| 1 | False ceiling Light |
| 2 | LED Panel light 2x2 ft., Supplying, installation, Testing & Commissioning ofPanel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 BurningHours with , 70% of initialLumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 3 | 36 watt (System lumen efficacy>135 lm/Watt) |
| 4 | Light Point wiring |
| 5 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modularswitch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS insulated copper conductor single core cable etc. as required. GroupC( light point, fan point & Exhust fan point) |
| 6 | Power Wiring |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (steel Conduit included in scope) |
| 8 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (Computer ) |
| 9 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (Computer ) |
| 10 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire (Incommer for Power & UPS line to DB box) |
| 11 | Cable Management system (CMS) |
| 12 | Providing and fixing 105 mm x 50 mm Cable Management System including all accssories on existing wall/Coloumn /Beam /Ceiling with 85mm flexible cover etc as required. (Internal Angle, External Angle, End cap, Base & Body joints, Tee, Flat Angle) |
| 13 | 6 Module frame with 2Nos Modular 5/6A switch + 2Nos. Modular 5/6A socket. |
| 14 | 3 Module frame with 1No. Modular 15/16A switch + 1No. Modular 15/16A socket. |
| 15 | DB, MCBs, CMS & Switch Socket |
| 16 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . |
| 17 | 12 way (4 + 36), Double door(Power & UPS) |
| 18 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 19 | 12 way , Double door (Lighting ) |
| 20 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 21 | Single pole (16 Ampere) |
| 22 | Single pole (6A) |
| 23 | Double pole |
| 24 | Supplying and fixing following rating, four pole, 415 V, MCB in the existingMCBDBcompletewithconnections,testingand commissioning etc. as required. |
| 25 | 63A |
| 26 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 27 | 40 A |
| 28 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 29 | 100 A, 16 KA,TPMCCB |
| 30 | Earthing |
| 31 | Earthing with Copper earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 32 | Providing and fixing 25 mm X 5 mm Copper strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 33 | Providing and fixing 25 mm X 5 mm copper strip onsurface or in recess for connections etc. as required. |
| 34 | Dismantalling and Refixing of CMS of Existing DB |
| 35 | Dismantalling and Refixing of Exixiting DBsform room to lab area |
| 36 | Dismantalling and Refixing of Exixiting CMS form above the working table level |