Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr depth and not exceeding 1.5 Mtr in width and getting out completeall as specified and directed. |
| 2 | All as per item No. 1 above but in hard/dense soil/cutting of road/hard standing/breaking of PCC etc. |
| 3 | Returning,filling in and including spreading, leveling, watering and well ramming in layers not exceeding 25 cm to achieve desired compactness complete all as specified and as directed. |
| 4 | Removing surplus soil to a distance exceeding 1.5Km but not exc. 5 KM and depositing where directed at a leveln. exc 1.5 M above the starting point complete all as specified and as directed. |
| 5 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate)in roof kerbs or mud stops, rounded or chamfered on edges etc complete all as specified and directed. |
| 6 | M&L for PCC 1:4:8 Type D2 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 7 | Supply and laying GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor of sizes 15mm bore including taking down old unserviceable complete all as specified and directed. |
| 8 | Supply and laying GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor of sizes 20 mm bore including taking down old unserviceable complete all as specified and directed. |
| 9 | Supply and laying GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor of sizes 25 mm bore including taking down old unserviceable complete all as specified and directed. |
| 10 | Supply and laying GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor of sizes 40 mm bore including taking down old unserviceable complete all as specified and directed. |
| 11 | Supply and laying GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor of sizes 50 mm bore including taking down old unserviceable complete all as specified and directed. |
| 12 | Supply and laying GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor of sizes 80 mm bore including taking down old unserviceable complete all as specified and directed. |
| 13 | Supply and laying GI pipe medium grade ISI marked including all fittings in old position in trenches/wall/ floor as directedof sizes 100 mm boreincluding taking down old unserviceable complete all as specified and directed. |
| 14 | Supplying, Laying, jointing, testing and commissioning in replacement of old unserviceableDI Pipe of 150 mm bore size, with spigot and socketed ends centrifugally castClass K-7 Push on joint confirming to IS 8329laid in trenches complete all as specified and directed. |
| 15 | M&L in replacement of old unserviceable CI/DI fittings for spigot/socket pipes such as bends of any radius and angle, collars, tapers, tail pieces, Tee pieces, Caps and plugs suitable upto 150 mm bore dia all socketed or socket and spigot or side flanged complete all as specified and directed. |
| 16 | M&L for burning out lead joint in any position including removing old lead joint and making new lead joint by using the retrived lead and adding minimum 700 grams new lead for CI pipe of 150mm bore pipes complete all as specified and directed. |
| 17 | S&F Cast iron pipes of bore 100 mm with spigot and socket ends centrifugally cast. Class LA, in any length, laid in trenches/above ground as specified complete all as specified and directed. |
| 18 | Supplying, laying, jointing, testing in replacement of old unserviceable MS pipe,of dia 80 mm Heavy duty class\"C\" confirming to IS - 1239, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, complete all as specified and directed. Note : Welded flanges will be measured and paid seperately. |
| 19 | Supplying, laying jointing, testing in replacement of old unserviceable MS pipe,of dia 100 mm Heavy duty class\"C\" confirming to IS - 1239, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, complete all as specified and directed.Note : Welded flanges will be measured and paid seperately. |
| 20 | Supplying, laying jointing, testing in replacement of old unserviceable MS pipe,of dia 150 mm Heavy duty class\"C\" confirming to IS - 1239, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, complete all as specified and directed. Note : Welded flanges will be measured and paid seperately. |
| 21 | Supply and fixing welded to flanges on ends for MS/GI pipe of dia 80 mm,flange not less than 15mm thick complete all as specified and directed. |
| 22 | Supply and fixing welded to flanges on ends for MS/GI pipe of dia 100 mm,flange not less than 15mm thick complete all as specified and directed. |
| 23 | Supply and fixing welded to flanges on ends for MS/GI pipe of dia 150 mm,flange not less than 15mm thick complete as specified and directed. |
| 24 | M&L Joints with rubber or fibre board gasket of sizes 80 mm complete with nut,bolt and double washers complete as specified and directed. |
| 25 | M&L Joints with rubber or fibre board gasket of sizes 100 mmcomplete with nut,bolt and double washers complete as specified and directed. |
| 26 | M&L Joints with rubber or fibre board gasket of sizes 150 mmcomplete with nut,bolt and double washers complete as specified and directed. |
| 27 | Supply & Fixing in replacement of old unserviceable cast iron Sluice Valveof dia 80 mm ISI marked(PN-1.6) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top with nuts, bolts, washers and gaskets complete all as specified and directed. |
| 28 | Supply & Fixing in replacement of old unserviceable cast iron Sluice Valveof dia 100 mm ISI marked(PN-1.6) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top with nuts, bolts, washers and gaskets complete all as specified and directed. |
| 29 | Supply & Fixing , in replacement of old unserviceable cast iron Sluice Valveof dia 150 mm ISI marked(PN-1.6) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top with nuts, bolts, washers and gaskets complete all as specified and directed. |
| 30 | Supply and fixingin replacement of old unserviceable CI Non return Valve of dia 50 mmwith GM seat, PN-1.0 ISI marked, includingflange joints such as packing, nut and boltsetc complete all as specified and directed. |
| 31 | Supply and fixingin replacement of old unserviceable CI Non return Valve of dia 80 mmwith GM seat, PN-1.0 ISI marked, includingflange joints such as packing, nut and bolts etc complete all as specified and directed. |
| 32 | Supply and fixingin replacement of old unserviceable CI Non return Valve of dia 100 mmwith GM seat, PN-1.0 ISI marked, includingflange joints such as packing, nut and bolts etc complete all as specified and directed. |
| 33 | Supply and fixing in replacement of old unserviceable CI Non return Valve of dia 150 mmwith GM seat, PN-1.0 ISI marked, includingflange joints such as packing, nut and bolts etc complete all as specified and directed. |
| 34 | Supply and fixingin replacement of old unserviceable foot valve flanged type of dia 80 mm with NRV confirming to IS:4038 with flanged ends complete all as specified and directed. |
| 35 | Supply and fixingin replacement of old unserviceable foot valve flanged type of dia 100 mm with NRV confirming to IS:4038 with flanged ends complete all as specified and directed. |
| 36 | Supply and fixingin replacement of old unserviceable foot valve flanged type of dia 150 mm with NRV confirming to IS:4038 with flanged ends complete all as specified and directed. |
| 37 | Labour only for cutting of existing CI / DI pipe of dia 150 mm for insertion of CI/DI specials /valvesetc. all as required including dewatering of leakage water complete all as specified and directed. |
| 38 | S&F in replacementFloat valve with epoxy coated aluminium rod and high density ballofsize 15 mm bore dia incl replacement of existing reducer/nipple of any size complete all as specified and directed. |
| 39 | S&F in replacement Float valve with epoxy coated aluminium rod and high density ballofsize 20 mm bore dia incl replacement of existing reducer/nipple of any size complete all as specified and directed. |
| 40 | S&F in replacement Float valve with epoxy coated aluminium rod and high density ballofsize 25 mm bore dia incl replacement of existing reducer/nipple of any size complete all as specified and directed. |
| 41 | S&F in replacementFloat valve with epoxy coated aluminium rod and high density ballofsize 40 mm bore dia incl replacement of existing reducer/nipple of any size complete all as specified and directed. |
| 42 | S&F in replacementFloat valve with epoxy coated aluminium rod and high density ballofsize 50 mm bore dia incl replacement of existing reducer/nipple of any size complete all as specified and directed. |
| 43 | S&F in replacementgun metal gatevalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of size 15 mm bore incl replacement of existing reducer/nipple of any size complete all as specified and directed. |
| 44 | S&F in replacementgun metal gatevalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of size 20 mm bore dia incl replacement of existing reducer/nipple of any size complete all as specified and directed. |
| 45 | S&F in replacement gun metal gatevalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of size 25 mm bore dia incl replacement of existing reducer/nipple of any size complete all as specified and directed. |
| 46 | S&F in replacement gun metal gatevalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of size 40 mm bore diaincl replacement of existing reducer/nipple of any size complete all as specified and directed. |
| 47 | S&F in replacementgun metal gatevalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of size 50 mm bore dia incl replacement of existing reducer/nipple of any size complete all as specified and directed. |
| 48 | S&F in replacementgun metal gatevalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of size 80 mm bore dia incl replacement of existing reducer/nipple of any size complete all as specified and directed. |
| 49 | S&F in replacement flanged water meter woltman type of dia 150 mmincluding gasket, nut,bolt & double washer as per IS 779, IS 6784, and ISO 4064 complete all as specified and directed. |
| 50 | Supply and fixin replacement Strainer Y type conforming to IS, size 150 mm (6”) dia complete all as specified and directed. |
| 51 | M&L for painting with two coats of synthetic enamelled paint over a coat of red oxide primer on new steel surfaces including preparation of surfacen.exc 10cm width or girth complete all as specified and directed. |
| 52 | M&L for mild steel work MS sheet, angle iron, flat iron etc including cutting, welding, dismantling old unserviceable complete all as specified and directed. |
| 53 | S&F in replacement of old unserviceable rotational moulded polythelene water storage tank (cylindrical vertical with closed top) triple layer of capacity 1000 ltrs hoisted & fixed in position complete all as specified and directed. |
| 54 | All as per item Ser No 53.00 above but 2000 ltrs. |
| 55 | Labour only for bocky system under path/road to pass the GI/CI/DI Pipes upto 150 mm dia manually as directed.. |
| 56 | Supply and fixingin replacement 3 pole power contactor type ML-3, 40 Amps, 415 Volts, 50 HZ complete all as specified and as directed. |
| 57 | Supply and fixingin replacement 3 pole power contactor type ML-4, 80 Amps, 415 Volts, 50 HZ complete all as specified and as directed. |
| 58 | Supply and fixingin replacement 3 pole power contactor type ML-5/6,80-160 Amps,415 Volts, 50 HZ complete all as specified and as directed. |
| 59 | S & F in replacement of Bimetal over load relay typeML 3/4, starter type MNX, relay range 40-80 Amps complete all as specified and as directed. |
| 60 | S & F in replacement of Bimetal over load relay typeML 5/6, starter type MN, relay range 80-160 Amps CT operated complete all as specified and as directed. |
| 61 | Supply and fixing in replacement old unserviceable PVC insulated multistranded copper conductor wire of size 16 Sqmm, single core, 1100 volts complete all as specified and as directed. |
| 62 | All as per item No 61 but size 25 Sqmm |
| 63 | S&F in replacement of3 Pole MCCB,100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA, thermal magnetic release base with Icu= 100% ICSincl rotating handle & taking down the existing MCCB complete all as specified & directed |
| 64 | S&F in replacement of3 Pole MCCB,160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA thermal magnetic release base with Icu= 100% ICSincl rotating handle & taking down the existing MCCBcomplete all as specified & directed |
| 65 | S&F in replacement of3 Pole MCCB,250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA microprocessor base release with Icu= 100% ICSincl rotating handle & taking down the existing MCCBcomplete all as specified & directed |
| 66 | S&F in replacement of 3 Pole MCCB,400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA microprocessor base release with Icu= 100% ICSincl rotating handle & taking down the existing MCCBcomplete all as specified & directed |
| 67 | Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.5meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron strip of 25mmx4mm by means of Copper nuts, bolts and washers.Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 5 of SSR Part-I & testing on completion :-(a)GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel shall be properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. |
| 68 | M&L GI strip 25mmx4mm buried in ground including necessary excavation & earth work in soft/loose soil and removal of excavated material to a distance n.exc 50 mtrs and deposited where directed including taking out old unserviceablecomplette all as specified & directed. |
| 69 | M&L for Lead wool complete all as specified & directed. |
| 70 | M&L in replacement of mild steel Nuts ,Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia complete all as specified & directed. |
| 71 | M& L in replacement of Gland dori as per requirement & directed. |
| 72 | S&F in replacement Digital ammeter of existing size 100mm (Square type) with selector switch & copper thimble and connecting up incl taking down the existing complete all as specified and directed. |
| 73 | S&F in replacementDigital multimeter of existing size 100mm (Square type)with selector switch &copper thimble and connecting up incl taking down the existing complete all as specified and directed. |
| 74 | S&F in replacementElectronic timer type ET-100, 9 to 30 sec, 415V suitable for star-delta/DOL starter upto 30 HP capacity complete all as specified & directed. |
| 75 | S&F in replacement3 phase sequencer complete all as specified & directed. |
| 76 | Supply and laying in replacement of CPVC pipes of outer dia 16 mm SDR 11 & Plain CPVC SDR 11 fittings to trench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 77 | Supply and laying in replacement of CPVC pipes of outer dia 20 mm SDR 11 & Plain CPVC SDR 11 fittings onto trench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 78 | Supply and laying in replacement of CPVC pipes of outer dia 25 mm SDR 11 & Plain CPVC SDR 11 fittingsto trench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 79 | Supply and laying in replacement of CPVC pipes of outer dia 40 mm SDR 11 & Plain CPVC SDR 11 fittingsto trench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 80 | Supply and laying in replacement of CPVC pipes of outer dia 50 mm SDR 11 & Plain CPVC SDR 11 fittings to trench, walls, ceilings or in floors etc incl all fitting & fixtures i.e elbow, Tee, Union, nipple, reducer,FT, MT, socket etc. complete all as specified and directed. |
| 81 | Supply and fixing in replacement of CPVC Ball Valves with brass threaded (two sided) , 15/16 mm (1/2”) dia complete all as specified and directed. |
| 82 | Supply and fixingin replacement of CPVC Ball Valves with brass threaded (two sided) , 20 mm (3/4”) dia complete all as specified and directed. |
| 83 | Supply and fixing in replacement of CPVC Ball Valves with brass threaded (two sided) , 25 mm (1”) dia complete all as specified and directed. |
| 84 | Supply and fixingin replacement of CPVC Ball Valves with brass threaded (two sided) , 40 mm (3/2”) dia complete all as specified and directed. |
| 85 | Supply and fixing in replacement of CPVC Ball Valves with brass threaded (two sided) , 50 mm (2”) dia complete all as specified and directed. |
| 86 | Testing of drinking water being collected from local source (bore wells/sump /shallow wells) ofMetcalfe House Area underGE(I) R&D Delhi and submission of detailed test report to the office of Engr-in-Charge. (a) Collection of water from different sources of water ie. Sump, bore wells & shallow well in a sterilized bottle and testing in GOVT Approved laboratory as mentioned in specification.(b )Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, PH valve TDS total hardness iron, chloride, fluride and residual free chlorine and Bacteriological total coil from organisms per 100 ml (MPN) and E coli in 100 ml) and to this office with specific recommendation regarding suitabiulity of water for drinking purpose.Note:- Rate Quoated shall deemed to be included for :- (i) Cost of sterilized bottle as required.(ii) To and fromtransportation charges for collection of samples from source (sump, bore & shallow wells)to lab and from collection of report form lab. (iii) Testing should be carried out from Govt approved lab. |
| 87 | S&F in replacement ofInline filters (sediment/carbon/mineral etc) of domestic RO of capacity 50/100 ltrcomplete all as specified and directed. |
| 88 | S&F in replacement of Pipe of domestic ROcomplete all as specified and directed. |
| 89 | S&F in replacement of Membrane Houseing of domestic ROcomplete all as specified and directed. |
| 90 | S& F in replacement of Motor 150 GDPIndustrial RO of capacity 25/50 ltrcomplete all as specified and directed. |
| 91 | S&F in replacement of SPUN 10/20\" Industrial RO of capacity 25/50 ltr ltrcomplete all as specified and directed. |
| 92 | S&F in replacement of CTO 10/20\" Industrial RO of capacity 25/50 ltr ltrcomplete all as specified and directed. |
| 93 | S&F in replacement of GAC 10/20\" Industrial RO of capacity 25/50 ltr ltrcomplete all as specified and directed. |
| 94 | S&F in replacement of 10/20\" BowlIndustrial RO of capacity 25/50 ltr ltrcomplete all as specified and directed. |
| 95 | S&F in replacement of SV SLXIndustrial RO of capacity 25/50 ltr ltrcomplete all as specified and directed. |
| 96 | S&F in replacement of Membrane ECO 150 GPDIndustrial RO of capacity 25/50 ltr ltrcomplete all as specified and directed. |
| 97 | S&F in replacement of elbow/TeeIndustrial RO of capacity 25/50 ltr ltrcomplete all as specified and directed. |
| 98 | S&F in replacement of SMPSIndustrial RO of capacity 25/50 ltr ltrcomplete all as specified and directed. |
| 99 | S&Fin replacement of HPS Industrial RO of capacity 25/50 ltr ltrcomplete all as specified and directed. |
| 100 | S&F in replacement of NRV Industrial RO of capacity 25/50 ltr ltrcomplete all as specified and directed. |
| 101 | M&L dewatering, cleaning of 25000 gallons capacity reservoirs with high pressure jet incl lime wash on internal surfaces complete incl Writting the date of cleaning of water tank complete all as directed with the following process:-(i)Dewatering the tank with portable submersible pump set. (ii)Removal of left over dirty water and sludge with special sludge removal pump set .(iii) Cleaning of wall ceiling and floor by high pressure rotary water jet .(iv)Removing of remaining sludge from the floor with the help of industrial vacuum cleaner.(v)Spraying of non toxic biodegraded eco friendly anti bacterial agent certified by a Govt approved lab to disinfect the tank from harmful bacteria.(vi) Weather proof exterior emulsion paint two coats on externalsurfaces after removing/ scraping old painted surfaces complete. |
| 102 | All as per ser item No. 101.00 above but 50,000 gallons capacity. |
| 103 | M&L dewatering, cleaning of Service tank capacity 3000 ltrs (PVC) with high pressure jet incl lime wash internally complete incl Writing of the date of cleaning of the water tankall as directed. |
| 104 | All as per ser item No. 103.00 above butService tank of 2000 Ltrs(PVC). |
| 105 | All as per ser item No. 103.00 above butService tank of 1000 Ltrs (PVC). |
| 106 | Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric Centrifugal/Monoblock/High pressure motor ofcapacities upto 15 HP from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed. |
| 107 | All as per item No 106 above but of capacity more than 15-30 HP |
| 108 | All as per item No 106.00 above but of capacity50 HP to 75 HP |
| 109 | Opening the electric Centrifugal/Monoblock/High pressure/openwell motor ofcapacity upto 15 HP including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weight etc. including all other insulating material & relacement of bearings,repair of shaft to make it functionalcomplete all as specified and as directed . |
| 110 | All as per item No 109 above but of capacity more than 15-30 HP |
| 111 | All as per item No 109.00 above but of capacity 50 HP to 75 HP |
| 112 | Disconnecting and De-coupling the Centrifugal/Monoblock/High pressure/openwell pump ofcapacity upto 15 HP from foundation after opening /cutting the rustednuts, bolts etc including transporting the pump to workshop for repairand back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etcincluding testing complete all as specified and as directed. |
| 113 | All as per item No 112 above but of capacity more than 15-30 HP |
| 114 | All as per item No 112.00 above but of capacity 50 HP to 75 HP |
| 115 | Opening the Centrifugal/Monoblock/High pressure pump ofcapacity, upto 15 HP repairing the same by replacing the unserviceable spare parts (i.e impeller,shaft,bearings,seal etc) including machining work and re-assembling the same in original position complete all as specified and as directed.Note:-All Spare Parts required to make pump fully functional is deemed to be included in above quoted rates. |
| 116 | All as per item No 115 above but of capacity more than 15-30 HP |
| 117 | All as per item No 115.00 above but of capacity 50 HP to 75 HP |
| 118 | Disconnecting water pipe line , electric connection and taking out submersible pump set of any capacity alongwith column pipe and submersible cable and re-lowering the same after developing the bore well including replacement of rubber gasket , nuts,bolts and washer where ever required complete all as specified and directed. |
| 119 | Opening the submersible pump set of capacity upto 10 HP including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weightetc. including all other insulating material & relacement of bearings,repair of shaftetc. ,incl repair to the pump by replacing the unserviceable spare parts (i.e impeller,shaft,bearings,seal etc) including machining work and re-assembling the pump set in original position with required insulating material to make it functionalcomplete all as specified and directed . . |
| 120 | M&L for spray painting of all metal surfaces of Pump House (Desidoc/Lastec) comprising 2 Nos of main fire pump of cpacity 75 HP, 1 No of jockey pump of capacity 15 HP, 2 Nos of main water supply pump of capacity 30 HP including their respective LT panels, pipe lines & header in Pump house with two coats of synthetic enamel heat resistant paint maching to existingcolour over a coat of red oxide primer by spray gun machine including preparation of old painted surfaces/removing old faded/rust/ cemented material of surface of complete all as specified and directed. |
| 121 | All as per item No 120.00 above but 2 Nos of main fire pump (JCB) of capacity 75 & 50 HP, 1 No of jockey pump of capacity 15 HP |
| 122 | All as per item No 120.00 above but 1 Nos of main fire pump (SAG) of capacity 75 HP & 1 Nos of diesel engine fire pump of capacity 79 HP, 1 No of jockey pump of capacity 15 HP |
| 123 | All as per item No 120.00 above but 2 Nos of water supply pump (North Gate) of capacity 30 HP. |
| 124 | All as per item No 120.00 above but 2 Nos of water supply pump (DCDA) of capacity 15 HP. |
| 125 | S&F in replacement dial type 2400 hours timer, 16 Amps, SP, after taking down/out starter as existing at site complete all as specified and directed . |
| 126 | S&F in replacementmembrane of size 40mmx40mmcomplete all as specified and directed. |
| 127 | S&F in replacement30\"X 4.5 \"dia forwound cartriage water treatment plant complete all as specified and as directed. |
| 128 | S&F in replacement chemical Dozing pump for RO plant complete all as specified and directed. |
| 129 | M&L for B check general servicing by authorised rep of manufacturer of DG set of capacity 250 KVA, replacement of oil filter, fuel filter, air filter, by pass filter cleaning of radiator with chemical afterdraining out engine/ lubrication oil, coolant flushing and cleaning of oil chamberafter opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment reaffixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof sollution, oil pan/ chamber gasketat the servicing and other work comes under B Check service as mentioned in B Check by the manufacturer all as speciied and as directed.Note-Engine oil & Coolant will be included under respective item. |
| 130 | M&L for repair of self starter 24 V including rewinding of armature with super enamaled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set upto 250 KVA complete all as specified and as directed. |
| 131 | Supply & Fixing in replacement of automatic battery charger with auto cut OFF suitable for charging of 2X12V 180AH batteries complete with all required necessary wiringcomplete all as specified and directed. |
| 132 | M&L for replacement of wiring complete to AMF panel for any capacity of DG set includinginterlock system of AMF panel with existing size of copper wiring including proper connection and testing complete all as specified and directed. |
| 133 | Supply and Fix in replacement of battery brass terminals heavy duty suitable for 12V 180 AH battery with minimum 2 RM Battery Lead of copper Cable single core all as directed by engr-in-charge. |
| 134 | Supply and Fixin replacement ofrelay 24 V 8 pin type as per matching to existing and properly connection and testing after completion complete all as specified and directed. |
| 135 | S & F and testing Electronic Governor Controller for 250 KVA DG Set including taking down old Governor Controller complete all as specified and directed. |
| 136 | Taking down the old U/S fan belt and Supply andFix Fan belt of existing size for DG Set of capacity 250 KVA complete all as specified and directed. |
| 137 | Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifoldforfor DG sets 250 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed. |
| 138 | Supply and fixingin replacement 3 pole power contactor MNX400, 400 Amps, 415 Volts, 50 HZ complete all as specified and as directed. |
| 139 | S&F in replacement fly wheel ring of DG Set of capacity 250 KVA as per existing make & model complete all as specified and directed. |
| 140 | M&L for draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 250KVA complete all as specified and directed. |
| 141 | M&L for repair toradiator of 250 KVA DG set,arresting leakage if any by welding/brazing and refixing the same for(Necessary coolant and distrilled water required will be measured and paid seperately) complete all as specified and directed. |
| 142 | Removing old U/Sinsulating material asbestos rope and fixing of newof existing size and shape complete all as directed |
| 143 | M&L for repair to alternator of DG Set of capacity 250 KVA complete including rewinding & replacement of connected items such as bearing, sleeves Nut bolts, coupling etc complete all as specified and as directed |
| 144 | Removing and replacing the old unserviceable lead acid battery of size 12 Volt, 180 AH of reputed make including charging all as specified as directed. |
| 145 | S&F ACP retro sign board of size 1.8 x 0.4 Meter using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the Pump House details and MES Logo. Retro sign board shall be pasted on 3 mm thick ACP sheet. The board shall be fixed on Wall including fixing of fastners, nuts, bolts, washer etc complete all as directed by Engineer-in-Charge at site. |
| 146 | S&F ACP retro sign board of size 1.8 x1.2 Meter using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the Single line Schematic diagram of Pump House. Retro sign board shall be pasted on existing board complete all as directed by Engineer-in-Charge at site. |
| 147 | Supply and fixing in replacement DOL starter upto 5 HP complete all as specified & directed |
| 148 | Supply only sodium hypochloride (liquid bleach) 10 % (20 ltr each pack) complete all as specified and directed. |
| 149 | M&L for LED energy saving and environmental friendly long life versatile pressure die cast aluminium IP 66 roadway luminaire with high power LEDs and electronic diver complete set of 60 wattage 6000K, with PF-=>0.95, THD-<=10%, driver should be same make as of LED fitting, with operating range of 140 V to 280 V, isolation of driver facility as directed complete all as specified and directed by Engineer-in Charge. |
| 150 | M & Lfor replacement of cable PVC insulated unarmored for connection 1.5 sqmm x 3 core Copper conductor duly drawn fromjunction box to street light fittings on poles including PVC flexible pipes complete all as specified and directedby Engineer-In - Charge. |
| 151 | M&L in Replacement of GI bracket made of 40 mm medium grade GI pipe bend to shape approx 1.8 mtr length incl Clamp etc complete for fixing of street light complete all as specified and directed. |
| 152 | Attending of complaints of external water supply installation as and when required / called up by this office for non functional of borewell submersible pumps or any water supply mains / distribution lines / control valves to make the water supply installation functional round the clock. minor repair will be carriedout on spot and other major item will be measured & paid seperately complete all as specified and directed.Note :- (i) T&P items, complaint register, comlaint slip book and any other minor items required for making water supply installation functional will deemed to be including in the quoted rates. |
| 153 | Supply only in replacement of GI socket 100mm / 80mm size ISI marked complete all as specified and directed. |
| 154 | Supply only in replacement of GI socket 50mm / 40mm size ISI marked complete all as specified and directed. |
| 155 | Supply only in replacement of GI socket 25mm / 20mm / 15mm size ISI marked complete all as specified and directed. |
| 156 | Supply only in replacement of GI elobow 100mm / 80mm size ISI marked complete all as specified and directed. |
| 157 | Supply only in replacement of GI elobow 50mm / 40mm size ISI marked complete all as specified and directed. |
| 158 | Supply only in replacement of GI elobow 25mm / 20mm /15mm size ISI marked complete all as specified and directed. |
| 159 | Supply only in replacement of GI union 100mm / 80mm size ISI marked complete all as specified and directed. |
| 160 | Supply only in replacement of GI union 50mm / 40mm size ISI marked complete all as specified and directed. |
| 161 | Supply only in replacement of GI union 25mm / 20mm / 15mm size ISI marked complete all as specified and directed. |
| 162 | Supply only in replacement of GI equal tee 100mm / 80mm size ISI marked complete all as specified and directed. |
| 163 | Supply only in replacement of GI equal tee 50mm / 40mm size ISI marked complete all as specified and directed. |
| 164 | Supply only in replacement of GI equal tee 25mm / 20mm /15mmsize ISI marked complete all as specified and directed. |
| 165 | Supply only in replacement of GI reducer tee 50x20mm / 40x20mm size ISI marked complete all as specified and directed. |
| 166 | Supply only in replacement of GI reducer tee 25x20mm / 20x15mm size ISI marked complete all as specified and directed. |
| 167 | Supply only in replacement of GI nipple of size 50mm / 40mm into 4 inch / 6 inch long ISI marked complete all as specified and directed. |
| 168 | Supply only in replacement of GI nipple of size 25mm / 20mm /15mm into 4 inch or 6 inch long ISI marked complete all as specified and directed. |
| 169 | Supply only in replacement of GI reducer of size 50/40mm or 50/25mm ISI marked complete all as specified and directed. |
| 170 | Supply only in replacement of GI reducer of size 40/25mm or 40/20mm ISI marked complete all as specified and directed. |
| 171 | Supply only in replacement of GI reducer of size 25/20mm or 25/15mm or 20/15mm ISI marked complete all as specified and directed.Note : Labour Charges for fixing of item no. 153 to 171 are included in the quoted rate of item no. 152. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail