Erection of pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1 :3:6) layer on top with including excavation and refilling etc. as required. |
| 37 | Above 4.5 meter and upto 6.5 meter |
| 38 | Supplying and FixingLEDstreet light of 30W with IP66protection and impact resistance ofIK07 equivalent to LUKER Sleek series street light product code LSTE-30 or its equivalent. |
| 39 | Supplying and Fixing2 Way Metal Enclosure alog with doule pole 40A Isolator with necessary inter connections as required Make:indoasian Cat No : 810560I & 810130 orits equivalent. |
| 40 | Wiring for light point / Fan point / Exhaust Fan point / Call Bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface / recessed PVC conduit, with modular switch, modular plate, suitable size G.I. box andearthing the point with 1.5 sqmm.FRLS PVC insulated copper conducotor single core cable etc. as required . |
| 41 | Group-C |
| 42 | Wiring for Light/ power plug wiring with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 43 | Wiring for Circuit/ sub mainWiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required. |
| 44 | 2x1.5 sq.mm + 1x1.5 sq.mm. earth wire |
| 45 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 Amodular switch, connections etc. as required. |
| 46 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular switch, connections etc. as required. |
| 47 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 48 | Supplying and fixing following way, horizontal type Single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) |
| 49 | 6 -way , Double door. |
| 50 | Supplying and fixing 5 A to 32 A rating,240/415 V, 10 kA \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 51 | Single Pole |
| 52 | Supplying and fixing following rating , double pole , 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 53 | 40 A |
| 54 | Supply of 20W LED,6500K, 4 Feet, RetrofitTube lightsimilar to Philips, Model no. 20W865 T8 IND I 2100lmor its equivalent to IS specification. |
| 55 | Supplying and fixing 4 pole 100 A, 415V onload change over switch with ss enclosure equivalent to Havells Cat No- IHCNFE0100 or its equivalent. |