| Sl. No. | Item Description |
| 1 | Attending urgent complaints of 15 to 437.5 KVA DG setsunder Zone-B at KWC area on call basis immediatelyby OEM ONLY, issues may be due to fault in AMFpanels, ACB of DG panel , auxillary relays fault, DG control software unit fault, overload, batterydischarge, earth fault, neutral fault, radiator issues, DG set fuse unsv or any other fault not mentioned in this item will be attendedby OEM of respective DG sets including replacement of defective &worn out partsby new sparescomplete all as specified and directed.(Note : - 1. Spares will be measured and paid separately) |
| 2 | Maintenance / Servicingto DG sets of 15 to 437.5 KVA by OEM for respective DG sets will be carried out once in a monthincluding replacement of unsv partsby new spares such as filters, gaskets, V belts,Engine oil, rubber hoses, worm drive clamps, nut bolts and cleaning of alternator with vaccum cleaner and attending faults of AMFpanels etc and greasing of bearings of engine and alternator, checking of batteries, adding distilled water, checking of oil and coolant levelscomplete all as specified and directed.(Note : - 1. Spares required for above maintenance will be measured and paid separately under relevant item. and Servicing to be carried out as per manufacturer instruction) |
| 3 | Supply and fix in Repairs newPVC insulated mulistranded, copper conductor single core 70 sqmm multistranded of 1.25 mtr long each duly fixed with brass clamps, copper lugs suitable for DG sets installed at different locations from battery to starter as battery leads complete all as specified and directed. |
| 4 | Supply only engine oil, multi grade suitable for DG set complete all as specified and directed. |
| 5 | Supply and filling of coolant complete all as specified and directed. |
| 6 | SupplyPetroleum jelly.(1/2 kg plastic sealed container.) |
| 7 | Supply and fill in batteries distilled water for topping up |
| 8 | M & L for repairing of battery charging alternator engine mounted with replacement of any of the unserviceable part such as rectifier with voltage regulator , diode plate , carbon brushes for the following capacities and as directed:- |
| 9 | (a) 24 volts capacity |
| 10 | (b) 12 volts capacity |
| 11 | Supply & fix in repairbattery charging circuit suitable for 12 V,DC in existing DG set panel board including addition/ alteration in wiring system complete with auto transformer, diodes, filter circuit, condensers, DC Ammeter, DC volt meter with selector switches and indicating bulbs etc complete all as specified and directed by Engr-in-Chatrge. |
| 12 | Supply and fixingin repair battery charging circuit suitable for 24 V,DC in existing DG set panel board including addition alteration in wiring system complete with auto transformer, diodes, filter circuit, condensers, DC Ammeter, DC volt meter with selector switches and indicating bulbs etc complete all as specified and directed by Engineer-in-Charge. |
| 13 | S & Fin repair Water temperature gauge including sensor and cable complete as per sample complete all as specified and directed |
| 14 | S & F in repairCT cast resin typeof ratio 200/5 amps, of suitable VA burden complete all as specified and directed |
| 15 | S & F in repairCT cast resin typeof ratio 100/5 amps, of suitable VA burden complete all as specified and directed |
| 16 | S & F in repair Power contactor 415v, 50Hz, AC suitable for following DG set Control panel / AMF Panels for the following capacities and as directed by Engineer-in-Charge. |
| 17 | (a) D. G . Set 15 to 20 KVA |
| 18 | (b) D. G . Set 30 to 62.5 KVA |
| 19 | (c)D. G . Set 160 KVA |
| 20 | (d)D. G . Set 320 KVA |
| 21 | (e) D. G . Set 437.5 KVA |
| 22 | S & F in repair Time delay relay suitable for15 to 437.5 KVA DG Set complete all as specified and directed. |
| 23 | M&L for tappet setting of following capacities of DG sets complete all as specified and directed. |
| 24 | (a) D. G . Set 15 to 20 KVA |
| 25 | (b) D. G . Set 30 to 62.5 KVA |
| 26 | (c)D. G . Set 160 KVA |
| 27 | (d)D. G . Set 320 KVA |
| 28 | (e) D. G . Set 437.5 KVA |
| 29 | Supply only diesel filter element with O ring,suitable for following capacities of DG sets complete all as specified and directed :- |
| 30 | (a) D. G . Set 15 to 20 KVA |
| 31 | (b) D. G . Set 30 to 62.5 KVA |
| 32 | (c)D. G . Set 160 KVA |
| 33 | (d)D. G . Set 320 KVA |
| 34 | (e) D. G . Set 437.5 KVA |
| 35 | Supply only oil filter element with O ring, suitable for following capacities of DG sets complete all as specified and directed :- |
| 36 | (a) D. G . Set 15 to 20 KVA |
| 37 | (b) D. G . Set 30 to 62.5 KVA |
| 38 | (c)D. G . Set 160 KVA |
| 39 | (d)D. G . Set 320 KVA |
| 40 | (e) D. G . Set 437.5 KVA |
| 41 | Supply only by pass filter element with O ring suitable for following capacities of DG sets complete all as specified and directed :- |
| 42 | (a) D. G . Set 15 to 20 KVA |
| 43 | (b) D. G . Set 30 to 62.5 KVA |
| 44 | (c)D. G . Set 160 KVA |
| 45 | (d)D. G . Set 320 KVA |
| 46 | (e) D. G . Set 437.5 KVA |
| 47 | Supply only air filter element suitable for following capacities of DG sets complete all as specified and directed. :- |
| 48 | (a) D. G . Set 15 to 20 KVA |
| 49 | (b) D. G . Set 30 to 62.5 KVA |
| 50 | (c)D. G . Set 160 KVA |
| 51 | (d)D. G . Set 320 KVA |
| 52 | (e) D. G . Set 437.5 KVA |
| 53 | Supply onlyfan belt suitable for following capacities of DG sets complete all as specified and directed :- |
| 54 | (a) D. G . Set 15 to 20 KVA |
| 55 | (b) D. G . Set 30 to 62.5 KVA |
| 56 | (c)D. G . Set 160 KVA |
| 57 | (d)D. G . Set 320 KVA |
| 58 | (e) D. G . Set 437.5 KVA |
| 59 | Supply only belt for battery charging alternator for following capacities of DG sets complete all as specified and directed :- |
| 60 | (a) D. G . Set 15 to 20 KVA |
| 61 | (b) D. G . Set 30 to 62.5 KVA |
| 62 | (c)D. G . Set 160 KVA |
| 63 | (d)D. G . Set 320 KVA |
| 64 | (e) D. G . Set 437.5 KVA |
| 65 | Supply only rubber hose pipe set for water circuit complete with clamps, suitable for following capacities of DG sets complete all as specified and directed :- |
| 66 | (a) D. G . Set 15 to 20 KVA |
| 67 | (b) D. G . Set 30 to 62.5 KVA |
| 68 | (c)D. G . Set 160 KVA |
| 69 | (d)D. G . Set 320 KVA |
| 70 | (e) D. G . Set 437.5 KVA |
| 71 | M & L forDismantling of radiator , taking it to work shop for overhauling & cleaning descaling with acid removal of leakage, welding brazing & refixing it duly repaired etcfor following sizes all as directed by Engineer- in- Charge. |
| 72 | (a) D. G . Set 15 to 20 KVA |
| 73 | (b) D. G . Set 30 to 62.5 KVA |
| 74 | (c)D. G . Set 160 KVA |
| 75 | (d)D. G . Set 320 KVA |
| 76 | (e) D. G . Set 437.5 KVA |
| 77 | Calibration of FIP and injectors from the authorised dealer including petty repairs to makethe FIP functional for the following capacities of DG sets including necessary spares required for smooth functioning of FIP complete all as specified and directed. |
| 78 | (a) D. G . Set 15 to 20 KVA |
| 79 | (b) D. G . Set 30 to 62.5 KVA |
| 80 | (c)D. G . Set 160 KVA |
| 81 | (d)D. G . Set 320 KVA |
| 82 | (e) D. G . Set 437.5 KVA |
| 83 | M&L for repair / overhauling of self starter incl. replacement of carbon brushes, bearing, bushes, rewinding of armature and field etc. and varnishing complete all as directed for the following capacity :- |
| 84 | (a) 24 Volts |
| 85 | (b) 12 Volts |
| 86 | Preparation of old painted surfaces of the DG Set including radiator, fuel tank etc of the following capacities complete degreasing and spray painting the same with two coats of approved synthetic enamel paint of approved shade including writing SM/MES nos on DG set complete allas directed by Engr-in-Charge. |
| 87 | (a)D. G . Set 15 to 437.5 KVA |
| 88 | Supply and fix in repair automatic voltage regulator up to 160 KVADG set with facility of auto / manual mode as per existing capacity and make suitable for DG sets complete as per existing DG sets all as directed by Engineer-In-Charge. |
| 89 | Supply and fix in repair automatic voltage regulator above 320 to 437.5 KVADG set complete as per existing DG sets all as directed by Engineer-In-Charge. |
| 90 | Supply and fix in repair fuel steel braided pipe with benjo bolts and washers etc complete of length upto 30cm long complete all as specified and directed |
| 91 | Supply and fix in repair fuel steel braided pipe with benjo bolts and washers etc complete of length 30 to 45cm long complete all as specified and directed |
| 92 | Supply and fix in repair fuel steel braided pipe with benjo bolt and washers etc complete of length 45 to 60cm long complete all as specified and directed |
| 93 | Supply and fix in repair control wiring of the DG set up to 160 KVA complete incl provision of additional auto cables heavy duty suitable for Gen set application complete all as specified and directed |
| 94 | Supply and fix in repair control wiring of the DG set above 320KVA up to 437.5 KVA complete incl provision of additional auto cables heavy duty suitable for Gen set application complete all as specified and directed |
| 95 | Supply and fix in repair pressure guage 0 to 7 Kg/sqcm along with sensor and cable and complete all as specified and directed. |
| 96 | Supply and fix in repair lead acid battery 12 Volts 180 AH with initial charging and having indicators to know the status of level of electrolyte complete all as specified and directed. |
| 97 | Supply and fix in repair lead acid battery 12 Volts 150 AH with initial charging and having indicators to know the status of level of electrolyte complete all as specified and directed. |
| 98 | M & L for Top Overhauling only of DG set of followingcapacity of any make and including replacement of all spare parts required to complete all as specified and directed. |
| 99 | (a) D. G . Set 15 to 20 KVA |
| 100 | (b) D. G . Set 30 to 62.5 KVA |
| 101 | (c)D. G . Set 160 KVA |
| 102 | (d)D. G . Set 320 KVA |
| 103 | (e) D. G . Set 437.5 KVA |
| 104 | Supply only Oil Sump packing set suitable for following DG sets complete all as specified and directed. |
| 105 | (a) D. G . Set 15 to 20 KVA |
| 106 | (b) D. G . Set 30 to 62.5 KVA |
| 107 | (c)D. G . Set 160 KVA |
| 108 | (d)D. G . Set 320 KVA |
| 109 | (e) D. G . Set 437.5 KVA |
| 110 | Supply and fix in repair soleinoid valve suitable for following capacity DG sets for smooth functioningcomplete all as specified and directed. |
| 111 | (a) D. G . Set 15 to 20 KVA |
| 112 | (b) D. G . Set 30 to 62.5 KVA |
| 113 | (c)D. G . Set 160 KVA |
| 114 | (d)D. G . Set 320 KVA |
| 115 | (e) D. G . Set 437.5 KVA |
| 116 | Supply and fix microprocessor based multifunction relay suitable for DG sets operation and showing the various parameters such as Volt, ampere, frequency, rpm etc as per existing make and sample suitable for upto 62.5 KVA DG sets etc complete all as specified and directed. |
| 117 | Supply and fix microprocessor based multifunction relay suitable for DG sets operation and showing the various parameters such as Volt, ampere, frequency, rpm etc as per existing suitable for 160 KVA DG sets etc complete all as specified and directed. |
| 118 | Supply and fix microprocessor based multifunction relay suitable for DG sets operation and showing the various parameters such as Volt, ampere, frequency, rpm etcas per existing suitable for 320 KVA DG sets etc complete all as specified and directed. |
| 119 | Supply and fix microprocessor based multifunction relay suitable for DG sets operation and showing the various parameters such as Volt, ampere, frequency, rpm etcas per existing suitable for 437.5 KVA DG sets etc complete all as specified and directed. |
| 120 | Supply and fix in repairs battery terminal made out of brass/bronze heavy duty suitable for 150 AH/180 AH 12 Volt Battery complete all as specified and directed. |
| 121 | S&F in repair self starter for engine of DG Set upto 100 KVAof existing make complete with all connections and all accessories including all fitting all as spd and directed by engrs in charge. |
| 122 | S&F in repair self starter for engine of DG Set 160KVAof existing make complete with all connections and all accessories including all fitting all as spd and directed by engrs in charge. |
| 123 | S&F in repair self starter for engine of DG Set 320KVAof existing make complete with all connections and all accessories including all fitting complete all as specified and directed. |
| 124 | S&F in repair self starter for engine of DG Set 437.5KVAof existing make complete with all connections and all accessories including all fitting complete all as specified and directed. |
| 125 | M&L for repair to AMF panel of DG set 15 KVA to 62.5 KVA including replacement ofwiring of interlock system of AMF panel with suitable size of copper wiring including proper connection and testing complete all as specified and directed. |
| 126 | M&L for repair to AMF panel of DG set 100 KVA to 160 KVA including replacement ofwiring of interlock system of AMF panel with suitable size of copper wiring including proper connection and testing. complete all as specified and directed. |
| 127 | M&L for repair to AMF panel of DG set 320 KVA to 437.5 KVA including replacement ofwiring of interlock system of AMF panel with suitable size of copper wiring including proper connection and testing complete all as specified and directed. |
| 128 | Supply and Fix in replacement of Electronic timer suitable for AMF panel of DG set upto 100 KVA as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed. |
| 129 | Supply and Fix in replacement of Electronic timer suitable for AMF panel of DG set 160 KVA as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed. |
| 130 | Supply and Fix in replacement of Electronic timer suitable for AMF panel of DG set 320 KVA as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed. |
| 131 | Supply and Fix in replacement of Electronic timer suitable for AMF panel of DG set 437.5 KVA as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed. |
| 132 | Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifoldfor DG sets 15 to 62.5 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed. |
| 133 | Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifoldfor DG sets 82.5 KVA to 160 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed. |
| 134 | Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifoldfor DG set 320 KVA to 437.5 KVAincludung removing of existing asbestos rope or any other type of insulation complete all as specified and directed. |
| 135 | Dismantling the fuel pump from the Engine of capacity 15 to 20 KVA ,transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve,plunger,copper washer etc all as required including re-calibration,refixing and testing complete all as specified and directed. |
| 136 | Dismantling the fuel pump from the Engine of capacity 62.5 to 100 KVA ,transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve,plunger,copper washer etc all as required including re-calibration,refixing and testing complete all as specified and directed. |
| 137 | Dismantling the fuel pump from the Engine of capacity 160 KVA ,transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve,plunger,copper washer etc all as required including re-calibration,refixing and testing complete all as specified and directed. |
| 138 | Dismantling the fuel pump from the Engine of capacity 320 to 437.5 KVA ,transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve,plunger,copper washer etc all as required including re-calibration,refixing and testing complete all as specified and directed. |
| 139 | Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 15 to 20 KVA complete all as specified and directed. |
| 140 | Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 62.5 to100 KVA complete all as specified and directed. |
| 141 | Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 160 KVA complete all as specified and directed. |
| 142 | Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 320 KVA. |
| 143 | Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 437.5 KVA complete all as specified and directed. |
| 144 | Replacement of turbo chargers repairs kit suitable for DG set 62.5 to 100 KVA complete all as specified and directed. |
| 145 | Replacement of turbo chargers repairs kit suitable for DG set 160 KVA complete all as specified and directed. |
| 146 | Replacement of turbo chargers repairs kit suitable for DG set 320 KVA to 437.5 KVA complete all as specified and directed. |
| 147 | Materials and labour for B checkby authorised rep of manufacturer of DG set ofcap 437.5 KVA including replacement of oil filter, fuel filter, air filter after draining out engine/lubricant oil flushing and cleaning of oil chamber after opening of tappet cover/top cover tappet cleaning setting with injector timing adjustment refixing of tappet/top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/chamber gasket at the servicing and other work comes under B check complete all as specified and directed.Note: Engine oil will be paid separately. |
| 148 | Materials and labour for B checkby authorised rep of manufacturer of DG set ofcap 320 KVA including replacement of oil filter, fuel filter, air filter after draining out engine/lubricant oil flushing and cleaning of oil chamber after opening of tappet cover/top cover tappet cleaning setting with injector timing adjustment refixing of tappet/top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/chamber gasket at the servicing and other work comes under B check complete all as specified and directed. Note: Engine oil will be paid separately. |
| 149 | Materials and labour for B checkby authorised rep of manufacturer of DG set ofcap 160 KVA including replacement of oil filter, fuel filter, air filter after draining out engine/lubricant oil flushing and cleaning of oil chamber after opening of tappet cover/top cover tappet cleaning setting with injector timing adjustment refixing of tappet/top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/chamber gasket at the servicing and other work comes under B check all as specified as directed. Note: Engine oil will be paid separately. |
| 150 | Materials and labour for B checkby authorised rep of manufacturer of DG set of capacity 15 KVA to 100 KVA including replacement of oil filter, fuel filter, air filter after draining out engine/lubricant oil flushing and cleaning of oil chamber after opening of tappet cover/top cover tappet cleaning setting with injector timing adjustment refixing of tappet/top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/chamber gasket at the servicing and other work comes under B check all as specified as directed. Note: Engine oil will be paid separately. |
| 151 | Supply and fixing of ON load change over switch 440 volts 4 pole of rating 400 amps with encloser fixed on wall/ panel including nut/bolts/washers complete all as specified and directed. |
| 152 | Servicing /Caliberation / Repairs toAir Circuit Breaker 800 to 1600 Amps by OEM of ACB only for EDO ( Electrically Draw Out) type/ MDO type(Mannually Draw out type)/ Fixed type. Taking out any type of ACBfor servicing / repair and checking / caliberation ofmicroprocessor release,Earth fault protection of 4 pole, 50 KA breaking capacity 415 volts with all draw out type mechanism, advanced self powered electronic protection units, neutral overload protection, automatic earth fault relay / over current relay , automatic safety shutter, inbuilt temperature protection, icu=ics=icw(1s)=50 KAfixed in panel complete including relay wiring checking ,LT UG cable connection with main incoming ACB complete connection for its healthy functioningall as directed by Engr in charge. Note- Certificate of Servicing /Caliberation will be provided by the contractor free of cost. |
| 153 | Supply & fix in repair protection releases for air circuit breakerssuitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed. |
| 154 | Supply & fix in repair earth fault realease for air circuit breakerssuitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed. |
| 155 | Supply & fix in repair shunt release for air circuit breakers suitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed. |
| 156 | Supply & fix in repair under voltage realease for air circuit breakerssuitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed. |
| 157 | Supply & fix in repair lockable trip push button for air circuit breakerssuitable for existing breakers as per site make / requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed. |
| 158 | Supply and Fix in replacement of selector switch suitable for voltmeter and Ammeter complete all as specified and directed. |
| 159 | Supply and Fixin replacement of under voltage relay suitable for DG set of capacity 62.5 KVA to 160 KVA complete all as specified and directed. |
| 160 | Supply and Fixin replacement of under voltage relay suitable for DG set of capacity 320 to 437.5 KVA complete all as specified and directed. |
| 161 | Attending the fault in APFC panel including repairing of APFC relay, Contactor of any make/capacity, digital lamp,switch and setting the APFC panel relay OEM for proper function, testing connection of capacitor bank of any capacity including replacing small parts below Rs 500/- repairing and blowing out dust from inside the APFC panelcomplete all as specified and directed. |
| 162 | S&F in repair APFC controller 8 step for automatic correction of power factor suitable for 415 volt 3 phase power supply complete with necessary fixing complete as directed by Engr-in-charge. |
| 163 | Supply and Fix in repairs digital voltmeter 0-500 volts square type complete with necessary fixing and 3 nos of CTs all as specified and as directed by Engr-in-charge. |
| 164 | Supply and Fix in repairs digital ammeter 0-400 amps square type complete with necessary fixing and 3 nos of CTs 400/5 A all as specified and as directed by Engr-in-charge. |
| 165 | S&F in repair Capacitor duty Contactors suitable for upto 10 KVAR capacitor bank complete all as specified and directed by Engineer-in-Charge. |
| 166 | S&F in repair Capacitor duty Contactors suitable for upto 25 KVAR capacitor bank complete all as specified and directed by Engineer-in-Charge. |
| 167 | S&F in replacement of PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100V grade complete all as specified and as directed. |
| 168 | S&F in replacement of PVC insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmm complete all all as specified and directed. |
| 169 | S&F in repair jointing kit for 1.1 KV ( earthed) grade cable indoor type for end termination, heat shrinkable of size 120 Sqmmto 300 Sqmm conforming to IS - 7098 part-II including thimbling, nut/bolts & washers etc, complete all as specified and directed. |
| 170 | S&F in repair straight through joint1.1 KV heat shrinkable of size upto 120 Sqmmto 185 Sqmmconforming to IS - 7098 part-II including thimbling, nut/bolts & washers etc, complete all as specified and directed. |
| 171 | S&F in repair straight through joint1.1 KV heat shrinkable of size 240 Sqmm to 300 Sqmm conforming to IS - 7098 part-II including thimbling, nut/bolts & washers etc, complete all as specified and directed. |
| 172 | S&F in repair straight through joint1.1 KV heat shrinkable of size 400 Sqmm to 630 Sqmm conforming to IS - 7098 part-II including thimbling, nut/bolts & washers etc, complete all as specified and directed. |
| 173 | S&F in repairIP-43, protection metal double door Vertical TPN -DB rated busbar, 415 volts, 50 HZ completewith interconnection links, blanking plates, cable ties, identification labelsTPN4 way,12 modules suitable for accommodating 100 AmpsMCCB 4 pole as incomer and SP/TP MCB as out going and concealed /surface on wall as per site requirement including all cutting holes in or throughwalls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing. Note- MCCB 100 Amps 4 pole 16 KA as incomer will be measured seprately in relevant item.. |
| 174 | S&F in repair IP-43, protection metal double door Vertical TPN -DB rated busbar, 415 volts, 50 HZ completewith interconnection links, blanking plates, cable ties, identification labelsTPN8 way,24 modules suitable for accommodating 100 AmpsMCCB 4 pole as incomer and SP/TP MCB as out going and concealed /surface on wall as per site requirementincluding all cutting holes in or throughwalls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified and directed.Note- MCCB 100 Amps 4 pole 16 KA as incomer will be measured seprately in relevant item.. |
| 175 | S&F inrepair, IP-43,MCB DB 8 way, double door, with 100 amp rated busbar 240 V, SPN concealed / surface on wall as directed by Engr in charge including all cutting holes in or throughwalls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified and directed. |
| 176 | S&F in replacement for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of sizewith 10 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirmingto IS: 694-1990 with and including continuous earth wire of size 1x10 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour Caping Casing and its accessariesISI marked of suitable size concealed in wall / on surface as per site requirement etcand connected to common earth dolly including all cutting / chases etc in any type of wall , making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed.(Note:-One meter of conduit along with 4x10 sq mm wire and 1x10 sq mm earth shall be measured as one unit length.) |
| 177 | S&F in replacement for submain wiring including PVC casing capping 2 run 4 Sqmm cable PVC insulated copper conductor multi - stranded as per FRLS cable drawn throughPVC non metallic rigid heavy duty PVC conduit of white/ ivory colour / Caping Casing and its accessariesISI marked of suitable size concealed in wall / on surface as per site requirement etc with all accessories including 4 Sqmm single strand copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly and complete all as specified and directed. |
| 178 | M & L forEarthing completewith Copper earth plate electrode \"60cm × 60cm × 3 mm thick, buried \"directly in ground (earth pit not less \"than 2.25 metres deep below normalground \"level) with top edge of the plate not \"less than 1.5 metres below normal ground level\", connected to \"Copper strip 20x3 mm by means of bolts, nuts, check \"nuts and washers of copper earth strip protected by provision of GI \"medium grade\" pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B1 (using 20mm graded stone aggregate) with 40mm thickcover in RCC (1:2:4) type B-1 reinforced with XPM (weight not less than 4 kg/sqm) and frame made outin MS angle iron of size25x25x3mm with lugs02 Nos and withMShandle made in 6mm dia round bar made to shape, including GI \"medium grade\" 20mm bore pipe for watering, perforated at bottom1.75m long placed on top edge of earth plate including including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, test point made out of Phosphorus bronze with fixing arrangement ,funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exceeding 50mtr all as shown in electrical plateconnected to earthing test point all as specified or indicated \"including testing on completion.NOTE:-Copper strip and GI pipe 40 mm bore medium grade for encasing Copper strip upto 7.50m lengthper earthing shall be deemed to be included in the unit rate. |
| 179 | Providing and fixing in replacement of20mm x 3 mmcopper strip in 40 mm dia GI pipe from earth electrode including connection with brass nut bolt spring washer excavation and re-filling etc as required strip on surface or in recess for connections etc as required. |
| 180 | S&F in repair,Triple pole and earth enclosure 415 V with a three pin and earth plug with socket complete with one triple pole 32 AmpsMCB TP concealed / surface on wall as per site requirement including all cutting holes in or throughwalls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified and directed. |
| 181 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6 galvanized iron strip, including taking out old unserviceable strip complete all as specified and directed. |
| 182 | M & L forEarthing complete (Generator, Transformer, lightning arrestor and feeder pillar box) with galvanised steel earth plate electrode \"60cm × 60cm × 6mm thick, buried \"directly in ground (earth pit not less \"than 2.25 metres deep below normalground \"level) with top edge of the plate not \"less than 1.5 metres below normal ground level\", connected to \"galvanisediron strip 32x6mm by means of bolts, nuts, check \"nuts and washers of galvanised iron or steel earth strip protected by provision of GI \"medium grade\" pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B1 (using 20mm graded stone aggregate) with 40mm thickcover in RCC (1:2:4) type B-1 reinforced with XPM (weight not less than 4 kg/sqm) and frame made outin MS angle iron of size25x25x3mm with lugs02 Nos and withMShandle made in 6mm dia round bar made to shape, including GI \"medium grade\" 20mm bore pipe for watering, perforated at bottom1.75m long placed on top edge of earth plate including including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, test point made out of ohosphorus bronze with fixing arrangement ,funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exceeding 50mtr all as shown in electrical plate No. 3 of SSR Part I 2009connected to earthing test point all as specified or indicated \"including testing on completion.NOTE:-GI strip and GI pipe 40mm bore medium grade for encasing GI strip upto 7.50m lengthper earthing shall be deemed to be included in the unit rate complete all as specified and directed. |
| 183 | Supply,laying,testing and commissionnig ofLT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel/ MCCBin bldg etc to suit the cablelaid in trenches/fixed to poles/drawn through pipes complete ofsizes 400 Sqmm 3.5 core including taking out old unserviceable cablecomplete all as specified and directed. |
| 184 | Supply,laying,testing and commissionnig ofLT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel/ MCCBin bldg etc to suit the cablelaid in trenches/fixed to poles/drawn through pipes complete ofsizes 240 Sqmm 3.5 core including taking out old unserviceable cablecomplete all as specified and directed. |
| 185 | Supply,laying,testing and commissionnig ofLT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel/ MCCBin bldg etc to suit the cablelaid in trenches/fixed to poles/drawn through pipes complete ofsizes 120 Sqmm 3.5 coreincluding taking out old unserviceable cablecomplete all as specified and directed. |
| 186 | Supply,laying,testing and commissionnig ofLT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel/ MCCBin bldg etc to suit the cablelaid in trenches/fixed to poles/drawn through pipes complete ofsizes 70 Sqmm 3.5 coreincluding taking out old unserviceable cable complete all as specified and directed. |
| 187 | Supply,laying,testing and commissionnig ofLT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel/ MCCBin bldg etc to suit the cablelaid in trenches/fixed to poles/drawn through pipes complete ofsizes 35 Sqmm 3.5 coreincluding taking out old unserviceable cablecomplete all as specified and directed. |
| 188 | Supply,laying,testing and commissionnig ofLT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel/ MCCBin bldg etc to suit the cablelaid in trenches/fixed to poles/drawn through pipes complete ofsizes 16 Sqmm 4 coreincluding taking out old unserviceable cablecomplete all as specified and directed. |
| 189 | Supply and laying 80mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of under ground cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with suitable clamps, bolt/nuts etcfor fixing on walls, poles etcincluding taking out old unserviceable pipe complete all as specified and directed. |
| 190 | Supply and laying 50mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of under ground cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with suitable clamps, bolt/nuts etcfor fixing on walls, poles etc including taking out old unserviceable pipe complete all as specified and directed. |
| 191 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables etc. and getting out in the following type of strata complete all as specified and directed. |
| 192 | (a) Soft/Loose soil |
| 193 | (b) Hard/ Dense soil |
| 194 | (c) Soft/disintegrated Rock |
| 195 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 196 | Removal of excavated material [soil] to a distance not Exc 50m and depositing where directed at a level not exc 1.5m above the starting point where directed complete all as specified and directed. |
| 197 | M&L for laying reinforced concrete pipes, class NP2 of dia 100 mm, 2 nos half round (for bottom and top) and before laying excavated area shall be levelling complete all as specified and directed. |
| 198 | S&F MCB, SP 20- 32 Amps,10 KA ,230 V, \"C\"series in replacement of old damage/broken MCB SP complete all as specified and directed. |
| 199 | S&F MCB, SPN, 40 Amps,10 KA ,230 V, \"C\"series in replacement of old damage/broken MCB SPN complete all as specified and directed. |
| 200 | S & FMCB TPN, 415 Volts, 40 Amps,10 KA ,230 V, \"C\"seriesin replacement of old unserviceable MCB complete all as specified and directed. |
| 201 | S & FMCB TPN, 415 Volts, 63 Amps,10 KA ,230 V, \"C\"series in replacement of old unserviceable MCB complete all as specified and directed. |
| 202 | Supply and fix MCB TP 63 Amps, 415 volts in replacement of old unserviceable MCB complete all as specified and directed. |
| 203 | Supply and fix MCB TP 40 Amps, 415 volts in replacement of old unserviceable MCB complete all as specified and directed. |
| 204 | Supply and Fix in replacement of MCCB 63 Amps to 100 Amps,16 KA, 4 Pole, 415V complete all as specified and directed. |
| 205 | Supply and Fix in replacement of MCCB 160 Amps, 36 KA, 4 Pole, 415V complete all as specified and directed. |
| 206 | Supply and Fix in replacement of MCCB 200 Amps, 36 KA, 4 Pole, 415V complete all as specified and directed. |
| 207 | Supply and Fix in replacement of MCCB 250 Amps, 36 KA, 4 Pole, 415V complete all as specified and directed. |
| 208 | Supply and Fix in replacement of MCCB 400 Amps, 36 KA, 4 Pole, 415V complete all as specified and directed. |
| 209 | Supply and Fix in replacement of MCCB 630 Amps, 50 KA, 4 Pole, 415V complete all as specified and directed. |
| 210 | Excavating in post holes soft/loose soil (or similr holes) not exc 0.5 Cum getting out returning filling in and rammingearth or broken rubblemixed with earth around, in layers not exceeding 25 CM watering and removing surplus soil to a distanceno exc 50m and making good surfaces |
| 211 | M&L 100 mm thickPCC type D-2 1:4:8 (40 mm graded aggregate ) as in sub base of floor complete all as specified and directed. |
| 212 | M&L for cement concrete 1:2:4 type B2(40 mm graded aggregate) in foundations filling and mass Concrete complete all as specified and directed. |
| 213 | M&L for rolled mild steel as in joint, channel, angle, or Tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths I.e. within 20 mm of the length indicated) of GDE Fe 410-S,complete all as specified and directed. |
| 214 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail