| 1 | WATER COOLER STORAGE TYPE Taking out existing unserviceable Water Cooler Storage type of any capacityof any makeand refixing the same to its position after removal of all other unserviceable parts/spares such as starting capacitor, Running capacitor, relay, Thermostat, fan motor, float valve, push cock etc and replaced with New parts as required complete all as specified and directed.Note :- The replacement of unserviceable parts shall be measured & paid for separatelyunder relevant items. |
| 2 | Taking out existing compressor unit from the water cooler of capacity 40/80/120/150 Ltr of any make including removed of all other unserviceableparts/spares such as strainers, filter, capillary tubes suction /discharge pipe, thermostat switch, float valve, push cock running , startingcapacitor, over load relay complete all as specified and directed |
| 3 | Supply and Fixing company repaired compressor in lieu of defective compressor to water cooler of 150 Ltr/Hr cooling capacity including painting, jointing capillary tube and testing the compressor complete all as specified and directed. |
| 4 | All as per Srl No. 3 here-in-before but of cooling capacity 60 Ltr/Hr. |
| 5 | All as per srl No. 3 here-in-before but of cooling capacity 40 Ltr/Hr. |
| 6 | Supply and fixing new compressor to water cooler of 150 Ltr/Hr cooling capacity including,jointing capillary tube and testing the compressor complete all as specified and directed.Makes : Tecumseh /Copeland/Bluestar/Godrej/GMCC. |
| 7 | Supply and fixing new compressor to water cooler of60 Ltr/Hr cooling capacity including,jointing capillary tube and testing the compressor complete all as specified and directed.Makes : Tecumseh /Copeland/Bluestar/Godrej/GMCC |
| 8 | Supply and fixing new compressor to water cooler of 40 Ltr/Hr cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed.Makes : Tecumseh /Copeland/Bluestar/Godrej/GMCC |
| 9 | M&L for servicing of water cooler any size and make including drain outwater cleaning of water tank and cleaning of condersor coil withanti scaling solution complete all as specified and directed. |
| 10 | M&L charging of water cooler with R-134a,R-22,R-290,R-410 gas complete includingleakage test and testingof water cooler on full load for 24 hrs continuously at site of any Make of any capacity complete all as directed |
| 11 | M&L repairing the water cooler / body by replacing rusted MS sheet body with new MS sheet of 16 SWG approx area 2.5 Sq ft complete including replacement of unserviceable channel legs, fan motar base complete all as specified and directed. |
| 12 | Taking out existing unserviceable fan motor of capacity 1/8 HP from water cooler, dismantling the motor and taking out old burnt copper winding wire, rewinding of fan motor with similar size super enamelled copper winding wire of Make of HTP/devidayal after providing \"E\" class insulation material complete including replacement of unsv pad MS clamps, nut and bolt, varnishing & refixing the motor in the watercooler and testing of water cooler complete all as specified and directed. |
| 13 | Supply, fixing and connecting in replacement new fan motor of water cooler capacity 1/8 HP 230 Volt 50 c/s of make MIE/Khaitan/ Crompton Greaves complete all as specified and directed. |
| 14 | M&L replacement of fan blades of fan motor of water cooler of make sidwal of capacity 150 ltr made out of GI Sheet complete all as per existing shape and size. |
| 15 | Supply,fixing and connecting the Running capacitor 36 MFD of water cooler of capacity 120/150 Ltr complete all as specified as directed.Makes – USHA/UNISTAR/TIBCON/Havells/Hightech or equivalent in approved makes. |
| 16 | All as per Srl item No 15 here-in-before but Starting capacitor 80-100 MFD. |
| 17 | All as per Srl item No 15 here-in-beforebutOver load protector as per sample. |
| 18 | All as per Srl item No 15 here-in-before but Starting relay 1/8 HP as per sample. |
| 19 | All as per Srl item No 15 here-in-before but Thermostat switch for water cooler as per sample. |
| 20 | All as per Srl item No 15 here-in-before Push cock brass HD chromium plated. |
| 21 | All as per Srl item No 15 here-in-before but float valve ½” dia, brass with ball. |
| 22 | All as per Srl item No 15 here-in-before but Rubber hose pipe/ for 1 ½” dia and 1.5 m longdrain pipe. |
| 23 | REFRIGIRATOR 310 LTRTaking out existing unserviceable Refrigerator/Deep Frezzer of any capacity and any makeand refixing the same to its position after removal of all other unserviceable parts/spares such as Overload protector,starting capacitor, overload Running capacitor, relay etc and replaced with New parts as required complete all as specified and directed by Engineer-in-Charge.Note :- The replacement of unserviceable parts shall be measured & paid for separatelyunder relevant items. |
| 24 | Taking outexisting compressor unit from the refrigerator of any capacity, of any make including removed of all otherunserviceableparts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder,capillary tubes, freezer door complete all asspecified and directed. |
| 25 | Taking outexisting compressor unit from the deep freezerof any capacity of any make including removed of all otherunserviceableparts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder,capillary tubes, freezer door complete all asspecified and directed. |
| 26 | Supply & fixing only company repaired compressor in lieu of defective compressor to refrigerator of 195/165 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected. |
| 27 | Supply & fixing only company repaired compressor in lieu of defective compressor to refrigerator of 310/280 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected. |
| 28 | Supply & fixing company repaired compressor in lieu of defective compressor to deep freezer of 200/250 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected. |
| 29 | Supply & fixing company repaired compressor in lieu of defective compressor to deep freezer of 300/400 ltr capacity including jointing capillary and testing the compressor complete all as specified anddirected. |
| 30 | Supply and fixing new compressor to refrigerator ofcapacity 310 ltrincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Makes :Tecumseh /videocon//Godrej/Whirlpool/LG. |
| 31 | Supply and fixing new compressor to refrigerator ofcapacity 195/165 ltrincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Makes :Tecumseh /videocon//Godrej/Whirlpool/LG. |
| 32 | Supply and fixing new compressor to Deep freezer of capacity 320 ltrincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /Hittchi/Bluestar/Godrej/LG/Copland. |
| 33 | Supply and fixing new compressor to Deep freezer of capacity 250 ltrincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /Hittchi/Bluestar/Godrej/LG/Copland. |
| 34 | Charging of gas in Refrigerator/Deep Freezerwith R-134a,,R-290,R-410 & R-600 gas complete includingleakage test and testingof water cooler on full load for 24 hrs continuously at site of any Make of any capacity complete all as specified and directed. |
| 35 | Supply,fixing and connecting Plunger type relay 1/6 HP of REFRIGERATOR complete all as specified and directed. |
| 36 | All as per Srl item No 35 here-in-before butOver load protector 1/6 HP. |
| 37 | All as per Srl item No 35 here-in-before butThermostat switch with knob - u-50-1018. |
| 38 | All as per Srl item No 35 here-in-before butGlass cover heavy duty of Refrigeratorcapacity 310 ltrs. |
| 39 | All as per Srl item No 35 here-in-before butRepair to Freezer door forRefrigerator of Cap 310 ltr. |
| 40 | All as per Srl item No 35 here-in-before butTimer controller for Double doorRefrigerator of Cap 310 ltr. |
| 41 | All as per Srl item No 35 here-in-before butHeating Elemnet for Double doorRefrigerator of Cap 310 ltr. |
| 42 | All as per Srl item No 35 here-in-before butBioMetal for Double doorRefrigerator of Cap 310 ltr. |
| 43 | All as per Srl item No 35 here-in-before butSupply Sensor for Double doorRefrigerator of Cap 310 ltr. |
| 44 | Supply & fixingPCB unit of Double Door Refrigertor 310/400 Ltrs of existing make complete all as specified and directed. |
| 45 | Supply & fixingButter box / any try any type and size as per sample complete suitable for whirlpool/Samsungrefrigarater of Cap 310 Ltr |
| 46 | Supply,fixing and connecting the Running capacitor 06-15 MFD of Refrigerator/ Deep Freezer of capacity 120/150 Ltr complete all as specified as directed.Makes – USHA/UNISTAR/TIBCON/Havells/Hightech or equivalent in approved makes. |
| 47 | Supply,fixing and connecting, Replacement ofthe existing damage, choked Backside Condensor Coil from the Refrigerator of Cap 165/195Ltr of any make complete all as specified and directed. |
| 48 | Supply,fixing and connecting, Replacement ofthe existing damage, choked evaporator (Freezer) from the Refrigerator of Cap 310 Ltr of any make complete all as specified and directed. |
| 49 | All as per Srl item No 48 here-in-before but Replacement ofthe existing damage choked evaporator (Freezer)from the Refrigerator of Cap 165 Ltr of any make complete all as specified and directed. |
| 50 | Supply,fixing and connecting the Running capacitor 20-36 MFD of Refrigerator/ Deep Freezer of capacity 120/150 Ltr complete all as specified as directed.Makes – USHA/UNISTAR/TIBCON/Havells/Hightech or equivalent in approved makes. |
| 51 | Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing \"E\" class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the DF Ref and testing of appliaces complete all as specified and directed. |
| 52 | Taking out existing serviceable fan motor and Compressor from the unsv body of Deep freezer of capacity 320 liters carefully. Supply of deep freezer body made out as per OEM manufacturer duly painted complete including relay inside condensor coil proper insualated with sheet, thermostat and refixing the fan motor and compressor and testing complete all as specified and directed |
| 53 | Taking out exiting unserviceable fan motor with blade of capacity 1/8 HP from the cooler/Deep freezer/ Refrigerator dismantling the motor and connecting new fan motor & Fan Blade complete all as specified and directed. |
| 54 | AIR CONDITIONER WINDOW TYPE 1.5 TON CAPTaking out existing unserviceable Split /window typeAir conditioner of capacity 1.5 Ton of any make and capacity and refixing the same to its position after removal of all other unserviceable parts/spares such as strainer, pillar suction, starting capacitor overload Running capacitor relay etc and replaced with New parts as required complete all as specified and directed by Engineer-in-Charge.Note :- The replacement of unserviceable parts shall be measured & paid for separatelyunder relevant items. |
| 55 | Taking out existing serviceable window typeAir conditioner of capacity 1.5 Ton of any make and capacity and refixing the same to its position after serviceing with anti scaling solution and cleaning complete including removal of all other unserviceable parts/spares such as strainer, pillar suction, starting capacitor overload Running capacitor relay etc and replaced with New parts as required complete all as specified and directed. |
| 56 | All as per Srl item No 55 here-in-before but split type AC of Cap 1.5 Ton. |
| 57 | Supply and fixing company repaired compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor,capillary,, copper tubing as required and testing the compressor complete all as specified and as directed. |
| 58 | Supply and fixing New compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor,capillary,copper tubing as required and testing the compressor complete all as specified and as directed.Makes: Tecumseh /Bluestar/Godrej/Hittchi/Whirlpool |
| 59 | Supply and fixing New compressor in lieu of defective compressor to Air Conditioner of 2.0 Ton capacity including jointing compressor,capillary, copper tubing as required and testing the compressor complete all as specified and as directed.Makes : Tecumseh /Bluestar/Godrej/Hittchi/Whirlpool |
| 60 | Supply and fix in replacement of copper tubing for split type Air conditioner of 1/4 \", 1/2\" or any size required at site Including Insulation Pipe complete all as specified and directed. |
| 61 | Charging of gas in Split/Window ACwith R-134a,,R-22,R-32 & R-410 gas complete includingleakage test and testingof water cooler on full load for 24 hrs continuously at site of any make of any capacity complete all as directed |
| 62 | Dismantling taking out existing unserviceable fan motor of capacity 1/8 HP from window type Air conditioner/Split type dismantling the motor and taking out old burnt copper winding wire and rewinding of fan motor with similarsize super enamelled copper winding wire of make. HTP/Devidayal after providing\"E\" class insulation material complete includingreplacement of unsv rubber pad MS clamp nut bolt varnishing and refixing themotor in the A/C and testing of Air conditioner complete all as specified and directed. |
| 63 | Supply & fixing outer unit of spilt type AC 1.5 Tonn of existing make complete with condenser coil and compressor etc all as specified and directed. |
| 64 | Supply & fixing inner unit of spilt type AC 1.5 Tonn of existing make complete all as specified and directed. |
| 65 | Supply & fixing PCB unit of spilt type AC of existing make complete all as specified and directed. |
| 66 | M&L for repair of existing UNSV PCB unit of spilt type AC of existing make complete all as specified and directed. |
| 67 | M&L for repair of existing UNSV PCB unit of Invertor Type spiltAC of existing make complete all as specified and directed |
| 68 | Supply & fixing in replacement of condenser/Evaporator coil of window type AC of 1.5 TR Capacity any make complete all as specified and directed. |
| 69 | Supply & fixing in replacement of condenser/Evaporator coil of split type AC of 1.5 TR Capacity any make complete all as specified and directed. |
| 70 | Supply, fixing and connecting Running capacitor 36-50 MFD complete all as specified and directed. |
| 71 | Supply, fixing and connecting Running capacitor 04-06 MFD complete all as specified and directed. |
| 72 | All as per Srl item No 71 here-in-before but Over Load protector No SR-1622 complete all as specified and directed |
| 73 | All as per Srl item No 71 here-in-before but Swing Motor for indoor unit as per existing type and size |
| 74 | All as per Srl item No 71 here-in-before but Starting Relay box type 1/8 HP SR-1622complete all as specified and directed. |
| 75 | All as per Srl item 71 here-in-before but drain pipe for indoor unit of splt AC and 1.5 m longdrain pipe. |
| 76 | Taking out existing unserviceable fan motor from the Air conditioner supply fixing and connecting new fan motor 1/8 HP 230 Volt 50 C/s single phase complete including MS clamps and rubber pad , Fan Blade complete all as specified and directed. |
| 77 | Taking out existing serviceable Split type Air conditioner indoor unit of capacity 1.5/2.0 Ton of any make and capacity and refixing the same after stoppage of leakage from indoor unit and replacemenet ofunserviceable parts/spares such as strainer, pillar suction, starting capacitor, Running capacitor relay etc and replaced with New parts as required complete all as specified and directed by Engineer-in-Charge.Note :- The replacement of unserviceable parts shall be measured & paid for separatelyunder relevant items. |
| 78 | M&L for shifting of airconditioner split type of any make from its original position to another position with andincluding wall stand and any B & R work reqd and electric work requiredfor it complete all as specified and directed. |
| 79 | M&L for shifting of air conditioner window type of anymake from its original position to another position with andincluding any B& R work and electric work requiredfor it complete all as specified and directed. |
| 80 | DESERT COOLER Taking out exiting unserviceable fan motor of capacity 1/8 HP from the desert cooler/ dismantling the motor and taking out old burnt Aluminium winding and rewinding of blower motor with similar size of super enamelled Alumium winding wire of make: HTP/ Devidayal after providing \"E\" class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the Desert Cooler and testing of Desert Cooler complete all as specified and directed. |
| 81 | Taking out existing unserviceable Tulu pump (water pump) from the desert cooler supply and fixing connecting new Tulu pump 1/20 HP 230 Volt 50 C/S single phase of ISI Marked all as specified and directed. |
| 82 | Taking out existing unserviceable fan motor from the desert cooler supply fixing and connecting new fan motor 1/8 HP 230 Volt 50 C/s single phase complete including MS clamps and rubber padcomplete all as specified and directed. |
| 83 | M&L Replacement of Desert Cooler front show grill made of PGI sheet 20 gauge duly painted all as specified and directed. |
| 84 | M&L Replacement of Desert Cooler sides Shutters made of PGI sheet 20 gauge with pad sporting frame of size duly painted all as specified and directed. Note: A set shall be of 3 shuters and the quoted rate shall deemed per set. |
| 85 | M&L Replacement of capacitor 4 MFD, 230 volts 50 c/s of complete all as specified and directed. |
| 86 | M&L Replacement of 3 wayPVC distributer complete all as specified and directed. |
| 87 | M&L Replacement of selector switch with knob complete all as specified and directed. |
| 88 | M&L Replacement of switch for tullu pump of desert cooler as per existing make and type complete all as specified and directed. |
| 89 | M&L Replacement of 5 amp top plug for Desert cooleras per existing make and type complete all as specified and directed. |
| 90 | Taking out unserviceable fan blades of fan motor from the desert cooler and supply and fixing new blade of standard quality and as per existing size complete all as specified and directed. |
| 91 | Taking out existing serviceable fan motor and Tulu pump from the unsv body of desert cooler carefully supply of desert cooler body made out of GI sheet 18 gauge duly painted complete including shutters front show grill made out of GI sheet, wooden wool pad and refixing the fan motor and Tulu pump and testing complete all as specified and directed. |
| 92 | M&L Painting of desert cooler body at site of any make and capacity with one coat of approved quality synthetic enamelled paint over a coat of red oxide primer after cleaning of dust rust and preparation of surface both inside and out side complete all as specified and directed. |
| 93 | Supply and fixing PVC pipe 15mm diain each cooler complete all as specified and directed. |
| 94 | Taking out unserviceable supporting leg fan motor with screw and fixing new supporting legs as per existing size complete all as specified and directed |
| 95 | M&L Replacement of wood wool pad, supporting wire frame (set of three) and fixing in Desert cooler all as specified and directed. |
| 96 | REPAIR TO VOLTAGE STABILIZER OF CAPACITY5 KVA MAKE - INTEG/NAYAR/ BLUE LINE COMPRISING THE FOLOWING:Dismantling and opening of main transformer and taking out of old burnt Aluminium winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning \"E\" class insulator material varnishing and refixing complete all as specified and directed. |
| 97 | Dismantling of printed circuit board complex with condenser choke pre fixer and time delay relay and supply & fixing of new printed circuit board complete all as specified and directed. |
| 98 | Supply and fixing volt meter Display 0-300 volt single phase 230 volt for 5 KVA make Bajaj/Crompton/GEC complete all as specified and directed. |
| 99 | Supply and fixing Bakelite connector in main connection lead complete all as specified and directed. |
| 100 | REPAIR TO VOLTAGE STABILIZER OF CAPACITY 4 KVA OF MAKE - INTEG/ NAYAR/ ELECTRON COMPRISING OF FOLLOWING Dismantling and opening of main transformer and taking out of old burnt Aluminium winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning\"E\" class insulator material varnishing and refixing complete all as specified. |
| 101 | Dismantling of printed circuit board complete with condenser dioel pre fixer of time delay relay. and supply & fixing of new printed circuit board complete all as specified and directed. |
| 102 | Supply and fixing Bakelite connector in main connection lead complete all as specified and directed. |
| 103 | Supply and fixing volt meter Display 0-300 volt single phase 230 volt for 4KVA make Bajaj/Crompton/GEC complete all as specified and directed. |
| 104 | REPAIR TO VOLTAGE STABILIZER OF CAPACITY 3 KVA MAKE- ELECTRON COMPRISING THE FOLLOWING :- Dismantling and opening of main transformer and taking out of old burnt Aluminium winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning \"E\" class insulator material varnishing and refixing complete all as specified and directed. |
| 105 | Supply and fixing volt meter Display 0-300 volt single phase 230 volt for 3 KVA make Bajaj or eor equivalent in approved makes. |
| 106 | Supply and fix Voltage stabilizer with 100% copper winding for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA . Make: Microtek/Voltas or equivalent. |
| 107 | Taking out carefully existing unserviceable copper PVCflexible 3 core cable and supply and fixing PVC sheathed copper cable 3 core of size 40/ 00.0076 complete all as specified and directed. |
| 108 | Taking out carefully existing unserviceable copper PVCflexible 3 core cable and supply and fixing PVC sheathed copper cable 3 core of size 70/ 00.0076 complete all as specified and directed. |
| 109 | M&L for replacement of unserviceable existing reverse valve copper tubing as required on site for AC all as specified and directed. |
| 110 | Servicing and repairing of Aqua Guard water purifier of any cap with following replacement of make :- Aqua guard, Kent complete all as specified and directed. |
| 111 | (a) Primary filter Small |
| 112 | (a) Primary filter Long |
| 113 | (c) Carbon In Line Candle |
| 114 | (d) Inline Sediment Candle |
| 115 | (e) Long CTO Candle |
| 116 | (f) Booster Pump 100 gpd |
| 117 | (g) Booster Pump Head |
| 118 | (h) SMPS Power Supply |
| 119 | (j) Solenoidal ValveCopper |
| 120 | (k) 100 GPD membrane |
| 121 | (l) PVC pipe gripper at Primary filter ( set of two) |
| 122 | (m) Replacement of Float Valve switch |
| 123 | (n) PVCpipe of 1/4\" as per exiting size |
| 124 | (o) Primary filter case with clamps |
| 125 | (p) Membrane Hosing A per Existing size |