| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 2 | All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge |
| 4 | All kinds of soil |
| 5 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
| 6 | All kinds of soil |
| 7 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 8 | Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). |
| 9 | Depth not exceeding 1.5 m |
| 10 | Depth exceeding 1.5 m but not exceeding 3 m |
| 11 | Open timbering in case of shafts, wells, cesspits, manholes and the like including strutting and shoring complete (Measurements to be taken of the face area timbered): |
| 12 | Depth not exceeding 1.5 m |
| 13 | Depth exceeding 1.5 m but not exceeding 3 m |
| 14 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 15 | Surface dressing of the ground including removing vegetation and in equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 16 | All kinds of soil |
| 17 | Supplying chemical emulsion in sealed containers including delivery as specified. |
| 18 | Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 19 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 20 | Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: |
| 21 | With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 22 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: |
| 23 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 24 | Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : |
| 25 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 26 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal sizeerived from natural sources). |
| 27 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer\"s specification. |
| 28 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 29 | Extra for concrete work in superstructure above floor V level for each four floors or part thereof by mechnical means. |
| 30 | Extra for addition of synthetic Polyester triangular fibre of length 12mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement concrete/RCC/Flooring/water retaining structures by using 125 gram of synthetic Polyester triangular fibre for 50 kg cement used as per direction of Engineer-in-Charge. |
| 31 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -All work up to plinth level : |
| 32 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-Ill} derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 33 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to f loor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 34 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 35 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregae 20 mm nominal size derived from natural sources). |
| 36 | Providing and laying reinforced cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering, f inishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 37 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 38 | Foundations, footings, bases of columns, etc. for mass concrete |
| 39 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 40 | Suspended floors, roofs, landings, balconies and access platform |
| 41 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 42 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 43 | Stairs, (excluding landings) except spiral-staircases |
| 44 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 45 | Edges of slabs and breaks in floors and walls |
| 46 | Under 20 cm wide |
| 47 | Above 20 cm wide |
| 48 | Weather shed, Chajjas, corbels etc., including edges |
| 49 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). |
| 50 | Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) |
| 51 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 52 | Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to f loor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 53 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 54 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 55 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 56 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 57 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). |
| 58 | Extra for rendering smooth the top of suspended floors, landings and staircases (treads and risers) with cement mortar 1:2 (1 cement : 2 coarse sand), including a floating coat of neat cement and protecting the surface with a layer of 7.5 cm of earth laid over 15 mm of fine sand in case of suspended floor and bricks laid in mud mortar in case of landings and steps, including subsequent removal and cleaning of the same |
| 59 | Providing and fixing sheet covering over expansion joints with iron screws as per design. |
| 60 | Aluminium fluted strips 3.15 mm thick. |
| 61 | 200 mm wide |
| 62 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 63 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 64 | All works upto plinth level |
| 65 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 66 | All works above plinth level upto floor V level |
| 67 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 68 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 69 | Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. |
| 70 | Supplying and applying pre tested and approved water based concrete curing compound to concrete/ masonry surface, all as per manufacturer’s specification and direction of Engineer-in-charge. |
| 71 | Non pigmented wet curing compound |
| 72 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 73 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 74 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 75 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 76 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 77 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 78 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : |
| 79 | Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 80 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor Vlevel |
| 81 | Cement mortar 1:3 (1 cement :3 coarse sand) |
| 82 | Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means. |
| 83 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry |
| 84 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. Complete at all levels. |
| 85 | Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble |
| 86 | Area of slab over 0.50 Sqm |
| 87 | Granite stone slab of colour black, Cherry/Ruby red |
| 88 | Area of slab over 0.50 Sqm |
| 89 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 90 | Marble work |
| 91 | Granite work |
| 92 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 93 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 94 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of anysize as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, includingpointing in white cement mixed with pigment of matching shade complete |
| 95 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 96 | Second class teak wood |
| 97 | 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT- I or graded wood particle board FPT- I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS : 12823, Grade 1, Type - II marked. |
| 98 | Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) |
| 99 | 5.0 mm thick (weight not less than 12.50 kg per sqm) instead of 4 mm thick (weight not less than 10 kg per sqm). |
| 100 | Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick (weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 101 | Deduct for providing pin headed glass panes instead of ordinary float glass panes 4 mm thick (weight not less than 10 kg per sqm) in doors, windows and clerestory windows shutters (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 102 | Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). |
| 103 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 104 | 25 mm thick (for cupboard) including ISi marked nickel plated bright finished M.S. piano hinges with necessary screws |
| 105 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of doorshutter to be measured). |
| 106 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): |
| 107 | Rectangular or square |
| 108 | Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured). |
| 109 | Decorative type door |
| 110 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws |
| 111 | 35 mm thick shutters |
| 112 | With ISI marked stainless steel butt hinges of required size |
| 113 | Second class teak wood |
| 114 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete |
| 115 | Fixed to steel windows by welding |
| 116 | Providing and fixing ISi marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete (Copper oxidised as per IS 1378 |
| 117 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete |
| 118 | 125x64x1.90 mm |
| 119 | 100X58X1.90 mm |
| 120 | 75x47x1.80 mm |
| 121 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete |
| 122 | 100 mm |
| 123 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture\"s specification and direction of engineer in charge all complete. |
| 124 | 75 mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks) |
| 125 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge |
| 126 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge |
| 127 | Extruded section profile size 48x40 mm |
| 128 | Extruded section profile size 42x50 mm |
| 129 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). |
| 130 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled FR insulation material and f ixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). |
| 131 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. |
| 132 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1. 70 mm for Series R 1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Note:- Structural design proof checked from a GovernmentEngineering Institute, to be provided by the manufacturer for(i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3(ii) Sites with structure height more than 20m for all wind speeds |
| 133 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body |
| 134 | Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 etre). |
| 135 | Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). |
| 136 | Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multipoint locking system. (Height above 1.8m) |
| 137 | Fixed window/ ventilator without mullion/ transom. |
| 138 | Using R1 series with frame (33 mm & above) x (35 mm & above). (Height upto 0.90 metre) |
| 139 | Using R2 series with frame (39 mm & above) x (39 mm & above). (Height upto 1.2 metre) |
| 140 | Using R3 series with frame (55 mm & above) x (45 mm & above). (Height upto 2.5 metre) |
| 141 | Using R4 series with frame (64 mm & above) x (50 mm & above). (Height above 2.5 metre) |
| 142 | Fixed window/ ventilator with mullion / transom |
| 143 | Using R 1 series with frame (33 mm & above ) x (35 mm & above) & mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre) |
| 144 | Using R2 series with frame (39 mm & above ) x (39 mm & above) & mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre) |
| 145 | Using R3 series with frame (55 mm & above ) x (45 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 2.5 metre |
| 146 | Using R4 series with frame (64 mm & above ) x (50 mm & above) & mullion (64 mm & above) x (70 mm & above). (Height above 2.5 metre) |
| 147 | Ventilator Casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zamak) powder coated handles. |
| 148 | Using R1 series with frame (33 mm & above) x (35 mm & above) & sash /mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre). |
| 149 | Using R2 series with frame (39 mm & above) x (39 mm & above) & sash /mullion (39 mm & above) x (60 mm & above). (Height upto 1.2metre) |
| 150 | Using R3 series with frame (55 mm & above) x (45 mm & above) & sash /mullion (55 mm & above) x (65 mm & above). (Height above 1.2 metre) |
| 151 | Casement window single panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system zinc alloy (zamak) powder coated handles. |
| 152 | Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above). Height upto 1.2 metre) |
| 153 | Using R3 series with frame (55 mm & above ) x (45 mm & above) & sash (55 mm & above) x (65 mm & above). (Height upto 1.8 metre |
| 154 | Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above). (Height above 1.8 metre) |
| 155 | Casement window double panels with fixed mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles |
| 156 | Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre). |
| 157 | Using R3 series with frame (55 mm & above) x (45 mm & above) & sash (55 mm & above) x (65 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 1.8 metre). |
| 158 | Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above) & mullion (64 mm & above) x (70 mm & above). (Height above 1.8 metre) |
| 159 | Casement window double panels with French (False) Mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles |
| 160 | Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & French (False) mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre). |
| 161 | Using R3 series with frame (55 mm & above) x (45 mm & above) & sash (55 mm & above) x (65 mm & above) & French (False) mullion (55 mm & above) x (60 mm & above). (Height upto 1.8 metre). |
| 162 | Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above) & French (False) mullion (64 mm & above) x (60 mm & above). (Height above 1.8 metre). |
| 163 | Casement cum fixed panel window having one single casement panel & one fixed panel with S.S 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles |
| 164 | Using R2 series with frame (39 mm & above ) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & mullion (39 mm & above)x (60 mm & above). (Height upto 1.2 metre; Each openable shutter upto 0.8m width) |
| 165 | Using R3 series with frame (55 mm & above ) x (45 mm & above) & sash (55 mm & above) x (65 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 1.8 metre; Each openable shutter upto 0.8m width) |
| 166 | Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above) & mullion (64 mm & above) x (70 mm & above). (Height above 1.8 metre; Each openable shutter upto 0.8m width) |
| 167 | Casement cum fixed panel window having single casement panel at both ends & middle fixed panel with S.S 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. |
| 168 | Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre; Each openable shutter upto 0.8m width) |
| 169 | Using R3 series with frame (55 mm & above) x (45 mm & above) & sash (55 mm & above) x (65 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 1.8 metre; Each openable shutter upto 0.8m width) |
| 170 | Using R4 series with frame (64 mm & above ) x (50 mm & above) & sash (64 mm & above) x (70 mm & above) & mullion (64 mm & above) x (70 mm & above). (Height above 1.8 metre; Each openable shutter upto 0.8m width) |
| 171 | Casement Window with Double Rebate Frame with one Side Hung Glazed Panel and one Side Hung wire mesh Panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles on both glazed and fly screen panel |
| 172 | Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm & above) x (65 mm & above) & fly screen sash (30 mm & above) x (55 mm & above) & metal grill (if required to be paid separately). (Height upto 1.8 metre) |
| 173 | Casement Window with Double Rebate Frame with two Side Hung Glazed Panel and two Side Hung wire mesh Pane and Fixed Mullion with S.S. 304 friction hinges as per siez and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles on both glazed and fly screen panel. |
| 174 | Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm & above) x (65 mm & above) & fly screen sash (30 mm & above) x (55 mm & above) & mullion (55 mm & above) x (65 mm & above) & metal grill (if required to be paid separately). (Height upto 1.8 metre |
| 175 | Casement Window with Double Rebate Frame with two Side Hung Glazed Panel on outside and two Side Hung wire mesh Panel on inside and French (False) Mullion with S.S. 304 friction hinges as per size and weight of sash, multipoint locking system, zinc alloy (zamak) powder coated handles with shoot bolt on both glazed and fly screen panel |
| 176 | Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm &above) x (65 mm & above) & fly screen sash(30 mm & above) x (55 mm & above) & French(False) mullion (55 mm & above) x (60 mm& above) & metal grill (if required to be paid separately). (Height upto 1.8 metre). |
| 177 | Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides. |
| 178 | Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) (Height upto 2.5 metre |
| 179 | Using R4 series with frame (64 mm & above) x (55 mm & above) & sash (64 mm & above) x (100 mm & above). (Height above 2.5 metre). |
| 180 | Casement door double panel with French (False) Mullion with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides. |
| 181 | Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) & French (False) mullion (55 mm & above) x (60 mm & above). (Height upto 2.5 metre). |
| 182 | Using R4 series with frame (64 mm & above) x (55 mm & above) & sash (64 mm & above) x (100 mm & above) & French (False) mullion (64 mm & above) x (60 mm & above). (Height above 2.5 metre). |
| 183 | Casement Door with Double Rebate Frame with one Side Hung Glazed Panel and one Side Hung wire mesh Panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides of glazed panel and zinc alloy (Zamak) powder coated handle along with multi-point locking system on one side of fly screen panel. |
| 184 | Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm & above) x (85 mm & above) & fly screen sash (55 mm & above) x (65 mm & above). (Height upto 2.5 metre). |
| 185 | Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge. |
| 186 | 200 x 19 x 1.9 mm |
| 187 | 250 x 19 x 1.9 mm |
| 188 | 300 x 19 x 1.9 mm |
| 189 | 350 x 19 x 1.9 mm |
| 190 | 400 x 19 x 1.9 mm |
| 191 | Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete. |
| 192 | Providing and fixing zinc alloyed (white powder coated) touch lock for \uPVC sliding window with necessary screws etc. complete |
| 193 | Providing and fixing steel roller for uPVC sliding window with necessary screws etc. complete. |
| 194 | Providing and fixing steel roller for uPVC sliding door with necessary screws etc. complete |
| 195 | Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete. |
| 196 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. |
| 197 | 125 mm |
| 198 | 100mm |
| 199 | 75 mm |
| 200 | 12 mm cement plaster on the rough side of single or half brick wall of mix : |
| 201 | 1:4 (1 cement: 4 fine sand) |
| 202 | 1:6 (1 cement: 6 fine sand) |
| 203 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 204 | 1:4 (1 cement: 4 fine sand) |
| 205 | 1:6 (1 cement: 6 fine sand) |
| 206 | 6 mm cement plaster of mix : |
| 207 | 1:3 (1 cement : 3 fine sand) |
| 208 | Neat cement punning. |
| 209 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : |
| 210 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 211 | Finishing walls with water proofing cement paint of required shade : |
| 212 | New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 213 | Finishing walls with textured exterior paint of required shade : |
| 214 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 215 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 216 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 217 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 218 | Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 219 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 220 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 221 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete |
| 222 | On steel work |
| 223 | On concrete work |
| 224 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. |
| 225 | 100 mm diameter pipes |
| 226 | 150 mm diameter pipes |
| 227 | Paintting with oil type wood preservative of approved brand and manufacture: |
| 228 | New work (two or more coats) |
| 229 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 230 | Two or more coats on new work |
| 231 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 232 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour |
| 233 | Old work (one or more coats) |
| 234 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour |
| 235 | One coat |
| 236 | Two coats |
| 237 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 238 | With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre |
| 239 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 240 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 241 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade |
| 242 | One or more coats on old work |
| 243 | Finishing walls with water proofing cement paint of required shade : |
| 244 | Old work (one or more coats @ 2.20 kg/10 sqm) complete. |
| 245 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 246 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 247 | Old work (One or more coat applied @ 0.90 ltr/10 sqm). |
| 248 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge |
| 249 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 250 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 251 | Door chowkhats . |
| 252 | Clerestory window chowkhats . |
| 253 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface including disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge |
| 254 | For door/ window/ clerestory window |
| 255 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 256 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/Sqm) |
| 257 | Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/Sqm) |
| 258 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge |
| 259 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall |
| 260 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge |
| 261 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 262 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 263 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 264 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge |
| 265 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 266 | Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work. |
| 267 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 268 | In cement mortar |
| 269 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): |
| 270 | From brick work in cement mortar |
| 271 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 272 | Of area 3 sq. metres and below |
| 273 | Of area beyond 3 sq. metres |
| 274 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead |
| 275 | Of area 3 sq. metres and below |
| 276 | Of area beyond 3 sq. metres |
| 277 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 278 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge |
| 279 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 280 | For thickness of tiles 10 mm to 25 mm |
| 281 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 282 | Demolishing mud phaska in terracing and disposal of material within 50 metres lead. |
| 283 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 284 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 285 | 100 mm dia pipe |
| 286 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 287 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineerin-charge. |
| 288 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 289 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc |
| 290 | 15 mm nominaldia .Pipes. |
| 291 | 20 mm nominaldia .Pipes. |
| 292 | 25 mm nominaldia .Pipes. |
| 293 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed echanicallywherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 294 | For fixed portion |
| 295 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 296 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 297 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 298 | Powder coated aluminium (minimum thickness of powder coating 50 micron |
| 299 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge |
| 300 | Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 301 | Pre-laminated particle board with decorative lamination on both sides |
| 302 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): |
| 303 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/Sqm) |
| 304 | With float glass panes of 8 mm thickness (weight not less than 20 kg/Sqm) |
| 305 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in- charge. |
| 306 | With stainless steel cover plate minimum 1.25 mm thickness |
| 307 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete |
| 308 | Anodized (AC 15) aluminium |
| 309 | Powder coated minimum thickness 50 micron aluminium |
| 310 | Polyester powder coated minimum thickness 50 micron aluminium |
| 311 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 312 | Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/ structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 |
| 313 | Upto 5 mm depth and 5 mm width |
| 314 | Upto 10 mm depth and 10 mm width |
| 315 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and f inally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: |
| 316 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 317 | Grading roof for water proofing treatment with |
| 318 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 319 | Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 320 | Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge. |
| 321 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying (a) First layer of slurry of cement @ 0.488 kg/Sqm mixed with water proofing cement compound @ 0.253 kg/ Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 322 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 323 | Bars upto 12 mm diameter |
| 324 | Bars above 12 mm diameter |
| 325 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm upto 200 mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. |
| 326 | Upto and including 12 mm dia. |
| 327 | Water proofing treatment of Vertical joints (of external side and internal side) between door frame, window & ventilator frames (on all four sides) of outer wall over the Zycosil/equivalent & Zycoprime/equivalent solution already applied (before the installation of door / window / ventilator frames in position) and fine finish with Grout RW/equivalent. |
| 328 | Water proofing treatment of RCC sunshade with Zycosil/equivalent water proofing Solution (1 litre of Zycosil/equivalent & 20 litres of water stirred f irst & 2 litres of Zycoprime/equivalent added and stirred (total 23 litres)) till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls. |
| 329 | In-filling / sealing of joint between RCC lintel cum sunshade and wall (on external side) in all floors by pushing in Grout RW/equivalent in paste form and coving 20 mm x 20 mm after applying a coat of Zycosil/equivalent & zycoprime/equivalent solution before cement plastering of top, bottom and sides of RCC sunshade. |
| 330 | Providing and fixing 15 mm thick false ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6&7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the exiting frame work consisting of T-sections and Lsections suitably fixed according to tile size as per direction of Engineer-in-charge |
| 331 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 gram per Sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per Sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 332 | With semi perforated 12 mm thick micro tegular edged GRG \false ceiling tiles |
| 333 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge |
| 334 | With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6 |
| 335 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid Poor/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made |
| 336 | Frame size 50 x 100 mm |
| 337 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 338 | 35 mm thick |
| 339 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 340 | 35 mm thick |
| 341 | P/F stainless steel first quality curtain rod with all fitting and fixture i/c bracket and all other necessary accessories complete as per direction of engineer in charge. |
| 342 | S/F of MS steel shutter Almirah type made from 1.0mm. Thick MS Sheet including frame hold fast mortise handle lock with double key looking mirror frame steel pegs on back side and i/c hammer painting of approved shade on front and three coats of synthetic enamel paint at backside i/c grouting in wall with 1:2:4 cement concrete i/c supply of all material labour & T&P etc. required for proper completion of the work |
| 343 | S/F of 100 mm wide vertical blinds NEHA/VISTA/CLASSIC or any other equivalent approved brand with prior approval of EIC, complete in all respect. |
| 344 | Providing & fixing of rolling blinds NEHA/VISTA/CLASSIC or any other equivalent approved brand with prior approval of EIC, complete in all respect |
| 345 | Providing laying and jointing 160 mm dia UPVC pipe of Ist quality complete in all respect as per direction of EIC |
| 346 | Providing laying and jointing 110 mm dia UPVC pipe of Ist quality complete in all respect as as per direction of EIC |
| 347 | Providing laying and jointing 75 mm dia UPVC pipe of Ist quality complete in all respect as as per direction of EIC |
| 348 | Making Knobs in 12 mm square bar used in fencing including smithy work complete in all respect. |
| 349 | Providing laying and jointing 75 mm dia SWR pipe single socket type B of Ist quality prince make or equivalent approved makecomplete in all respects as per directions of EIC |
| 350 | Providing laying and jointing 90 mm dia SWR pipesingle socket type B of Ist quality prince make or equivalent approved make complete in all respects as per directions of EIC |
| 351 | Providing laying and jointing 110 mm dia SWR pipe single socket type B of Ist quality prince make or equivalent approved make complete in all respects as per directions of EIC |
| 352 | Providing laying and jointing 160 mm dia SWR pipe single socket type B of Ist quality prince make or equivalent approved make complete in all respects as per directions of EIC |
| 353 | Providing and fixing health faucet with 8 mm dia, 1 meter long flexible Tube & Wall hook. Jaquar make model no. ALD 573 or equivalent approved make as per directions of EIC |
| 354 | Providing and fixing under counter wash basin with fitting accessories size 485x370x205 mm shape rectagular jaquar make model no. CNS-WHT-701 or equivalent approved make as per directions of EIC |
| 355 | Providing and fixing wall hung full padestal wash Basin with fixing Accessories size 560x415x200 mm pedestal jaquar make model no. CNSWHT 801 & CNW WHT 301 or equivalent approved make as per directions of EIC |
| 356 | Providing and fixing CP brass angular stop cock with valve flange Jaquar Make Model No. CON-059KN or equivalent approved make as per directions of EIC |
| 357 | Providing and fixing CP brass pillar cock Auto closing system jaquar Make Model No. PRS-031 or equivalent approved make as per directions of EIC |
| 358 | Providing and fixing Corner Glass Shelf (With Bracket) jaquar make model no. ACN-1173 or equivalent approved make as per directions of EIC |
| 359 | Providing and fixing Toilet Paper Holder with stainless steel flap jaquar make model no. ACN-1153S or equivalent approved make to be fixed with C.P. brass screws complete as per direction of the engineer-in-charge. |
| 360 | Providing and fixing Bottle Trap jaquar make 32 mm size with 250 mm x 190 mm long wall connection pipe & Wall Flange model no. ALD-PHR-769L250x190 or equivalent approved make as per directions of EIC |
| 361 | Providing and fixing Towel Ringround with Round Flange jaquar model no. Can-1121BN or equivalent approved make to be fixed with CP brass screws etc. complete as per direction of the engineer in charge. |
| 362 | P/F CP brass bib cock jaquar make CON-047KN with wall flange or equivalent of approved make as per directions of Engineer in Charge. |
| 363 | P/F 15mm dia long body bib cock Jaquar make Model No. CON-107-KN or equivalent of approved make as per direction of Engineer in Charge. |
| 364 | Providing and fixing 75 mm dia upvc nahani trap with material and labour etc complete as per directions of EIC |
| 365 | Providing and fixing 100 mm dia CP floor jali (Heavy Duty) as per direction of EIC |
| 366 | Brick work with old bricks (supplied free of cost at our stores) in superstructure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 367 | Brick work with old bricks (supplied free of cost at our stores) in superstructure above plinth level up to floor V level in cement mortar 1:6 (1 cement : 6 coarse sand) |
| 368 | Half brick masonry with old bricks (supplied free of cost at our central stores) in superstructure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand) masaonry with old bricks (1:4 cm) etc. complete in all respects as per directions of EIC |
| 369 | Supplying and fixing SS pull handle H type (pair) size of 450 mm Dorset make model no. SH 18 P SS or equivalent of approved make as per direction of EIC |
| 370 | Supplying and fixing SS pull handle H type (pair) size of 300 mm Dorset make model no. SH 12 P SS or equivalent of approved make as per direction of EIC |
| 371 | Supplying and fixing SS pull handle H type (pair) size of 600 mm dorset make model no. SH 24 P SS or equivalent of approved make as per direction of EIC |
| 372 | Extra difference cost for providing and fixing glass door fitting combo set with lock patch. Top bottom patch fittings of dorset model no. CS 100 WL or equivalent approved make having brand logo embossed on the body/plate with a double spring mechanism and door weight upto 100 kg for doors, including cost of cutting floor, embedding in floors as required and making good the same matching to the existing floor finishing and cover plate with brass pivot and single piece MS sheet (With SS Cover plate minimum 1.25 mm thickness) outer box with slide plate etc. complete as per the direction of EIC. |
| 373 | Extradifference cost for providing and fixing glass door fitting combo set with lock patch. Top bottom patch fittings of dorset model no. CS 70 WL or equivalent approved make having brand logo embossed on the body/plate with a double spring mechanism and door weight upto 70 kg for doors, including cost of cutting floor , embedding in floors as required and making good the same matching to the existing floor finishing and cover plate with brass pivot and single piece MS sheet (With SS cover plate minimum 1.25 mm thickness) outer box with slide plate etc. complete as per the direction of EIC. |
| 374 | Supplying & fixing of 10 mm thick pvc wall penaling with prior approval of EIC, complete in all respect. |
| 375 | Providing, mixing and applying 12 mm thick ready mix cement plaster of approved makeas per specifications and directions of Engineer-in-charge. |
| 376 | Providing, mixing and applying 15 mm thick ready mix cement plaster of approved makeas per specifications and directions of Engineer-in-charge. |
| 377 | Brick work with old bricks (supplied free of cost at our stores ) in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 378 | Brick work with old bricks (supplied free of cost at our stores ) in foundation & plinth in cement mortar 1:6 (1 cement: 6 coarse sand) |
| 379 | Providing and fixing 1mm thick lamination on door of green Lam make or equivalent of approved colour and shade as per direction of the EIC. |
| 380 | Providing and fixing 12 mmthick toughened glass in fixed portion including godrej glass clip fittings or equivalent as per approved make necessary holes etc. for fixing required fitting, all complete as per direction of EIC |
| 381 | Providing and fixing 35 mm thick ISI mark ply flush door shutters non-decorative type of century ply make or equivalent approved make complete in all respects as per directions of EIC |
| 382 | Providing and fixing S.S. Sliding door bolt of 200x16 mm with nuts and screw etc. complete as per direction of EIC |
| 383 | Providing and fixing mortice handle lock with of doorset make model no. Cetto |
| 384 | Providing and fixing hydraulic door closer Godrej make or equivalent approved make with necessary accessories and screws etc. complete in all respects as per directions of EIC |
| 385 | Providing and fixing Parryware piller cock auto closing Model No. G2013A1 or equivalent of approved make as per direction of Engineer in charge. |
| 386 | Providing and fixingof white glazed earthenwave half stall (Flat Back Large) urinal 1st quality HINDWARE, CERA, PARRYWARE make of required specials fittingand 32mm dia G.I. waste pipe etc complete in all respects as per directions of E.I.C. |
| 387 | Providing and fixing Urinal valve auto closing system with built- in control cock & Wall Flange Jaquar Make Model No. PRS-077 or equivalent of approved make as per direction of engineer in charge. |
| 388 | Providing and fixing Wall hung Urinal division HINDWARE make model no. SU810SC-C-STD-CR or equivalent of approved make as per directions of E.I.C. |
| 389 | Providing and fixing counter top Wash basin MEDIAN model no. 91069 of Hindware make or equivalent of approved make as per directions of E.I.C. |
| 390 | Providing and fixing wash basin size of 630x450 mm with C.I. brackets, 32 mm C.P. brass waste of standard pattern, cutting and making good the walls wherever required as per instruction of EIC. |
| 391 | Providing and fixing 5 mm thick toughened glass etc complete as per directions of E.I.C. |
| 392 | Providing & fixing Dorset floor spring modle no. CS100 GM |
| 393 | Providing & Fixing Rimless Single piece WC with PP soft close slim seat cover, Hinges, Dual Flush cistern fitting, fixing accessories and accessories set, size 370x 665x750mm S Trap 220mm Jaquar make Model no CNS-WHT-853S220SPPSM |
| 394 | Providing & Fixing Swan Neck Tap with right hand operating knob with 450mm long Braided hose Model no 127BKN of Jaquar Make. |
| 395 | Fixing glazed/ceramic/Vitrified floor tiles with cement based high polymer modified quick set tile adhesive (Water based) conforming to IS 15477, in average 6mm thickness (600 x 600mm) |
| 396 | Providing & Fixing beveled edge mirror of supeior glass (of approved quality and required size) complete with 6 mm thick cement bonded particle board ground fixed to spacers with C.P. brass / SS secrew and washers etc all complete as per direction of Engineer In Charge. |
| 397 | Providing and fixing 10 inch length and 10mm dia square shapeStainless Steel tower bolts of Dorset make model no. TS-1010-10\" or equivalent approved make with SS screws etc. complete. |
| 398 | Providing and fixing 12 inch length and 10mm dia square shape Stainless Steel tower bolts of Dorset make model no. TS-1210-12\" or equivalent approved make with SS screws etc. complete. |
| 399 | Providing and fixing 250x16 mm size Stainless Steel Aldrop of Dorset make model no. ALDSM (250x16) or equivalent approved make with nuts and SS screws etc. complete. |
| 400 | Providing and fixing 300x16 mm size Stainless Steel Aldrop of Dorset make model no. ALDSM (300x16) or equivalent approved make with nuts and SS screws etc. complete. |
| 401 | Providing and fixing Door mounted hanging type Door Stopper of Dorset make model no. DS HT (Z) or equivalent approved make with SS screws etc. complete. |
| 402 | For Calculation purpose only |
| 403 | Sub Total (A) |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail