| 1 | Civil WorksEarth work in excavation in ordinary rock by mechanical means (Hydraulic excavator) means over areas exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on planincluding getting out and disposal of excavated material lead upto 50 m and lift upto 1.5m all specified and as directed by Engineer-in-charge. |
| 2 | Earth work in excavation in ordinary rock by mechanical means (Hydraulic excavator) in foundation trenches not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated material and disposal of surplus excavated material as directed within a lead of 50 m all specified and as directed by Engineer-in-charge |
| 3 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/ disintegrated rock all as specified and as directed. |
| 4 | Material and labour for hardcore with broken stone aggregate of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and rammed to a true surface all as specified and as directed. |
| 5 | Material and labour for 100mm thick plain cement concrete 1:4:8, type D-2,using 40mm graded stone aggregate as in sub base of flooring, finished even and fair etc complete all as specified and as directed. |
| 6 | Material and labour for chequered cement concrete colour tiles30 cm x 30 cm x 25 mm thick with grey cement andpigments, set, jointed and pointed in neat cement slurry in floors, steps etcover and including 20 mm thickscreed bed in cement mortar 1 :6 etc complete all as specified and as directed. |
| 7 | Material and labour for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 8 | Removing excavated material exceeding 250 m but not exceeding 500 m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and as directed. |
| 9 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm all as specified and as directed. |
| 10 | Material and labour for precast cement concrete block masonry with solid blocks made out of PCC 1:3:6, type C-1 with using 20mm graded stone aggregate, exceeding 10cm in width and setting in cement mortar 1:6 etc completeall as specified and as directed. |
| 11 | Material and labour for 15mm thick rendering with cement mortar 1:4 on brick or block masonry surfaces, finishedthe surfaces with even and smooth without using extra cement etc complete all as specified and as directed. |
| 12 | Material and labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces etc complete all as specified and as directed. |
| 13 | Material and labour for exterior grade, water resistant wall claddingceramic designer mosaic coloured tiles (Johnson Endura perl fin series or Equivalent) / stone panelsnot less than 8mm thick for vertical water fountain wall, suitable for continuous wet conditionset and jointed in polymer modified high bond grade must be approved for wet and vertical applicationswith uniform joints, before laying/ placing the tiles the wall shall be treatedwithtwo coats ofcementatious water proofing compounds etc complete all as specified and as direction of Engineer-in-Charge. |
| 14 | Material and labour for granite slab, 20mm thick, machine cut, in single piece or two piece length, table rubbed and polished, laid over and including 20mm thick cement screed in cement mortar 1:3, bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust and admixture of pigments to match with shade of granite stone as in cooking platforms, microwave platform, WHB counter topin steps, jambs, pillars, window-cills,etc, including cutting, polishing and rounding to edges of stone slabsetc., complete all as specified and as directed. |
| 15 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. |
| 16 | Supply and fix cascade wallwith brass/ SS nozzle/ lip straight or curved of standard sizefor water fall andfixed over granite/ wall tiles/ stone panelswith suitable adhesive or chemical andmust provide with uniform sheet like water flow and anti splash design suitable (pressure or head ) submergible or centrifugal pumbcapacity is based on lip size, with and including all necessary items such as piping, plumbing, recycling of water and bobbin wound filter dia 550mm with 2\"MPV & 3 Piece union suitable lighting arrangements also providedas per the direction of Engineer-in- Charge Note: Water fall height shall be considered up to 2.5m |
| 17 | Material and labour for plain cement concrete 1:2:4 , type B-1, with using 20 mm graded stone aggregate as in 50 mm thick floor, finished even and fair etc complete all as specified and as directed. |
| 18 | Supply and fix anti skid designer mosaic tile (Johnson Endura Neo pool series) suitable for submerged conditions/ water fountain not less than 8mm thickfixed in floor with tile adhesive (Manufacturer approved adhesive for submerged conditions) joints will be filled with water proofepoxy groutor rubber grout floatas per manufactures instruction etc complete all as specified and as directed. |
| 19 | Material and labour fordecorative, durable, weather resistantand maintenance free FRP French fence shall have the following specifications:-(a)Pickets of fence:FRP Rectangular/ spear top pickets, having minimum of 75mm -100mm wide and 20-25mm thick. Picket spacing 75-100mm (centre to centre).(b)Rails (Horizontals): FRP Rectangular rails shall be 75 to 45mmsize, top and bottom rails at 200mm - 250mm from top and bottom respectively.(c) Posts (Vertical):FRP square posts, minimum 100mm x 100mm in section, height 1200mm -1500mm above ground.(d) Decorative FRP Caps or finials: Integrally moulded or fixed with adhesiveandSS 304 fastenersor FRP bracketsto fix post and rails properlyNote: Necessary earth work excavation, PCC for foundation shall be measured and paid separately. |
| 20 | Supply and fixfor customised mural in multicolour in fibber glass (FRP) with water and weather resistant and durable complete all as specified and directed. |
| 21 | Supply and fix FRP benches with following specifications:-Material: Leg supports made with cast iron approx weight 45 To 50kg per benchSitting cum back Capacity: 2 to 3 persons of size 5\"(L) x 2.5\"(W ) x 2.5\"(H) to be approved by Engineer-in-charge. The equipment shall be fitted with in built limiters and shall be fixed on ground with plain cement concrete of minimum strength M-20 grade and J shaped welded bolts made of 18mm galvanized rod and when concrete is set, fixing the equipment on to it and cover nuts and bolts with base plate cover etc complete all as specified and directed. Note: Necessary earth work excavation and plain cement concrete shall be measured and paid separately |
| 22 | Supply and fix mild steel work in tubular trusses including special shaped washer etc. Complete using ERW or induction butt welded tubes conforming to I .S.1161-1979 grade st.240 complete all as specified and as directed. |
| 23 | Material and labour for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) with riveted, bolted or welded attachment conforming to Fe.410-W, Gde-E-250, quality \"A\" etc complete all as specified and as directed. |
| 24 | Material and labour for mild steel single stanchions of square hollow section with flange plates, caps, bases, splices, angle brackets, cleats and other connecting accessories conforming to Fe.410-W, Gde-E-250, quality \"A\" etc complete all as specified and as directed. |
| 25 | Material and labourfor preparing new steelsurfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red zinc chrome primer complete all as specified and as directed. |
| 26 | Supply and fix Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick as per approved profile of any colour having tensile strength of 550 Mpa as in roof covering/ on Chajjas, fixed with self tapping screws or L type or J type or cranked hook bolts or as per manufacture instruction complete all as specified and as directed by Engineer-in-Charge |
| 27 | Supply and fix Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick as per approved profile of any colour having tensile strength of 550 Mpa as in roof covering/ on Chajjas, fixed with self tapping screws or L type or J type or cranked hook bolts or as per manufacture instruction complete all as specified and as directed by Engineer-in-Charge |
| 28 | Material and labour for vitrified ceramic tiles, 8 to 10mm thick light shade colour (square/rectangular), area of each tile not exceeding 0.36 sqm, as in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to match overand including screed bed of 15mm thick in cement mortar 1:6 etc complete all as specified and as directed. |
| 29 | Material and labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement etc complete all as specified and as directed. |
| 30 | E/M WorksMaterial and labour for XLPE insulated, screened, PVC bedded, galvanised steel stripor wire, armoured, heavy duty electric cables with stranded aluminium conductor of size 2core x 10sqmm, 1100 volt grade, laid in trenches/ through GI Pipe/ fixed along with pole structure etc complete all as specified and as directed.Note : Necessary earthwork, cable protection items shall be measured & paid separately under relevant items |
| 31 | Removing excavated material to distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above starting point etc complete all as specified and as directed. |
| 32 | Material and labour for providing sand cushioning for protection of UG cable in trenches with river sand/ M sand including filling, spreading and punning down to desired thickness complete all as specified and as directed.Note:Punned thickness only will be measured and paid separately. |
| 33 | Supply and laying un-reinforced precast concrete cable cover, class LV, type1, flat, size 250 x 150 x 40mm in trenches for protection of UG Cable with width equal to length of PCC cover, laid dry & flat complete all as specified and as directed. |
| 34 | Supply and fix galvanised iron pipe light grade of bore 40mm for cable protection, laid in trenches, under road or fixing on wall/ pole/ crossing drain/ nallah etc. complete all as specified and as directed. |
| 35 | Supply and fix in LED outdoor lighting designed decorative hot dipped galvanised mild steel step pole of 3m with grey powder finish, Window - Plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories. Window cover is fitted with allen screws to the pole. Decorative sleek casting ring to increase aesthetical appealinand IP 65 protection with Lamp Post 35W New generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Clear Cover offers bright illumination for different applications complete all as specified and as directed. |
| 36 | Supply and fix in LED outdoor lighting Krypton Pro Integral high efficiency IP65 LED well glass luminaire with aluminium die cast housing and bowl shaped polycarbonate diffuser, offering potential for high energy saving over conventional luminaireswith provided all accessories required on site for hanging of light with conduit pipe for wiringcomplete all as specified and as directed. |
| 37 | Supply and fix in MCB distribution board, single door CRCA steel sheet enclosure powder coated, SPN 4 Way as in replacement with 200 Amp rated shrouded copper busbar for each phase, fully insulated and shrouded neutral bar, earth bar, wire set and cable ties for cable management, IP 43 and IK 09 protection with reversible metal door with provision for MCB/ Isolator/ RCCB/ RCBOas incomer and SP MCBs as outgoing complete all as specified and as directed. Note: MCBs shall be measured and paid in separate items. |
| 38 | Supply and fix in MCB SPN 40A, 240 Volt, 10 KA \"C\" curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DBwith connection testing and commissioning. Complete all as specified and as directed. |
| 39 | Supply and fix in MCB SP 6-32A, 240V, 10 KA \"C\" curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning. Complete all as specified and as directed. |
| 40 | Material and labour for submain wiring completewith and including3 runs of 1.5 sqmm,single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including non metallic PVC conduit of suitable size including accessories etc as required and fixed on walls and 2runs of 1.5 sqmm FRLS, PVC multistranded copper conductor cable for earthing and connected to common earth dollycomplete all as specified and as directed by Engineer-in-Charge.Note :Three runs of 1.5 sqmm PVC insulated cable and Two runs of 1.5 sqmm cable and one run of PVC conduit shall be measured as one unit length. |
| 41 | Supply and lay in trenches galvanised iron pipe medium grade of bore 50mm including all fittings etc. complete all as specified and as directed. |
| 42 | Supply and fix CPVC pipe 32 mm outer dia SDR 11 with CPVC SDR 11 fittings fixed on walls/ ceiling or laying in trenches etc complete all as specified and as directed. |
| 43 | Material and Labour for CPVC ball valve of size 32mm outer dia complete all as specified and as directed |
| 44 | Supply and fix in Gun metal, globe or gate valves 50 mm dia, with ironwheel head, screwed both endsfor iron pipe and fixed complete all as specified and as directed |
| 45 | Supply and fix in 1 inch brass adjustable fountain nozzle suitable for fountain complete all as specified and as directed. |
| 46 | Supply and fixin LED underwater light 18 W suitable for application in fountain with minimum IP67 ingress protection, SS body 304 grade with RGB colour scheme including suitable RGB driver with all accessories internally pre-wired and including connecting up with twin core waterproof PVC copper wire round / flat with 1 sqmm conductor complete all as specified and as directed. |
| 47 | Supply and fix in under water openwell submersible pump set 3 HP capacity of head upto 10M and discharge not less than 90 LPM. No need of priming and footwall with provision of easy installation on foundation platform. The pump should have CI impeller and SS shaft suitable for 3 phase 440V, 50Hz operation including DOL/ submersible starter panel of minimum 3 HP capacity mounted in weather proof casing made out of GI thickness not less than 3mm of size 3mm of size 300mm x 50 mm and IP54 rating complete all as specified and as directed. |
| 48 | Supply, lay and test of PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm ,3 core, 1100 Volts grade complete all as specified and as directed. |
| 49 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and as directed. |
| 50 | Material and labour for LT Panel board with CPRI APPROVED factoryfabricated, TPN 415 Volts, 50 Hz, Bus bar of 200 Amps capacity placed horizontally throughout the width of Panel, outdoor cubical type floormountedfactory made double doordust and vermin prooffabricatedout of CRCA sheet not less than 3.15 mm thickfixed on angle ironframemade out of 50 x 50 x 6 mm with height of legs is 0.75 m (0.3m under the ground) and 0.45mabove ground with cable chamberfor individual feeders for incomingand outgoing connections, one set of LED indicator lampRYB with switch and fuse,Voltmeter, Ammeter etc complete all as specified and as directed with the followings Accessories :-INCOMING:-(a)MCCB with fixed thermal and magneticrelease 4P, 40 Amps 415 V, 16 KA - 01 Nos (Incoming)(b) MCB TPN 32 Amps , 415 V, 16 KA - 02 NosOUTGOINGS:-(a) MCB SPN, 32 Amps 240 Volts, 10 KA - 04 No (Spare 1No.)(b) Pump Starter ofcapacity 2.5 HP - 01 No.(c) Analog Time Switch with contactor -01 No. |
| 51 | Material and labour for Earthing complete with using GI earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using galvanised iron wire 4mm dia as earthing lead moulded and retrieved to earth plate at one end and connected to main switch / control board at another end with and including 40 mm dia GI light grade from upper end of earth plateupto external faceof the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provision of PCC 1:2:4 type B-1 (Using 20 mm graded stone aggregate) duly reinforced with mild steel round bar 8 mm dia@ 150 mm c/c both ways with 10 mm dia mild steel bars as in liftinghandle with and including necessary excavation and earth work including laying the pipe concealed in floor / wall all as per plate No.5 of SSR Part-I complete all as specified and as directed including testing on completion Note: If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt. |