| 1 | M & L for point wiring for one light/one fan controlled by one switch with 1.5 Sq.mm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with in and including PVC rigid concealed conduit (ISI marked) heavy duty suitable size with all fittings including pre galvanised ironl sunken box of adequate size with protective zink coating and having thickness not less than 18 gauge with 3mm thick hylem/masonite sheet ISI marked for switches and sockets , including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly, including cutting chiseling for concealed piping and making good disturbed surface to match with the existing surface complete all as specified and directed. |
| 2 | S & F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed. |
| 3 | S & F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 4 | M & L for point wiring with 4 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with in and including PVC rigid concealed conduit (ISI marked) heavy duty suitable size with all fittings including pre galvanised ironl sunken box of adequate size with protective zink coating and having thickness not less than 18 gauge with 3mm thick hylem/masonite sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 4 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface tomatch with the existing surface complete all as specified and directed. |
| 5 | M & L for providing/ cutting the round/ square hole of required size in wall finishing thedistrubed surfaces as per existing finishes complete all as spd and supply and fixing propeller MS ventilating fans, Single phase, 230 volts 300 mm or 12\" H.DEX fan (900RPM) sweepcomplete and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core copper cable of suitable size from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. |
| 6 | M & L for providing/ cutting the round/ square hole of required size in wall finishing thedistrubed surfaces as per existing finishes complete all as spd and supply and fixing propeller MS ventilating fans, Single phase, 230 volts 225 mm or 9\" H.DEX fan (900RPM) sweepcomplete and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core copper cable of suitable size from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. |
| 7 | Supply and installation of the electric water storage heater of ABS body type, 25 ltr capacity with rated power 2KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostat, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm bore with GI hexagonal adopters/nuts on both sides for inlet (cold water supply) & outlet (hot water supply) and including provision of wall mounting arrangements and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and as directed. |
| 8 | S&F, testing and connecting the ceiling fan copper winding with blade ,double bearing type, including down rods, electronic type regulator and accessories, 230V, 1200mm sweep BEE 5 atar rated included all neccessory item to hang and connection with suitable size copper wire in flaxible conduit including writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. |
| 9 | M&L for GI tubing medium grade 15mm bore on floor/wall including fittings complete including all necessary fittings to hold the pipe along the wall like hook, bolts, etc complete all as specified and as directed. |
| 10 | S&F 15mm dia fancy type CP Bib taps heavy duty, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. |
| 11 | S&F fancy type CP stop cock/angle valve heavy duty cast copper alloyscrewed down high pressure ,with crutch or butterflyhandle screwed both ends for iron pipe or for union of 15 mm borecomplete all as specified & directed |
| 12 | S&F sheet metal enclosure with sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 240 volts, complete with one single pole MCB of 20 amps \"C\" curve complete all as specified and directed . |
| 13 | S&F Viterous China wash basin, white, flat back, size 550x400mmexcluding taps etc but including brackets,including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specfied and as directed. |
| 14 | S&F 15mm dia 450 mm long PVC connection PTMT including brass check nut at both endsscrewed both endfor iron pipes complete all as specified and directed |
| 15 | S&F fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed. |
| 16 | S&F CP grating with hole/without hole of dia 75/100mm complete all as specified and as directed. |
| 17 | S&F 600mmx450mm beveled edge mirror of selected quality glass not less than 5.5 mm thick with edges rounded or beveled , mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 18 | S & F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 19 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor of 75mm bore pipe complete all as specified and directed by Engr-in-Charge. |
| 20 | S&F PVC (SWR) bends of 75mm bore complete all as specified and directed by Engr-in-Charge. |
| 21 | S&F PVC (SWR) junction single, (single-T), equal or unequal of 75mm bore complete all as specified and directed by Engr-in-Charge. |
| 22 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 toends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed. |
| 23 | Supply, installation and testing all weather inverter type Split AC unit indoor and outdoor of 1.5 Ton capacity, 5 star rated with EER not less than 3.2 complete with cordless remote control unit, inbuilt anti microbial air filtration for better indoor air quality including copper piping of suitable size with insulation, PVC drain pipe cliped to the wall, mounting plate for indoor unit including making hole of suitable size on wall for passing wire and copper pipes and making good the disturbed surface to match the existing surface complete all as specified and as directed |
| 24 | S&F Voltage stabilizer having MS body material for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 90 V to 280 V with output voltage stabilized at 230 V with accuracy of + 2.5%and of capacity 5.0 KVAincluding 3 core flexible copper wire drawn through including conccealed PVC conduite medium grade fromstabilizer to power point and making good the disturbed surface complete all as specified and as directed. |
| 25 | M&L for sub Main Wiring with two Run of single core PVC insulated unsheathed multistrand FRLS-H flexible copper conductor cable of size 2x4 sqmm and one PVC insulated multistrand unsheathed FRLS-H flexible copper conductor cable of size 4 sqmm(green colour)as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed rigid conduit 20mm dia complete andmaking good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed.Note:-Two run of submain wire (phase and neutral) and one run of earth wire including PVC conduit and accessories will be measured as one run. |
| 26 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps. complete all as specified and directed . |