| 1 | FIRST YEAR (1 to 12 Months) |
| 2 | 5.5 Tr capacity of air cooled ductable split Air conditioner comprising of hernetically sealed compressor. The condenser is of air cooled type equipped with necessary filters sections with necessary safety controls. The evaporator unit consisting of Dx type cooling coil, blower, 10 micron filters and all are housed in sheet steel casing. The power supply for all the equipments has been connected through control panel having MCB, Contactors, Scaners, control switches, PCBs, etc as per the standard design by the manufacturer of the AC plant with necessary protections .The unit incorporates with fire dampner,electronic controls and wired remote control.The conditioned air has been distributed through GSS ducting with volume controldiffusers. The return air has been collected from the ceiling. The installation is provided with false ceiling using gypsum / armstrongboard. Note: This plant is connected with 2 nos of condensing unit in one evaporator unit. Hence this plant has been considered has 2nos.Make of the AC Plant : Bluestar, Model-DSA1322R3AF (I/U) / DSA661R3AF (O/U). Year of installation: 2023Location: Conference Hall of ACD Main building. |
| 3 | 7.5 Tr capacity (22500 Kcal / hour ) ceiling mounted type ductable split Air conditioner comprising of 3 nos of 2.5Tr reciprocating hermetically sealed compressors. The evaporator unitconsisting of evaporator coil, blower, 10 micron filters and all are housed in sheet steel casing.The power supply for all the equipments has been connected through control panel having MCB, Contactors, control switches, PCBs, etc as per the standard design by the manufacturer with necessary electronic type controls and wired remote controller. The conditioned air has been distributed through GSS ducting with volume controldiffusers. The return air has been collected from the ceiling. The installation is provided with false ceiling using gypsum / armstrongboard. Make : Carrier, Bluestar, LG etc as stated below: |
| 4 | Make : Carrier, Model - 38LH - 090 TYear of installation: 1998.Location: CVD / PVD Lab |
| 5 | Make : Carrier, Model - 38LH - 090 TYear of installation: 1999Location: Flosolver. |
| 6 | Make: Bluestar, Model : DS - 903-0.Year of installation: 2003.Location:Director\"s Conference Hall. |
| 7 | Make: Carrier, Model : 38LH - 090 TYear of installation: 2006.Location:Director\"s Conference Hall. |
| 8 | Make : Carrier, Model - 38LH - 090 TYear of installation: 2003.Location: ALD Calibration standards Lab. |
| 9 | 8.5 Tr capacity (25500 Kcal /hour) ceiling mounted type ductable split Air conditioner comprising of 2 nos of 4.25Tr Scroll sealed compressors. The evaporator unit consisting of evaporator coil, blower, 10 micron filters and all are housed in sheet steel casing. The power supply for all the equipments has been connected through control panel having MCB, Contactors, control switches, PCBs, etc as per the standard design by the manufacturer of the AC plant with necessary electronic type controls and wired remote controller. The conditioned air has been distributed through GSS ducting with volume controldiffusers. The return air has been collected from the ceiling. The installation is provided with false ceiling using Armstrong board.Make : Carrier, Bluestar, LG etc,. as stated below: |
| 10 | Make: LG Electronics, Model -LB-40850 QCIYear of installation: 2004.Location: ACD Phase -II Conference hall. |
| 11 | Make: LG Electronics, Model -LB-40850 QCIYear of installation: 2005.Location: FMCD SARAS simulator Lab. |
| 12 | 8.5 Tr capacity of air cooled ductable split Air conditioner comprising of 2 nos of 4.25 Trhernetically sealed compressors of hernetically sealed compressor. The condenser is of air cooled type equipped with necessary filters sections with necessary safety controls. The evaporator unit consisting of Dx type cooling coil, blower, 10 micron filters and all are housed in sheet steel casing. The power supply for all the equipments has been connected through control panel having MCB, Contactors, Scaners, control switches, PCBs, etc as per the standard design by the manufacturer of the AC plant with necessary protections .The unit incorporates with fire dampner,electronic controls and wired remote control.The conditioned air has been distributed through GSS ducting with volume controldiffusers. The return air has been collected from the ceiling. The installation is provided with false ceiling using gypsum / armstrongboard.Make: Carrier.Year of installation:2012.Location: Guest House Dinning Hall & Lounge. |
| 13 | 8.5 Tr capacity of air cooled ductable split Air conditioner comprising 2 nos of condensor unit having 4 nos of 4.25 Tr capacity of hernetically sealed compressor. The condenser is of air cooled type equipped with necessary filters sections with necessary safety controls. The evaporator unit consisting of Dx type cooling coil, blower, 10 micron filters and all are housed in sheet steel casing. The power supply for all the equipments has been connected through control panel having MCB, Contactors, Scaners, control switches, PCBs, etc as per the standard design by the manufacturer of the AC plant with necessary protections .The unit incorporates with fire dampner,electronic controls and wired remote control.The conditioned air has been distributed through GSS ducting with volume controldiffusers. The return air has been collected from the ceiling. The installation is provided with false ceiling using gypsum / armstrongboard. Note: This plant is connected with 2 nos of condensing unit in one evaporator unit. Hence this plant has been considered has 2nos.Make: Carrier.Year of installation:2012.Location: 5 axis machine shop. |
| 14 | 8.5 Tr capacity of air cooled ductable split Air conditioner comprising 2 nos of condensor unit having 4 nos of 4.25 Tr capacity of hernetically sealed compressor with R-407C refrigerant. The condenser uint is equipped with necessary expansion valves & safety controls. The evaporator unit consisting of 1 no of 17 Tr capacity Dx type coiling coli, blower running with 230 volts single phase motor & standard filters. All are housed in sheet steel casing. The power supply for all the equipments has been connected through control panel having MCB, Contactors, Scaners, control switches, PCBs & necessary protection asOEM standards.The conditioned air has been distributed through GSS ducting with volume controldiffusers. The return air has been collected from the ceiling. The installation is provided with false ceiling using gypsum / armstrongboard.Note: This plant is connected with 2 nos of condensing unit in one evaporator unit. Hence this plant has been considered has 2nos.Make: Bluestar, Model No: DSA1021R2Year of installation:2016.Location: C-SCAN. |
| 15 | 11 Tr capacity ceiling mounted type ductable split Air conditioner comprising of 2 nos of 5.5 Tr reciprocating hermetically sealed compressors. The evaporator unitconsisting of evaporator coil, blower, 10 micron filters and all are housed in sheet steel casing.The power supply for all the equipments has been connected through control panel having MCB, Contactors, control switches, PCBs, etc as per the standard design by the manufacturer of the AC plant with necessary protections ofelectronic type controls and wired remote controller. The conditioned air has been distributed through GSS ducting with volume controldiffusers. The return air has been collected from the ceiling. The installation is provided with false ceiling using gypsum / armstrongboard.Make: BLUE STAR, Model - DSA 1321Year of installation:2011.Location: NCAD 1st Floor & 2nd Floor @ ACD Phase -II. |
| 16 | 11.0 Tr Capacity air-cooled condensing system comprising of 2 nos of 5.5 Tr hermitically sealed reciprocating compressors connected to AHU driven by 415 Volts, 50 Hz, 5 HP induction motor. The filter sections are provided with pre filters and microvee are installed in the AHU. The HOODED TYPE MINI PLEATE FILTERS (High efficiency particulate air) designed to remove particles down to 0.3 Microns from air streams with an efficiency of 99.997%have been installed at supply grills inside the conditioned facility to maintain class 10000 cleanliness. The Ultraviolet germicidal irradiation (UVGI) are provided for reduction in bacterial count / virus. The necessary instrumentation like magnelic gauge, air shower, temperature indicators and the strip air heaters with thermostat are provided to maintain 55 ± 5 % RH as per the site requirement. The power supply for all the equipments has been connected from motor control centre (MCC) with necessary SFU, motors starters and protections.The MCC comprising ofthe following switchgears:Incoming :63A 3P, MCCB – 1Nos.Outgoing:1) 32A, DOL starter with MPCB – 2No.( For AHU & Condensing unit)2) 32A, TP MCB – 1No.(For Air Shower)3) 16A, DP, MCB – 3No. for heaters.Make of the condensing unit: LG.Electronics and the make of the AHU is CLIVET India.Year of installation:2010.Location: MEMS lab of Materials Science Division |
| 17 | 11.0 Tr (2 x 5.5 Tr) Capacity air-cooled condensing system with hermitically sealedcompressors connected to DX typeAHU driven by 415 Volts, 50 Hz, 5 HP induction motor. The filter sections are provided with pre filters , micro fillter and air heaters are installed in the AHU. The HOODED TYPE MINI PLEATE FILTERS (High efficiency particulate air) designed to remove particles down to 0.3 Microns from air streams with an efficiency of 99.997%have been installed at supply grills inside the conditioned facility to maintain class 10000 cleanliness. The Ultraviolet germicidal irradiation (UVGI) are provided for reduction in bacterial count / virus. The necessary instrumentation like magnelic gauge, air shower, dehumidifier for contol the RH, temperature controller and the strip air heaters with thermostat are provided to maintain 55 ± 5 % RH as per the standards. The power supply for all the equipments has been connected from motor control centre (MCC) with necessaryMCCBs, VFD drive/Soft starterfor AHU motorsand protections.The MCC comprising ofthe following switchgears:Incoming :63A 3P, MCCB – 1Nos.Outgoing:1)5HPVFD drive/soft starter - 1no( AHU Moter)2)DOL starter with MPCB – 2No.( For 11.0Tr Condensing unit)3) 16A, DP, MCB – 3No. for heaters.4)Set of LED type indication lamps Note : The HEPA filter for all the clean room will be supplioed by NAL as and when required. The vendor is instructed quote for replacement of necessary free filters, micro vee filters and other type filters as and when required except HEPA filter in this offer.Make of the plant: Bluestsr Year of installation:2012Location:SED |
| 18 | 16.5 Tr (5.5 Tr x 3 No\"s) capacity factory built, microprocessor controlled energy efficient air cooledDx-type condensing unit refrigeration system with scroll compressors with R-407 C refrigerant. The AHU driven by 415 Volts, 50 Hz, 15 HP induction motor. The filter sections are provided with pre filters and microvee are installed in the AHU. The HOODED TYPE MINI PLEATE FILTERS (High efficiency particulate air) designed to remove particles down to 0.3 Microns from air streams with an efficiency of 99.997%have been installed at supply grills inside the conditioned facility to maintain class 10000 cleanliness. The necessary instrumentation like magnelic gauge, air shower, temperature indicators and the strip heaters (6 KW heater bank) with thermostat are provided to maintain temperature of 22 ± 2º C and 55 ± 5 % RH as per the standards. The Ultraviolet germicidal irradiation (UVGI) are provided for reduction in bacterial count / virus. The conditioned air & return has been distributed through GSS ducting with volume control diffusers from the ceiling. The installation is provided with cealing panel & wall panel. The power supply for all the equipments has been connected through motor control centre (MCC) with necessary motors starters and protections. The MCC is comprising of the following switchgears:Incoming :200 A, 3P, 16kA MCCB as an incomer. - 1 NoOutgoing:1. VFD for 3 phase, 15 HP squirale cage induction motor with necesary MCCB as an incomer, power contactor & control accessories etc for AHU - 1 No2. Star-Delta starter with suitable rated AC-3 duty contactor, illuminated start / stop push buttons & other accessories & MCCB as incomer for 15 HP squiral cage induction motor (as standby for AHU) - 1No3.Condensing units 63 A, 3 P, 16 kAMCCB - 3 Nos 4. 16A, 2P, MCBs and AC-1 duty contactors for the heaters - 3 Nos5. LED type indication lamps with control SP MCB.- 1 Set.6. Digital typye multi deta Meter (MDM) to read current , voltage, kilowatt, energy & power factor having RS-432 port with necessary ratedCT &short links. - 1 No Note : The HEPA filter for all the clean room will be supplioed by NAL as and when required. The vendor is instructed quote for replacement of necessary free filters, micro vee filters and other type filters as and when required except HEPA filter in this offer.Make of the condensing unit: Voltas, Model - ACDCUA05512DMake of the AHU: Air blow, Make of the airshower: EnvairYear of installation: 2019 & Location: SED 2nd Floor. |
| 19 | 55 Tr (11 Tr x 5 No\"s) capacity factory built, microprocessor controlled energy efficient air cooledDx-type condensing unit refrigeration system with scroll compressors with R-407 C refrigerant . The AHU driven by 415 Volts, 50 Hz, 20 HP induction motor. The filter sections are provided with pre filters and microvee are installed in the AHU. The HOODED TYPE MINI PLEATE FILTERS (High efficiency particulate air) designed to remove particles down to 0.3 Microns from air streams with an efficiency of 99.997%have been installed at supply grills inside the conditioned facility to maintain class 10000 cleanliness. The necessary instrumentation like magnelic gauge, air shower, temperature indicators and the strip heaters (10 KW heater bank) with thermostat are provided to maintain temperature of 22 ± 2º C and 55 ± 5 % RH as per the standards. The Ultraviolet germicidal irradiation (UVGI) are provided for reduction in bacterial count / virus. The PLC / contractor based control logic has provided for day-to-day operations. The conditioned air has been distributed through GSS ducting with volume controldiffusers from the ceiling. The return air has been collected through floor. The return air duct has been painted using epoxy paint. The installation is provided with false ceiling. The power supply for all the equipments has been connected through motor control centre (MCC) with necessary motors starters and protections. The MCC is comprising of the following switchgears:Incoming:315A, 25 kA 4P MCCB with thermal magnetic releases RHOM.- 1 No.Outgoings:1. Automatic star/delta starter suitable for 20 HP 3 phase, 4 pole, 50 Hz, Induction motor with suitable rated AC-3 duty contactor for blower motor- 1 No.2. Direct on line(DOL) starter suitable for 3 phase, 415 Volts, 50 Hz- 5 Nos3. Set ofLED type indication lamps for mains. – 1 Set4. Multi data digital meter.– 1 No.5. Suitable rated CTs.– 1 SeNote : The HEPA filter for all the clean room will be supplioed by NAL as and when required. The vendor is instructed quote for replacement of necessary free filters, micro vee filters and other type filters as and when required except HEPA filter in this offer.Year of installation: 1998 (Blower section) & 2019 (Condensing unit & coil)Make of the condensing unit: Voltas, Model - ACDCUA11012D. |
| 20 | 36 HP (12 HP x 3 No\"s) capacity factory built outdoor type, air cooled variable refrigerant flow(VRF) / variable refrigerant volume (VRV) condensing units having hermetically sealed inverter type scroll compressors with R-410A refrigerant.The AHU driven by 415 Volts, 50 Hz, 7.5 HP induction motor. The filter sections are provided with pre filters and microvee are installed in the AHU. The HOODED TYPE MINI PLEATE FILTERS (High efficiency particulate air) designed to remove particles down to 0.3 Microns from air streams with an efficiency of 99.997%have been installed at supply grills inside the conditioned facility to maintain class 100000 cleanliness. The necessary instrumentation like magnelic gauge, air shower, temperature indicators and the strip heaters with thermostat are provided to maintain temperature of 22 ± 2º C and 55 ± 5 % RH as per the standards. The conditioned air & return has been distributed through GSS ducting with volume control diffusers from the ceiling. The power supply for all the equipments has been connected through motor control centre (MCC) with necessary motors starters and protections & VFD. The MCC is comprising of the following switchgears:Incoming : . 250A, 25 kA 3P MCCB - 1 No.OUTGOING FEEDERS : 1. Star-Delta starter with AC-3 duty contactor suitable for 7.5 HP squiral cage induction motor (as standby for AHU with necessary interlock with VFD fedder) - 1 No2. 125A, 3P, 16 kA MCCB- 3 Nos3. 63A, 3P, 16 kA MCCB - 5 Nos4. 40A, 3P, 16 kA MCCB - 3 Nos.5. LED type indication lamps with control SP MCB. - 1 Set.6. Digital type multi deta Meter (MDM) to read current , voltage, kilowatt, energy & power factor having RS-432 port with necessary ratedCT &short links.- 1 No.Note : The HEPA filter for all the clean room will be supplioed by NAL as and when required. The vendor is instructed quote for replacement of necessary free filters, micro vee filters and other type filters as and when required except HEPA filter in this offer.Make of the condensing unit: LG, Model - JRUN120LLS4Make of the AHU: Zeco, Model - ZDS-80 & Make of the airshower: EnvairYear of installation: 2017 |
| 21 | 42 HP (14 HP x 3 No\"s) capacity factory built outdoor type, air cooled variable refrigerant flow(VRF) / variable refrigerant volume (VRV) condensing units having hermetically sealed inverter type scroll compressors with R-410A refrigerant.The AHU driven by 415 Volts, 50 Hz, 25 HP induction motor. The filter sections are provided with pre filters and microvee are installed in the AHU. The HOODED TYPE MINI PLEATE FILTERS (High efficiency particulate air) designed to remove particles down to 0.3 Microns from air streams with an efficiency of 99.997%have been installed at supply grills inside the conditioned facility to maintain class 10000 cleanliness. The necessary instrumentation like magnelic gauge, air shower, temperature indicators and the strip heaters with thermostat are provided to maintain temperature of 22 ± 2º C and 55 ± 5 % RH as per the standards. The Ultraviolet germicidal irradiation (UVGI) are provided for reduction in bacterial count / virus. The conditioned air & return has been distributed through GSS ducting with volume control diffusers from the ceiling. The installation is provided with cealing panel & wall panel. The power supply for all the equipments has been connected through motor control centre (MCC) with necessary motors starters and protections. The MCC is comprising of the following switchgears:Incoming : 200 A, 3P, 16kA MCCB with thermal magnetic releases and shunt releases. - 1 No.OUTGOING FEEDERS : 1. VFD for 3 phase, 25 HP squirale cage induction motor - 1 No2. Star-Delta starter with AC-3 duty contactor suitable for 25 HP squiral cage induction motor (as standby for AHU with necessary interlock with VFD fedder) - 1No.3. 63 A, 3 P, 16 kAMCCB ( Condensing units ) - 4 Nos 4. Heater bank controls having 16A, 2P, MCB and16 A, 3 pole AC-1 duty contactors. - 4 sets.5. LED type indication lamps with control SP MCB. - 1 Set.6. Digital type multi deta Meter (MDM) to read current , voltage, kilowatt, energy & power factor having RS-432 port with necessary ratedCT &short links.- 1 No.Note : The HEPA filter for all the clean room will be supplioed by NAL as and when required. The vendor is instructed quote for replacement of necessary free filters, micro vee filters and other type filters as and when required except HEPA filter in this offer. Make of the condensing unit: LG, Model - JRUN140LLS4Make of the AHU: Zeco, Model - ZDS-150 & Make of the airshower: Sam AirYear of installation: 2020 |