| 1 | ABC |
| 2 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt ) as required. |
| 3 | Providing and fixing 6 SWG dia G.I. wire on surface or in recessfor loop earthing as required. |
| 4 | Providing and fixing 25 mmX5 mm G.I. Strip on surface or in recess for connection etc. as required |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 Sq mm |
| 6 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as requiredUpto 35 Sq mm |
| 7 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 8 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 9 | Supply of XLPE insulated PVC sheathed AL. conductor armoured Cable 1.1 KV grade conforming to IS-7098 of following size- (a) 2X6 Sq mm |
| 10 | Supplying,installation,Testing&Commissioningof40 watt StreetlightLEDfixture powdercoatedpressurediecastaluminumbody withdriver as per the requirement with Driver efficiency >85%,Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5KVL,N,EasperIEC61000-4-5,Driver efficiency >85%,THD< 10%asperIEC61000-3-2,P. F.≥0.95,IP 66,IK-10,CRI>80,undervoltageandovervoltageprotection,EMI EMCAsper CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry)ofminimum 50000BurningHourswith70%ofinitial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K(AsperANSIBin),SDCM(Standard Deviation Color Matching) <5,Maximumpowerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standardcompleteinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy>135 lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise |
| 11 | Fabrication , supplying and fixing class B galvanised single overhang arm bracket made out of 250 mm long galvanised top tube with cap and 250 mm long 32 mm dia galvanised pipe with tightening bolts complete as required |
| 12 | Fabrication , supplying and fixing class B galvanised double overhang arm bracket made out of 250 mm long galvanised top tube with cap and 250 mm long 32 mm dia galvanised pipe with tightening bolts complete as required |
| 13 | Supply of PVC insulated and FR PVC sheathed multicore copper conductor 1.1. kv grade conforming to IS694 as reqd:-3x1.5 sqmm |
| 14 | Supplying, installation, Testing&Commissioningof100 watt FloodLight,powdercoatedpressuredie cast aluminumbody withbuiltinor separate driver as per the requirement with Driverefficiency>85%,Inputvoltage:Input voltage:140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-45, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95,IP66,IK-10,CRI>80,undervoltageandovervoltageprotection, EMIEMCasper CISPR -15 ,lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K(AsperANSIBin),SDCM(Standard Deviation Color Matching) <5,Maximumpowerconsumptionshouldnotmore than the specified rating and Fixture shall be ofrelevant BIS standardcompleteinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C) |
| 15 | Fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate window with flash cover with full vertical window cover at appropriate height form the base plate on existing cement concrete predestal as required i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4mm thick of suitable length and having suitable size tapped holes as reqd. terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel of suitable length ,6 Amp SPMCB \"C\" characherstics earth stud cable support clamp suitable for upto 4X25 sq mm cable Logo/Name of manfucturer shall be embossed on the pole Galvanization as per relevant as. (a) 4.0 mtr height ,3mm thick bottom dia of 130, & top dia of 70 mm base plate of size 225X225X12mm thick |
| 16 | Providing and laying in position 1:2:4 grade reinforced cement concrete foundation of size 450mm(L)X450mm wide and 1000 mm deepi/c excavation of earth providing cutting bending and placing in position reinforcement of cold twisted bars of 12 mm dia- 960mm long (approx) 8 nos. and reinforcement of cold twisted bars of 12 mm dia- 960 mm long (approx) -8 nos and reinforcement of cold twisted bars of 8 mm dia -1400 mm ( approx) -6 nos.(with 150 mm spacing ) as required with supplying and position of 4 nos. foundation DCW HDPE for cable entry and exit as required for 3 m to 5m pole. |
| 17 | Fabrication, Supplying, Installation, testing, Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside & out sides & suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame, 2 point suspension system with steel wire rope 5mm dia. (7/19 construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminariessymmetrically and its control gears boxes and lighting finial, the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panelhousing suitable RCC (1:2:4) shallowfoundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering the safe soil bearing capacity at site as 10T/sqm at 2mts. depth with all material i/c 4Nos S.P MCB, 63Amp. DP Isolator etc as reqd. Logo/Name of Manufacturer shall be embossed on the pole. Galvanization as per relevant IS. |
| 18 | Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required |
| 19 | Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd. |
| 20 | P/F Name board made of MS Sheet 90X60 Cm, 1 mm thick with frame of MS angle 50X50X6 mm , two diagonal braces at the back of sheet of Ms Flat 40X6 mm total height of the bpard above ground level 2.40 M Length of Leg Below ground 0.30 M embeded in CC Block 1:2:4( 1 cement , 2 Coarse Sand , 4 Graded stone aggregate 40 mm nominal size)30X30X45 cm including excavation and removal of surplus earth with in 50 m lead applying priming coat of approved steel primerpainting with synthetic enamel paint of approved quality and lattering with enamel paint of approved colour ( one side as per drawing/ direction of engineer in charge |