| 1 | Cleaning and maint of sewage system including removing of all types of bloackages from wash hand basins, bottle traps, kitchen sink, water closets, Nahani traps / floor traps / gully traps including taking out carefully and refixing the same MS/CP/PVC grating, soil waste/rain water pipes running on walls, bldgs or in trenches including junction holes of any description, sewage lines and man holes and septic tanks of any size and depth upto the last manhole to septic tanks of central sewage system to keep smooth functioning without any blockage of any description and in any situation with manually or mechanically processes in offrs Married Accn Complex, office under AGE (B/R) Niwaru all as specified incl all tools and plants, bamboos, iron rod, bucket, rope, ladder etc complete all as specified and directed.Note : (i)Contractor has to provide 02 Nos of safaiwals as required on daily basis to attend complaints assigned by sub division. (ii) All daily compalints (Including sunday and holiday) will be rectified within 24 hrs from the time of issue the complaint, other wise compensation will be charged @ Rs. 200 per day in addition to above every additional day delayed will be charged @ Rs. 50 per day. |
| 2 | Scooping and taking out sludge and foreign material from septic tank, soak well and manholes of any description and any depth including removing and re-fixing of manholes covers, septic tank and soak well cover etc incl appliances required for safe disposal of sludge and foreign material by carrying out the same covered van/trolley out side defence land and it should be disposed off at such place which is not detrimental to public health and spread lime on the disposed off sludge and bleaching powder near the septic tank or soak well to maintain hygiene complete all as specified and directed. |
| 3 | M&L for making arrangment for bypass to nearest manhole or line to keep sewage flow continuous providing required necessary T&P such as portable pump set, flexible hose pipe etc all as required at pump set, flexible hose pipe etc all as required at site :-(a)Upto 30mtr distance |
| 4 | (b)Beyond 30mtr but upto 60mtr distance |
| 5 | Scooping and taking out water and foreign material from septic tank, soak well and manholes of any description and any depth including removing and re-fixing of manholes covers, septic tank and soak well cover etc and appliances required for safe disposal of sludge and foreign material by carrying out the same out of defence land and spread lime on the disposed off sludge and bleaching powder near the septic tank or soak well to maintain hygiene complete all as specified and directed. |
| 6 | M&L for cleaning of sewage line and blockages using sewer jetting machine or any other similar machine and make it functional complete all as specified and directed. |
| 7 | Demolition and breaking up 150mm dia drain pipes (salt glazed ware, AC or reinforced concrete NP2 or NP4) incl PCC packing under hunching against the sides of bed and complete PCC bed complete all as specified and as directed. |
| 8 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m indepth for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc1.5 m in depth and getting out in soft / loose soil complete all as specified and directed. |
| 9 | ,---ditto--- all as per item No 8 above but depth exc 1.5m but not exc 3m complete all as specified and directed. |
| 10 | Removing excavated material to a distance exc 50 m but n exc 250m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed. |
| 11 | M&L Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 12 | S&F 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed. |
| 13 | Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4type B1 smooth finished and reforming benching as required for 150mm bore pipe complete all as specified and as directed. |
| 14 | M&L forPCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe all as specified and directed. |
| 15 | Dismantling of damaged RCC Works (Cover slab of Manholes, Septic tanks or similar articles) of any description and in any position, completed all as specified and as directed. |
| 16 | M & L for providing precast cement concrete 1:1.5:3 type A1 (using 20 mm graded stone aggregate) for manhole cover with finished even and Smooth with using extra cement with 8 mm dia reinforcement @ 150 mm c/cbothwaysand placing & set in CM 1:6 complete all as specified and directed. Note:- Reinforcement shall be measured and paid separately. |
| 17 | S&F Mild steel TMT bar 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as directed and specified. |
| 18 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material outside of MD Land complete all as specified and directed. |
| 19 | M&Lfor brick work with sub-class \"B\" bricks (using old size bricks), straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed |
| 20 | M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed. |
| 21 | M&L PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 22 | M&L for rendering 15mm thick in cement mortar 1:4 on fair face of brick work or concrete surfaces finished even and smooth without using extra cement including mixing of WPC compound complete all as specified and directed.Note : WPC shall be measured and paid separately. |
| 23 | M&L for rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brick work of walls finished even and smooth without using extra cement complete all as specified and directed. |
| 24 | Supply only Integral Water proofing compound ISI marked complete all as specified and directed. |
| 25 | M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in surface channels and drains and benching including finishing the top of benching finished even and smooth with using extra cement complete all as specified and directed.Note : Forming fair finished channel for drain using extra cement will be measured and paid for separately. |
| 26 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified & directed. |
| 27 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified & directed. |
| 28 | M&L Providing cement concrete (1:3:6), type C-1 (using 20mm graded stone aggregate) as in lintels upto 1.50m clear span, cills steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parpets and railing upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering , slightly rounded or chamfered angles and throating including necessaryform works etc. complete all as specified & directed. |
| 29 | S&F in repair 110mm bore UPVC (SWR) pipes single socketed (type B conforming to IS-13592) in any length with rubber ring joints fixed to walls with suitable size clamp including taking down of old pipe complete all as specified & directed. |
| 30 | S&F in repair 75mm bore UPVC (SWR) pipes single socketed (type B conforming to IS-13592) in any length with rubber ring joints fixed to walls with suitable size clamp including taking down of old pipe complete all as specified & directed. |
| 31 | S&F in repair 110 mm UPVC (SWR) pipes single socketed (type B conforming to IS-13592) in any length with rubber ring joints laid in trenches or floors including taking out of old pipe complete all as specified & directed. |
| 32 | S&F in repair 75 mm UPVC (SWR) pipes single socketed (type B conforming to IS-13592) in any length with rubber ring joints laid in trenches or floors including taking out of old pipe complete all as specified & directed. |
| 33 | S&F 75 mmPVC (SWR) bends any radius with access door complete all as specified and directed |
| 34 | S & F 110 mmPVC (SWR) bends any radius with access door complete all as specified and directed |
| 35 | S&F in repair 75 mm diaPVC (SWR) branch piece, single (single Y) equal or unequal with access door including taking down complete all as specified and directed |
| 36 | S & F in repair 110 mm bore PVC (SWR), junction single, (Single T) equal or unequal with acess door including taking down complete all as specified and directed |
| 37 | S & F in repair 75 mm dia PVC (SWR), junction single, (Single T) equal or unequal with acess door including taking down complete all as specified and directed. |
| 38 | Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule \"A\"/BOQ |