| 1 | Maintenance of electrical fittings installed in office complex, Toilet blocks & site offices of various parks/greens under HD-1 by deploying required staff & all T&P as per additional conditions attached. |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable in surface/ recessed PVC medium class conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.a) Group A |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.a) Group A |
| 4 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group A |
| 5 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 6 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 7 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFRPVCinsulatedcopperconductorsingle corecableinsurface/recessedmediumclassPVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 8 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm |
| 9 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 10 | 3 Module (100mmX75mm |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 12 | 5/6 amps switch |
| 13 | 15/16 A switch |
| 14 | 3 pin 5/6 A socket outlet |
| 15 | 6 pin 15/16 A socket outlet |
| 16 | Supplying and fixing following piano type switch/socket on the existing switch box/ cover including connections etc. as required. |
| 17 | 5/6 amps switch |
| 18 | 15/16 A switch |
| 19 | 3 pin 5/6 A socket outlet |
| 20 | 6 pin 15/16 A socket outlet |
| 21 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in theexistingsurface/recessedsteel/PVCconduitas required.a) 3 x 1.5 sq. mm |
| 22 | b) 3 x 4 sq. mm |
| 23 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 24 | Supplyingandfixingfollowingway,singlepoleand neutral,sheetsteel,MCBdistributionboard,240V, onsurface/recess,completewithtinnedcopperbus bar, neutral bus bar, earth bar, din bar, interconnections,powderpaintedincludingearthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door |
| 25 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | Single pole |
| 27 | Double pole |
| 28 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/ coke and salt as required. |
| 29 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 30 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 31 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 32 | 18-22 Watt |
| 33 | 40 Watt |
| 34 | Supply, replacement, testing & commissioning of ceilingfanwithBrushLessDirectCurrent(BLDC) Motor,classofinsulation:B,3nos.metal(Aluminium alloy)blades,30cmlongdownrod,2nos.canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as perIS:374-2019),THD(TotalHarmonicDistortion) lessthan10%,remote(preferablymobileappbased) for speed control and all remaining accessories includingsafetypin,nutbolts,washers,temperature rise=750C(max.),insulationresistancemorethan2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supplyCeilingFancomplianttoIS374:2019fani/c external connections with 1.5 sq.mm FRLS/HFFR, PVCinsulatedcopperconductorsinglecorecable andearthingetc.asrequired i/c rebate for dismantle material. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 35 | Supply ofenergy efficient Plastic body/metal body exhaust fan of following size of following air delivery at rated RPM to operate on single phase 230 volt, 50 HZ AC Supply with aerodynamically designed & Balanced Blade/impeller, copper windingwith bird guard to protect the fan in running condition, arm-set, frame and all required accessories as per site condition |
| 36 | 300 mm sweep with minimum air delivery of 1000 cubic meter per hour |
| 37 | 250 mm sweep with minimum air delivery of 700 cubic meter per hour |
| 38 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 39 | Rewinding of ceiling fan i/c varnishing, oiling, greasing, bearing replacement, 2.5-4 mfd capacitor replacements, testing, commissioning i/c removing & re-fixing in the same position etc. complete as reqd. |
| 40 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 41 | Supply of XLPE insulated & PVC sheathedarmoured aluminum conductorpower cable of 1.1 KVgrade confrming to IS :7098 (Part 1) i/c testingetc complete as reqd. |
| 42 | 3Cx10 Sq.mm. |
| 43 | Laying of one number PVC insulated and PVC sheeted/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/Metal/DWC/HDPE pipe as required. |
| 44 | Up to 35 Sq.mm |
| 45 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 46 | Supply ofenergy efficient high speed wall fan of 400 mm sweep size minimum air delivery 60 CMM at rated RPM suitable to operate on single phase 230 volt, 50 HZ AC, Supply with aerodynamically designed & Balanced ABS Blade, copper winding, 3 Speed Regulation, Built in Thermal Overload Protector, Jerk Free & Smooth Oscillation, Powder coated metal wire fan guard material, suitable Length of Cord with Suitable Plug top, Bracket mounting accessories for Wall mounting, Guard Set, Guard Ring, frame etc complete as required. |
| 47 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 48 | Supply of energy efficient (Minimum 3 star BEE rating) 9/10 watt LED bulb B22 base suitable to operate on 230 V 50 Hz AC Supply with lumens output not less than 850 Lm, Lamp Life Hours 15000, CRI> 80, Rated Efficacy> 90, In Built Surge Protection 4 KV etc complete as required. |
| 49 | SITC of 10 watt LED Bulkheadpolycarbonate housing, High efficiency long life LED module,integral electronic LED driver with Output short/open circuit Protection and 3.5kV inbuilt surge protection, Wall/ceiling mounted by means of SS screws on Bulkhead housing, THD < 10% , P. F.≥0.95, IP not less than 54, CRI ≥80, lumens not less than 800. |