| Sl. No. | Item Description |
| 1 | Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, Foundation filling of poles or stays. |
| 2 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point. |
| 3 | Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required. |
| 4 | M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009)Note :Sand shall be fined sand as specified and punned thickness shall be measured and paid. |
| 5 | Supply and laying sub class \"B\" bricks of old size (230x115x75 mm) or of size locally available ,laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 6 | Laying only old bricks retrieved from item No.5 here-in-above of any size/type laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 7 | Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 16 Sq mm 2 core. Note: Earth work (Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule |
| 8 | All as per serial item No. 7 above but of size 16 Sqmm 4 core |
| 9 | All as per serial item No. 7 above but of size 25 Sqmm 4 core |
| 10 | All as per serial item No. 7 above but of size 35 Sqmm 3.5 core |
| 11 | All as per serial item No. 7 above but of size 50 Sqmm 3.5 core |
| 12 | All as per serial item No. 7 above but of size 70 Sqmm 3.5 core |
| 13 | All as per serial item No. 7 above but of size 95 Sqmm 3.5 core |
| 14 | All as per serial item No. 7 above but of size 120 Sqmm 3.5 core |
| 15 | All as per serial item No. 7 above but of size 240 Sqmm 3.5 core |
| 16 | Taking upthe existing cables from trenches of any size any type all as specified and directed by Engr-in-Charge. |
| 17 | M&L for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection . |
| 18 | Taking down defectivestreet light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commissioning complete all as directed by Engr-in-Charge.Note: a) The M/L forItems likelamp, electronicdrivers, surge protection devices etc.shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc. shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc. if any required at site. d) The M/L forrepairs toLED panel is not included in the scope and shall be measured and paid separately. |
| 19 | supply and fix in repair Electronic digital Timer (Astronomical) suitable for street light timer DB panels . |
| 20 | Supply only the following spares suitable for LED street/Flood light fittings :- |
| 21 | Electronic driver potted type IP-65, suitable for 90 to 120 W LED light fitting |
| 22 | Electronic driver potted type IP-65, suitable for 70 to 80 W LED light fitting |
| 23 | Electronic driver potted type IP-65, suitable for 30 to 60 W LED light fitting |
| 24 | Surge protection device of capacity 10 KV suitable for LED light fitting |
| 25 | Disconnecting from electric supply and remove from bracket/pole and dismantling LED light fitting of Make : Crompton/Phillips/C&S/Havells/Wipro/Henolix of capacity 25 to 120 W by strip opening the electronic driver, LED panel complete, identifying defective LEDs, make it functional by complete soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. |
| 26 | Taking down old unserviceable security light fittings roadway luminaire type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 2500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 30 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. completeand testing on completion all as specified and as directed.Note: The GI pipe bracket if requiredwill be measured and paid separately under relevant schedule items |
| 27 | Taking down old unserviceable security light fittings roadway luminaire type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 45 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. completeand testing on completion all as specified and as directed.Note: The GI pipe bracket if requiredwill be measured and paid separately under relevant schedule items |
| 28 | Taking down old unserviceable security light fittings roadway luminaire type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. completeand testing on completion all as specified and as directed.Note: The GI pipe bracket if requiredwill be measured and paid separately under relevant schedule items |
| 29 | Taking down old unserviceable security light fittings roadway luminaire type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72/70 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. completeand testing on completion all as specified and as directed.Note: The GI pipe bracket if requiredwill be measured and paid separately under relevant schedule items |
| 30 | Taking down old unserviceable street light fittingsfrom any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 9000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 90 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. completeand testing on completion all as specified and as directed.Note: The GI pipe bracket if requiredwill be measured and paid separately under relevant schedule items |
| 31 | Taking down old unserviceable security light fittings roadway luminaire type from any height and Supply & fixing LED \"inverter type bldg security light fittings with inbuilt battery backup for min 3 to 4 hrs, comprising of epoxy powder coated housing, enclosed with PC cover in frame, (with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt roadway luminaire type with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. completeand testing on completion all as specified and as directed.Note: The GI pipe bracket if requiredwill be measured and paid separately under relevant schedule items |
| 32 | Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 15000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 150 watt,with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. completeand testing on completion all as specified and as directed. |
| 33 | Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 200 watt,with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. completeand testing on completion all as specified and as directed. |
| 34 | Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt,with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. completeand testing on completion all as specified and as directed. |
| 35 | Dismantling old unserviceable flood light fittings from any position exceeding 7.5m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 100/120 watt,with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary angle iron supports, clamps etc complete and testing on completion all as specified and as directed. |
| 36 | S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fittingtesting and commissioning all as directed. |
| 37 | M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete. |
| 38 | M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work. |
| 39 | S & F timelite distribution boards (street light DBs) 40 A 3 pole with 230 V Astronomical time switch complete all as directed including dismantling old one. |
| 40 | S&F loop-in/loop-out box of outer size 250x210x115 mm made out ofFRP(Hot moulded type) with weather proof canopy and locking screws along with5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc. complete in the box, duly fixed to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable completeall as directed including dismantling old one. |
| 41 | M & L for disconnecting burnt end or portion of UG Cable, removing the cable from loop including necessary excavation and earth work, relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminal for cable of cross sectional area 10 Sqmm 2 core to 95 Sqmm 3.5 core of LT cable to pole, main switch, LT Panel etc. complete all as specified and as directed . |
| 42 | Removingexisting 1100 volts grade,XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductorof sizes6 Sqmm 4 core to 70 Sqmm 3.5 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule |
| 43 | M & L for preparation of old painted surfaces of 09/11 m long PCC poles incl removing oily/greasy sports and applying one coat of synthetic enamelpaint of black and yellow in alternate strip of 30 cm width upto 1.5 mtr height includingapplying a coat of white wash on pole cooping and lettering the pole details with white letters/black background etc. complete all as directed |
| 44 | Material and labour for painting to steel tubular pole 9.00/11.0 metre long with one coat of red oxide on pole and two coats of synthetic enamel paint up to 1.20 metre height from ground level in 30 cm alternative black and yellow strips and remaining portion with two coats of aluminium paint complete all as specified and directed by Engineer-in-Charge |
| 45 | Material and labour fornumbering of pole no.Usingstencils with two coats of Black round and fonts with white in colourcomplete all as specified and directed by Engineer-in-Charge. |
| 46 | Supply and fixing in repair for200 AMP MCCB, 3pole 415 volt, AC 50 Hz, 25 KAwith adjustable thermal andmagnetictripping system against over load and short circuit conditions incl neutral adjustmentsuitable of Existing panel boardcomplete all as specified and directed. |
| 47 | Supply and fixing in repairfor160 AMP MCCB, 3pole 415 volt, AC 50 Hz, 16 KAwith adjustable thermal andmagnetictripping system against over load and short circuit conditions incl neutral adjustmentsuitable of Existing panel boardcomplete all as specified and directed. |
| 48 | Supply and fixing in repair for400 AMP MCCB, 4 pole 415 volt, AC 50 Hz,36 KAwith adjustable thermal andmagnetictripping system against over load and short circuit conditions incl neutral adjustmentsuitable of Existing panel board complete all as specified and directed. |
| 49 | Supply and fixing in repair250 AMP MCCB, 4 pole 415 volt, AC 50 Hz,25 KAwith adjustable thermal andmagnetictripping system against over load and short circuit conditions incl neutral adjustmentsuitable of Existing panel boardcomplete all as specified and directed. |
| 50 | Supply and fixing in repair200 AMP MCCB,4 pole 415 volt, AC 50 Hz, 25 KAwith adjustable thermal andmagnetictripping system against over load and short circuit conditions incl neutral adjustmentsuitable of Existing panel board complete all as specified and directed. |
| 51 | Supply and fixing in repair160 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 16 KAwith adjustable thermal andmagnetictripping system against over load and short circuit conditions incl neutral adjustmentsuitable of Existing panel board complete all as specified and directed. |
| 52 | S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carrying capacity 32 to 40 Amps complete including control wiring thimbles etc. complete all as directed. |
| 53 | S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carrying capacity 40 to 100 Amps complete including control wiring thimbles etc. complete all as directed. |
| 54 | Supply, installing, testing and commissioning of LT feeder pillar box size 1200x1200x500mm factory madecubicle indoor type, fabricated out of 2.00 mm thick CRCA sheet with angle iron base frame made of 40 x 40 x 6mm , 45 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-66 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc. with locking arrangement, with back door openable (Screwed), legs groutedin PCC complete including paintingwith two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete in all respect for Bay work station and includingprovn of the following:-Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.i)Aluminium Bus bar 600 A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos)with PVC sleeve insulationii)4 Pole MCCB, 415 V, Adjustable type with breaking capacity 35 KA,400 Amp rated, All MCCB\"s should have Company Made Spreaders Links.- 01 Nos (incoming)iii) MCCB 4 pole 415 V 3 phase 250 Amp, 36 KA (Thermal magnetic release) Ics=100%Icu, All MCCB\"s should have Company Made Spreaders Links.- 02 Nos (outgoing)iv) MCCB 3 pole 415 V 3 phase 160 Amp, 25 KA (Thermal magnetic release) Ics=100%Icu, All MCCB\"s should have Company Made Spreaders Links.- 02 Nos (outgoing) v) Digital Voltmeter of size 96x96mm 0-500 volts with selector switch - 01 Nos |
| 55 | Supply, installation, testing and commissioning of LT paneloutdoor type suitable for 3 phase 415 Volt of both side opening double door with push type metal lock, heavy duty wide hinges, separate common access cable alley, indoor type made out 3.15 mm thick CRCA sheet with angle iron frame of size 80 x 80 x 6 mm cubical type complete with 4 Nos Aluminium bus bar 200 Amp, MCCB 4 Pole , 100 Amp, 415 V, 25 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 01 Nos (incomer) &RYB LED indicator- one set with IP 54 as per IS 13947 protection, internal wiring by FRLS grage multi stranded PVC insulated copperconductor of size not less than 10 Sq.mm duly marked with ferrul, incl powder coated paintingin inner & outer side, including making all suitable necessary electrical connection completeall as directed by the Engineer –in - Charge. Note : (i) The panel shall be as per CPRI certificate (ii) Rates inclusive of PCC complete(iii) The rates deemed to be inclusive necessary PCC for grouting of panels. |
| 56 | S&F in repair Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor. |
| 57 | S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 3 to 15 KVAR. |
| 58 | S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 20 to25 KVAR. |
| 59 | M&L in replacement of existing unserviceable MCB 25-40 Amps TPN 415 volts at different places in LT Panels/APFC panels including required electrical connections & testing all as directed . |
| 60 | M&L in replacement of existing unserviceable MCB 32 - 63 Amps TPN 415 volts at different places in LT Panels/APFC panels including required electrical connections & testing all as directed . |
| 61 | Material and labour for cleaning of treated water tank of RCC construction and of approx. size 3.4x3.4x1.5 mof STPby bailing out the accumulated raw water at the bottom and removing the complete silt/sludge/dirt from the tank and disposing it away from site as directed, scrapping the tank inner walls and bottom with wire brush and cleaning the tank inner walls and bottom with the bleaching powder slurry completely incl applying one coat of white wash to entire tank externally complete all as directed by Engineer-in-Charge. Note: (a) The rate deemed to be inclusive of T&P and transportation required for disposal of sludge/dirt away from the site. (b) The cleaning of tank shall be performed once in three months all as directed . |
| 62 | M & L for carrying out chemical analysis (BOD/COD) test of treated sewer water of STPfrom Govt authorized laboratory or PBTI lab Chandigarh all as per CPCB/PPCB norms as directed and following parameters are to be tested pH, TSS, BOD 3 days, COD, Fecal coliform, etc. complete all as specified and directed.Note : The rate quoted is deemed to be inclusive of charges for testing, collection and transportation of water samples in sealed PVC container to test lab complete. |
| 63 | Material and labour for chlorination of treated sewage water with Sodium hypochlorite solution (Grade-I) as per IS 11673-1992for treatment at Chlorine contact & treated water tank of STPfor maintaining residual chlorineall as directed by manufacturers recommendations/instructions. |
| 64 | M&L for taking out existing any type pumpset/air blower of following capacity for servicing by disconnecting motor and blower/ pump set, pipe line and removing of all parts like bearing, bushes, impeller, shaft etc. cleaning all surfaces and scales/ sludge/ dirt/formed inside/out side pumpset/blower etc. Lubricating/ greasing at proper places and re fixing in position with all serviceable parts with motor incl painting with one coat of anti corrosive paint over red oxide primer and writing MES /SM No and testing and commissioningall as directed by Engr-in-charge.( Note -spares like bearings will be measured and paid separately against supply only) |
| 65 | 02 HP to 05 HP |
| 66 | 7.5 HP to 10 HP |
| 67 | Supply only ball bearings for following capacity pump sets/air blower |
| 68 | 02 HP to 05 HP |
| 69 | 7.5 HP to 10 HP |
| 70 | M&L for dismantling the defective induction motor of any make & capacity 2 HP to 15 HP , any duty or any class of insulation from the bed, duly coupled with pump/ compressor, transporting to workshop, removing burnt out winding from stator/ rotor, rewinding with suitable gauge of super enameled copper wire of approved make and replacing drive end and non drive end bearings, insulation materials, varnishing, heating, re-assembling, testing and commissioning including replacing base frame bolts & nuts complete all as directed. Notes: (i) Motor removed for re-winding shall be overhauled completely and quoted rate is inclusive for the same. |
| 71 | supply and fix in replacement power contactor 3 pole of current carrying capacity suitable for range 2 HP to 5 HP rated motor with coil operating voltage 230 V/ 415 V AC 50 HZ. |
| 72 | supply and fix in replacement power contactor 3 pole of current carrying capacity suitable for range 5 HP to 10 HP rated motor with coil operating voltage 230 V/ 415 V AC 50 HZ. |
| 73 | supply and fix in replacement Thermal overload relay suitable for 2 HP to 5 HP rated motor. |
| 74 | supply and fix in replacement Thermal overload relay suitable for 7.5HP to 10 HP rated motor. |
| 75 | Supply and fix in star-delta timer. |
| 76 | Supply only (Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas, and stronger than bleaching powder, and sodium Hypochlorite) with chlorine content 65 to 70 % , packing in 45 kg drum complete all as specified and directed by Engr-in-Charge. |
| 77 | Supply only stable bleaching power (SBP)(Calcium hypochloride)Grade I,availabilty Chlorine 34 % min,Stability 1/15 Max,moisture 0.3% max etc. all as per IS, packing in 25 kg bag/drum complete all as specified and directed by Engr-in-Charge. |
| 78 | Maintenance and servicing of DG set consistingof replacement of fuel filter, air filter and lub oil filter including replacement of engine oil all as directed and testing on full connected load for the following capacity of DG Sets and any make as per OEM. Note: Engine oil will be measured and paid separately. |
| 79 | DG Set upto 62.5 KVA |
| 80 | DG Set 62.5 to 200 KVA |
| 81 | M & L for replacement of existing unserviceable Fan Belt and testing complete for the following capacity of DG Sets and any make as per OEM. |
| 82 | DG Set upto 62.5 KVA |
| 83 | DG Set 62.5 to 200 KVA. |
| 84 | M & L for replacement of existing unserviceable Hose Pipes with clamps and testing complete for the following capacity of DG Sets and any make: :- |
| 85 | DG Set upto 62.5 KVA |
| 86 | DG Set 62.5 to 200 KVA. |
| 87 | Taking out the old unserviceable radiator from the DG set and taking it to work shop for overhauling & cleaning descaling with restore plus solution, removal of leakage, welding brazing & refixing it duly repaired etc. complete all as directed for the following capacity of DG Sets and any make as per OEM. |
| 88 | DG Set upto 62.5 KVA |
| 89 | DG Set 62.5 to 200 KVA. |
| 90 | Dismantling of self starter and supply and fix new selfstarter 12 V ofcapacity of OEM make complete all as specified and directed. |
| 91 | M&L for repair and overhauling of unsv dynamo/alternator 12 V of any capacity DG set including repair/replacement unsv/defective spares such as field coil, armature winding, carbon bushes, clutch bushes and pinion assy complete all as specified and directed. |
| 92 | M&L for repair and overhauling of unsv of battery charger of capacity 24 V including repair/replacement unsv/defective spares such as transformer, rectifier/diode plate, Ammeter, Voltmeter, selector switch, capsule fuse and neon indicator lamp. |
| 93 | S&F in repair AVR with functions to adjust generator output voltage, prevent voltage hunting, set under frequency roll off knee point, set generator droop to 5% at full load, match AVR input to accessory output, set the over excitation cut off level, set initial frequency related voltage dip, over-voltage protection cut off level, maximum short circuit current with sensing input voltage range 170 - 250 V AC max, 50 -60 HZ frequency with output max upto 120 V DC, continuous current 2.7A & transient 6A for 10 sec including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG sets of capacity upto 62.5 KVA |
| 94 | All as per srl item No. 77 above but for DG set capacity above 62.5 to 200 KVA |
| 95 | M & L for repair of Water pump of capacity upto 200 KVA DG set including replacement of defective unsv spare part of any make and model and refix the same after repair complete all as specified and as directed |
| 96 | M&L for Calibration of Fuel pumpincluding replacement of unsv/defective spares of capacity upto 200 KVA DG Set of any make and model complete all as directed. |
| 97 | M&L for overhauling and calibration of fuel injector assemblyincluding replacement of unsv/defective spares of capacity upto 200 KVA DG Set of any make and model complete all as directed. |
| 98 | Supply and fix in replacement battery leads set, PVC insulated multistranded, copper conductorof min size 35 sqmm 1 mtr long each duly fixed with brass clamps, copper lugs suitable for DG setsof different capacities. |
| 99 | M/L for replacement of coolant for radiator forDG set at various locations. |
| 100 | M/L for replacement of Lub Oil (Engine Oil) of grade 20W40 for Engine forDG set at various locations. |
| 101 | M & L for replacement of starter ring gear assembly for capacity50 to 110 KVA DG set. |
| 102 | M & L for replacement of existing unserviceable oil pressure sensor of any pressure range, any current rating as per site requirement along with other connected accessories complete for the following capacity of DG Sets and any make: :- |
| 103 | DG Set upto 62.5 KVA |
| 104 | DG Set above 62.5 to 200 KVA |
| 105 | Supply & fixing in replacement of unsv 4 Pole on load changeover switch of current carrying capacity 100 Amps including necessary additional/alteration to busbars of existing panel etc. complete all as directed. |
| 106 | All as per srl item 87 above but of capacity 63 Amps Capacity |
| 107 | All as per srl item 87 above but of capacity 200 Amps Capacity |
| 108 | Supply & fixing in replacement of unsv 4 Pole off load changeover switch of current carrying capacity 400 Amps including hanging/grouting to the wall with the help of fast nut, nut bolts, screws, etc making all the necessary electrical connection as required at the site complete all as directed. |
| 109 | All as per srl item 90 above but of capacity 63 Amps Capacity |
| 110 | All as per srl item 90 above but of capacity 200 Amps Capacity |
| 111 | Annual Online Recharge of sim cardrequired in online monitoring of parameters of STP, recharge plan should have at least 2GB data per day, new sim may need to be provided in case old sim stops function for any reasoncomplete all as specified and directed by Engr-in-Charge. |
| 112 | Supply only Copper thimble(Lugs) of size suitable for connecting cable of size 25 Sqmm to 50 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 113 | Supply only Copper thimble(Lugs) of size suitable for connecting cable of size 70 Sqmm to 120 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 114 | Supply only Alumunium thimble(lugs) of size suitable for connecting cable of size 25 Sqmm to 50 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 115 | Supply only Alumunium thimble(lugs) of size suitable for connecting cable of size 70 Sqmm to 120 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 116 | Supply only Alumunium thimble(lugs) of size suitable for connecting cable of size 150 Sqmm to 240 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 117 | Supply only Alumunium thimble(lugs) of size suitable for connecting cable of size 240 Sqmm to 400 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 118 | Taking out the old unserviceable battery from the DG Set and supply and fix new 12 V, 180 AH maintenance free battery including testing and commissioning complete all as specified and directed. |
| 119 | M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level usinggalvanised iron strip 32x6mm earthing lead as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remain surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge incl testing on completion. Note: Returning & filling of earthing would be with vegetable soil free from gravel & boulder. |
| 120 | M&L for carrying out servicing& maintenance of UPS of capacity upto 15 KVA of Make : M/s SUKAM/Delta by strip opening ofUPS,inspection/ servicing of all spare parts such asDrive cards, relay cards, Ac capacitors, inverter cooling fan, ceramic fuses, batteries and including replacing the defective spares if any complete, reassembling, calibration of UPS complete andtesting & commissioning complete all as directed. Note : Major Spares such as Inverter Card/ Rectifier Card, AC/DC capacitors, replacement of Batteries required will be measured & paid separately under relevant Schedule. All other spares required for rectifier & inverter section such as other connecting cards, Input fuses, SCR, Inverter cooling fan etc. for keeping the UPS in operational state are deemed to be included in the quoted rate. |
| 121 | Supply only the following spares for carrying out repairs to UPS of capacityupto 15 KVA of Make: Sukam/ Delta under item No.102 above :- |
| 122 | Inverter card |
| 123 | Rectifier Card |
| 124 | AC capacitor |
| 125 | DC capacitor |
| 126 | 12 V 42 AH SMF batteries |
| 127 | Cutting, trimming of hanging/ extended branches of trees upto a distance 3 meter from the overhead HT/LT line and making the line clear upto the entire length of the feeder including removal and disposal of the cut tree branches 50 meters away from the site complete all as specified and directed. Note : The Rates shall inclusive of T&P, hydraulic ladder, equipment such as motorized diesel operated hacksaw etc. complete. One span comprises of 3 to 5 conductors of any distance between one pole to adjacent pole including trimming of all tree branches in vicinity & around poles /conductor & will be measured as one span. Necessary prior permission shall be obtained from concerned I/C JE E/M before carrying out the work. All safety measures & insurance to the staff undertaking the Job shall be the Contractor\"s responsibility. |
| 128 | M&L for replacement of acrylic sheet diagram of main incoming and outgoing elect supply/water supplyto various destination and generator supply destination all as directed and specified size of display not less than 1.0x2.0 mtr with all decoration as specified. |
| 129 | M&L for replacement ofacrylic sheet DO and DON\"T instructions in Hindi/Punjabi and English language for elect supply installations and water supply installations all as specifiedsize of display not less than 2.0x1.0 ft with all decoration as specified. |
| 130 | M&L for replacement ofacrylic sheet instructions for pump operation in Hindi/Punjabiall as specifiedsize of display not less than 2.0x1.0 ft with all decoration as specified. |
| 131 | M&L for fire point comprising of the following. (a) CO2 fire extinguisher 4.5 Kg (02 Nos), b) Dry carbon powder (ABC)-05 Kg (02 Nos) ,ceiling Hook, fire beater, sand buckets 9 mtrs capacity-02 Nos ,Showel complete with angle iron stand duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer incl dismantling old unsv one. |
| 132 | M&L for replacement ofelectric shock and its management with picture in Hindi/Punjabiall as specifiedsize of display not less than 2.0x1.0 ft with all decoration as specified. |
| 133 | M&L for replacement ofMaintenance schedule of Sub stations instructions board on acrylic sheet in Hindi/Punjabiall as specifiedsize of display not less than 3.0x1.5 ft with all decoration as specified. |
| 134 | M&L for replacement ofYearly periodical maint of HT Circuit Breakers on acrylic sheet in Hindi/Punjabiall as specifiedsize of display not less than 3.0x1.5 ft with all decoration as specified. |
| 135 | M&L for replacement ofDO\"s & DON’T\"s for HT circuit breakers on acrylic sheet in Hindi/Punjabiall as specifiedsize of display not less than 3.0x1.5 ft with all decoration as specified. |
| 136 | Supply and laying in repairs synthetic Insulating Mat of size 2m X 1m and 2mm thickfor up to 3.3 KV Volts made from synthetic insulating material, free from any insertions leading to deterioration of insulating properties. Note : The upper surface should have small aberration (Rough Surface) with out edges to avoid slippery effects. The mat should be fire retardant & self extinguishingcomplete all as specified and directed by Engr-in-Charge. |
| 137 | M&L for painting of all GI pipe at pump house like header system and connected pipes, and valve pit chamber GI cover as per existing sizescomplete including cleaning, scraping of old rusted surface paint inside and outside of panel surface with two coats of synthetic enamel paint and writing of SRL No as per existing size complete all as specified and directed |
| 138 | Supply & fixing in repairs light bollard/Dome type 12 watt for gate and garden 24 inch pole height all as per site requirement and spd and directed by the Engr-in-Charge. |
| 139 | Material, labour , testing & commissioning of straight through jointing kit, heat shrinkabletype suitable for XLPE/ PVC cables of size 10 to 16 Sqmm 4 core with working voltage 1100 volts . |
| 140 | Material, labour , testing & commissioning of straight through jointing kit, heat shrinkabletype suitable for XLPE/ PVC cables of size 25 to 50 Sqmm 3.5/4 core with working voltage 1100 volts . |
| 141 | Material, labour , testing & commissioning of straight through jointing kit, heat shrinkabletype suitable for XLPE/ PVC cables of size 70 to 120 Sqmm 3.5 core with working voltage 1100 volts . |
| 142 | Material, labour , testing & commissioning of indoor Endjointing kit, heat shrinkabletype suitable for XLPE/ PVC cables of size 16 to 50 Sqmm 3.5/4 core with working voltage 1100 volts . |
| 143 | Material, labour , testing & commissioning of indoor Endjointing kit, heat shrinkabletype suitable for XLPE/ PVC cables of size 70 to 120 Sqmm 3.5 core with working voltage 1100 volts . |
| 144 | Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail