| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5m wideand depth exc. 1.5m but not exceeding 3.0mfor laying electric cables, pipes, polesetc and getting out in soft/loose soilcomplete all as specified and directed. |
| 3 | Returning, fillingin, including spreading, leveling watering and well ramming in layers not exc 25 cm with excavated soil complete all as specified and directed. |
| 4 | Removing excavatedmaterial soils, not exc 50m and depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed. |
| 5 | Taking down or taking up steel water tubing , galvanisedfrom trenches / walls / floors including all fittings, segregatting and stacking the serviceable pipes and fittings properly at site for re-use all as specified and directed for following bore of pipe:- NoteExcavation and earth work shall be meassured and paid under relevant item of schedule separately. |
| 6 | 15 mm dia |
| 7 | 20 mm dia |
| 8 | 25 mm dia |
| 9 | 40 mm dia |
| 10 | 50 mm dia |
| 11 | 80 mm dia |
| 12 | 100 mm dia |
| 13 | Re-laying/refixing onlyoldserviceable steel water tubing, galvanised and connections in new or old situation / allignment including all new fittings (on Walls, floors,trenches etc, ) of pipeas recovered under item Ser No.4 ( a )to 4 (b) above including de-scaling /cleaning of pipe (internally and externally) cutting and threading of tubing ends all as specified and directed. of following size :- |
| 14 | 15 mm dia |
| 15 | 20 mm dia |
| 16 | 25 mm dia |
| 17 | 40 mm dia |
| 18 | 50 mm dia |
| 19 | 80 mm dia |
| 20 | 100 mm dia |
| 21 | S & F steel water tubing galvanised ,medium grade with all fittings and fixed complete to walls ,orin floors,in old/new situation for bore of pipefollowingsizes:- |
| 22 | 15 mm dia |
| 23 | 20 mm dia |
| 24 | 25 mm dia |
| 25 | 40 mm dia |
| 26 | 50 mm dia |
| 27 | All as per item No 7 above but laid in trench of folliwng bore of pipe:- |
| 28 | 15 mm dia |
| 29 | 20 mm dia |
| 30 | 25 mm dia |
| 31 | 40 mm dia |
| 32 | 50 mm dia |
| 33 | 80 mm dia |
| 34 | 100 mm dia |
| 35 | S & F in repair gate / globe valves cast copper alloy screwed both end down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed bore of following size:- |
| 36 | 20 mm bore |
| 37 | 25 mm bore |
| 38 | 40 mm bore |
| 39 | 50 mm bore |
| 40 | M&L pre-cast reinforced cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in manhole covers including placing the cover in position and set in cement mortar (1:6) complete all as specified and directed. Note: Reinforcement shall be measured and paid seperately. |
| 41 | Construction of brick masonry valve pits of size 120 cm x 120 cm x 120 cm (internal dimension) complete and fabrication of M S cover made out of 3 mm thick MS sheet and angle iron frame made out of 40 mm x 40 mm x 6 mm thick and one side provided with hinges and another side provided with locking arrangement including dismantling the existing unserviceable valve pit including excavation complete all as specified and as directed. |
| 42 | Allas per item No11 here in before but 100cm x 100cm x 100cm -do-. |
| 43 | Allas per item No11 here in before but 90cm x 90cm x 90cm -do-. |
| 44 | Repair to existing cast iron pipe line in position by cutting of existing cast iron pipe line in position of required sizes for insertion of new tees branches, repairs to existing lines etc complete of the following bores:- |
| 45 | 80 mm dia |
| 46 | 100 mm dia |
| 47 | 150 mm dia |
| 48 | 200 mm dia |
| 49 | 250 mm dia |
| 50 | M&L Rubber gasket tyton joints suitable for spigot and socket cast iron pipe and fittings of following size complete. |
| 51 | 80 mm bore |
| 52 | 100 mm bore |
| 53 | 150 mm bore |
| 54 | 200 mm bore |
| 55 | 250 mm bore |
| 56 | Note: Excavation will be measured and paid seprately. |
| 57 | M&L Joints to flanged pipes and fittings with rubber or fibre board gasket including provision of bolts, nuts, washers and white lead or mineral oil complete for the following bores :- |
| 58 | 80 mm bore. |
| 59 | 100 mm bore. |
| 60 | 150 mm bore |
| 61 | 200 mm bore. |
| 62 | 250 mm bore. |
| 63 | Note. Excavation/Earthwork will be measured and paid seprately. |
| 64 | M&L Repairing leaking joints in existing cast iron water mains (lines) in position by providing extra lead wool caulking to make it leak proof including dewatering of trenches for the following bore of pipes :- |
| 65 | 80 mm bore |
| 66 | 100 mm bore |
| 67 | 150 mm bore |
| 68 | 200 mm bore |
| 69 | 250 mm bore |
| 70 | Note. Excavation will be measured and paid seprately. |
| 71 | S&F CI/DI Joint including all accessories nut bolt washer complete including dewatering of trenches for the following bore of pipes:- |
| 72 | 80 mm bore |
| 73 | 100 mm bore |
| 74 | 150 mm bore |
| 75 | 200 mm bore |
| 76 | 250 mm bore |
| 77 | S&F J P Joint including all accessories nut bolt washer complete including dewatering of trenches for the following bore of pipes:- |
| 78 | 80 mm bore |
| 79 | 100 mm bore |
| 80 | 150 mm bore |
| 81 | 200 mm bore |
| 82 | 250 mm bore |
| 83 | S&F in replacement of CI Non return valve of following sizes :- |
| 84 | 80 mm bore |
| 85 | 100 mm bore |
| 86 | 150 mm bore |
| 87 | 200 mm bore |
| 88 | Taking up or down cast iron water mains (including all fittings), with spigot and socket ends and lead joint including buning out joints and recovering lead complete all as specified and directed for the following sizes :- |
| 89 | 100 mm bore |
| 90 | 150 mm bore |
| 91 | 200 mm bore |
| 92 | 250 mm bore |
| 93 | M&L for Ductile Iron (DI) pipe Class K-9, ISI marked (IS 8329) of following bores:- |
| 94 | 100 mm bore |
| 95 | 150 mm bore |
| 96 | 200 mm bore |
| 97 | 250 mm bore |
| 98 | Supply and fix sluice valve of followingsize / bore, all as IS -14846-2000 PN 1.6with gun metal spindle both ends flanged and drilled with necessary holes for bolts including jointing materials viz nuts, bolts, rubber gaskets etc with iron wheel head including flange joints and making necessary arrangements to fix in position complete all as specified and directed. |
| 99 | 80 mm bore |
| 100 | 100 mm bore |
| 101 | 150 mm bore |
| 102 | 200 mm bore |
| 103 | 250 mm bore |
| 104 | Cutting of existing road for laying /passing through CI Pipe line 80 to 100 mm bore including necessary excavation, returning filling in hard soil material to a distance not exceeding 100mtrs and making good disturbed surface with existing one after laying of pipe line all as directed by Engr-in-Charge. |
| 105 | M&L Fittings for spigot socketed cast iron pipes 80 to 300 mm bore such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, single branch, `Y\" junction, double branch, cross (all sockets or socket and spigot), collars, caps ,plugs and JP/D Joint complete all as specified and directed by Engr-in-charge.. |
| 106 | M&L for making foundation thrust blocks/support pillars for holding pipe line/clamp support etc by PCC 1:2:4 type B1 (using 20mm graded aggregate size) and using extra cement making good to surfaces complete. |
| 107 | S&F in repairBib taps, cast copper alloy with crutch orbutterfly handle of size 15 mm bore,screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified by Engr-in-charge. |
| 108 | S&F in repairBib taps, cast copper alloy with crutch orbutterfly handle of size 20 mm bore,screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified by Engr-in-charge. |
| 109 | M&L for plain cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed. |
| 110 | M&L for cement concrete (1:2:4), type B-1, using 20mm graded stone aggregate in window cills, lintel band, bed block, copings and the like including weathering, slightly rounded or chamfered angles and throating, Including necessary form work complete all as specified and directed. |
| 111 | S&F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe 410-W (Gde-E-250) quality-complete all as specified and directed. |
| 112 | M& L for repair of Sluice Valve Spindle made out of stainless steel including adequate size of spindle nut made of SS of following size as per sample all as per directed by Engineer in Charge |
| 113 | 80mm/100mm bore |
| 114 | 150mm /200 mm bore |
| 115 | Repair / Maintenance of Decrin Dozer and replacing defective parts / spares including testing and commissioning complete as directed by Engineer-in-Charge and parts shall be measured & paid as given below :-Note: Quoted rates for spare parts are inclusive of repair / replacement of Decrin Dozer including its replacement. |
| 116 | Roller assembly (PK-4) |
| 117 | Pump tube (PK-5) |
| 118 | Weighted suction line strainer 3/8\" |
| 119 | 3/8\" white suction / discharge tube |
| 120 | Check valve duckbill only (PK-5) |
| 121 | Connecting nut 3/8\" |
| 122 | Connecting nut 3/8\" with adapter (PK-5) |
| 123 | GI fitting for Doser including gate valve of 15 mm dia |
| 124 | NRV suitable for decrin Dozer |
| 125 | UPVC pipe of 15 mm dia |
| 126 | Taking down CI Sluice valve of following sizes :- |
| 127 | (a) 80 mm dia |
| 128 | (b) 100 mm Dia |
| 129 | (c) 150 mm Dia |
| 130 | (d) 200 mm Dia |
| 131 | Supply and fix in repairs, integral LED aviation light comprising of Die-cast aluminium housing with Red polycarbonate dome for better illumination, integral driver, super flux 5mm 302 Nos LEDs incorporated, IP-65 with and including 0.60m long medium grade GI pipe of suitable dia & necessary clamps of suitable size if required and PCC coping as per site requirement in PCC 1:2:4 type B2 using 12.5mm graded stone aggregate and connecting up with & including two runs of single core PVC insulated, sheathed, mutistranded copper conductor cable of size 1.5 Sqmm drawn in and including rigid PVC conduit heavy grade ISI marked not less than 20mm width with its accessories from light to DB (near bottom of OHT) complete all as specified & directed. |
| 132 | Supply and fix water level indicator in repairs at OHT in existing position with MS/GI float of 300mm dia & 400mm long, hollow box of 16 gauge copper sheet fixed to stranded steel wire rope of required length including brass pullies with nylon bush and 50x50x6mm angle iron brackets for pullies, indicator board shall be of 10 gauge of MS plate 200mm wide fixed on angle iron frame 30x30x5mm with angle iron stiffners and after preparation of surfaces, board shall be painted with two coats of synthetic enamel paint over & including a coat of red oxide primer & marking of levels on front face of board with black synthetic enamel paint as per existing pattern or as directed by Engr-in-Charge including all necessary fixing arrangements for fixing of level indicator board as per site requirements complete all as specified and directed. Notes: (i)Quoted rate shall be deemed to be inclusive of all materials & labours, all tools/plants, scaffolding with steel props for working upto approximate 25 M height as per site conditions and as directed. (ii)It shall be prime responsibility of the firm / contractor to provide all necessary safety arrangements like safety belts, ropes, helmets, netting etc to all workers for their safety at working site for work at any height and during working hours, if any casualty happened, only firm / contractor shall be responsible for the same and Government shall not be responsible for any compensation to workers or any other liability but firm\"s / contractor\"s quoted rates shall be deemed to be inclusive all these aspects. |
| 133 | S & F in repairs including connecting and commissioning of MU - G20 fully automatic submersible pump star delta starter relay range 28 - 42 A in sheet metal enclosure conforming to IS/IEC60947-41, protection offered overload, single phasing, phase reversal & imbalance, auto restart features, vibration proof enclosure with IP 54 protection class, indication offered ON/OFF, voltage and ampere complete all as specified and directed. |
| 134 | S & F in repairs including connecting and commissioning of MU - G30 fully automatic submersiblepump star delta starter relay range 30-50 A in sheet metal enclosure conforming to IS/IEC60947-41, protection offered overload, single phasing, phase reversal & imbalance, auto restart features, vibration proof enclosure with IP 54 protection class, indication offered ON/OFF, voltage and ampere complete all as specified and directed. |
| 135 | S & F in repairs including connecting and commissioning of MU - G50 fully automatic submersiblepump star delta starter relay range 30-50 A in sheet metal enclosure conforming to IS/IEC60947-41, protection offered overload, single phasing, phase reversal & imbalance, auto restart features, vibration proof enclosure with IP 54 protection class, indication offered ON/OFF, voltage and ampere complete all as specified and directed. |
| 136 | Material & labour for cleaning away all grass vegetation, scalping shrubs bushes under growth roots and trees upto zero level not exceeding 30 cm girth and removing rubbish upto distance of 50 mtr out the periphery of area under cleanness complete with tractor/JCB plants all as specified and directed. |
| 137 | Material and labour rubber gas kit of suitable size as per samplefor fixingin sluice valve, NRV, flanges etccomplete all as specified and as directed. |
| 138 | M & Lin replacementstrainer of Footvalve for 100 mm bore, ISI marked complete all as specified and directed. |
| 139 | S & F in replacement ofMS Nut bolts machine made with hexagonal or square head at one end screwed the other, each screws and to be fitted with washers and nut, exc 5 cm but not exc 10 cm long and dia of bolt 10cm complete all as specified and directed. |
| 140 | S & F in replacement change over switch 4 pole 315 Amp, 415 Volts, ON load type, front handle type with enclosure including connection, testing and including taking down of existing changeover switch complete all as specified and directed. |
| 141 | Taking out MCCB of follwing sizes:- |
| 142 | (a) 63 Amps, 415 Volts |
| 143 | (b) 100 Amps, 415 Volts |
| 144 | (c) 160 Amps, 415 Volts |
| 145 | (d) 250 Amps, 415 Volts |
| 146 | (e) 400 Amps, 415 Volts |
| 147 | S & F in replacement MCCB 4 pole 63 Amps,415 voltsrupturing capacity 16KA, adjustable type incl thimbal on LT panel/feeder pillar boxas per site requirement complete all as specified and as directed. |
| 148 | Supply and fixing in replacement MCCB 4 pole 100 Amps,415 voltsrupturing capacity 16KA, adjustable typeincl thimbal on LT panel/feeder pillar box as per site requirement complete all as specified and directed |
| 149 | Supply and fixing in replacement MCCB 4 pole 160 Amps, 415 voltsrupturing capacity 25KA, adjustable typeincl thimbal on LT panel/feeder pillar box as per site requirement complete all as specified and directed |
| 150 | Supply and fixing in replacement MCCB 4 pole 250 Amps, 415 voltsrupturing capacity 25KA, adjustable type on LT panel/feeder pillar box as per site requirementcomplete all as specified and directed |
| 151 | Supply and fixing in replacement MCCB 4 pole 400 Amps, 415 voltsrupturing capacity 35KA, adjustable type on LT panel/feeder pillar box as per Site requirement complete all as specified and directed Note for items 46 to 50 :-Suitable cable lugs and necessary minormodifications such as making additional holes / cutting slotsetc in the existing panelif found requiredfor fixing the MCCB it shall be carried out without additional rate and rate for which shall deemed to be included in the above quoted rate. |
| 152 | Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core including taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etccomplete all asspecified & directed. |
| 153 | Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 coreincluding taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all asspecified & directed. |
| 154 | Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 coreincluding taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all asspecified & directed. |
| 155 | Supply, laying or fixing or passing through pipe commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 coreincluding taking down/out old UNSV cable from trenches/ducts/from pole/wall removing from site etc complete all asspecified & directed. |
| 156 | M & L for Sub main wiring with two single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade with 6 sqmm drawn through suitable size of non-metallic PVC conduit with one run of 6 sqmm copper conductor FRLS cable as earth conductor and conduit accessories fixed up in surface/recessed as required, including connecting up complete all as specified and directed.NOTE:- Three runs of 6 sqmm cable and one run of PVC conduit shall be measured as one unit. |
| 157 | M & L for Sub main wiring with two single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade with 10 sqmm drawn through suitable size of non-metallic PVC conduit with one run of 10 sqmm copper conductor FRLS cable as earth conductor and conduit accessories fixed up in surface/recessed as required, including connecting up complete all as specified and directed.NOTE:- Three runs of 10 sqmm cable and one run of PVC conduit shall be measured as one unit. |
| 158 | S&F in repairs PVC Insulated and PVC sheathed Industrial 3 Core Flat Submersible cable 6 sqmm with bare bunched copper conductor for submersible pump motor with voltage grade 1100 volts as per IS 694/1990including jointing connecting with submersible motor to starter including removing old submersible cable complete all as specified and directed. |
| 159 | S&F in repairsPVC Insulated and PVC sheathed Industrial 3 Core Flat Submersible cable 10 sqmm with bare bunched copper conductor for submersible pump motor with voltage grade 1100 volts as per IS 694/1990including jointing, connecting with submersible motor to starter including removing old submersible cable complete all as specified and directed. |
| 160 | Supply & lowering of GI heavy duty column pipe 80mm (3\" bore), C grade 3 Mtr long in bore well including all cutting and threading both end ISI marked with heavy duty 100mm long thread for lowering all as specified and directed. |
| 161 | Supply & lowering of GI heavy duty column pipe 100mm (4\" bore), C grade 3 Mtr long in bore well including all cutting and threading both end ISI marked with heavy duty100mm long thread for lowering all as specified and directed. |
| 162 | Cutting and threading 80mm (3\" bore) both end MS / GI column pipe heave duty 3 Mtr longincluding new socket 80mm bore 100 mm long complete all as specified and directed. |
| 163 | Cutting and threading 100mm (4\" bore) both end MS / GI column pipe heave duty 3 Mtr longincluding new socket 100mm long ISI marked with heavy duty complete all as specified and directed. |
| 164 | M & L for Flushing out/ desilting of borewell by using compressure hydropressure jet till clear the silt in the casing pipe by the achieving clear water and washing with hydropressure jet using foam/ oil, disinfecting of the bore using sodium hydroclolide solution and washing out up to 6 hrs till water is obtained to the required turbidity(clean water) to the entire satisfaction of Engr-in-Charge. |
| 165 | Supplying, Hoisting and fixing in position and connecting, in repairs, 500 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top thred type) 3 Layers including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed. |
| 166 | Supplying, Hoisting and fixing in position and connecting, in repairs, 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top thred type)3 Layersincluding fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed. |
| 167 | Supplying, fixing & Hoisting and fixingin position and connecting, in repairs, 2000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top thred type) 3Layers including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed. |
| 168 | Supplying, fixing & Hoisting and fixingin position and connecting, in repairs, 5000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top thred type) 3Layers including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed. |
| 169 | S & F in repair, 15mm bore, float valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed (Minimum weight - 142 Gms). |
| 170 | S & F in repair of 20mm bore, float valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed (Minimum weight - 210 Gms). |
| 171 | S & F in repair of25mm bore, float valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed (Minimum weight - 690 Gms) |
| 172 | M & L in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10W, 6500K, 220 V, AC decorative type with extruded polycarbonate, environment friendly, energy efficient including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to LED fitting complete all as specified and directed. |
| 173 | M & L in replacement of LED light fitting 1 x 20W, 220, high performance batten. This LED luminaire comprises of extruded channel in thermally conductive material. High translucent serrated milky white diffusers used to get glare free and smooth light distribution. Efficacy 100lm/W, natural white, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to LED fitting complete all as specified and directed. |
| 174 | M & L Galvanised Iron pipes, light grade, 40mm diawith all fitting and fixed to poles/route/drains or ceillings or laid in floors all as specified and as directed. |
| 175 | M & L Cutting the tar macadam road / hard standings for laying cable and excavating not exceeding 0.45m wide and 0.75m indepth including filing back, watering, well ramming and finishing it with 200mm thick PCC 1:4:8 type D-2 completeall as specified and as directed. |
| 176 | M& L of repairing/ welding of pipe/ fitting of size 80 to 200mm including excavation in soft/dense soil & taking up pipe/fitting of size 80 to 200 mm dia GI/PVC cutting, rethreading/jointing the pipe and replacing unserviceable fitting returning and filling the excavated soil and testing the joint.Note:- Necessary Excavation upto 0.60 cum shall be included in the job complete all as specified and directed. |
| 177 | M & L for painting with approved colour to existing MS/GI pipe (raising main delivery over flow and wash out) of size 100/150/200mm dia 30 mtr height over head tank with two coat of synthetic enamelled paint including scrapping out old paint all as directed. Note:- All T & P, 30 mtr staging mtrl and men power risk shall contractor responsibility. |
| 178 | Supply / Fixing / Erecting in replacement of steel tubular poles complete with cast iron base plate, finial taper plug, bolts Nuts & screws complete all as specified type 410 SP-31 of 9 mtrlong including painting of pole with one coat red oxide primer & two coats of aluminum paint & emedded portion shall be painted with two coat of black bituminous paint all as specified in IS and all as shown in drawing No CEJZ/TD/824/91, Sheet No1/2 dt 16.04.91 and writing pole no with yellow shade on black base using synthetic enamel paint having height of works exc 5 cm as directed by Engr-in-Charge :-Note:- PCC, Foundation wk and excavation, removal and returing filling will be paid and measured seperately. |
| 179 | M& L for providing cement concrete PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate) as in pillars, plate forms, beds and coping around poles etc complete including necessary formwork and finishing the exposed surfaces even and smooth without using extra cement all as specified and as directed. |
| 180 | S & F Street light fitting 45 watt, pressure die cast housing, toughened glass, high power LEDs with secondary optics, IP-66 protection including necessary fixing arrangement i.e. suitable sizebracket made to shape of 40 mm dia GI pipe medium grade of 1.4 mtr length including MS clamps 25 x 4 mm - 02 Nos with nut bolts washers etc including taking down Old US fitting all as specified and directed. |
| 181 | S & F Flood light fittings 100 Wattwith pressure die cast aluminium housing, toughened glass and high power LEDs, secondary lenses, IP-66 protection, surge protector device 10 KV, with all accessories & necessary fixing arrangement i.e. GI clamps, nuts bolts and washers etcincluding taking down old unserviceable fitting allas specified & directed. |
| 182 | Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 200 x 160 x 98 mm, 5 way having terminals for termination of cable with necessary nuts and bolts, Make - Hansal including -02 Nos polycarbonate cable glandMake : Hansal, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 16 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any typeall as directed. |
| 183 | Material and labour in replacement control wiring / motor starter wiring of pump motor starter panel with PVC insulated copper contactor of sizes 2.5mm/4sqmm all as specified and directed. |
| 184 | S & F in replacement, air termination, single pointed Aluminium rod 12mm dia and 300 mm long with two Nos brass nut, bolt and washers to existing/new lightening conductor system complete all as specified and directed. |
| 185 | S & F in replacement, aluminium strip of size 32x6mm with and inclduling saddles and fixing etc and jointing of strips with suitable size of nut, bolt and washers for roof conductors and down conductors above ground complete all as specified and directed. |
| 186 | M & L for test point made by phosphorus bronze / gunmetal of size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm hex head screw complete with saddles and fixing screws for fitting the strips complete all as specified and directed. |
| 187 | M & L in replacement of gland packing of size 10/15/20 mm (Each roll 6 mtr length) complete all as specifed and directed |
| 188 | Supply and fixing of High intensity HIP reflective sign board made from hardened plastic aluminium combined sheet 2 mm thick (with high quality lamination), two sheets placed back to back aluminium pop riveted to stainless steel square pipe 40 x 40 mm of 16 gauge, frame of size 1300 x 840 mm. Frame supported with 25 mm and 50 mm round 2700mm long stainless steel pipe of 16 gauge welded to frame. Top end of legs closed with decorative stainless steel dome place. All stainless steel parts polished on plastic aluminium combined sheet, HIP blue reflective sheet shall be pasted on both side and with white fluorescent computer cut tape minimum 110mm height to be pasted on sign board and border of white HIP sheet shall be pasted and fixed in PCC (1:2:4) type B1 including dismantling existing old vintage damaged standing sign board, complete all as specified and directed by Engr-in-Charge. |
| 189 | Supply and laying well burnt sub class B bricks old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed. |
| 190 | Supply and spread river sand for cable cushioning in trenches all as specified in clause 19.75 of SSR Part-I. |
| 191 | M & L in repair for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50 M deep below normal ground level, connected to galvanisedstrip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe medium grade including necessary fittings for protection of earthing strip upto 7.5 mtr length, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed. |
| 192 | Schedule of credit amount of Rs. 3,97,660.00 to be deducted during AOC |