| 1 | M & L for Servicing of3 phase precision air conditioner of capacity 7 TR(bottom discharge type) including oiling/greasing the blower motor, cleaning the evaporator (tower type) condenser coils/cooling coil externally to remove the dust, replacement of defective thimbles etc by the OEM refrigeration mechanic complete all as specified and as directed by Engineer-in-Charge. Note:- (i) Any u/s items need to be replaced/gas charging etc shall bepaid seperately under respective items. |
| 2 | M & L for Servicing of3 phase package air conditioner of capacity 7.5 TRincluding oiling/greasing the blower motor, cleaning the evaporator condenser coils/cooling coil externally to remove the dust, replacement of defective thimbles etc by the experiencedrefrigeration mechanic complete all as specified and as directed by Engineer-in-Charge. Note:- (i) Any u/s items need to be replaced/gas charging etc shall bepaid seperately under respective items. |
| 3 | S&F in replacement vaccume filter of package type AC of capacity 7.5 TR including taking out unserviceable complete all as specifed and directed. |
| 4 | S&F in replacement contactor 40 A 3 phase sutable for package typr Unit of 7.5 TR capacity including taking out unserviceable complete all as specified and directed. |
| 5 | Repair of PCB for package type unit of 7.5 Ton capacityincluding taking out unserviceable PCB complete all as specified and directed . |
| 6 | Repair ofFan Motor of package type unit of 7.5 TR Capacityof approved Make and required Size to suit existing AC including taking out the unservice-able Fan Motor from the AC, complete all as specified and directed. |
| 7 | Supply, assembling and erection of PGI sheet 22 gauge with TDF flange rectangular/square duct made out of \"L\"shaped hollowprofile ,duly factory boxed including all accessories such as Corner ,Cleat,Carriage bolt,Gasket and appropriate sealant on longitudinal joints etc including taking down old rusted duct complete all as specified and directed. |
| 8 | M&L in replacement Remotewith ful kit of package type unit of 7.5 TR capacity(As per sample or as per site requirement)all as specified and as directed. |
| 9 | Checking, servicing, preventive maintenance, cleaning (Dry and Wet), inspection and testing of window/Split type Air condineer of capacity 1.5/2 Ton of invertor type or any modal and make at site in Multi story buildings as per OEM guideline for safety and performance by means chekcing operation performance parameters, cleaning of blower, condenser fan, cleaning or replacing the air filters, cleaning the condeser and evaporator coils, checking the refrigerant level and testing for leakage and topping off refrigerant level, inspecting and tightening electrical connections, lubricating moving parts, checking thermostate calibration, checking the PCB controler cards and capacitor * Remote control handset in and including anti corrosive coating blue/gold fin on condenser and evaorator coils complete all as specified and as directed by EIC. |
| 10 | All as per item Ser No 9 above but cassette type Inverter ACof 3.0 ton |
| 11 | All as per item Ser No 9 above but cassette type Inverter AC 4.1 Ton |
| 12 | M&L in replacement Fan Motor of AC (Window/ Split Type) 1.5 TR Capacityof approved Make and required Size to suit existing AC including taking out the unservice-able Fan Motor from the AC, complete all as specified and directed. |
| 13 | All as per Item No.12here–in–before, but AC(Window/Split Type). 2.0 TR Capacity |
| 14 | M&L Rewinding Fan Motor of AC 1.5/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt Winding, complete all as specified and directed. |
| 15 | M&L in replacement Air circular BlowerFan Motor ofAC (Split Type), 1.5 TR/2.0/4.00TR Capacity including taking out unser-viceableAir circular BlowerFan Motor complete all as specified and directed. |
| 16 | M&Lin replacement Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filterfrom AC complete all as specified and directed. |
| 17 | M&Lin replacement Air Filtersuitable of AC (Split type)1.5 TR/2.0 TR Capacityincluding taking out unserviceableAir Filtercomplete all as specified and directed. |
| 18 | M&Lin replacementCapacitorRunning 4-6 mfd suitable for new/star rated for AC (Window/Split Type)1.5 TR/2.0 TR Capacity and of any make includingtaking out unserviceableCapacitor from ACcomplete all as specified and directed. |
| 19 | M&Lin replacementCapacitorRunning 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type)1.5 TR/2.0 TR Capacity and of any make includingtaking out unserviceableCapacitor from ACcomplete all as specified and directed. |
| 20 | M&L in replacement Fan MotorBlades AC (Window/Split type)1.5/2.0 TR capacity including taking out unserviceable Blades of FanMotor from AC complete all as specified and directed. |
| 21 | M&Lin replacement Front Plastic Grill (as per Sample) of AC (Window type)1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from ACall as per existing and complete all as specified and directed. |
| 22 | M&L in replacement Front Plastic Grillfor inner unit (asper Sample) of AC (Splittype)1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing complete all as specified and directed. |
| 23 | M&L in replacement Runner for air blower motor of AC(split type)AC 1.5/2.00TR capacity (As per sample or as per site requirement)including Runner of Air Blower Motor from ACall as per existing complete all as specified and directed. |
| 24 | M&L in replacement Selector Switch Knob of AC(Window/ Split Type)1.5 TR/2.0/3.00 TR Capacity including taking out unserviceable Selector Switch Knob from ACcomplete all as specified and directed. |
| 25 | M&L in replacement Starting Relay of AC(Window/Split Type) 1.5 TR/2.0/3.00TR Capacityincluding taking out unser-viceable Starting Relay from ACcomplete all as specified and directed. |
| 26 | M&L in replacement Strainer with Capillary Tube of ACWindow/ Split Type) 1.5 /2.0TR Capacity (including taking out unserviceable Strainer with Capillary Tubefrom ACcomplete all as specified and directed. |
| 27 | M&Lin replacement Thermostat Switch of AC(Window/Split Type) 1.5 TR/2.0 TR Capacityincluding taking out unserviceable Thermostat Switch from ACcomplete all as specified and directed. |
| 28 | S&F in replacement cooling coil suitable forwindow type room AC 1.5/2 TR including taking out unserviceable cooling coilof capacity 1.5/2 TR complete all as specified and directed. |
| 29 | S&F in replacementCondensing coil suitable forwindow type AC 1.5/ 2 ton including taking out unserviceable Condensing coil of capacity 1.5/2 ton complete all as specified and directed. |
| 30 | S&F in replacement Condensing coil suitable for split type AC including taking out unserviceable Condensing coil of capacity 2 ton complete all as specified and directed. |
| 31 | S & F in replacement cooling coil suitable for split type ACincluding taking out unserviceable cooling coilup to capacity 2 ton complete all as specified and directed. |
| 32 | S&F in replacement Indoor unit suitable for 1.5 TR split type ACincluding taking out unserviceable Indoor unitcomplete all as specified and directed. |
| 33 | S&F in replacement outdoor unit suitable for 1.5 TR splittype AC without compressor including taking out unserviceable outdoor unitcomplete all as specified and directed. |
| 34 | S&F in replacement Indoor unit suitable for up to 2 TR split type ACincluding taking out unserviceable Indoor unitcomplete all as specified and directed. |
| 35 | S&F in replacement outdoor unit suitable for up to 2 TR splittype AC without compressor including taking out unserviceable outdoor unitcomplete all as specified and directed. |
| 36 | S&F in replacement of Hermitacally sealed compressor for split/ window type AC capacity 1.5 Ton complete all as specified and directed. |
| 37 | S&F in replacement of Hermitacally sealed compressor for split/ window type AC capacity 2.0 Ton complete all as specified and directed. |
| 38 | Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt Compressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 includingre-connection of Electric Connections, functioning AC complete in all respect and Testing, complete all as specified and directed. |
| 39 | All as per Item No. 38 here–in–before, but AC 2.0 TR Capacity (Window/Split Type) complete all as specified and directed. |
| 40 | M&L in replacement PCB with remote for windowtype inverter AC up to 1.5/2 Ton capacityincluding taking out unserviceable PCB complete all as specified and directed . |
| 41 | M&L in replacement PCB with remotefor Split type inverter AC 1.5/2 Ton capacityincluding taking out unserviceable PCB complete all as specified and directed . |
| 42 | M&L in replacement PCB & motherboard with remotecomplete setforInverter Split type AC up to 2 Ton capacityincluding taking out unserviceable PCB complete all as specified and directed . |
| 43 | M&L in replacement Remoteof inverter type AC ( Window/Split Type) 1.5/2.0 TR capacity(As per sample or as per site requirement)all as specified and as directed. |
| 44 | S&F in replacement wiring kit suitable for 1.5 to 2.0 ton capacity AC complete including taking out unserviceable wiring kit all as specified and directed. |
| 45 | S&F in replacement gas charging pin valve complete including taking out unserviceablepin valve all as specified and directed. |
| 46 | Taking out window type AC complete unit from any height/ any floor up to fourstorey buildingand shifting to another locationin the sameor other building in the complex including refixing of the unitcomplete all as specified and directed. |
| 47 | Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to fourstorey buildingbyincluding pumping down the gas into thecompressor by controlling the suction and discharge valves , disconnecting the suction and discharge copper piping and shifting to another locatiionin the sameor other building in the complex including refixing of the unit complete all as specified and directed. |
| 48 | Supply and charging the gas refrigerant R22 (including refrigerant) of window type AC upto 2 ton capacityincluding testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogengas complete all as specified and directed. |
| 49 | All as per ser item No. 48 here-in-before but R- 410 for split/cassette type AC of sizecapacity complete all as specified and directed. |
| 50 | All same as per item No 48 here-in-before but R134 for deep fridger/water cooler of any size capacity complete all as specified and directed. |
| 51 | All same as per item No 48 here-in-before but R-32 Refg of any type capacity AC complete. |
| 52 | M&L for replacement of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed. |
| 53 | All as per ser item No. 52 here-in-before but 1/2\"complete all as specified and directed. |
| 54 | S&F in replacement compressor shut off valve 3/8\" for split AC up to 2.00 ton capacity complete all as specified and directed. |
| 55 | S&F in replacement compressor shut off valve 5/8\" for split ACup to 2.00 toncapacity complete all as specified and directed. |
| 56 | S & F in replacement of electrolyte grade copper tubing of size 1/4\" suitable for any type ofsplit type ACincluding synthetic rubber foam complete all as specified and directed.Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building. |
| 57 | All as per ser item No. 56 here-in-before but size 1/2\"complete all as specified and directed. |
| 58 | S&F in replacement High density polyethylene pipes 20 mm dia (HDPE) of pressure rating 6 kgf/cm2, laid in wall/ceilingincluding all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 6 (six) storey complete all as specified and directed. |
| 59 | S&F in replacement Plastic flexible pipe for drain of suitable/existing size including necessary accessories to proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed. |
| 60 | S&F in replacement Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted. |
| 61 | S&F in replacement Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted. |
| 62 | S&F in replacement of PVC insulated flexible copper conductor 3 core 1100 volts grade of size 2.50 Sqmm including casing caping complete all as specified and directed. |
| 63 | S&F in replacement AC stand suitable for wall mounted for out door AC unit up to cap of 1.5/2/5 ton capacity necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete allas specified and as directed by Engr-in-charge. . |
| 64 | M&L for servicing of water coolerof any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed. |
| 65 | S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed. |
| 66 | S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed. |
| 67 | S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed. |
| 68 | M&L for preparation of old painted surfacesof water cooler by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting complete all as specified and directed. |
| 69 | S&F in replacement fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 ltrs of any make complete all as specified and directed. |
| 70 | S&F in replacement of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed. |
| 71 | S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed. |
| 72 | S&F in replacement water collection tray made of CGI sheet suitable for window AC upto 2 Ton capacity complete all as specified and directed. |
| 73 | S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 150 ltrs capacitycomplete all as specifed and directed. |
| 74 | M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside repair/replacement of defective/unserviceable parts, reasing of fan kit, motor, water pump and connected accessories complete all as specified and directed. Note : Unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule. |
| 75 | M&L for painting ofdesert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed by Engr-in-Charge.Note : The rates are inclusive of taking down coolerfrom any height, removal to workshop for painiting and refixing in position after painting. |
| 76 | S&F in replacement of desert cooler submersiblewater pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing complete all as specified and directed. |
| 77 | S&F in replacementdesert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing complete all as specified and directed. |
| 78 | S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as directed by Engr-in-Charge. |
| 79 | S&F in replacement motor capacitor 2.5/3.15/4 mfd complete all as specified and directed. |
| 80 | S&F in replacement front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed. |
| 81 | S&F in replacement of body without side panels made out of galvanised iron sheets of of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed by Engineer-in-charge. |
| 82 | S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed by Engineer-in-charge. |
| 83 | S&F in replacement of float valve assembly with PTMTferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as directed by Engr-in-Charge. |
| 84 | S&F new wood wool pad,(Khus Khas) set of threecovered by GI wire mesh suitable for desert cooler including taking out the old unserviceable existing pad complete all as specifed & directed |
| 85 | M&L for replacement of aluminium multi wing Fan blade, best qualityas per existing type and size suitable for of desert cooler complete all as specifed and directed |
| 86 | Supply and fix in replacement voltage stabilizer 4 KVA suitable for window/split type AC of capacity upto 1.5 TR working on AC 240 V,50Hz single phase all as specified and as directed. |
| 87 | Supply and fix in replacement voltage stabilizer 5 KVA suitable for window/split type AC of capacity upto 2 TR working on AC 240 V,50Hz single phase all as specified and as directed. |
| 88 | S&F in replacement of metal plug socket of capacity 20 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed. |
| 89 | S&F in replacement Hermatically Sealed compressor upto 310 Ltrs capacity Deep freezer/refrigerator including brazing the sunction and discharge lines complete all specified and directed. labour cost for fixingand taking down costdeemedin quotedrateNote:- Compressor shall procured compressore from authorised dealer and contractor shall submit purchase vouchers alongwith written guarantee/warantee as per manufacturer. |
| 90 | S&F in replacement of single pole with neutral and earth plug top and socket of capacity 20 Amps, 240 volts suitalbe for sheet metal enslousers with single pole complete all as specified and directed. |
| 91 | Supply and Fixing in replacement of Triple pole with neutral and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amps 415 V complete all as specified and directed. |
| 92 | M&L forMCB single pole 6-40 AmpsC Curve 240 Volt complete all as specified and directed. |
| 93 | M&L forMCB single pole & Neutral 20-40 Amps. C Curve 240 V complete all as specified and directed. |
| 94 | M&L in replacement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductordrawn in and includingnon metallic rigid 25 mm dia PVC conduit concealed complete all as directed. |
| 95 | Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below and above 15 cmof earth plate.GI plate connected with galvanised iron strip of 25 x 4mmby means of Copper nuts, bolts and washers.Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:-(a)GI strip of size 25mm x 4mm. (b) Watering pipe GI lightgrade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c) PCC earth pit 30x30x30cm internal dimension constructed in PCC 1:2:4 type B1 exposed surfaces smoothlyfinished with 15mm thick cement mortar 1:6 plaster including RCC 1 :2:4 type B0 reinforced with 8mm dia deformed bars @100 mmc/c bothways pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.(d) Angle iron frame made of 40x40x4 mmfor 30x30 cm PCC pit for holding the pit cover.(e) Apply two coat of syntheticnenamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces. |
| 96 | S&FEarth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip all as specified and directed. Note:- In case excavation & earth work if required, then same will be measured and paid separately under relevent items of BOQ. |
| 97 | Excavation in trenches not exc 1.5 mtr wide and n. exc 1.5 m depth and getting out in soft/loose soil for laying UG cables of various sizes complete all as specified and directed. |
| 98 | Returning, filling in including spreading,leveling, watering and well ramming in layers n. exc 25 cm in any type of soil complete all as specified and directed. |
| 99 | Removing surplus excavated materials to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed. |
| 100 | Supply and lay in trenches burnt brick sub class \"B\" standard size for cable protection keeping width of the brick parallel to the length of the cable all as specified and directed. |
| 101 | Supply and spread clean dry river sand in trenches ,ducts including leveling, punning for cushioning of cables all as specified Note : Punned thickness of sand cushioning shall be measured complete all as specified and directed. |
| 102 | Supply and lay in trenches, fixed to wall / pole/ tray etcUG cable XLPE insulated armouredheavy duty electric UG cable with aluminumconductor1100 volts grade of cross sectional areaofsize 10 sqmm 2 coreincluding taking out old unserviceable cableall as specified and as directed. |
| 103 | Supply and lay in trenches, fixed to wall / pole/ tray etcUG cable XLPE insulated armouredheavy duty electric UG cable with aluminumconductor1100 volts grade of cross sectional areaofsize 16 sqmm 4 core including taking out old unserviceable cableall as specified and as directed. |
| 104 | Supply and lay in trenches, fixed to wall / pole/ tray etcUG cable XLPE insulated armouredheavy duty electric UG cable with aluminumconductor1100 volts grade of cross sectional areaofsize 25 sqmm 3.5 core including taking out old unserviceable cableall as specified and as directed. |
| 105 | Supply and lay in trenches, fixed to wall / pole/ tray etcUG cable XLPE insulated armouredheavy duty electric UG cable with aluminumconductor1100 volts grade of cross sectional areaofsize 35 sqmm 3.5 core including taking out old unserviceable cableall as specified and as directed. |
| 106 | M&L in Replacement of GI bracket made of 40 mm medium grade GI pipe bend to shape approx 1.2 mtr length incl Clamp, nut, bolt, washer etc complete for fixing of street light complete all as specified and directed. |
| 107 | S&F Junction box SMC KIOSK box water proof of size 140x140x95 mm incl fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specified and directed. |
| 108 | S&F Junction box SMC KIOSK box water proof of size 300x200x125 mm incl fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specified and directed. |
| 109 | S&F Copper cable 2.5 Sqm 3 core PVCsheathed multi core for connection of street lightinserting from top in side the pole and connectingin junction box complete including making Hole in Pole as per Site, all as directed by Engineer-in-Charge |
| 110 | M & L for PCC (1:2:4) type B2 using 20 mm graded stone aggregate for coping of pole around poleall as specified and as directed by Engineer-in-Charge. |
| 111 | S&F LED Post Top Lantern 20 W wall luminaire with diffuser and painted spun aluminium deflector including taking down old unserviceable complete all as specified and directed. |
| 112 | S&F in Replacement of LED Post Top Bollard light 9 Wincluding nesessory connnection for fixing complete all as specified and directed. |
| 113 | S&F in replacement of Powder coated pressure die cast aluminium SMD LED street light with heat resistant toughened glass of capacity 35 Watt including taking down old unserviceable complete all as specified and directed. |
| 114 | S&F Powder coated pressure die cast aluminium SMD LED street light with heat resistant toughened glass of capacity 70 Watt including taking down old unserviceable .complete all as specified and directed. |
| 115 | S&F Powder coated pressure die cast aluminium SMD LED street light with heat resistant toughened glass of capacity 90 Watt including taking down old unserviceable complete all as specified and directed. |
| 116 | S&F Powder coated pressure die cast aluminium SMD LED street light with heat resistant toughened glass of capacity 120 Watt including taking down old unserviceable complete all as specified and directed. |
| 117 | S&F LED flood light with pressure die cast aluminium housing 100 Watt Orion 3.0 Series completed with connectionincluding taking down old unserviceable |
| 118 | S&F LED flood light with pressure die cast aluminium housing 120 Watt Orion 3.0 Series completed with connectionincluding taking down old unserviceable complete all as specified and directed. |
| 119 | S&F LED flood light with pressure die cast aluminium housing 170 Watt Orion 3.0 Series completed with connectionincluding taking down old unserviceable complete all as specified and directed. |
| 120 | S&F LED Flood Light 210 watt with pressure die cast aluminium housing complete with all accessories complete all as specified and directed. |
| 121 | S&F in replacement of driver for 45 W LED street light fitting complete all as specified and directed. |
| 122 | S&F in replacement of driver for 75 W LED street light fitting complete all as specified and directed. |
| 123 | S&F in replacement of driver for100W LED street light fitting complete all as specified and directed. |
| 124 | S&F in replacement of driver for 150W LED street light fitting complete all as specified and directed. |
| 125 | S&F in replacement of GI pipe light grade 50mm dia for laying of protection of UG cable complete all as specified and directed. |
| 126 | S&F in replacement of GI pipe light grade 40mm dia for laying of protection of UG cable complete all as specified and directed. |
| 127 | Supply and Fixingin replacement of Timer switchAstronomical type ,415 Volt three Phase of63 Amps rating with Three Pole ML-4contactor incl one Toggle switch for Auto, off and Manual function and incomming MCB TP internally pre wired complete and Fitted inside steel enclosure all as per site requirement and directed by engr-in-charge. |
| 128 | S&F in replacement service cable 1100 volts grade heavy duty PVC insulated aluminium multistranded conductor served with inner sheathing of size 10 Sqmm 2 Core complete including taking down of old burnt cable complete all as specified and directed. |
| 129 | Supply and fix steel tubular swaged poles type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finialand single swan neck, Including foundation and coping complete all as specified and directed. |
| 130 | M&L pole painting 9.0 mtr long with a coat of aluminium paint after preparation of old painting surface by scrapping including marking of black and yellow strip not less than 30 cm width with sythethic enamelled paint from copingupto height 1.5 mtr of pole alternative way including necessary `MES & Pole number to be written in the circular yellow batch on the pole complete all as specified and directed. |
| 131 | M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole andfilling in road cuts/ hard standing complete all as specified and directed |
| 132 | M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate for base of foundationof polecomplete all as specified and directed. |
| 133 | M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate for foundationof pole around polecomplete all as specified and directed. |