| 1 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises compete all as specified and as directed. |
| 2 | M&L for Non Skid ceramic coloured tiles 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in cement motar1:4complete all as specified and as directed. |
| 3 | M&L forGlazed ceramic coloured tiles in vertical surface including highlighter of size 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick rendering in cement motar 1:4 complete all as specified and as directed. |
| 4 | Dismantling/demolition of brickwork or stone boulder masonry built in cement mortar including all quoins, arches, pillars etc, complete all as specified and as directed. |
| 5 | M & L forbrick work with sub-class \"B\" bricks, straight or curved on plan exc 6.0 metre mean radius as wall built in cement & sand mortar 1:6, complete all as specified and as directed. |
| 6 | Taking down cement plaster on brick or stone walls, concrete surface etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed. |
| 7 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 finished even & fair complete all as specified and as directed. |
| 8 | M&L rendering 15mm thick on other than fair face of brick work or concrete surface in cement mortar 1:4finished even & smooth (without using extra cement) complete all as specified and as directed.Note :- Liquid WPC shall be measured & paid seprately under relevant item of this BOQ (if mixed with liquid water proofing compound as per manufacturers instructions). |
| 9 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 10 | M&L for rendering 5 mm thick in cement and sand mortar 1:3 on fair faces of concrete surfaces as in ceiling including finishing the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 11 | M&L for prepration of newly plastered surface of walls providing 1mm thick wall care putty and applying two coat of distemper oil emulsion including over and including a coat of alklai resitant primer complete all as specified and as directed. |
| 12 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and as directed. |
| 13 | M & L for preparation of surface and applying twocoats of 100% premium acrylic exterioremulsion paint having VOC less than 50 gm/litre & excellent protection against UV, Alkali & Fungal resistance, exterior paint of required shade (Company Depot tinted) and including 2 mm thick wall care putty and priming coatof exterior primer applied at 0.90 litre/10 Sqm over new surfaces upto tripple storey. Allow 6-8 hours to dry the surface of both coat of paint to achieve excellent application with 3years perfomance warranty from manufacturers and instruction complete using limited man power including scaffolding, trestles, ladders, cradles and necessary safety measures for upto triple storey buildings, complete all as specified and directed. |
| 14 | S&F Solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube completeall as specified and as directed. |
| 15 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and as directed. |
| 16 | S&F Pressed steel frame for doors of size 125 X 60mm frabicated out & 1.25mm thick sheet with one or more rebates including necessary fixing lungs, hinges, lock strike plate, etc, supplied and fixed complete all as specified and as directed. |
| 17 | M&L for cement concrete 1:3:6 type C1(using 20 mm graded stone aggregate) as in bed blocks for fixing hold fasts and fillling of frames etc. complete all as specified and as directed. |
| 18 | S&F 30 mm thick, factory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides completeall as specified and as directed. |
| 19 | S&F 35 mm thick factory made second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and as directed. |
| 20 | S&F 100 mm long but hinges, extruded aluminium alloy with galvinised mild steel hinge pin, anodised ,type B-21, complete all as specified & directed. |
| 21 | S&FAluminium handles, cast type, anodised of 150 mm size complete all as specified and as directed. |
| 22 | S&FAluminium handles, cast type, anodised of 125 mm size complete all as specified and as directed. |
| 23 | S&F aluminium anodized barrel tower bolts 200 mm length of bolt of extruded section and fixed complete all as specified and as directed. |
| 24 | S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts 250 mm long of extruded sections or cast aluminium alloyand fixed complete all as specified and as directed. |
| 25 | S&F aluminium anodised, barrel tower bolts of extruded section, 125 mm length of bolt and fixed with screws, complete all as specified and as directed. |
| 26 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) Area exc 1.5 Sqm but n exc 4.00 Sqm each complete all as specified and as directed. |
| 27 | Taking down chowkats or frames n. exc 1.5 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and as directed. |
| 28 | S & F in replacement factory made Steel ventilator, ISI marked, with top hung shutters includinghingesand steel peg stay complete including making good disturbed surfaces of walls, complete all as specified. Note: for srl item No 48 to 50 here-in-above :(a) Steel windows/ventilator shall be of sizes to suit the size of opening at site and as ordered/directed by GE. (b)Steel windows /ventilator shall be factory made and shall be procured from one of the manufacturers as per Appendix ‘B’.(c)Steel windows/ventilator shall be conforming to IS-1038 and all as specified in these tender documents and MES Schedule Part-I. (d). The lugs of the steel windows/ventilator shall be fixed in P.C.C. blocks made of PCC 1:3:6 type C-1 using 20mm graded stone aggregate. Size of PCC blocks shall be 23 cm x 10 cm x 15 cm. (e)Cost of providing all the above aspects including the cost of lugs & P.C.C. blocks shall be deemed to be included in unit rate quoted for above items. Cost of making good the jambs to match with the adjoining surfaces shall be deemed to be included in the rates quoted. |
| 29 | S & Fwindow guard bars, plain and fixed independently in steel window frames, conforming to Fe 290 Gde E-165, complete all as specified and as directed. |
| 30 | S&F 3.0 mm thick figured glass ordinary quality and glazing with oil putty n.exc 0.5 Sqm each pane, complete all as specified and as directed. |
| 31 | S&F Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples or rivets, complete all as specified and as directed. |
| 32 | Taking up or down steel tubing and connections, 15 mm bore fixed on walls, floors or ceiling etc including cleaning for re-fixing or removal to store complete all as specified and as directed |
| 33 | Taking up or down steel tubing and connections, 20 mm bore fixed on walls, floors or ceiling etc including cleaning for re-fixing or removal to store complete all as specified and as directed |
| 34 | S&FGI tubing medium grade galvanised with all fitting and fixedto walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified and as directed |
| 35 | S&FGI tubing medium grade galvanised with all fitting and fixedto walls & ceilings or laid in floors, bore of pipe 20 mmcomplete all as specified and as directed . |
| 36 | S&Fin repair Bib tap, long body, cast copper alloy, chromium plated, fancy typelong body with crutch or butterfly handle, screwed down, suitable for 15 mm nominal bore iron pipe screwed for iron or brass ferrule and fixed complete all as specified and as directed. |
| 37 | S&F in repair swan neck pillar tap suitable for counter top WHB, cast copper alloy, with capstan heads, chromium plated, fancy type screwed down high pressure, with long screwed shank and fly nuts, with or without lettered \"Hot\" or \"Cold\" suitable for 15 mm nominal bore iron pipe, screwed for iron pipe and fixed complete all as specified and as directed. |
| 38 | S&F in repair 15 mm bore stopvalves, cast copper alloy, fancy type chromium plated, screwed down high pressure with crutch or butter fly handle screwed bothends for iron pipe or for unions complete all as specified and directed. |
| 39 | S&F in repair 15 mm bore stopvalves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type), screwed down high pressure with crutch or butter fly handle screwed bothends for iron pipe or for unions complete all as specified and directed. |
| 40 | S&F in repair 15 mm bore two way stopvalves, cast copper alloy, fancy type chromium plated, screwed down high pressure with crutch or butter fly handle screwed bothends for iron pipe or for unions complete all as specified and directed. |
| 41 | S&F in repair vitreous china wash down water closet (Pedestal pattern) white including suitable \"P\" or \"S\" trap and excluding (flushing cistern and flush pipe), complete all as specified and directed. |
| 42 | S&F in repair vitreous china squatting pan,Órissa pattern size 580 x 440 mm white, with integral foot rest and CI \"P\" trapcomplete , all as specified and directed. |
| 43 | S&F in repair toilet paper holder with flat recessed type stainless steel,fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. |
| 44 | S&Fin plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device seat and cover for pedestal pan, complete all as specified and directed. |
| 45 | S&F in repair PVC valveless, syphonic action type, flushing cistern, low level, white, 10 lit capacity with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 46 | S&F in repair of Vitreous China Urinal, Half stall type of size (375x390x590), white (excluding flushing cistern, flush pipe includingwaste pipe complete all as specified and directed. |
| 47 | S&F in repair counter sunk Vitreous China wash hand basin, white, flat back, size 560x400x205mmincluding fixing in granite slab, brackets & waste pipe of PVC 32 mm boreof low or high density complete all as specified and directed. |
| 48 | S&F PVC connection 15 mm size with PTMT nuts of length 450 mm including complete all as specified and as directed. |
| 49 | S & F in repair of chromium plated shower rose 125 mm dia with 200 mm long CP arm with swivel joints, any size, including fixing to steel pipe or union complete all as specified & directed. |
| 50 | S&F in repair ofTubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and directed. |
| 51 | S&F inrepair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 52 | S & F in repair, 2000 ltrISI marked three layer, white colour, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) with thread type cover and fixed with screw hoisted and fixed in position & including20 mm brass ball valvecomplete all as specified and as directed. |
| 53 | M & L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 54 | S&Fwelded steel wire fabric ,weight n. exc 4.00 kg/sq. mfixed to steel members complete all as specified and as directed. |
| 55 | Demolition cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 56 | M&L forPCC 1:3:6 type C1 using 20 mm graded stone aggregate with smooth finish including necessary form work etc. for water tank platform complete all as specified and as directed. |
| 57 | Demolition & breaking up drain pipes(Salt glazed ware, AC or Reinforced concrete, PVC) set in CM Internal dia of pipe 100 mm/75 mm complete all as specified and as directed. |
| 58 | S&F Cast iron soil, waste and vent pipes in any length with or without ears fixed to wall, including stack clamps of FI 50x5 mm and 10 mm round bar embedded in wall,of 110 mm bore complete all as specified and as directed. |
| 59 | S&F Cast iron soil, waste and vent pipes in any length with or without ears fixed to wall, including stack clamps of FI 50x5 mm and 10 mm round bar embedded in wall, of 75 mm bore complete all as specified and as directed. |
| 60 | S&F Cast iron soil, waste and vent pipes in any length with or without ears fixed to wall, including stack clamps of FI 50x5 mm and 10 mm round bar embedded in wall,of 110 mm bore complete all as specified and as directed. |
| 61 | S&F Cast iron soil, waste and vent pipes in any length with or without ears fixed to wall, including 3.00 no stack clamps of FI 50x5 mm and 16 mm round iron stays embedded in wall at interval of each metre, of 75 mm bore complete all as specified and as directed. |
| 62 | S&F in repair Cast iron bend of 110 mm bore with access door of any radius complete all as specified and as directed. |
| 63 | S&F in repair Cast iron bend of 75mm bore with access door of any radius complete all as specified and as directed. |
| 64 | S&F in repair Cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches of 110 mm bore complete all as specified and as directed. |
| 65 | S&F inrepair Cast iron nahanitrap of 110 mm bore, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 66 | M&L in repair for 20 mm thick Graniteblack work (in one single piece table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 67 | Dismantling/removing existing roof treatment any thickness and specification consisting ofscreed, tar felts etc, and removing the dismantled materials outside MoD land complete all as specified and as directed. |
| 68 | M&L for bitumen felt water proofing treatment using APP based polymeric membrane not less than 3 mm thick, weighing not less then 3.00 kg / Sqm, reinforeced with polyster non-woven fabric (weighing not less than 150 gm/sqm) laid over and including cold bitumen primer appliedat the rate of 0.30 kg/sqm by forced application complete all as specified and as directed. |
| 69 | M&L for providing cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) as in roof padding to achieve the required slope and smooth surface and in coping, benching etc mixed with liquid water as per manufactures instructions complete all as specified and as directed. |