| 1 | SH-I: SITC of Light Fixtures. |
| 2 | Supply Installation Testing and Commissioning of asymmetric LED luminaire, housing made up of pressure die cast aluminium Alloy with effective thermal management, sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of 120 lumen/Watt and a minimum system lumen output of 14,700 lumens, CCT 5700 K.Fixture shall have a CRI of 80. Fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP65 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=07. Product shall be with Asymmetric beam angle and the minimum beam angle should be 45⁰x75⁰. Driver must mandatorily be DALI dimmable driver. Fixture driver shall have an operating voltage range of 120-277 V, surge protection of >=4KV, PF >0.9 and THD<20%. Fixture should comply with the parameters as per IS10322. |
| 3 | Supply Installation Testing and Commissioning of asymmetric LED flood light luminaire, housing made up of pressure die cast aluminium Alloy with effective thermal management, sturdiness and embossed brand name/logo name of manufacturer. Fixture should have a minimum system efficacy of 120 lumen/Watt and a minimum system lumen output of 24,000 lumens, CCT 5700 K.Fixture shall have a CRI of 70. Fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=08.Product shall be with asymmetric beam angle and the minimum beam angle should be 10⁰x 50⁰. Driver must mandatorily be DALI dimmable driver. Fixture driver shall have an operating voltage range of 120-277 V, surge protection of >=4KV, PF >0.9 and THD<20%. Fixture should comply with the parameters as per IS10322. |
| 4 | Supply Installation Testing and Commissioning of asymmetric LED flood light luminaire, housing made up of pressure die cast aluminium Alloy with effective thermal management, sturdiness and embossed brand name/logo name of manufacturer. Fixture should have a minimum system efficacy of 120 lumen/Watt and a minimum system lumen output of 19,000 lumens, CCT 5700 K.Fixture shall have a CRI of 70. Fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=08.Product shall be with asymmetric beam angle and the minimum beam angle should be 10⁰x 50⁰. Fixture driver shall have an operating voltage range of 120-277 V, surge protection of >=4KV, PF >0.9 and THD<10%. Fixture should comply with the parameters as per IS10322. LED driver shall have inbuilt output short circuit & over voltage protection. Driver should have self protection of 440V P2P for 8 hrs and high cut of 325V with auto restart provision. |
| 5 | SH-II: SITC of Controllers and Desktop Computer |
| 6 | Supply Installation Testing and Commissioning of DIN rail mounted 12 channel relay controller to control any type of switched load. Controller housing shall be polycarbonate with DIN mount type. Controller shall have Single-Pole Single-Throw feed through power circuit design equivalent to 12 pole contactors & each pole should be controllable via system network. Each Switched loads should support 16A inductive load per channel upto max. of 180A per device. Device should support single phase & neutral or three phase & neutral (Star). Controller should have service override switch and shall be accessible from the front panel.Controller supply voltage shall be 100-240AC and system Output DC current 200mA which can support 10 button panels without any additional power supply. Controller shall have ability to operate under temperature from 0 to 50 degreeandrelative humidity from 0 to 90% condensing. (Make: ABB / Philips or Equivalent) |
| 7 | Supply Installation Testing and Commissioning of DIN rail mounted 3 Channel DALI high frequency ballasts controller. Controller housing shall be polycarbonate with DIN mount type. DALI controller shall be compatible with DALI electronic low voltage transformers and DALI LED fixtures.Controller DALI outputs allowing it to control up to 64 DALI devices per channel or port and 192 DALI devices per controller. DALI control signals can be programmed to operate automatically isolate the power circuit when all associated DALI channels are at 0% with the support of internal switches. Controller supply range shall be 100-240V 50/60Hz. Controller shall be capable to show Lamp failure, Driver failure,Driver runtime tracking,Switched output runtime tracking,Emergency test reporting, Device online/offline status diagnostic functions. Controller shall have ability to operate under temperature from 0 to 50 degree andrelative humidity from 0 to 90% condensing. (Compatible to LMS)(Make: ABB / Philips or Equivalent) |
| 8 | Supply Installation Testing and Commissioning of DIN rail mounted flexible network communications bridge. Controller housing shall be polycarbonate with DIN mount type. Device shall have two opto-isolated RS485 ports enable the gateway to implement a trunk and spur topology, with each spur being electrically isolated from the others so a fault in one section of the network will be contained. The protocol communication with third-party systems such as audio-visual, blind controllers, Modbus meters and building automation systems, providing an integrated approach to total building control and energy management. Gateway shall also be capable of transmitting or receiving up to 512 channels of DMX, with automatic protocol conversion and task triggering. Device operating voltage shall be 12-24V DC. Device shall have minimum two numbers of RS485 communication ports. Device shall have ability to operate under temperature from 0 to 50 degree and relative humidity from 0 to 90% condensing. (Make: ABB / Philips or Equivalent) |
| 9 | Supply Installation Testing and Commissioning of DIN rail mounted regulated power supply, designed to supplement the DC supply to network communication devices. Controller housing shall be polycarbonate with DIN mount type. Device operating voltage shall be 110-240V, 50/60Hz. Device should have self-resetting overload protection,short circuit protection andautomatic thermal shutdown. Device shall have ability to operate under temperature from 0 to 50 degree and relative humidity from 0 to 90% condensing.(Make: ABB / Philips or Equivalent) |
| 10 | Supply Installation Testing and Commissioning ofDIN rail mounted multipurpose Ethernet Gateway to integrate multipurpose devices along with the control system. Device used to provide remote control of sites and link multiple sites together, using the Internet or a corporate LAN as a backbone. Device supports the TCP/IP protocol, with static or DHCP assigned IP addressing. Interface incorporates a Programmable Logic Controller that can process comprehensive conditional and sequential logic and arithmetic functions and time-based events and scheduling. Device operating voltage shall be 12-24V DC. Device shall have one number of RS485 communication port and Ethernet port. Device shall have ability to operate under temperature from 0 to 50 degree and relative humidity from 0 to 90% condensing. (Make: ABB / Philips or Equivalent) |
| 11 | Supply Installation Testing and Commissioning ofDisplay keypad with Central Display to present multiple pages of functions & system Information. Keypad shall possess fully programmable options for Individual control / group control / Scene control / Tasks etc. Keypad shall be wall mounted on modular box and the front cover with Backlight, built in proximity integrated into the system. Loaded icons like presentation scenario, meeting scenario, masterOn/Off, Power saving mode etc. along with a LED indicator for each operation. Keypad button function can change when navigating between the up to 16 pages.Device operating voltage shall be 12-24V DC. Device shall have one number of RS485 communication port. Device shall have ability to operate under temperature from 0 to 50 degree and relative humidity from 0 to 90% condensing.(Make: ABB / Philips or Equivalent) |
| 12 | Supply Installation Testing and Commissioning of multi-user control system management and monitoring software tool. Software shall provide users with full visibility of the lighting and energy management system status and performance, while enabling simple local or global system adjustments. Software should supports Complete Control, Simple Scheduling, Manage routine maintenance, strike the balance, identify energy savings initiatives based on the current usage, tailored control for individual light fitting functions.(Make: ABB / Philips or Equivalent) |
| 13 | Supply Installation Testing and Commissioning of Desktop computer for the purpose of control system and visualization. (i7, 13th gen, MB, 32GB RAM, 512GB SSD, 21.5\" Monitor, KB+Mouse+1KVA UPS) along with Original Windows OS 11, MSO Wireless Keyboard & Mouse etc. including programming charges, LMS software with latest update and license valid for all make/type of Lighting fixtures, integration of all components etc. to enable the control of LMS as required. |
| 14 | SH-III: Miscellaneous Works |
| 15 | Supply and Laying of 25mm dia medium class PVC conduiton surface / recessed etc as required. |
| 16 | Supply and laying of 3 core x 2.5 Sq.mm Cu Flexible PVC insulated, PVC round sheathed multicore industrial flexible cables for voltage grade upto 1100V as per IS694:1990 with upto date amendments in existing PVC pipe etc. as required. |
| 17 | Supply and laying of 2 core x 2.5 Sq.mm Cu Flexible PVC insulated, PVC round sheathed multicore industrial flexible cables for voltage grade upto 1100V as per IS694:1990 with upto date amendments in existing PVC pipe etc. as required. |
| 18 | Supplying and Making end termination with suitable gland for 3 Core x 2.5 Sq.mm copper flexible conductor unarmoured power cable of 1.1KV grade as required. |
| 19 | Supplying and Making end termination with suitable gland for 2 Core x 2.5 Sq.mm copper conductor unarmoured power cable of 1.1KV grade as required. |
| 20 | Supply and Fixing of 7/8 Segment Double door DB Enclosure including supply and fixing of following MCB\"s etc., as required. For Incoming:a) 63A 4P B-Curve MCB – 01 No. b) 20A DP B-Curve MCB – 01 No (spare).For Outgoing:a) 10A/20A B-Curve MCB – 24 Nos. |
| 21 | Supply and Laying of UTP Flexible CAT6 Cable (Non Armoured) with Necessary accessories etc. as required. |
| 22 | Dismantling the existing oldlight fixtures and shifting the same to AAI Store or location as per the instructions of Engineer -in-Charge. |
| 23 | Dismantling the existing oldcontrol system and shifting the same to AAI Store or location as per the instructions of Engineer -in-Charge. |
| 24 | SH-IV : AICMC All Inclusive Comprehensive Maintenance Contract for the entire Lighting System comprising of all items installed in departure and canopy area at T1 and T4 Terminal building as per Specifications & Schedule of Work including providing Services with corrective maintenance resolution, preventive maintenance as per OEM recommendations, cleaning and proper angle adjustment of fitting, LMS software updation etc. with dedicated Call Center facility 24 x 7 hours with dedicated E-mail ID, telephone No. or with any other quick response facilities and effective routine maintenance as per OEM standard andas per Specialterms and conditions and direction of Engineer-in-charge. |
| 25 | First Year after DLP (Considered 3% on cost of Items at SH-II only) |
| 26 | Second Year after DLP (Escalation @ 5% on 1st year after DLP) |
| 27 | Third Year after DLP (Escalation @ 5% on 2nd year after DLP) |
| 28 | Fourth Year after DLP (Escalation @ 5% on 3rd year after DLP) |
| 29 | Fifth Year after DLP (Escalation @ 5% on 4th year after DLP) |