Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolishing cement concrete including disposal of material to all leads and lifts: |
| 2 | 1:2:4 or richer mix |
| 3 | Dismantling Stone /Tilesflooring laid in cement mortar including material within 50 metres lead stacking of serviceable material and disposal of unserviceable material to all leads and lifts |
| 4 | Thickness of tiles/stone upto 25 mm |
| 5 | Demolishing existing wall tiles/stone slab/stone cladding and plaster under tiles including disposal of rubbish to within 50 metres lead stacking of serviceable material and disposal of unserviceable material to all leads and lifts |
| 6 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing/panellings , Prelam wooden floorings and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Project Manager |
| 7 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, hold fasts etc. including disposal of unserviceable surplus material and stacking the serviceable material within 50 meterslead |
| 8 | Dismantling the exiting cabinets of depths upto 6oo mm including internal shelves/partitions etc . including disposal of unserviceable surplus material and stacking the serviceable material within 50 meterslead ( front area of cabinets shall be measured for payments ) |
| 9 | Dismantling of flushing WCs /bidets /washbasins /sinks of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable to all leads and lifts |
| 10 | Dismantling of C.I./PVC pipes etc per toilet including stacking of useful materials near the site and disposal of unserviceable to all leads and lifts |
| 11 | CIVIL WORKS |
| 12 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : |
| 13 | With cement mortar 1:4 (1 cement :4 fine sand)(internal) |
| 14 | With cement mortar 1:4 (1 cement :4 Coarse sand)(internal) includingwater proofing compound a s per manufacturers specs |
| 15 | Extra on above for mixing LW+ ( Pidilite ) water proofing as per manufacturer recommendations |
| 16 | Providing ,hoisting and fixing upto floor five level1:2:4 ( 1 cement :2 coarse sand :4 Stone aggregate 20 mm) reinforced cement concreteslabs including ,cost of required centering shuttering and finishing with neat cement punning on exposed surface |
| 17 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete : Thermo-Mechanically Treated bars |
| 18 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Project Manager, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : |
| 19 | Italian marble (Perlato, Rosso verona, Fire Red , William grey or Dark/Light Empladore equivalent stone )upto Rs 6000/- Sqm |
| 20 | Mirror polishing on marble work / stone work where ever required to give high gloss finish complete. |
| 21 | Granite work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the Granite shade (To be secured to the backing by means of cramps, which shall be paid for separately |
| 22 | Granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 23 | Area of slab upto 0.50 sqm |
| 24 | Area of slab over 0.50 sqm |
| 25 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut GRANITE for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 26 | Granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 27 | (Area of slabUpto 0.50 sqm) |
| 28 | Area of slab above 0.50 sqm |
| 29 | Same as2.7 above but on Floor |
| 30 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc . complete as per design approved by Project Manager. |
| 31 | Marble work. |
| 32 | Granite work. |
| 33 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxybased adhesive, including cleaning etc. complete. |
| 34 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 35 | Providing and fixing cramps of required size & shape in RCC /CC backing with cement mortar 1 : 2 ( 1 cement : 2 fine sand ) including drilling necessary hole in stones and embedding the cramp in the hole ( Fastener to be paid separately ) |
| 36 | Stainless steel cramps |
| 37 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 38 | Size of Tile 600x600 mm( Basic Price Rs 900 Sqm ) |
| 39 | Size of Tile 600x1200 mm( Basic Price Rs1200 Sqm ) |
| 40 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling/grouting and finishing complete as per direction of Project Manager. |
| 41 | Size of Tile 600x600 mm |
| 42 | Size of Tile 600x1200 mm |
| 43 | Providing and fixing Kajaria premium range tilesin approved shade 5.5 mm thickness or morein flooring, 400x400 mm size laid on a bedof 12 mm thick cement mortar 1:3 jointing with cement mixed with pigment to match the shade of tiles including carriage of materials in all leads and lifts (Basic price Rs 700/-Per Sqm) |
| 44 | Extra on above for providing 3mm groove using pvc spacers and grouting the joints with Kajariapremium unsanded groutin approved colour |
| 45 | Providing and fixing Kajaria high defination digital/equivalent ceramic tilesin approved wood shade or morein flooring,195 x1200 mm size laid on a bedof 12 mm thick cement mortar 1:3 jointing with cement mixed with pigment to match the shade of tiles including carriage of materials in all leads and lifts(195 X 1200 KajariaGres Tough Planks Hi -Defination Digital Ceramic Floor Tile) |
| 46 | Providing and laying any coloured / plaIn/ texture /digital tiles in skirting, risers of steps and dado on 12mm thick cement plaster 1:3(1 cement: 3 course sand) and jointed with white cement slurry and matching pigment etc (Basic price Rs 1100/-Per Sqm) |
| 47 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Project Manager complete. |
| 48 | Upto 5mm depth and 5 mm width |
| 49 | Same as above but between stone cladding |
| 50 | FALSE CEILING |
| 51 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, |
| 52 | 12.5 mm thick tapered edge gypsum moisture resistant board |
| 53 | Providing and fixing false ceiling as per 3. 1 above but in lieu of Gypsum board providing and layingin situ P.O.P. with metal lath and plaster ceiling in plain / curved profile , complete with necessarycut-outs for services out lets as described in item No 1 above . |
| 54 | Providing and fixing upto 100 highPOP on GI frame as 3.2 abovevertical band on the edges of False Ceiling |
| 55 | Providing and fixing Double Layer Ceiling System , using 12mm thick commercial ply in lieu of Gypboard ceiling in item 2.1 as first layer & using 4 mm thk vineerin approved patternas second layer fixed to each other as per drawing and specisfications Vineer basic Price Rs 1500/- Sqm |
| 56 | P/F ceiling rafterswith 4mm vineer ( wenge shade )of approved design/patternand Century make fixedover rectangular box of 75X100 crosssection made by joining the 19mm comm. Ply with grooves as per the drawing. Ply shall be fixed on to the partition/ pane/wall with pvc fastners. |
| 57 | PARTITIONS / WALL PANELLING/STORAGES |
| 58 | Fixed in Situ Partition / Panelling Frame Work: |
| 59 | Providing and fixing in position mirandi wood framework to fit site for partitions and panelling as follows : |
| 60 | 50mm x 50mm @ 400 mmcentre to centre both ways for straight partitions (for full height and low height partitions). |
| 61 | Item include cost towards providing & applying fire retardent anti bacterial paint. All complete as per specifications, drawings, design intent and instructions of the Architect. |
| 62 | 50mm x 25mm @ 500 mmcentre into centre or as required as per design intent (for wall panelling). |
| 63 | Item include cost towards providing & applying fire retardent anti bacterial paint. All complete as per specifications, drawings, design intent and instructions of the Architect. |
| 64 | Notes:For Item No. 4.1-4.2 |
| 65 | For full height partitions frameworkshall be provided till the bottom of roof slab and only the visible area shall be measured for payment. |
| 66 | Center to center spacing may vary to make provision for fixing dado rail / to adjust the level of glass orfor fixing counter / storage units or otherwise as per site requirement. |
| 67 | No extra payment shall be made for reduction in framework opening as indicated in the drawing or as instructed by theArchitect. Framework shall be rigidly secured to floor and ceiling by dash fasteners etc. atmaximum 600mm c/c. |
| 68 | For framework of partition / panelling wherever change of material or joint in the skin material occurs, an additional member must be provided for proper strength & shall beof the same section & size asthe other frames without any additional payment. |
| 69 | Cost towards skinning and finishing shall be paid for in the relevant item. |
| 70 | Providing and fixing to straight partition, panelling framework, First Skin as per following specifications: |
| 71 | 12 mm thick BWR Ply. 400mm c/c both wayson the framework. Joints staggered on either sides of the partitions to avoid through joints. |
| 72 | All complete as per specifications, drawings, design intent and instructions of the Architect. |
| 73 | Note for Item 4.2: |
| 74 | Net area of BWR ply appliedshall be measured for the purpose of payment. |
| 75 | Providing and fixing Second Skin on existing straight / curved partition/panelling as per following specifications: |
| 76 | 6mm thick Exterior Grade MDF boardfixed with suitable adhesive & fully threaded parallel shank screws at max. 400mm c/c both ways. Joints staggered on either sides of the partitions to avoid through joints. Providing grooves of size 6mm x 6mm or as per design intent as specified below or as instructed. |
| 77 | All complete as per specifications, drawings, design intent and instructions of the Architect. |
| 78 | Notes for Item 4.3: |
| 79 | Whereverply / board is applied in more than one layer the joints in each layer shall be staggered. First layer (skin) will be screw fixed andsubsequent layers shall bescrewed as well as glued with suitable adhesive. |
| 80 | Net area of ply / boardappliedshall be measured. For the purpose of payment net rectilinear area shall be measured. Where Ply isapplied in more than one layer each layer shall be measured and paid for separately. |
| 81 | Providing , fixing and finishingin 1.0mm thick laminate over full height /free standing partition / wall paneling / doors / else where as instructed. Laminate shade, pattern &surface finish shall be as follows. The direction of Grain of print / texture and grooves shall be as per design intent. The laminates shall be fixed with adhesive of approved quality. ( Basic Price of Laminate Rs 600/- Sqm) |
| 82 | All complete as per Manufacturer\"s specifications, approval and instructions of the Architect. |
| 83 | Mode of Measurement:Net area applied shall be measured for payment. |
| 84 | Providing & fixing teak wood moulding of approx. finished size 19mm x 12mm.( Mode of Measurement:Net running length shall be measured for payment). |
| 85 | Mode of Measurement:Net running length shall be measured for payment. |
| 86 | Providing & fixing to curved / straight partition / paneling / doors or elsewhere as instructedmelamine pressed3.5 - 4.0 mm thick Decorative veneer ply of group match and of following origin, making grooves, includingprotecting with two coats of sealer and two coats ofmelamine polish. |
| 87 | Century : White Oak or equivalent priced vineer of other shade |
| 88 | Extra on above for providing and fixing the vineer on old works including removing the existing paint /polish as well as removing and refixing the doors/almirah shutters ets |
| 89 | Providing & applying wall paper approved equivalent on existing surface with suitable adhesive as per manufacturer\"s specifications. |
| 90 | All complete as per Manufacturer\"s specifications, approval and instructions of the Architect/Employer. Mode of Measurement:For thepurpose of payment net area of the surface applied shall be measured.Basic Price of Wall Paper Rs 800/- Sqm |
| 91 | Providing and fixing in position fabric foam panels. Panels of size as per site in approved pattern and with following specifications :- |
| 92 | Panels with base of 6mm thick BWR ply.Padding with 6mm thick white foam suitably glued and wrapped all around the edges including corners. Clad with markeen, securely fixed in place to the back of the framing and finished in fabric of basic rate Rs.750/ per mtr. excluding taxes and transportation. Panels shall be mounted on the existing partiton / wall panelling surface with levels varying from zero to +150mm created using mirandi wood sections as required. |
| 93 | All complete as per specifications, drawings, design intent and instructions of the Architect. |
| 94 | STORAGE |
| 95 | Carcasse: |
| 96 | Upto 600 mm clear depth Includes back ,base and two sides. 25mm thick pre laminated board(both sides laminated). Doubled edges by adding 18 mm exterior grade MDF Board to the 25mm thick pre laminated boardback.Alledges & visible sides of carcasselaminated in approved colour Tropical Teak; Code no. 3153, Ref. New Mikacat., i-finish/approved equivalent / approved equivalent and counter side in white colour. 24 mm high wenge wood skirting. |
| 97 | Shelving: |
| 98 | 19 mm thick pre laminated board(both sides laminated). Bothside laminated in approved colourTropical Teak; Code No. 3153; Ref. New Mika cat.; I-finish / approved equivalentr. All shelves resting on S.S studs. Edge profile matching . |
| 99 | Back: |
| 100 | 19mm thick pre laminated board(both sides laminated).Backsides laminated in 0.6 mm th. white colour laminate. Front/visibleside laminated inapproved colourTropical Teak; Code No. 3153; Ref. New Mika cat.; I-finish / approved equivalentr. |
| 101 | Top skirting: |
| 102 | Doubled edges by adding 18 mm exterior grade MDF Board to the 25mm thick pre laminated boardback.Wrappedin 0.8mm thk. Laminate,on two sides. |
| 103 | Shutter: |
| 104 | 19mm thick pre laminated board(both sides laminated) with postformed edges.Both side laminated approved equivalent Colour Tropical Teak; Code No. 3153; Ref. New Mika cat.; I-finish / approved equivalent r. .Counter side in white colour.All vertical edges shall be postformed as per approved profile.All other edges shall be provided with matching PVC edge banding . Grooves in shutter shall be provided and grain direction shall be as per design intent. |
| 105 | Handles & Accessories: |
| 106 | Shutters having 331 mm long Aluminiumhandles( one per shutter) ref. Hettich cat.9071082. Fourno.s Auto closing Hinges per shutter with Dampner ref. Hettich cat. no.73913+72983+60581.Shelves rest on S.S. Studs. |
| 107 | 1 nos. tower bolts for every pair of shutters, Multipurpose Locks for storage shutters with a set of keys Ref. hettich cat.no. N6100. |
| 108 | All complete as per drawing, approval and instructions of the Project Manager |
| 109 | Same as above but without shutters |
| 110 | Same as above but without shutters depth upto 450 mm |
| 111 | Providing and fixingfollowing in both Kitchen |
| 112 | Providing and fixing low ht factory made modular kitchen cabinets in modular type knockable cabinet boxes under counterstorageunit for Kitchen upto 600 deep in 19mmthick. HDHMR board construction with 6mm thick ply backing.Thevertical divisions shall be as per the drawing/details at spacing with 19mm HDHMR board not more than 450 mm.All internal surface of storage counter shall be in 1mm thick white Lamiate finish.All edges will finished with 18mm wide 2mm thick PVC edge banding.All the shutters shall be made in 19mm thk. BWP Plywith 1.5 mm thick premium acrylic sheet on exterior side and 1 mm thick laminate on interior sides auto closing hinges ( hettich make ) and upto 4 mm thk margins polished in matching shade. Allshuttersshall have tubular Kich make CHR104C equivalent approved make handlesand these shall be fixed with auto (soft) closing hinges. ( The shutter will include fixing with automatic hinges of Hettich make ). Upto one shelf per module , should be supported on approved quality SS pins and shall be adjustable for different heights as per requirements. All hinges shall be soft auto closing type having capacity to take load of the structure. |
| 113 | Providing and fixing factory made modular kitchen cabinets in modular type knockable cabinet boxes over counter storage unitupto 375mm depth and 700mm high made out of 19mm thick HDHMR boards for verticals, top, bottom, and intermediate vertical partitions @600 c/c or part thereof and backing of 6 mm th. HDHMR ply. The inside (interior) of storage to be finished with 1mm thick laminate and exterior sides is to be finished with 1.5mm premium acrylic complete in all respects as per design.All edges will finished with 18mm wide 2mm thick PVC edge banding.Upto one shelf per module , should be supported on approved quality SS pins and shall be adjustable for different heights as per requirements. All hinges shall be soft auto closing type having capacity to take load of the structure. |
| 114 | Same as above but without shutters |
| 115 | Providing fixing telescopic channels of following length with necessary screws etc complete as per directions |
| 116 | 450 mm ( Cat no.Hettich 9114275 ) |
| 117 | 550 mm (Cat no.Hettich 9114277 ) |
| 118 | Main Kitchen |
| 119 | Providing and fixing following stainless steel kitchen/wardrobe over the counter /under the counteraccessories of Kaff/Hettich make or other equivalent approved brand including necessory channels, screw etc complete in all respect required to comlete the modular kitchen ALL drawers shall be of type tandem / innotech hettich unless otherwise specified. |
| 120 | Dish Drainer set Hettich (CAT. no. 9206161 ) |
| 121 | Pipe with fittings Kaff K1OS 602 |
| 122 | Suspension S typehooks - ( Kaff) |
| 123 | Cuttlery Basket Hettich ( OrgaTray 560 adjustable partition )9005671 |
| 124 | Pullout trolley Hettich (Cat no. 9190406 ) |
| 125 | Pull out multipurpose basket Hettich (cat no. 9235979) |
| 126 | Pull out multipurpose basket Hettich (cat no. 9235979) |
| 127 | Pull out large utensil Basket Hettich ( Cat No. 9194322) |
| 128 | DOOR /WINDOWS/ DRAPERY |
| 129 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length to secure the frame to wall complete as per directions |
| 130 | Second class teak wood |
| 131 | Providing and fixing Teak Wood architrave to chowkhat and wall / partition of finished size 37mm x 19mm, moulded to shape. All complete as per specifications, drawings, design intent and instructions of the Architect. |
| 132 | Providing and fixing moulded teakwood frames of doors, and other frames of sizes 175 x 65mm as per design.All complete as per specifications, drawings, design intent and instructions of the Architect.Wood to be polished in Polyurethane clear transparent high gloss ref. ICA cat. LP5771 |
| 133 | Removing , Resizing and refing the existingwood frames of doors, and other frames of all sizes and shapesas per specifications, drawings, design intent and instructions of the Architect.Wood to be polished in Polyurethane clear transparent high gloss ref. ICA cat. LP5771 |
| 134 | Providing and fixing teakwood architrave to chowkhat and wall / partition of finished size 37mm x 19mm, moulded to shape. All complete as per specifications, drawings, design intent and instructions of the Architect. |
| 135 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood . Shutter Size Upto 1050 X 2400 Item includes all edges of shutter to besealed with6 mm thick Teak wood /Wenge wood edging slip on all sides. Wood protected with two coats sealer and two coats of melamine (matte) polish. |
| 136 | 35 mm thick including ISI marked Stainless Steel butt hinges 4 Noswith necessary screws. |
| 137 | Refurbishing existing furnitures |
| 138 | Refurbishing the existing fully upholstered with new Fabric/Leatherite Inclusive ofback, cushion of with upholstered with fabric /leatherite of approved shade & texture.Thecomplete sofa is covered with upto 1\" thk new Polyurethane foam having density =45+/-2 Kg/cm3 and hardness of the P.U. foam = 12 to 22 Kg on Hampden m/c for 25% compression of the foam on existing foam retaining contours.FABRIC/Leatherite( Upto Rs 300 pm )shall be stain repellent fabric. ( Drg No Fur/01/Sofa |
| 139 | Single Seater |
| 140 | Three Seater |
| 141 | Refurbishing the existing Dining Chair made out ofwooden legs with HardInclusive ofremoving the existing fabric and foamand providing new Polyutherene foam,cushion on front , back and on seat top upholstered with fabric/leatherite of approved shade & texture. Two or more coats of french spirit polishing including a coat of wood filler shall be done on all exposed visible wood and vineer surfaceComplete as \"directed. (Basic cost of fabric Rs 250/- mt.) as per directions.The polyurethane foam is moulded with density = 45 +/-2 kg/m and Hardness = 20 +/- 2 on Hampden machine at 25% compression. |
| 142 | Removing, resizing and refining the existing glasses of all thickness and sizes complete as per directions |
| 143 | P/F 5.5 mm thick glass panes |
| 144 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : |
| 145 | 250x10 mm |
| 146 | 150x10 mm |
| 147 | 100x10 mm |
| 148 | Providing and Fixing following types of of Dorset equivalent approvedhandles /locks etc system complete in all respect |
| 149 | Cylider lock Euro Profile Cylindrical lock with both side keys with mortice lock model No ML100 anda pair of lever handles ( Madonna ) ( Patina finish) with Rose |
| 150 | Cylider lock Euro Profile Cylindrical lock with one side key and one side knob with mortice lock model No ML100 anda pair of lever handles ( Madonna ) ( Patina finish) with Rose |
| 151 | Cylider lock Euro Profile Cylindrical lock with one side knob with mortice lock model No ML100 anda pair of lever handles ( Madonna ) ( Patina finish) with Rose |
| 152 | Cylider lock Euro Profile model no CL-207 with mortice lock model No ML100 anda pair of lever handles (ever handles ( Madonna ) ( Patina finish) with Rose |
| 153 | Providing and fixing powder coated extruded aluminium track using C channel with hard drawncord system with runners with ball bearing and all accessories incuding Brackets etc ( model Vista- Super Track ) |
| 154 | Providing and fixing Curtains in approved fabric and in approved stitch pattern on the track ( length in Mtrs of fabricused for making the curtain shall be considered making the payment ) |
| 155 | Fabric of basic priceupto Rs 250 / Per Mtr |
| 156 | Fabric of basic price upto Rs 750/ Per Mtr |
| 157 | Providing and fixing M.S. grills of required pattern in frames of door/ windows and walletc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 158 | Fixed to steel windows by welding. |
| 159 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 160 | PAINTING AND POLISHING |
| 161 | Providing and applying POP Punning on walls and columns (average 8mm thk). The rate shall include scrapping, levelling and preparing the surface. The rate shall be inclusive of all types of grooves above the skirting, around the window and door frames. |
| 162 | Wall painting with plastic emulsion paint including coad of primer ( roller finish ) of approved brand and manufacture to give an even shade |
| 163 | Two or more coats on old work |
| 164 | Two or more coats on new work |
| 165 | Extra on 6.2bbut with Asian Royale plastic emulsion paintin approved shade other than metallic shadeon walls . |
| 166 | French spirit polishing : |
| 167 | Two or more coats on old work sqm |
| 168 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: |
| 169 | One or more coats on old work. |
| 170 | Two or more coats on new work over an under coat of |
| 171 | suitable shade with ordinary paint of approved brand and |
| 172 | manufacturer |
| 173 | P/A Matt spray PU paint including all subsurface preparation . Suggested Brand : MRF. |
| 174 | SANITARY ,WATER SUPPLYAND PLUMBING |
| 175 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead |
| 176 | 75 to 80 mm diametre C.I. Pipe |
| 177 | 100 mm diametre C.I. Pipe |
| 178 | Dismanting old G.I. Pipes ( internal works) wherever required including cutting the walls |
| 179 | 15 mm to 40mm diameter G.I. Pipe |
| 180 | Providing and fixing following Sanitary fixtures |
| 181 | Providing and fixing table top type vitreous chinawash basin of590x440X135 mm sizefor with specially fabricatedbrackets/bolts, painted white, 32mm C.P.waste, 32mm dia cast brass bottletrap andconnection pipeto wall with C.P. wall flange andrubber adopter for waste connection, complete including cutting and making good thewalls, wherever required.(MODEL NO - JDS-WHT -25931 JAQUAR MAKE or approved equivalent) |
| 182 | Providing and fixing followingC.P.Brass fittings/ bathroom accessoriesincluding all nuts and washers,CP flanges etc including cutting and making good the walls wherever required |
| 183 | Providing & fixing C.P single leaver divertor concieled body jaquar ALD-079 or approved equivalent) for bath & shower system, including cutting and making good the walls, wherever required. |
| 184 | Providing & fixing C.P single leaver divertor exposed body jaquar VGP-81079k or approved equivalent) for bath & shower system. |
| 185 | Providing and fixing CP brass angular Stop Cockof jaguar VGP-81053 or equivalent approved model |
| 186 | Providing and fixing Dual _Flush Face Plates for Conceiled Cistern Jaquar/Kohler or equivalent approved model Base Price Rs 2500/- |
| 187 | Providing and fixing Health faucet in PVC Flexible Tube with wall hook (jaguar-ALD -CHR-593N or approved equivalent) |
| 188 | Soil,Waste and Vent Pipes |
| 189 | Providing and fixing soil, waste and vent pipes |
| 190 | 100mm dia |
| 191 | Centrifugally cast (spun) iron S & S pipe as per IS:3989 |
| 192 | Providing and fixing plain bend of required degree |
| 193 | 100mm |
| 194 | Centrifugally cast (spun) iron S & S. as per IS 3989 |
| 195 | Internal Water Supply |
| 196 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Project Manager |
| 197 | Concealed work, including cutting chases and making good the |
| 198 | walls etc. |
| 199 | 15mm nominal outer dia, CTS pipe (15.90mm OD) |
| 200 | 20mm nominal outer dia, CTS pipe (22.20mm OD) |
| 201 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : |
| 202 | 15 mm dia nominal bore |
| 203 | 20mm dia nominal bore |
| 204 | ELECTRICAL works including FITTINGS, FIXTURES & APPLIANCES |
| 205 | DISTRIBUTION BOARDS : |
| 206 | Supplying, receiving, storing, handling, erecting, testing and commissioning of Single Pole and Neutral MCB distribution board, IP 43 protection, sheet steel, double door, powder coated, 240 volts, in recess/surface, complete with 100 amp tinnedcopper bus bar, neutral bar, earth bar, top and bottom removable gland plates with knockouts, interconnections, earthing etc. as required. DB\"s shall be original factory fabricated of approved make. |
| 207 | Make : Legrand-Lexic / L&T / Hager / ABB / Schneider-Acti 9 |
| 208 | 16 WAYS SPN |
| 209 | Supplying, fixing, connecting, testing and commissioning of followingrating, ISI marked (IS 8828) 240 / 415 volts, 10 KA, Miniature Circuit Breaker (MCB)of single / double / three / four poles in the existing MCB DB or in existing MS enclosure complete in all respects. |
| 210 | Make : Legrand-Lexic / L&T / Hager / ABB / Schneider-Acti 9 |
| 211 | 5 to 32 Amp. SP MCB |
| 212 | 5 to 32 Amp. DP MCB |
| 213 | 40 Amp.DP MCB |
| 214 | 50/63 Amp. DP MCB |
| 215 | 32 Amp.FP MCB |
| 216 | 40 Amp.FP MCB |
| 217 | 50/63 Amp. FP MCB |
| 218 | WIRING : |
| 219 | Supply all materials, receiving, storing, handling, fixing, laying, wiring and testing for light, fan, exhaust fan, 5 Amp. switch and socket, etc starting from point control box to the outlet using ISI marked (IS:694) single core 1.5 sqmm flexible, flame retardant low smoke (FRLS), stranded copper conductors PVC insulated 1100 Volt grade wiring in concealed / exposed system using 25 mm ISI marked (IS:IS:9537-III & 3419) 2 mm thick, heavy duty PVC conduit including all conduit accessories, such as bends, tees, draw boxes, minimum 1.2 mm thick G.I. or MS point control boxes with zinc plating and yellow passivation, together with wiring accessories such aswhite modular plate type switches and sockets,cover plate, grid plate etc. including circuit wiring from DB to switch board and switch board to switch board by 2x1.5 sq.mm. flexible flame retardantcopper wire with 1.5 sqmm Cu earth continuity wire. |
| 220 | The conduit being laid in recess (concealed) either in ceiling slab / wall, chasing on surface or under false ceiling including required clamping arrangement and required length of PVC flexible conduit orin wooden partitions etc. complete as required at site.(The minimum size of conduit will be 25 mm dia irrespective of number of wires drawn into it) |
| 221 | One light point with 5 Amp.switch. |
| 222 | Each additional light point controlled by same 5 amp switch |
| 223 | call bell push. |
| 224 | Exhaust fan and wall bracket fan point with 5 Amp.Switch |
| 225 | One 5 pin 5 amp shuttered socket outlet with 5 amp switch |
| 226 | Set of two 5 pin 5 amp shuttered socket outlet with 1 no. 5 amp switch. |
| 227 | Blank plate for modular plate type switch boards wherever required. |
| 228 | Supply all materials, receiving, storing, handling, fixing, laying, wiring and testing for power outlets using ISI marked (IS:694) single core, flexible, flame retardant low smoke (FRLS), stranded copper conductors PVC insulated 1100 Volt grade wiring in concealed/ exposed system using 20 mm/25 mm ISI marked heavy duty PVC conduit (IS:IS:9537-III & 3419) including all conduit accessories, such as bends, tees, draw boxes, minimum 1.2 mm thick G.I. or MS point control boxes with zinc plating and yellow passivation, together with wiring accessories such aswhite modular plate type switches and sockets,cover plate, grid plate etc. including submain wiring from DB to outlet with Cu earth continuity wire, conduit being laid in recess (concealed) either in ceiling slab / wall, chasing on surface or under false ceiling including required clamping arrangement and required length of PVC flexible conduit orin wooden partitions etc. complete as required at site. |
| 229 | One 6 pin 15 amp shuttered socket outlet with 15 amp switch by 2x4 + 2.5 sq mm copper wires. (Primary Power) |
| 230 | 32 amp TPN industrial metal clad outlet in MS box with 32 amp C series FP MCB and metal plug top instead of modular switch & sockets by 4x6 + 4 sq mm copper wires. |
| 231 | SUBMAINS/MV CABLES |
| 232 | Providing and laying of PVC insulated copper conductor/Cable 1100 volt grade stranded flexible FRLS Wire in required size of pvc heavy duty conduit. |
| 233 | 2 x 16 + 1 x 4 sq.mm PVC insulated stranded flexible copper wires inpvc conduit |
| 234 | 4 x 16 + 2 x 6 sq.mm PVC insulated stranded flexible copper wires inpvc conduit |
| 235 | LIGHTING FIXTURES: |
| 236 | Supply ,Assembling, installation, testing & commissioning of following type of light fixtures and fans. Allfixtures shall be provided with power factor improvement capacitors, electronic control gear & lamps as per requirements and installation arrangement using proper support etc. complete as required. |
| 237 | HAVELLSwall bracket 1 NX9W LED Lamp LHFOAJE1TZ1I060 |
| 238 | HAVELLSwall bracket 2 NX9W LED Lamp LHFOAJE2TZ1I060 |
| 239 | HAVELLSPendant ( Fusion Pandant ), 1LS E27 D320 RED ( or CRE/GRY ) |
| 240 | HAVELLS Trim Round Surface accessories |
| 241 | Surface Module Trim Plus 6 W ,LSSLNW0129 |
| 242 | Surface Module Trim Plus 9W ,LSSLNW0131 |
| 243 | Surface Module Trim Plus18W ,LSSLNW0133 |
| 244 | HAVELLSClipon LED Panel Round |
| 245 | Surface Mounted clipon light 6 W LED 4000 K, LHEAABP6IL1E006 |
| 246 | Surface Mounted clipon light 12 W LED 4000 K, LHEAABP6IL1E0012 |
| 247 | Surface Mounted clipon light 18 W LED 3000 K, LHEAABP5IL1E0018 |
| 248 | HAVELLS recessed down light 3 W LED 3000 K LHEEAQPBIB1W003 ( Crysta Neo COB Swivel) |
| 249 | HAVELLS recessed down light 6 W LED 6500 K LHEEAQPFIB1W006( Crysta Neo COB Swivel) |
| 250 | HAVELLS recessed down light12W LED 6500 K LHEEAQPFIB1W012( Crysta Neo COB Swivel) |
| 251 | HAVELLS recessed down light 3 W LED 3000 K LHEBADP5IZ1W003 |
| 252 | HAVELLS recessed down light 6 W LED 6500 KLHEBADP7IZ1W006 |
| 253 | HAVELLS recessed down light 12 W LED 6500 KLHEBADP7IZ1W0012 |
| 254 | HAVELLSMirror lightLED Batten 20 W 4000 K , LHLDESAARANB020 |
| 255 | HAVELLS LED Pride Plus Neo Batten 40 W 6500 K Alluminium Batten, LHEXACP7IN1J040 |
| 256 | Providing, installing, testing and commissioning of pre-wired Flexible LED Strip ,HAVELLS, 24Ww 4000 K5m,LHEHDLP6UN1W024 |
| 257 | Providing, installing, testing and commissioning of Driver for LED STRIP12 V 2 A Driver, LSSLNW0150/LHFXBGNNIN1W024 |
| 258 | APPLIANCES |
| 259 | Providing, Fixing/Installing andTesting the following appliances complete in all respect including necessary accessories etc |
| 260 | Sony BRAVIA 80 cm (32 inches) HD Ready Smart LED Google TV, KD-32W835 includingpower cord, Batteries, Remote Control, TV standsfor Table as well as for wall mounting |
| 261 | Sony 164 cm (65 Inch) 4K Ultra HD LED Google TV - 4K Processor X1 Processor, Chromecast Built-in, Voice Search, HDR10/HLG, K65S25includingpower cord, Batteries, Remote Control, TV standsfor Table as well as for wall mounting |
| 262 | 8 Kg Semi Automatic 5 star rating , Top Loading Washing Machine Model WT80C4200GG/TL Samsung |
| 263 | 90 CM WallMounted Electric Hood ( Chimney) . 1500M3/Hr Suction,Heat Auto Clean , model ALPINE FL HC BK 90 -SKU: 330.0717.200 including providing fixing compatible PVC pipe upto 4.0 Long pipe |
| 264 | Counter topfour burner stove ( hob) 720x500x80 mm iwith manual ignitionmodel FaberHOB COOKTOP PRINCE PLUS 4BB BK ( SKU : 106 .0689.181 |
| 265 | RO water dispenserwith Filteration Capcity 20L/Hr and 9 litre storage capacity . Model KENT Grand Plus 9L RO +UV+UV-in -tank +TDS Water purifierwithZero Water Wastage |
| 266 | 32 litres Microwave with Touch Controls, Interior Ceramic Enameledmodel Samsung 32L Convection Microwave Oven with Slim Fry Technology |
| 267 | Toaster Pop up type including Bun Warmermodel PHILIPS HD2582/90 |
| 268 | 301 litres Frost Free Double Door 2 star Convertiblefridge ( Refrigerator ) Model Samsung Elegant RT34C4522S8/HL |
| 269 | 15 litres 5 Star ratingGeyser with Temp sensing LED Knob /Anti rust tank includingshock safe plug & Flexi Pipe Model Havels -Horizontal Storage |
| 270 | AIR CONDITIONING |
| 271 | NOTE |
| 272 | All items of work under this Contract shall be executed strictly to fulfill the requirements laid down under “Basis of Design” in the specifications.Type of equipment, material specification, methods of installation and testing and type of control shall be in accordance with the specifications, approved shop drawings and the relevant Indian Standards, however capacity of each component and their quantities shall be such as to fulfill the above mentioned requirement. |
| 273 | The unit rate for all equipment or materials shall include cost in RUPEES for equipment and materials including all taxes and duties and also including forwarding, freight, insurance and transport into Contractor’s store at site, storage, installation, testing, balancing, commissioning and other works as required. |
| 274 | The rate for each item of work included in the Bill of Quantities shall unless expressly stated otherwise, shall include cost of: |
| 275 | · All materials, fixing materials, accessories, appliances, tools, plants, equipment, transport, labour and incidentals required in preparation for and in the full and entire execution, testing, balancing, commissioning and completion of workas per BOQ, Specifications and Drawings. |
| 276 | · Wastage on materials and labour. |
| 277 | · Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in position, protecting, disposal of debris and all other labour necessary for the full and entire execution. |
| 278 | · Liabilities, obligations and risks arising out of Conditions of Contract. |
| 279 | · All requirements of Specifications, whether such requirements are mentioned in the item or not.The Specifications and Drawings where available, are to be read as complimentary to and part of the Bill of Quantities and any work called for in one shall be taken as required for all. |
| 280 | · In the event of conflict between Bill of Items and other documents including the Specifications, the most stringent shall apply.The interpretation of the Architect / Employer shall be final and binding. |
| 281 | This Schedule shall be fully priced |
| 282 | No alteration whatsoever is to be made to the text or quantities of this Schedule unless such alteration is authorized in writing by the Architect / Employer.Any such alterations, notes or additions shallunless authorized in writingbe disregarded when tender documents are considered. |
| 283 | In the event of an error occurring in the amount of the Schedule as a result of wrong extension of the unit rate and quantity, the unit rate quoted by the bidder shall be regarded as firm and the extensions shall be amended on the basis of rates. |
| 284 | The Contractor shall procure and bring Material/Equipment to the site only on the basis of drawings approved for construction and shop drawings and not on the basis of Bill of Quantities, which are approximate only.This also applies to the Contractor’s requisition for Employer supplied materials. |
| 285 | All Control cabling & wiring required to make the system complete shall be treated as part of equipment, panels etc. and nothing extra shall be payable on this account. |
| 286 | Rmt shall mean distance between the indoor and outdoor unit measured along the route of refrigerant piping irrespective of number of refrigerant circuits |
| 287 | Supply , Installation, Testing and Commissioning of Hot and Cold inverter type Split Units comprising of: |
| 288 | 1 x Indoor Unit ofNominal Capacity as shown below complete |
| 289 | 1 x Out Unit |
| 290 | Hi wall split /Casette type Hot and Cold inverter type splitAC shall be energy efficient of BEE Label 3 Star rating |
| 291 | Standard Installation of above split AC units including fixing copper refrigerant piping with fittings, nitrile rubber insulation & wiringfor each compressor to interconnect the condensing units with the indoor units including gas charging, testing & commissioning ( copper refrigerant piping ,insulation and wiring shall be paid extra ) |
| 292 | Initial charge of refrigerant and oil. |
| 293 | Electronic remote control unit |
| 294 | Refrigerant: R-32 / manufacturer recommeneded |
| 295 | MS Angle Iron Stands and vibration isolation for mounting the outdoor units. The stands shall be painted with 2 coats of red oxide primer and 2 coats of synthetic enamel paint. |
| 296 | Power Supply: Single Point Power Supply within 1 metre of outdoor unit, Single Phase, 50 Hz, 3 wire |
| 297 | Cost shall be inclusive of minor masonary work e.g. making openings in walls and slabs for passing pipes,cables, etc. and finally sealing and finishing them good. ( SpecifiedMake :- DIAKEN/HITACHI/TOSHIBA/LG) |
| 298 | Capacity 1.5 TR ( High Wall SplitAirconditioner) |
| 299 | Supply and fixingcopper refrigerant piping with fittings, nitrile rubber insulation & wiring to interconnect the condensing units with the indoor units including gas charging, testing & commissioning.Rmt shall mean distance between the indoor unit and outdoor unit measured along the route of the refrigerant piping irrespective of number of refrigeration circuits. Specifiedmake RAJCO |
| 300 | For 1.5 TR Hi Wall splits |
| 301 | DRAIN PIPING |
| 302 | Charges for providing additional 25mm dia heavy duty PVC drain piping with all necessary fittings duly insulated with 9mm thick nitrile rubber pipe insulation drain pipe concealed / surface mounted and taken through wall / partition beyond the standard 5m length for the above split units. |
| 303 | STABILIZERS |
| 304 | Supply, installation, testing and commissioning of wall mounting 4KVA stabilizers for 1.5Tr& 1.0Tr Hi-Wall SplitAir Conditioning units with input voltage range of 170-270 Volts and output 220 +/- 10% as required.Specifed Model V Guard |
| 305 | Electrical Cable :- |
| 306 | Providing & fixing of 2.5 Sqmm wiringinterconected electrical indoor & outdoor unit as required complete as per design &wiring between specification of manufacturer. |
| 307 | Total of above Cost Carried over to Summary |
| 308 | BUYBACK |
| 309 | Buy Bock of FollowingDismantled and Stacked Materials on Lump Sum and as is where isBasis including removing the same from site complete in all respect as per direction |
| 310 | CP fittings including dismantling the same |
| 311 | Unservicable wooden items |
| 312 | Cables and Wires, light fixtures including dismantling the same |
| 313 | Existing indoor and out door AC units including dismantling the same |
| 314 | Indoor high wall split units |
| 315 | Outdoor units |
| 316 | Existing TV units |
| 317 | Existing Geysers |
| 318 | Fridge |
| 319 | Total For BUY BACK carried over toSummary of Cost |
| 320 | SUMMARY OF BID |
| 321 | Total Bid Cost (A) |
| 322 | Total Buy Back (B) |
| 323 | NET PRICE BID (Total Bid Cost (A)-Total Buy Back (B)) |
| 324 | NET PRICE BID AMOUNT IN WORDS : |
| 325 | (RUPEES ….................................................................................... ONLY) |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail