| Sl. No. | Item Description |
| 1 | Demolition brick or stone masonary built in cement mortar including all quoins arches pillars etc but excluding ashlars facing dressed stone work and precast concrete block, complete all as specified |
| 2 | M & L for brickworks with sub class \"B\" bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified. |
| 3 | Taking down cement or cement lime plaster on brick or stone walls , etc including raking out joints, hacking for key, scrubbing down with eater etc,complete all as specified. |
| 4 | M&L for rendering 15 mm thick with liquid water proofing compound on other than fair faces of brick work or concrete surfaces finished even and smooth in cement mortar 1:4, complete all as specified |
| 5 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfacein CM 1:6 finished even & smooth without using extra cement complete all as specified & directed by Engineer-in-Charge. |
| 6 | M&L for 5mm thick rendering in cement mortar in 1:3 to concrete surfaces as in ceilingin patches, finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-Charge. |
| 7 | M&L for two coats of cement base paint on newplasteredsurfaces of walls including prepration of surfaces and priming with alkali resistant priming paint complete all as specified & directed by Engineer-in-Charge. |
| 8 | M&L for two coats of oil bound distemperon newplasteredsurfaces of walls including 1 mm thick wall putty on plastered wall surface incl prepration of surfaces and priming with alkali resistant priming paint complete all as specified & directed by Engineer-in-Charge. |
| 9 | M&L two coats of white wash to new plastered surfaces on ceiling including preparation of surfaces complete all as specified & directed by Engineer-in-Charge. |
| 10 | Dismantlingof stone slabs and tilesof any description or thickness in floors aprons laid and bedded and jointed in cement mortar complete all as specified and as directed. |
| 11 | M&L for Marble work green marble 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with green marble shade complete all as specified. |
| 12 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations |
| 13 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 14 | M&L for Non-skid coloured Ceramic tiles 7to 8 mm th. (square/ rectangular) area of each tile exceeding0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe coloured tiles over and including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified. |
| 15 | M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to over & including 10mm thick screed bedin 15mm thick Screed bedin CM 1:6 for laying floor finishes complete all as specified and as directed. |
| 16 | All as per item No. 15 above but on skirting over 8 to 10 mm thick in CM 1:4 complete all as specified. |
| 17 | M&L for Vitrified Ceramic tiles of light colour shade 8 to 10 mm thick (square/rectangular) polished, area of each tileexceed 0.30 sqm, but not exc 0.42 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match,over and including 15 mm thick screed bed or bedding layer of cement mortar 1:6, complete all as specified and directed. |
| 18 | All as per item No 17 above but for for skirting over 10mm thk rendering in CM 1:4 complete all as specified and as directed. |
| 19 | M&L for glazed coloured ceramic tiles350 mm x 250mm/450mmx350x7 to 8 mm thick as in vertical surfces set & jointed in neat cement slurry & pointed in coloured cement with & including backing coat 10mm thick in CM 1:4complete all as specified and directed. |
| 20 | Taking down chowkhats orframe with shutter (without taking off shutter from the frames) & removing from siteexc. 1.5 Sqm but n. exc 4Sqmeach complete all as specified and as directed |
| 21 | Taking down chowkhats orwith shutter (without taking off shutter from the frames) & removing from site n exc. 1.5 Sqm each complete all as specified and as directed |
| 22 | Taking down shutters of any description exc 1 sq. m and n exc 2 sq. m eachcomplete all as specified and as directed |
| 23 | Taking down re-fixing Shutters of any description but exc 1 sq. m and n exc 2 sq. m each in same opening including easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc. Renewal of builder\"s hardware articles, if specially ordered, shall be paid for at \"supplied only\" rates. |
| 24 | S&Ffor pressed steel door frames with one or more rebates incl necessary fixing lugs, hinges, lock strike plates of size 125 X 60mm |
| 25 | S&Ffor pressed steel door frames with one or more rebates incl necessary fixing lugs, hinges, lock strike plates of size 165 X 60mm |
| 26 | M&L for providing PCC 1:3:6, type C-0 (using 12.50 mm graded stone aggregate) as in filling of pressed steel door frame and holdfasts including necessary formwork etc. |
| 27 | S&F factory made 35 mm thick plain framed paneled shutter (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with Commercial veneered on both faces the size of rail and style as per IS-1003 ( Pt-I) kiln seasoned and Chemically pressed of 2nd class hard wood. |
| 28 | S & F factory made 35 mm thick glazed & skeleton shutter of 2nd class hard wood open rebated and prepared to receive gauge(divided into squares with sash bars) edges of framing plain chamfered or rounded, fitted without & fitted beads for securing glass etc, sizes of members of shuttersas specified in SSR Pt-I Sec-8 clause 8.23 (a) and fitted to chowkhats complete all as specified. |
| 29 | Supply & Fixing PVC door frame (50x47) mm made out of plain colour5 mm thich PVC Sheet reinforced with MS Square Tube, supplying & fixing in opening as per specification & drawing |
| 30 | Supply and fixing Factory made solid panel PVC door shutter 30 mm thick ( Style ) consisting of frame made out of MS Tubes for top & bottom rails.MS frame shall be covered with heat moulded plain colour PVC \" C \"Channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC Sheets for top rail , lock rail & bottomrail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC Sheet to be fitted in the MS Frame welded / sealed to stiles & rails with suitable PVC Sheet beading, jointed together with solvent cement,supplying & fixing in the frame at site as per specification & drawing. |
| 31 | Supply and fixing three track sliding window including frame with two shutters with 4mm thick tinted glass and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18 mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc; fabricated using following aluminium anodised sections conforming to catalogue of \"JINDAL\" or of equivalent make complete all as specified and directed by Engineer-in-Charge.(a) Bottom frame - 20620(b) Top frame & vertical - 20621(c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844(f) Glazing clips - 19352. (Note:- Cost of Tinted glass & wire cloth shall be included in the quoted rate of the item). |
| 32 | S & F Aluminium powder coted decogrill 7.5mm width and 6mm thk of design DG 102 having weight 3.131kg/Sqm fixed to and including powder coated aluminium U type frame with CP brass/SS screws @ 200 c/c, including cutting the grill to proper opening size for fixing and operation of handle and fixing powder coated aluminium section around the opening all as per requirement and direction of Engr-in-Charge |
| 33 | S&F 100 mm Butt hinges, stainless steel with mild steel hinge pin, bright polished and fixed, typeB-11 ccomplete all as specified anddirected. |
| 34 | S&F 250 mm Aluminum alloy, anodised , sliding door bolt with hasp and staple (BOLT TYPE) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed. |
| 35 | S&F 150mm long Aluminium anodized, barrel tower bolt of extruded section. |
| 36 | S&F 100mm long Aluminium anodized, barrel tower bolt of extruded section. |
| 37 | S&F150mm longAluminium handles cast type anodised |
| 38 | S&Fin repair 150mm longAluminium handles cast type anodised |
| 39 | S&F in repair aluminium( Extruded section) body door closer hydraulically regulated , designation No. 3 universal type , suitable for door shutterof 851 to 1000mm in width complete all as specified and directed. Make : Dyna and equivalent ISI marked |
| 40 | S&F 150 mm long mortice latch with two levers(vertical type), mild steel body complete all as specified and directed. |
| 41 | S & F radiant door bottom sealing strip guard for doors complete all as all as specified and directed. |
| 42 | S&F in repairs 25 mm dia Stianless steel curtain rod with side knobs and fancy type brackets of stainless steel of 25mm dia in pair of required size all as specified and directed. |
| 43 | S & Fin repair galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples to wooden/steel shutters all as directed. |
| 44 | S & FStainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 45 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones |
| 46 | S& F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane |
| 47 | M&L Fixing of nozals @ 1mtr c/c on structural members using suitable drill machine at least 75mm in depth and ceiling the nozals with eposy putty. Injecting materials epoxy injection grouts-two components low viscous high strength (7days comp strength 800kg per cmsqm) epoxy resin based injection grout meets the requirement of BS 6319 and ASTMC 881. Crack injection material should be injected using standard injection pump having closed containers and removing the drilled nozals and sealing with epoxy putty upon completion of injection work. |
| 48 | S&Ffloor door stopper, with 150 mm longof brass body and tounge with hard drawn steel spring in floor complete. |
| 49 | S&F in repairHarrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. all as specified and directed. |
| 50 | Dismantling water tanks and removing to store of capacity exc. 250 litres & n.exc 500 litres. |
| 51 | Dismantling water tanks and removing to store of capacity exc. 500 litres & n.exc 1000 litres. |
| 52 | S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe spouts for connecting inlet, outlet, over flow and washout pipes all as specified and as directed. |
| 53 | S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe spouts for connecting inlet, outlet, over flow and washout pipes all as specified and as directed. |
| 54 | S & F in repairsball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore and fixed (minimum weight 210 gms) complete all as specified and as directed. |
| 55 | S & F in repairs 15 mm dia stop valves cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or union fixed in repair for 15 mm dia GI pipe all as specified and as directed. |
| 56 | S & F in repair 15 mm dia bore fancy type chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 57 | S&F in repair 15 mm dia bore pillar taps ,cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixedcomplete all as specified and directed. |
| 58 | S&F in repair 20 mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe andcomplete all as specified and directed. |
| 59 | supply only 15mm bore PTMT Bib taps standard any colour screwed down for iron pipe and fixed minimum weight 90 gm complete all as specified and directed. Make: Prayag & equivalent. |
| 60 | supply only PTMT waste coupling of 32 mm dia (half or full thread) including taking down old coupling of any description complete all as specified and directed. |
| 61 | supply only 32 mm dia flexible waste pipe for wash basin and kitchen sink complete all as specified and directed. |
| 62 | S&F in repair 20 mm dia D type CP towel rail 600 mm long between flanges complete all as specified and directed. |
| 63 | S&F in repair Health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified and as directed by Engineer-in-Charge |
| 64 | S&F in repairs chromium plated shower rose with swivel joints including fixing to GI pipe for 125mm dia |
| 65 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long all as specified and directed. |
| 66 | S&F in repair vitreous china squatting pan ORRISA PATTERN size 580x440mm white with integral foot rests excluding flushing cistem & fush pipe fixed in repairs complete all as specified and as directed. |
| 67 | S&F in repairs vitreous china wash down water closet pan (pedestal pattern)white with \"P\" or \"S\" trapincluding connection to drains (or outgoing pipes) and to the flushing pipes, complete all as specified and directed. |
| 68 | S & F as in repair Plastic water closet seat cover ,closed pattern with recessed bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 69 | S&F in repair Vitreous China Urinal, Half stall type(back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plug with and including 60mm long brass screws, pointing around urinal back in cement including urinal spreader of PTMT any colour for fixing with 15mm dia pipe, PVC connection 15mm x 600mm long, waste coupling of PTMT (Half or full threaded) 40mm dia |
| 70 | S & F in repair 100mm dia steel chromium plated gratings fixed on floor trap/Nahani trap in cement mortar 1:4 complete all as specified and directed. |
| 71 | S & F in repairs for PVC connection pipe 15mm dia with PTMT nuts of length 450mm complete all as specified and as directed. |
| 72 | S/F in repairs Vitreous china wash basin white flat back size 550 x 400mm including , waste pipe and plug and porcelain stopper and brackets incl cutting for and pinning in ends of brackets or erecting stand along with 32mm dia CP waste coupling and PVC waste pipe complete all as directed. |
| 73 | S&F as in repairsPVC low/highlevel flushing cristern white 10 litre capacity incl PVC inlet pipe with brass check low level full both sides alongwith PVC flush pipe 32mm dia jointed to WC and handle incl brackets all as directed. |
| 74 | Cleaning and removing all scale and dirt etc. from tanks and from mouths of circulating pipes etc. from existing water tanks of capacity upto 500 litres of any type and in any position and writing the date of cleaning complete all as specified and directed. |
| 75 | Cleaning and removing all scale and dirt etc. from tanks and from mouths of circulating pipes etc. from existing water tanks of capacity exc. 500 litres and not exc. 1000 litres of any type and in any positionand writing the date of cleaning complete all as specified and directed. |
| 76 | Demolition ofconcrete ( un reinforced ) in ground floors and paving n.exc 15 cm thk (below or above ground level)complete all as specified and directed. |
| 77 | M & L for cement concrete Type C2 1:3:6(using 40mm graded aggregates) as in plinth protection 75 mm thick finished top surface even and smooth without using extra cement complete all as specified and as directed. |
| 78 | M & L cement conrete 1:7:12 type F2(uisng 40mm graded aggregate) as in sunkun filling complete all as specified and directed. |
| 79 | Providing and carrying out water proofing treatment to toilet ,sunken slabs ,wet areas etc,after proper surface prepration ,carry out cementitious ingection grouting at leakage point using Cebex 100 plasticised expanding grouting admixture ,application of polymer modified at slab wall junction using Nitoband SBR latex screed modifier cum bonding agent and application ot two coats of brushbond RFX two part acrylic polymer modified cementitious elastomeric waterproof and protective coating etc,complete including 15 mm thick cement plaster in CM 1:4 all tools and plants as per manufacturer\"s specification paint complete all as specified and directed. |
| 80 | M&L PCC 1:4:8 Type D2 40 mm aggregateas in foundations, filling and mass concrete |
| 81 | M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 82 | M & L for 75 mm thick PCC type D-2 1:4:8(40 mm graded aggregate) as in sub base for tiling complete all as specified and as directed |
| 83 | M& L Chequared Cement Concrete Tiles 30 CM x 30 CM X 25 mm th set and jointed in cement slurry and pointed in neatgrey cement&pigment in floors over screed bed 15 mm thk in cm 1:6 .complete all as specified. |
| 84 | M&L for laying machine pressed precast concrete rubber moulded interlocking reflective coloured (Glozy Finish) pavers block any shape and size confirming to IS 15658-2006 of 55mm to 60mm thick, M-35 Grade over 30mm thick sand layer watering and ramming all as specified. |
| 85 | All as per item No. 84 above but except tile and refixing of tile after retrieved from dismantling only |
| 86 | M&L PCC (20 mm graded aggregate)1:3:6 Type C1 Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges |
| 87 | M&L in repair for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe etc complete all as specified and directed. |
| 88 | M&L in repair for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe etc complete all as specified and directed |
| 89 | S&F PVC (SWR) bends ISI marked any radius of 110 mm borewithaccess door complete all as specified and directed. |
| 90 | S&F PVC (SWR) bends ISI marked any radius of 75 mm borewithaccess door complete all as specified and directed. |
| 91 | S&F in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 92 | Taking out existing water proofing treatment including cement plaster(any no of layers) on roof surfaces, cleaning the surfaces and removing the debris outside MOD land complete all as specified and as directed. |
| 93 | Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. specifically provided for complete all as specified and directed. |
| 94 | Disconnecting existing PVC water storage tanks of capacity exc 250 ltrs & n exc 500 ltrs, setting aside (or lowering if required) for laying of APP memberane or repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.complete all as specified and directed. |
| 95 | Disconnecting existing PVC water storage tanks of capacity exc 500 ltrs & n exc 1000 ltrs, setting aside (or lowering if required) for laying of APP memberane or repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.complete all as specified and directed. |
| 96 | M & L for providing 25 mm thick PCC 1:2:4 type B1 ( using 20mm graded stone aggregates ) as in filling in levelling course one roof slab complete all as specified and directed. |
| 97 | Extra over rendering for work in isolated width such as in bands, sunk pannels, cornices, skirting sides of slabs, parapet sides and top drip moulds etc and similar work not exc 15 cm width or girth complete all as specified and directed. |
| 98 | Supply only Liquid water proofing compound . |
| 99 | M/L for cleaning the plastered / concrete surfaces with wire brushes and applying water proofing treatment as under :-(a)Apply one coat of oil bituminous primer @ 1.20 kg/Sqmwith 10mm thk plaster in CM (1:6) .(b)Laying APP Polimerised modfied membrane not less than 3 mm thick and weighing not less than 3.0 kg per Sqm by torch applicaton method.(c)The overlap for APP membrane shall be 75 mm on longitudinal direction and 100 mm on transverse direction (d) Finally applying a coat of solar reflective bitumiious aluminium paint @ 0.15 Kg/Sqm over the membrane. |
| 100 | Taking up or down steel tubing and connections including cleaning for refixing of 15/20 mm bore of pipe complete all as specified and as directed. |
| 101 | Fixing only 15 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed. |
| 102 | Fixing only 20 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed. |
| 103 | M & L for 15 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed. |
| 104 | M & L for 20 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed. |
| 105 | Dismantling wall & ceilling boards(fibre pulp insulation etc) or insulation boards/ slabs/blankets, any thickness including cover fillets complete all as specified and as directed. |
| 106 | S & F 10-12 mm thick Gypsum board for ceiling, insulation and accoustic purpose 60x60cm in size fixed with screws with staples incl aluminium snap grid frame work 605x605 mm in flat/slopting ceiling with aluminium anodised grid work 35.60x23.60x1.60mm main Tee 23.60x23.60x1.60mm cross section and 26x26x1.60mm angle including 3mm dia GI wire suspender of suitable length aluminium cleats etc complete all as specified and directed. |
| 107 | Dismantling plain or corrugated steel sheeting any gauge, any thickness including Nainital orsimilar pattern roof covering , in wall clading and velley gutters complete all as specified and as directed by Engineer-in-Charge |
| 108 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed by Engineer-in-Charge |
| 109 | Dismantling timber scantlingin fillets,rafters,purlins etc. under 40 sqcm insection unframed work complete all as specified and as directed by Engineer-in-Charge. |
| 110 | Dismantling timber scantlings 40 sq. cm and over in section, in any position unframed work complete all as specified and as directed by Engineer-in-Charge. |
| 111 | Dismantling of wrought iron or mild / structural steel work any description and fixed in any position complete all as specified and as directed by Engineer-in-Charge. |
| 112 | S&F0.63 mm thickcorrugated galvanised mild steel sheets with two corrugation side lap fixed with L-type or J-type hooks with washers in roofs and wall etc with grade of zinc coating 275 including repair of roof sheeting work to carried out at any height including necessary scaffolding and safety measurescomplete all as specified and as directed by Engineer-in-Charge. (work will be done as patch work) |
| 113 | All as per item No 112 here in before but laid in curves of any radius as in roof all as specified and as directed by Engineer-in-Charge. |
| 114 | S&F Machine pressed in position valley gutters ( Trapezoidal section) made out of 1.00mm thick plain galvanised iron sheeting with gavanised coating 275gms/sqmincluding fabrication cut to size bending , denting or turning up angles as requred with plan 150mm laps jointing with brazing soldering as required to make the joints leak proof complete all as specified all as directed. |
| 115 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws completeall as per manufactures instructionswith all fittings and accessories etc complete all as specified and as directed by Engineer-in-Charge. |
| 116 | All as per item No. 115 above but with plain sheet fix in valley gutter / ridge complete all as specified and as directed by Engineer-in-Charge. |
| 117 | S&F framed works as in doors or gates of angles or other section with gusset plates, rails,braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with with and including either hooks and hinges or steel hanging door fitting and hanging also fastening and fixingconforming to Fe 410 Gde E-250 comlete all as specified and as directed by Engineer-in-Charge. |
| 118 | S&F in repair mild steel 1mm thick plain black sheet in wall claddding steel gates and similar works cut to size holes punched including round headed screws,clout nails or rivets and fixed to steel framming with plain 40mm lap joint with rivets or welded seams including bending or turning up,mitred angles etc complete all as specified and as directed by Engineer-in-Charge. |
| 119 | S&F roof trusses (framed),trussed,purlin,crane gantries,rails and fastening and heavy brackets framing (beam,tee,angles,channel or flat section including distances cleats etc conforming to Fe 410-W(Gde-E-250)complete all as specified and as directed by Engineer-in-Charge by Engr-in-charge. |
| 120 | S&F rolled sections as in main and cross beams,hip and jack rafters;purlins where connected to common rafters and running rails and guide for sliding doors;fixed with angle cleat or other connecting plates conforming to Fe 410 W Gde E-250 quality A complete all as specified and as directed by Engineer-in-Charge. |
| 121 | Excavating of soft/loose soilin post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,complete all as specified and as directed by Engineer-in-Charge |
| 122 | M&L PCC 1:3:6 Type D2 40 mm aggregateas in foundations, filling and mass concrete for post and others. |
| 123 | Dismantling fencing wire mesh , any tpe complete all as specified and directedby Engineer-in-Charge |
| 124 | Dismantling post, struts , (wood , steel or RCC any section incl. taking out embeded portion in concrete and making disturbed portiongood complete all as specified and as directed by Engineer-in-Charge. |
| 125 | Earth work in excavation all kind of soil by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 126 | S&F angle iron fencing post and struts including cutting tops to shape as directed, drilling holes, notching for wire etc , flat iron fillets ( for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-Charge. |
| 127 | S&F flat iron of size 40x6mm as in columns as in clamps, holdfasts wall ties etc conforing to Fe-290 Gde-165 complete. |
| 128 | S&F MS Screw bolts ( machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut length exc. 5 cm but not exc 10cm long 11 to 15mm dia of shank complete all as specified and as directed by Engineer-in-Charge. |
| 129 | Supply only chain link MS galvanised fencing incl line wire mesh (12 gauge) size and any type of strands, rails, straining bolts etc incle provn of binding wire complete all as specified and as directed by Engineer-in-Charge. |
| 130 | Fixing only chain link fencingany mesh, size and type to any type of standards, rails, straining bolts etc incl provn of binding wire complete all as specified and as directed by Engineer-in-Charge. |
| 131 | M&L for round bars 10mm dia and over cut to length bent to shape required incl cranking, bending spirally for hoping for columns, hooking ends and binding with and incl MS Wire (annealed) not less than 0.9mm dia or securing with clips conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-Charge. |
| 132 | S&F in repairs Galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs @ 75mm spacing and straining and fixing to any type of standard rail, straining bolts, inlc securing or tying at crossing with and provn of galvanised mild steel wire staples or steel pins etc. complete all as specified and as directed by Engineer-in-Charge. Note:- (Each line of wire to be measured.) |
| 133 | Welding in repairs exc 2.5 cm & n exc 5 cm in length & thickness of metal n.exc 6 mm all as specified and directed by Engr-in-charge |
| 134 | M&L for pre cast cement concre type B1, 1:2:4 (20mm graded stone agg) in landings, cover slabs (for man holes etc.)chullah hoods,chajjas, water troughs, mangers, shelves and similar articles with plain faces complete. |
| 135 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.all as specified and directed by Engr-in-Charge |
| 136 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soilall as specified and directed by Engr-in-Charge |
| 137 | Supply only12 Kg Boxof Dr. Fixit Fastflex high quality polymer modified flexible cementitious waterproofing membrane for water proofing. |
| 138 | M&L for damp stop (Berger/Birla/Asian paints/equivant) of 3mm thickon wall surface by using\"Roller\" after smoothningthe surface using sandpaper etc. complete all as specified and as directed.{Note: (a)Cracks of wall to be filled with its crack fill paste make berger or equivalent, (b) Damp proof should be done by skilled labour and as per manufacturer\"s instruction} |
| 139 | M & L for Preparation of old plastered surfaces of walls including washing, rubbing down and stopping of old surfacesurfaces applying twocoat of Cement base paint, complete all as specified. |
| 140 | M & L for Complete removal of existing treatment of surface finishon wall / ceiling (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped with wall care putty (3 mm thick) and applying one coat of primer with twocoat of oil bound distemper complete all as specified. |
| 141 | M&L 2 mm thick wall care putty on wall /ceiling complete all as specified and directed. |
| 142 | Material and labour for complete removal of existing treatment of plastered or unplastered old decorated surface walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. at any height of building / tower complete all as specified and as directed by Engineer-in-Charge. |
| 143 | M&L for preparation of new steel surface and applyingtwo coats of synthetic enamel paint over a coat of red oxide primer surfaces of any description exc 10 cm in witdth or girth complete all as specified and as directed by Engineer-in-Charge. |
| 144 | M & L for Preparing old painted steel & iron surfaces of any description over 10 cm in width or girth ,including roof and applying one coat of synthetic enamel paint of tint approved byEngr-in-charge complete all as specified. |
| 145 | M&L preparation of old steel surface of any description over 10 cm width or girthand applying one coat of red oxide primer completeall as specified and as directed by Engineer-in-Charge |
| 146 | M&L for preparation of new wooden surfaces and applying applying two coats of synthetic enamel paintover a coat of pink primer. |
| 147 | M & L for Preparing old painted surfaces of wood and wood based materials of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of tint approved byEngr-in-charge complete all as specified. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail