| 1 | M&L for vitrifiedtiles light shade (premium quality) 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but n. exc 0.42 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 20 mm thick screed bed in cement mortar (1:4) complete all as specified and directed. |
| 2 | M&L for 100 mm thickPCC (1:2:4), type B-1 (using 20mm graded stone aggregates) as in flooring including necessary form work and even and smoth without using extra cement complete all as specified and directed. |
| 3 | M&L for PCC type B-0, 1:2:4 (using 12.5mm graded aggregate) as in coping,roof ,kerb, benching, hold fast, water troughs, bed block and the like including weathering, slightly rounded or chamfered angle and throating including necessary form work complete all as specified and directed |
| 4 | M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar (1:6) complete all as specified and directed. |
| 5 | M&L for rendering 15 mm thickon concrete/brick surface on wallin cement mortar (1:6) other than fair face of brick work, finished even and smooth without using extra cementcomplete all as specified and directed. |
| 6 | M&L for preparation of newplastered or un-plasteredwall surfaces and applying two or more coats of 100% premium quality acrylic emulsion paint (Apex ultima) having VOC less than 50gm/ Ltr and UV resistence as per IS 15489:2005, alkali and fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with slilicon additive @ 1.43 ltr/10 Sqm over and including a coat of exterior primer applied @ 0.902 ltr/ 10 Sqm with roller finish complete all as specified and directed by GE. (Note:- After painting works, cleaning of all floors, glass and furniture by own arrangement) |
| 7 | M&L for plates Fe-410-W (Gde-E-250) quality-B (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 8 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth andapplying two coats of synthetic enamel paint over a coat of red oxide zic chrome primer complete all as specified and directed. |
| 9 | S&F for pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mmthick of approved colour having tensile strength 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed. |
| 10 | M & L for Hand rails, wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for ecuring wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar workonforming to Fe-290 Gde E-165 complete all as specified and directed |
| 11 | S &F for structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed. |
| 12 | S&F for Joist, channel, angle, or tee sections fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) work confirming to Fe-410- W(Gde-E-250)quality-B complete all as specified and directed. |
| 13 | S & F for Powder coated aluminium frame (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket complete all as specified and directed. |
| 14 | S&F for 100mm size brass motrice lock, vertical type, two lever fixed in door complete as in repair all as specified and directed. |
| 15 | S&F for Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperature 1.4mm and fixed with tinned tacks, or stainless steel wire staples in steel windows/ wooden doors completeall as specified and directed. |
| 16 | S&F for 4 mm thick sheet glass ordinary quality and glazing with oil putty/beads and pins/spring pins in squares n . exc 0.50 sqm in each paneto be fixed in any position at any hight upto to two story building complete all as specified and directed. |
| 17 | S & F for 150 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 18 | S & F for 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified. |
| 19 | S&F for 110mm bore PVC SWR bends of any radius complete all as specified and directed. |
| 20 | M&L for 4mm thick non asbestos fibre cement building board fixed in and including aluminium anodised snap grid frame work as in false ceiling all as specified size of grid 605x605 mm with aluminium main T section of size 36.5 x25 mmx 1.4 mm weighing 0.24 kg per running metre and cross T of size 23.5 x 26.4 x1.4mm weighing 0.191 kg per RM with aluminium wall angle size 40 x 25 x 2 mm including GI supporting wire of 3mm dia complete all as specified and directed. |
| 21 | S&F for Powder coated anodised aluminium door shutters with powder coating not less than 50 micron of any colour, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, mortice lock, 1 Nos floor door stopper, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 22 | S &F for3 ways sliding anodised aluminium (powder coated) glazed window shutter with frame with the following specification(a) Frame 50 mm x 65 mm x 1.5 mm Thick (b) 35 mm x 35 x 1.5 mm Z section in stiles, rails(c) 35 mm x 35 mm x 1.5 mm T section mullion (d) two shutter with PVC gasket with 4 mm thick tinted glass, including aluminium handles with necessary locking arrangement and one shutter with stainless steel wire cloth. 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc as directed by Engr-in-Charge. |
| 23 | S&F for aluminium structural insulated panel ( PUF sandwich wall panel) of 12 mm thickcomplete all as specified and directed. |
| 24 | M&L for point wiring (consealed) for one power point for one metal plug and socket set for AC or one socket for Geyser point on independent board controlled by one-MCB, 32 Amps (in and including) with 4.00 Sqmm. (nominal area) single core FRLSH,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid concealed PVCconduit of 20mm dia (Medium grade)complete with all acessories including PVC sunk box ISI marked and 4.00 Sqmm. (nominal area) single core FRLSH, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making goodthe diturbed surfacescompete all as specified and directed.(Note:-(a) Three run of copper conductor of required size and one run of PVC conduit and accessories measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth.(b) Quoted rates shall be deemed to be inclueded for copper conductor cable, conduit & accessories , MCB and sunken box of suitable size and cutting,chasing, penning for concealed point wiring n. exc 10 cm girth in brick wall/ concrete surfaces including making good the disturbed surfaces where required and pointing in cement mortar (1:3) with necessary matching existing colour duly putting etc. complete as directed.) |
| 25 | M&L for point wiring (consealed) for one light point/fan point/exhaust fan pont/ bell point controlled by one-one way 5/6 amp switchwith 1.5 Sqmm. (nominal area) single core FRLSH,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid concealed PVCconduit of 20mm dia (Medium grade)complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLSH, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making goodthe diturbed surfaces compete all as specified and directed.(Note:-(a) Three run of copper conductor of required size and one run of PVC conduit and accessories measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth.(b) Quoted rates shall be deemed to be inclueded for copper conductor cable, conduit & accessories, cover plate and sunken box of suitable size and cutting,chasing, penning for concealed point wiring n. exc 10 cm girth in brick wall/ concrete surfaces including making good the disturbed surfaces where required and pointing in cement mortar (1:3) with necessary matching existing colour duly putting etc. complete as directed.) |
| 26 | Description all as per srl item No. 25 above but for one 5 pin, socket outlet,5/6 Amps on same board with other switches complete all as specified and directed. |
| 27 | Description all as per srl item No. 25 above but for one 5 pin, socket outlet, 5/6 Amps on independent board complete all as specified and directed. |
| 28 | Description all as per Serial item No 25above but for one 3 pin, 15/16 Amp socket outlet independent with2.5 sqmm PVC insulated FRLSH multistraind copper cable with 2.5 sqmm single core multistraind FRLSH copper cable as earthling lead complete all as specified and directed. |
| 29 | S&F for switch modular typeone way, 6 Amps 240 volts, with one module matching with existing plate complete all as specified and directed. |
| 30 | S&F for switch modular typeone way 16 Amps 240 volts, with one module matching with existing plate complete all as specified and directed. |
| 31 | S&F for shuttered socket outlet modular type6 Amps , 2/3 pin combined, 240 volts, with two module matching with existing plate complete all as specified and directed. |
| 32 | S&F for shuttered socket outletmodular type6/16 Amps , 2/3 pin combined, 240 volts, with two module matching with existing plate complete all as specified and directed. |
| 33 | M&L forsub main wiring (Concealed) complete with 02 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi strandedduly colour coded cable drawn through and including concealed PVC conduit of size 32mm dia or above (medium grade) as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items of any types complete all as specified and directed.(Note : -(a) 02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC conduit and accessories shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).(b)Quoted rates shall be deemed to be inclueded for copper conductor cable, conduit & accessories and cutting,chasing, penning for concealed submain wiring n. exc 10 cm girth in brick wall/ concrete surfaces including making good the disturbed surfaces where required and pointing in cement mortar (1:3) with necessary matching existing colour duly putting etc. complete as directed.) |
| 34 | S&F for ceiling rose 3 phase, PVC/polycarbonate isolated body surface bakelite2 to 3 terminals fixed to wall/ceiling complete all as specified and directed. |
| 35 | S&F for High efficacy 2\"x2\" recess LED flat panel light fittings 36W LED 6000K edge-lit luminaire with in and including LED lamp suitable for armstrong/grid ceiling complete for low ceiling applications complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete as in repair all as specified and directed. (Make: Havells, Cat No. VENUSTREND2X2PLR36WLED865SWH or Crompton, Cat No. TCR-145-36-65-SL-NWH or equivalent in Philips) |
| 36 | M&L for sheet metal enclosure MCB distribution board, double door (metal) single pole and neutral with IP-30 and IK 09 protection single phase 240 volts 8 way, including suitable size copper bus bar of 200 amp and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:-MCBs will be measured separately.) |
| 37 | M&L for MCB, SPN, 240 volts, 40-63 amps with rupturing capacity 10 KA, \"C\" curve, including providing thimble for out going cables complete all as specified and directed. |
| 38 | M&L for MCB, SP, 240 volts, 5-32 amps with rupturing capacity 10 KA, \"C\" curve, including providing thimble for out going cables complete all as specified and directed. |
| 39 | S&F for modular white cover plate with frame, 2 module complete all as specified. |
| 40 | S&F for modular white cover plate with frame, 3 module complete all as specified. |
| 41 | S&F for modular white cover plate with frame, 6 module with blank switches as required complete all as specified. |
| 42 | Supply, installation, commissioning and testing hi wall split inverter type air conditioner (outdoor and indoor unit), electric driven single phase, AC, 220 volts complete with cordless remote control unit and with in-built air ioniser and plasma filter for better indoor quality with R32 refrigerant gas of 5 star rating and EER 3.2 of capacity 1.5 TR with fixing bracket of outdoor unit complete all as specified and directed by Engineer-In-Charge.(Note: (a) The contractor shall produced printed GST voucher to the Engr- In- Charge during payment claim. (b) Cost of angle iron bracket (2 Nos) for mounting of outdoor unit shall be deemed to be included in the unit rate)Make: Daikin/ Bluestar/ Hitachi/ Voltas |
| 43 | Supply and fix 16A-25A MCB SPN Protected Power Unit complete complete all as specified and directed.Make Siemens / Schneider /L&T/Legrand /GE Power / Havells |
| 44 | Supply, installation, testing of electronic wall mounting AC voltage stabilizer of 5 KVA capacity for fully automatic operation, single phase naturally air cooled indoor type and designed for working range between 170 volt to 280 volt with output voltage stabilized at 230 Volt capacities of accuracy +2.5%, time delay 3mts+/-20 sec ITDS.complete all as specified and directedMake: V-Guard /Volina/ Microtech/Vintec(Note:-The contractor shall produced printed GST voucher to the Engr- In- Charge during payment claim.) |
| 45 | S & F for 400mm sweep wall mounted fan complete with blades and accessories, 230V , minimum air dilevery 65CMM with service velue 6.00BE, five star rated including fixing clamp complete all as specified and directed. |