| 1 | Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation of stays & Poles, laying of cables etc and getting out in soft / loose soil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm using excavated soil complete all as specified and as directed. |
| 3 | Removing excavated material/ surplus soil n.exc 50 metres and depositing where directed at a level n.exc 1.5 metre above the starting point complete all as specified and as directed. |
| 4 | Supply, laying/ spread in trenches, sieving sand including cleaning, spreading, levelling, punning for laying/ cushioning of cable complete all as specified and as directed.Note:- Punned thickness shall be measured and paid. |
| 5 | Supplying and laying Flyash bricks standard size for protection of cable complete all as specified and as directed. |
| 6 | M & L for Cement concrete Type D-2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete including form work complete all as specified and as directed. |
| 7 | M & L for Cement concrete Type C-1, 1:3:6 (20mm graded aggregate) for coping to the poles with finishes with out using extra cement complete all as specified and as directed. |
| 8 | Disconnecting and taking out the old unserviceable LT UG cable in trenches, wall & poles and taken as credit including supply and Laying in trenches/ poles/ wall etc LT UG Cable XLPE insulated, armoured, heavy duty with multistranded aluminium conductor, 1100 volts grade conforming to IS specifications and of the following sizes:-Note:- Lugs and glands are deemed to be includinguded in the rate quoted for laying of cable and to be used wherever required while connecting cables to the panel board. Earth work such as excavation, refilling etc, shall be measured and paid separately under relevant item. |
| 9 | (a) LT UG cable 4 core 10 sqmm |
| 10 | (b) LT UG cable 4 core 16 sqmm |
| 11 | (c) LT UG cable 4 core 25 sqmm |
| 12 | (d) LT UG cable 3.5 core 35 sqmm |
| 13 | (e) LT UG cable 3.5 core 50 sqmm |
| 14 | (f) LT UG cable 3.5 core 70 sqmm |
| 15 | (g) LT UG cable 3.5 core 95 sqmm |
| 16 | (h) LT UG cable 3.5 core 185 sqmm |
| 17 | Re- laying only (where directed at site) in trenches and connecting with suitable size of cable jointing kit/lugs/ thimble etc. serviceable underground cable retrieved from taking out as Srl No- 08 of above schedule of following sizes:-Note:- Cable jointing kit will be measured & paid separately under relevant items of Sch \"A\". |
| 18 | (a) LT UG cable 4 core 10 sqmm |
| 19 | (b) LT UG cable 4 core 16 sqmm |
| 20 | (c) LT UG cable 4 core 25 sqmm |
| 21 | (d) LT UG cable 3.5 core 35 sqmm |
| 22 | (e) LT UG cable 3.5 core 50 sqmm |
| 23 | (f) LT UG cable 3.5 core 70 sqmm |
| 24 | (g) LT UG cable 3.5 core 95 sqmm |
| 25 | (h) LT UG cable 3.5 core 185 sqmm |
| 26 | S & F Straight through joints (epoxy) heat shrink type for underground cable including joint kits and labour complete for making joints suitable for LT PVC sheathed / armoured heavy duty cables with aluminium conductor of following sizes :- |
| 27 | (a) LT UG cable upto 4 core 16 Sqmm |
| 28 | (b) LT UG cable 3.5/4 core 25 sqmm to 50 sqmm |
| 29 | (c) LT UG cable 3.5 core 70 to150sqmm |
| 30 | (d) LT UG cable 3.5 core 185 to 300 sqmm |
| 31 | Supplying and fixing in replacement of pole mounted Sheet Moulded Compound (SMC) Box weather proof type with hinged type door off white colour of size not less than 185X100X290mm (LxBxH) comprising of 1 No MCB 6A and 1 No neutral link, bottom to top open front door and 63 Amps heavy duty connector blocks complete fixed on pole with suitable two nos clamps, bolts and nuts complete all as specified and as directed. |
| 32 | M & L for dismantling and taking down the existing street light fitting led type for repair and replacing the unserviceable LED driver with new upto 100W LED 5700K and refixing the same in the existing pole duly wired complete all as specified and as directed. |
| 33 | M & L for removing the existing street light fitting of any type & make and Supply & installation of new 90W LED street light epoxy powder coated pressure die-cast aluminium housing and LED driver cover, one time factory set 3 step dimmable driver used is specially designed to have built- in surge voltage, open/ short circuit protections source in the existing pole duly wired complete all as specified and as directed.Make:- Bajaj cat no- ENXT P 108L WH CR TG FSD or Equivalent |
| 34 | Removing the existing Gate light & Supply and installation of new 40W LED 5700K New generation Post top energy saving & environmental friendly long life versatile spun aluminium IP66 roadway luminaries with high power LED as light source and connecting in the existing cable complete all as specified and as directed. |
| 35 | Supply and laying 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 3 core 2.5 sqmm nominal cross section in service connections/street light connection from junction box to street light fittings complete all as specified and as directed. |
| 36 | S & F LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 37 | S & F time switches 250V single Phase of 20Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed. |
| 38 | S & F MCCB 4 pole 400 Amps,415 volts with rupturing capacity 35KA, adjustable thermal & fixed magnetic setting including taking out old one complete all as specified and as directed. |
| 39 | S & F MCCB 4 pole 250 Amps,415 volts with rupturing capacity 25KA, adjustable thermal & fixed magnetic setting including taking out old one complete all as specified and as directed. |
| 40 | S & F MCCB 4 pole 125 Amps,415 volts with rupturing capacity 16KA, adjustable thermal & fixed magnetic setting including taking out old one complete all as specified and as directed. |
| 41 | S & F MCCB 4 pole 63 Amps,415 volts with rupturing capacity 16KA, adjustable thermal & fixed magnetic setting including taking out old one complete all as specified and as directed. |
| 42 | Preparation of old surface and painting of steel/ RCC tubular electric poles above coping level including brackets, clamps etc with good quality silver paint (two coat) complete including writing pole no complete all as specified and as directed. |
| 43 | S & F Street light panel Timelite Distribution Board 32 A 3 pole/ 230 V -Analog Time Switch having following features, Phase-3, Frame size-1, Max Load(KW)-6, Timer Digital 24 Hr Contactor rating(A)-65TP, MCB Rating 63 TPN, Ref Standard Degree of Protection IP 54 Dust and Vermi Proof complete all as specified and as directed. |
| 44 | M & L for preparation of old painted surfaces of LT panel/Feeder piller box of any type outdoor/indoor including removing old paint with scrubbing and applying one coat of synthetic enamel paint of shade as per existing over a coat of red oxide primer, with electrically operated spray machine complete all as specified and as directed. |
| 45 | M & L for Earthing complete with copper earth plate electrode 60 × 60cm × 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth lead strip 20 × 3mm (upto 7.5 m in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C-1 chamber with RCC 1:2:4 type B-1 40 mm thick cover with MS rod 8 mm dia 150 mm long reinforcement , watering funnel with 25 mm dia light grade for watering and for protection of earth electrode 40 mm GI pipe and tested on completion complete all as specified and as directed. |
| 46 | Supply, install, test & commissioning LT panel out door, floor mounted/pedestal type, cubical, self supported,CPRI approved ,front and rear openable , double door hinged type with locking arrangement and slopping top canopy ,suitable ventilations on both sides with wire mesh, IP-52 protection with dust and vermin proof etc. fabricated out of 3.15 mm CRCA sheet duly powder coated with 7 tank chemical process, mounted/fixed on and including MS angle iron stand of 1.0 mtr height (50 cm above FFL and 50 cm below FFL) ,fabricated out of 50x50x6 mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5 sqmm, suitable size/capacity of copper strips for switch gear connection from main bus bar, earth bus strip of 32x6 mm size for entire length of panel ,suitable size of MS gland with gland plate and alluminium lugs/thimbles for all incoming/out going cables etc. complete all as specified and as directed. |
| 47 | Accommodating the followings:-(I) MCCB 4 pole, 415 Volts, 250 Amps rating, rupturing capacity 35 KA thermal magnetic release, fixed over load and short circuit protection - 01 No (for incoming) (ii) MCCB 4 pole, 415 Volts, 125 Amps rating, rupturing capacity 25 KA thermal magnetic release, fixed over load and short circuit protection - 03 Nos (for outgoing)(iii) MCCB 3 pole, 415 Volts, 100 Amps rating, rupturing capacity 16KA thermal magnetic release, fixed over load and short circuit protection - 02 Nos (for outgoing) (iv) LED type Phase Indicator with controlling fuses for RYB - 01 set .(v) Digital Ammeter 96 sq.mm 0 - 100 Amps with suitable CT\"s and selector switch -01 set(vi) Digital volt meter 96 sq.mm 0 - 500 volts with selector switch -01 set(vii) Timer switch (Auto switching device operating on real time) digital type with min. switching time of 1 sec, having wide range of switches week & day program with reserve 30 min , including one MCB TP 32 Amps and one contactor three phase, 4 pole, AC control, 415 Volts, 25 Amps(viii) Electrolyte copper busbars PVC colour sleeved 320 Amps capacity TPN mounted on hygroscopic insulator duly colour coded RYB & Green sleeves(ix) 250 Amps off load change over switch- 01 |
| 48 | Taking down the old unserviceable junction box and taken as credit including S & F Junction box PVC (FRP) Junction Boxes weather proof type with hinged type door off white colour of size 280x145x100mm with three pole connector and 1 No neutral link complete fixed on pole with suitable clamps, bolts and nuts with 6A MCB and fixing arrangements complete all as specified and as directed.Make:- Sintex or equivalent. |
| 49 | M & L for removing the existing street light fitting of any type & make and Supply & installation of new street light fittings,60W LED 5700K New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaries with high power LED as light source in the existing pole duly wired complete all as specified and as directed. |
| 50 | Removing the existing Gate light & Supply and installation of new 40W LED 5700K New generation Post top energy saving & environmental friendly long life versatile spun aluminium IP66 roadway luminaries with high power LED as light source and connecting in the existing cable complete all as specified and as directed. |
| 51 | Supply and laying 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 3 core 2.5 sq. mm nominal cross section in service connections/street light connection from junction box to street light fittings complete all as specified and as directed. |
| 52 | Labour only for attending and identifying electric supply complaints no lights and day to day maintenance of existing switch board, DB\"s, LT Panels including connecting electrical accessories/ spares of elect supply installations, electrical fitting with lights, short circuits in any OTM/Md accn/ Pump house as per complaint register complete all as specified and as directed. |
| 53 | (Note for Ser No 31):-(i) The quoted rate shall deemed to be including the cost of labour involve under repaired item.(ii) The complaints shall be attended and the defects shall be rectified by a team of experienced electrician as applicable assisted with adequate number of helpers as directed by Engineer-in-charge but minimum provision of executing team are as under :- 1. Electrician ( semi-skilled)- 02 Nos 2. Helper (un-skilled) for electrician - 01 No (iii) Engineer-in-charge may decided to depute team per day to complete the complaint within 08 hours. Per day execution of complaints shall be measured and paid under item No 66.(iv) All T&P required for attending the complaints shall be provided by the contractor without any extra cost of govt.(v) The Electrician shall always in possession of all Electrician tools, LT Megger, Earth Tester, MultiMate, Crimpling tool, insulation tape, Hand gloves, Ladders etc required at site.(vi) Noting of the complaints in complaint register complete all as specified and directed.(vii) Contractor will submit group insurance of deputed employees from any authorised Govt Agencies. |
| 54 | Taking down the unserviceable point wiring of lights, fans, sockets complete including switches, switch sockets outlets, fan regulators, lamp holder, ceiling rose, etc excluding light fittings and depositing where directed and making good the disturbed surfaces to match with the existing surface complete all as specified and as directed. |
| 55 | Taking down the existing unserviceable MCB DB along with MCBs of any type and capacity and depositing where directed and making good the disturbed surface to match with the existing surface complete all as specified and as directed. |
| 56 | M & L for Wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable FRLSH 1100 volts grade, multistranded with copper conductors conforming to IS specifications, with colour code drawn through and including non metallic rigid PVC conduit, PVC conduit fittings and conduit accessories or casing capping including accessories fixed on wall / ceiling or concealed on wall and fixed on ceiling etc with suitable clamps, screws, etc or concealed in wall including cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 for concealed conduit wiring and making good the disturbed surfaces, matching with the existing wall surfaces, cutting not exceeding 10 cm girth, including provn of 1.5 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed:- |
| 57 | One light point controlled by one switch |
| 58 | One fan point controlled by one switch and one regulator |
| 59 | One 3 pin 5 Amps switch socket on independent board |
| 60 | One 3 pine 5 amps switch socket on same board along with other switches. |
| 61 | One bell point controlled by bell push switch on independent board. |
| 62 | All as per item No.34 herein before but with 2.5 Sqmm single core PVC cable for one 3 pin 15 amps switch socket outlet on independent board. |
| 63 | M & L for sub main wiring with PVC insulated, 1100 volts grade single core FRLSH multistranded copper conductor cable conforming to IS specifications, 2 runs of 10 sqmm including one run of 10 sqmm single core multistranded copper conductor PVC insulated cables as earth continuity conductor with colour code drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories or casing capping including accessories fixed on wall/ceiling etc, or concealed in wall and connecting to common earth dolly including taking down old unservicable complete all as specified and as directed. |
| 64 | All as per item No.35 herein before but with 2 runs of 6 Sqmm and one run of 1 x 6sqmm earth wire in PVC conduit complete all as specified and as directed. |
| 65 | All as per item No.35 herein before but with 2 runs of 4 Sqmm and one run of 1 x 4 sqmm earth wire in PVC conduit complete all as specified and as directed. |
| 66 | All as per item No.35 herein before but with 2 X 2.5 sqmm + 1 X 2.5 sqmm earth wire in PVC conduit or casing capping as specified and as directed. |
| 67 | All as per item No.35 herein before but with 2 X 1.5 sqmm + 1 x1.5 sqmm earth wire in PVC conduit or casing capping complete all as specified and as directed. |
| 68 | All as per item No.35 herein before but with 4 runs of 10 sqmm and one run of 2 x 10 sqmm earth wire in PVC conduit complete all as specified and as directed.Note for item Nos 35 to 39:-(a) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.(b) For concealed wiring wherever required cutting chases will be measured separately under relevant items. |
| 69 | S & F in repairs LED post top latern made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP65 protection complete all as specified and as directed.Make:- Bajaj Cat No-BGCT 24 LED WW/ Crompton Greaves Cat No-LBLA1-10-CDL or equivalent |
| 70 | S & F in repairs Ceiling rose surface Bakelite 65mm x 50 mm two to three terminals complete all as specified and as directed. |
| 71 | S & F in repairs Switch piano flush type 5 amps single pole, one way, 240 Volts complete all as specified and as directed. |
| 72 | S & F in repairs Switch socket outlet 3 pin, 5 amp, flush type complete all as specified and as directed. |
| 73 | S & F in repairs Socket outlet 3 pin 5 Amps flush type complete all as specified and as directed. |
| 74 | S & F in repairs Bell push flush type 5 amps single pole 240 Volts complete all as specified and as directed. |
| 75 | S & F in repairs Buzzer, AC, 230 volts, single pole complete all as specified and as directed. |
| 76 | S & F in repairs Bell ding dong, AC, 230 volts, single pole complete all as specified and as directed. |
| 77 | S & F in repairs Bell Musical type complete all as specified and as directed. |
| 78 | S & F in repairs Socket outlet 3 pin 15 amps flush type complete all as specified and as directed. |
| 79 | S & F in repairs Switch socket outlet multipurpose 3 pin, 15amps and one pin, 5amps controlled by one switch complete all as specified and as directed. |
| 80 | S & F in repairs stepped type electronic fan regulator flush type on the exiting phenolic laminated sheet extra as required complete all as specified and as directed. |
| 81 | S & F in repairs Modular Switch Roma flush DIRECT TO FIT press type 10 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed.Make:- Anchor Roma or Equivalent |
| 82 | S & F in repairs Modular Switch Roma flush DIRECT TO FIT press type 16/20 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed.Make:- Anchor Roma or Equivalent |
| 83 | S & F in repairs Modular Socket Roma flush DIRECT TO FIT press type 10 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed.Make:- Anchor Roma or Equivalent |
| 84 | S & F in repairs Modular Socket Roma flush DIRECT TO FIT press type 16/20 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed.Make:- Anchor Roma or Equivalent |
| 85 | S & F in repairs PVC Gang box surface type suitable for fixing of 5 pin 15 Amp multipurpose switch socket on wall complete all as specified and as directed. |
| 86 | S & F in repairs PVC Gang box surface type suitable for fixing of 5 pin 5 Amp multipurpose switch socket on wall complete all as specified and as directed. |
| 87 | S & F in repairs Lamp holder insulated body complete all as specified and as directed. |
| 88 | S & F in repairs Modular Fan step regulator, 120W- 1 module for ceiling Fan of 1200 mm sweep complete all as specified and as directed. |
| 89 | S & F in repairs Modular white cover with plate with frame 2 module including matching with white cement work if necessary complete all as specified and as directed. |
| 90 | S & F in repairs Modular white cover with plate with frame 3 module including matching with white cement work if necessary complete all as specified and as directed. |
| 91 | S & F in repairs Modular white cover with plate with frame 4 module including matching with white cement work if necessary complete all as specified and as directed. |
| 92 | S & F in repairs Modular white cover with plate with frame 6 module including matching with white cement work if necessary complete all as specified and as directed. |
| 93 | S & F in repairs Modular white cover with plate with frame 8 module including matching with white cement work if necessary complete all as specified and as directed. |
| 94 | S & F in repairs Modular white cover with plate with frame 12 module including matching with white cement work if necessary complete all as specified and as directed. |
| 95 | S & F in repairs Modular white cover with plate with frame 16 module including matching with white cement work if necessary complete all as specified and as directed. |
| 96 | S & F in repairs Modular flush box 1/2 module |
| 97 | S & F in repairs Modular flush box 3 module |
| 98 | S & F in repairs Modular flush box 4 module |
| 99 | S & F in repairs Modular flush box 6 module |
| 100 | S & F replacement of metal clad socket single pole and neutral enclosure with a two pin and earth plug top and socket complete with one single pole MCB 230 Volts 20/32 Amps complete all as specified and as directed. |
| 101 | Dismantling existing unservicable hylam sheet of any size from boards removing switches etc. S & F hylam sheet 3mm thick including necessary cutting of suitable opening for switches, sockets, regulators, etc refixing of switches, sockets, regulators, etc replacing screws and connecting up and testing complete all as specified and as directed. |
| 102 | S & F inrepairs MCCB Distribution board, TP&N , vertical , double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link,415 Volts 4 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete including 4 Pole V-Tec MCCB of 100 A rating & 16kA breaking capacity, MCCB pre-fitted at factory complete all as specified and as directed. |
| 103 | S & F in repairs MCCB Distribution board, TP&N, vertical, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 415 Volts 8 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete including 4 Pole V-Tec MCCB of 100 A rating & 16kA breaking capacity, MCCB pre-fitted at factory complete all as specified and as directed. |
| 104 | S & F in repairs MCCB four pole, 415 Volt, 100 Amps, 16 KA, adjustable thermal & fixed magnetic setting complete all as specified and as directed. |
| 105 | S & F in repairs MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 4 ways SPN Double door, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and as directed. |
| 106 | S & F inrepairs MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways SPN Double door, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and as directed. |
| 107 | S & F in repairs MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways SPN Double door, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and as directed. |
| 108 | S & F in repairs MCB Four pole 415 volts, 40 to 100 amps \"C\" Curve 10 kA Capacity complete all as specified and as directed.Make:- Havells/ L&T/ Legrand/ ABB |
| 109 | S & F in repairs MCB SPN, 240 Volts, 32 to 63 Amps, 10 kA rupturing capacity \"C\" series including taking down old one complete all as specified and as directed. |
| 110 | S & F in repairs MCB SP, 240 Volt, 6-32 Amps, 10 kA rupturing capacity \"C\" series including taking down old one complete all as specified and as directed. |
| 111 | S & F in repairs 40W LED aluminium battens high wattage decorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient complete all as specified and as directed.Make:- Havells Cat No LED Pride plus LHEXACP7IN1J040/ Bajaj Cat No BPTX 40W LED 4F WH/ Crompton Greaves Cat No CCS-100-40-65-HL2-DP-NWH |
| 112 | S & F in repairs 30W LED PC battens high wattage decorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient complete all as specified and as directed.Make:- Havells Cat No LED Pride Plus LHEXAWP7IN1W030/ Crompton Greaves Cat No TCS-104-10-65-SL-DP-NWH |
| 113 | S & F in repairs 10W LED battens decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy efficient complete all as specified and as directed.Make:- Havells Cat No-LED Pride Plus LHEXACP5IN1W010/ Bajaj cat No-BCLSB 10 WH or equivalent |
| 114 | S & F in repairs of surface mounted 24 W led LED luminaries of 2\"x 2\" complete all as specified and as directed.Make:- Havells LHEAABP71N1W024/ Bajaj Cat No BGSLO SLEEK 15 WH SQ/ Crompton LCTLRP-42-FO-CDL (2X2) |
| 115 | S & F 30W bldg security light fitting including suitable GI bracket and clamps nuts etc with best in class design and robust heat sink along with class leading IP, and surge protections for long lasting performance including taking down old unservicable light fitting complete all as specified and as directed.Make:- Havells Cat No-LHETAVU7PA70030/ Bajaj Cat No-BCLST 30W LED/ Crompton Greaves Astra Neo Cat No-LSTS-30-CDL/NL-M |
| 116 | S & F surface mounted LED panel PDC aluminium housing and high translucent diffuser makes it a luminaire efficiency 100 lm/W & 120 lm/W including taking down old unservicable light fitting complete all as specified and as directed.Make:- Crompton Cat No-LCDSPLN-R-CG-19 CDI/ Bajaj Cat No-BGSLO Sleek 18W WH RD or equivalent |
| 117 | S & F bulk head fitting PDC housing LED luminaire with opal diffuser, equipped with 2 KV in-built surge protection with IP 65 protection rating including taking down old unservicable light fitting complete all as specified and as directed.Make:- Bajaj Cat No-BIBWP 10W LED/ Crompton CIS-306-10-57-SL-DP-NBK or equivalent |
| 118 | S & F decorative wall mounting brushed nickel finish fixture with opel glass diffuser suitable with 9W LED lamp B22 base including taking down old unservicable light fitting complete all as specified and as directed.Make:- Havells Cat No-LHFOAJE1TZ11060 or equivalent |
| 119 | S & F decorative wall mounting brushed nickel finish fixture with opel glass diffuser suitable with 2 x 9W LED lamp B22 base including taking down old unservicable light fitting complete all as specified and as directed.Make:- Havells Cat No-LHFOAJE1TZ11060 or equivalent |
| 120 | Supply and laying in repairs of 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed twin core 4 sqmm nominal cross section in service connections complete all as specified and as directed. |
| 121 | Supply and laying in repairs of 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed twin core 6 sqmm nominal cross section in service connections complete all as specified and as directed. |
| 122 | Dismantling the following types of fans of any make/model/sweep, removing the burnt out winding wires, rewinding with winding wires and insulation materials overhauling/servicing, greasing/lubricating, insulating electric leads, assembling back checking for proper fixing and safety and testing complete all as specified and as directed for :- |
| 123 | (a) ceiling fan upto 1400 mm (56\") sweep. |
| 124 | (b) Exhaust fan upto 450 mm sweep. |
| 125 | (c) Wall mounting/pedestal fan/air circulator upto 600 mm sweep. |
| 126 | Supply only new items/parts of same specification existing and as described below for ceiling/ exhaust/ pedestal fans etc. |
| 127 | (a) Ball bearing for ceiling fan/Exhaust fan/Wall fan/Pedestal fan upto 1400mm sweep. |
| 128 | (b) Bush bearing for ceiling fan/Exhaust fan/Wall fan/Pedestal fan upto 1400mm sweep. |
| 129 | (c) Fan condenser capacitor 2.5 mfd. |
| 130 | (d) Fan clamp for ceiling fan complete with rubber shackle, shackle bolt, nut, cotter pin, clamp complete. |
| 131 | Taking Down and Refixing including Painting of water heaters (Geysers) of following capacity of any make/model in site with synthetic enamel paint by brush including filling of cavities with fillers one coat after cleaning all dust etc including writing MES numbers etc complete all as specified and as directed for:- |
| 132 | S & F Thermostat suitable for water heater upto 50 litres capacity. |
| 133 | S & F Heating element upto 1.5 KW/2 KW suitable size. |
| 134 | S & F Indicator lamp any type suitable for water heaters upto 50 litres capacity. |
| 135 | S & F Non return valve 15 mm dia size. |
| 136 | S & F PVC connections with brass check nuts 15 mm dia x 45 cm long for hot water supply and cold water supply. |
| 137 | S & F Plug top 3 pin 15 amps. |
| 138 | S & F Rubber gasket flat/\"O\" ring type suitable for water heater |
| 139 | S & F PVC cable 3 core flexible copper conductor cable of size 40/0.193 |
| 140 | S & F Pressure release Valve suitable for geysers upto 50 litres capacity. |
| 141 | S & F in repairs/ replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and as directed. |
| 142 | S & F in repairs/ replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed. |
| 143 | S & F in repairs/ replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200mm complete all as specified and as directed. |
| 144 | S & F in repairs/ replacement only louver, steel body for exhaust fan suitable size upto 300 mm for any height of BLDG (G+2) complete all as specified and as directed. |