| 1 | Demolition of brick work orstone/ boulder masonry, built in cementmortar including all quoins, pillars etc complete all as specified and as directed. |
| 2 | Demolition of PCC in ground floors and pavings not exc 15 cm thickness below or above ground level, complete all as specified and as directed. |
| 3 | M&L for PCC1:4:8 type D-2 (using 40 mm gradedstone aggregate) nominal mix as in foundation filling,mass concrete etc complete all as specified. |
| 4 | M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate nominal mix in benching of surface channel as in drains and finishing complete all as specified and directed by Engineer-in-Charge. |
| 5 | M&L extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc (inner girth only measured) complete all as specified and directed. |
| 6 | M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) nominal mix as in coping,kersbs, mud stops rounded or chamfered in edges etc, finish even & fair without using extra cement,complete all as specified and directed including necessary formwork as per site requirement |
| 7 | M&L PCC 1:2:4 type B-1 (using 12.5 mm graded stone aggregate) nominal mix as in posts,Holdfastscomplete all as specified and directed including necessary formwork as per site requirement |
| 8 | M&L for PCC1:3:6 type C-2 (using 40 mm gradedstone aggregate) nominal mix as in drain beds etc complete all as specified. |
| 9 | M&L for PCC1:3:6 type C-1 (using 20 mm gradedstone aggregate) nominal mix as in plinth protection complete all as specified. |
| 10 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m meanradius builtin cement mortar 1:4 etc,complete complete all as specified and as directed. |
| 11 | All as item No.11 but Except brick workbuilt in CM (1:4) completeall as specified and directed. |
| 12 | M&L for Rendering 15 mm thick on new preparedbrick work or concrete surface on wallin cement mortar 1:4 finished even and smooth without using extra cement completeall as specified. |
| 13 | M&L Preparation of new plaster on brick wall surfaces and applying two coat of cement base paintover a coat of primer of same make on walls complete all as specified and directed |
| 14 | M&L for road cutting as in channels,grooves,trimming surface exc 15 cm and n exc 30 cm in girth complete all as spd and directed |
| 15 | Demolition and Breaking of drain pipes (RCC/SGSW/AC) pipe of Int dia 200 mm complete all as spd and directed |
| 16 | M&L for Providing RCC Pipe of 200 mm bore dia class NP2 laid and jointed complete with collars complete all as spd and directed. |
| 17 | Taking down cement / lime plaster on brick or concrete surfaces etc including racking out joint, hacking for key screbbing down with water etc.complete all as specified. |
| 18 | M&L for rendering 10mm thick cement plaster in CM 1:4 on fair faces of brick work or concrete surface finished fair & even without using extra cement complete al as specified and as directed. |
| 19 | M & L for preparation of newly plastered surface of wall and and threecoats of white washcomplete all as specified and directed. |
| 20 | M&L forHeavy Duty Vitrified parking tiles of size 300x300x15mm thick fixed over and including 15mm thick screed bed in cement mortar 1:4 fixed using spacers of 5-6mm and joints filled with epoxy over and including 75mm thick cement concrete 1:4:8 type D-2 using 40mm graded aggregate including demolition of existing path/hardstanding of any type/pattern complete all as specified and directed. |
| 21 | M&L for demolition of existing concrete/stone jallies of any type including post/pillars complete all as specified and directed. |
| 22 | M&L for stone slab 20-35mm thickdesigner jafri any shade for fixing in designer post jointing and pointing with neat cement slurry with pigment and silicon/araldite incl demolition of existing concrete/stone jallies of any type complete all as specified and directed. Note:- Colour of stone and design as approved by GE shall be provided. |
| 23 | M&L forstone Post/pillar designer cross section 100mm x100mm and600 to 900mm high with grove for jafri wall complete all as specified and directed. |
| 24 | M&L for 25 to 30mm thick Dholpur stone laid over cill /cladding to wall, gang saw cut, machine cut edges, uniform colour face work, table rounded , straight edge, laid and jointed in neat cement and stone dust mortar 1:3,pointed with and admixture of white cement and over and including 15mm thick plaster in Cement mortar 1:6, of each stone size exceeding 0.5 sqm area fixed with and including silicon treatment incl dismantling of existing stone slabs of any description and any type complete all as specified and directed |
| 25 | Demolition of RCC work of any description and in any position etc all as specified. |
| 26 | M&Lfor Nominal mix RCC 1:1.5:3 type A-1(using 20 mm graded stone aggregate) as inSlabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 27 | M&L for precast cover slabs Factory madetype B-1 1:2:4(using 20mm mm graded stone aggregate)like for manhole/ drains etc inclluding TMT Bars as per manufacturer instructioncomplete all as specified and directed by Engineer-in-Charge. |
| 28 | M&L for Formwork to faces of wall,parapet, coping,lintel,landing, to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter not specified complete all as specified and directed. |
| 29 | M&L TMT bars 6 mm to 8 mm dia cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 30 | M&L TMT bars10 mm and abovedia cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 31 | Dismantling posts or struts (wood, steel or R.C.C.) any section, embedded in Concrete, brick work, masonry, etc. including taking out embedded portion and making good disturbed ground, complete all as specified and directed. |
| 32 | Dismantling barbed wire any type and any size complete all as spd and directed |
| 33 | S&F,mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, running bars, for chain link fencing including embeding in concrete and similar work conforming to Fe-290 Gde E-165complete all as specified and directed |
| 34 | Supply only MS screw, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exceeding 5cm and not exceeding 10cm long and dia of bolt etc, complete all as specified and directed |
| 35 | Supply and fixing of galvanised chain link fencing any size and any type fixed to any standard rail/steel post with suitable size of MS bolt and nuts and fixing plate etc, complete all as specified and directedNote : MS bolts/Nuts will be measured and pait seperately |
| 36 | Dismantling wrought iron or mildsteel work of any description not otherwise provideed for complete all as specified and directed. |
| 37 | S&Fframed work as in door or gates of angle or other section Fe-410 W (Gde E-250) with gusset plates , rails braces etc complete drilled for fixing of steel sheeting or other covering complete all as spd and directed. |
| 38 | M&L for 0.5-1.0 mm thick plain PVC Sheet fixed in doors,Gate with coach screw and PVC washers (length and girth as fixed)etc complete all as specified. |
| 39 | M&L, two coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel/iron surfaces exceeding 10cm width or girth.complete all as specified and directed |
| 40 | M&L, one coats of synthetic enamelled paint including preparation of oldsteel/iron surfaces exceeding 10cm width or girth.complete all as specified and directed |
| 41 | M&L, two coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel/iron surfaces not exceeding 10cm width or girth.complete all as specified and directed |
| 42 | M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified. |
| 43 | M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigmentlaid in floor and joints of interlocking tiles/ paver block broomed and filled properly etc complete all as specified and directed. NOTE:- Site clearance of materials- All demolished material obtained from dismantling/demolition items shall be deposited at place shown by Engr-in-charge properly spread and levelled and site to be cleaned to the entire satisfaction of Engr-in-charge. |