| 1 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 2 | Demolition of brick work orstone/ boulder masonry, built in cementmortar including all quoins, pillars etc. complete all as specified and directed. |
| 3 | Demolition of cement concrete in ground floor and paving n exc 15 cm thickness (below or above the ground level) built in cement mortar complete all as specified and directed. |
| 4 | Demolition of RCC work of any description and in any position etc all as specified. |
| 5 | M&L for Brick work with old size subclass ‘B’ bricks, straight or curved on plan exc 6 m meanradius builtin cement mortar 1:4 etc,complete complete all as specified and directed. |
| 6 | Ditto but except bricks completeall as specified and directed. |
| 7 | M&L old size Brickwork with sub-class `B\" brick old size straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 8 | M&L for PCC1:4:8 type D-2 (using 40 mm gradedstone aggregate) as in foundation filling,mass concrete etc complete all as specified. |
| 9 | M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in benching of surface channel as in drains and finishing complete all as specified and directed. |
| 10 | M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc (inner girth only measured) complete all as specified and directed. |
| 11 | M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in coping, kersbs, mud stops rounded or chamfered in edges, posts, holdfasts etc, finish even & fair without using extra cement,complete all as specified and directed including necessary formwork as per site requirement |
| 12 | M&L for Rendering 15 mm thick on new preparedbrick work or concrete surface on wallin cement mortar 1:4 with water proofing compound finished fair and smooth without using extra cement complete all as specified and as directed.Note: Water proofing compound shall be measured seprately. |
| 13 | M&L for rendering 10 mm thick cement plaster in CM 1:4 on fair faces of brick work or concrete surface finished fair and smooth without using extra cementcomplete al as specified. |
| 14 | Supply only liquid water proofing compound complete all as specified and directed. |
| 15 | M & L for preparing new plaster surfaces of walls including chajjas, facias etc. and applying premium acrylic smooth exterior paint (100% acrylic) with silicone additives in two or more coats, that offers an anti-algal, excellent resistance to ultraviolet radiation, dirt pick up resistance (DPUR) property, rich sheen, low VOC, of approved shade over a coat of primer as per the manufacturer’s instructions, applying using brush, keeping the gap/ the interval in subsequent coats, including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed. Note: - The paint shall be as per Apex Ultima of Asian Paints or equivalent of Make as approved by GE. |
| 16 | M&Lfor RCC (Reinforced Cement Concrete) (nominal mix) Type B1 1:2:4 using (20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 17 | M&Lfor RCC (Reinforced Cement Concrete) (nominal mix) Type B1 1:2:4 using (20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc complete all as specified and directed. |
| 18 | M&Lfor RCC (Reinforced Cement Concrete) (nominal mix) Type B1 1:2:4 using (20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span etc complete all as specified and directed. |
| 19 | M&Lfor RCC (Reinforced Cement Concrete) (nominal mix) Type B1 1:2:4 using (20 mm graded stone aggregate) as in chajjas etc complete all as specified and directed. |
| 20 | M&L for precast renforced concrete 1:2:4, type B-1 1:2:4(using 20 mm mm graded stone aggregate) for drains/manhole cover slab set and jointed in CM 1:6 including necessary formworketc complete all as specified and directed. Note: Reinforcement shall be measured & paid seprately. |
| 21 | M&L for Formwork to faces of wall, parapet, coping, lintel, landing, to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter not specified complete all as specified and directed. |
| 22 | M&L for TMT bars 10 mm dia and above cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 23 | M&L for TMT bars 6 mm to 8 mm dia cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 24 | Demolition and breaking up drain pipes (RCC/SGSW/AC) pipe of Internal dia 150 mm complete all as spd and directed |
| 25 | Demolition and breaking up drain pipes (RCC/SGSW/AC) pipe of Internal dia 200 mm complete all as spd and directed |
| 26 | M&L for 150 mm dia reinforced concrete (RCC) pipes, class NP2 laid and jointed complete with collars complete all as spd and directed. |
| 27 | M&L for 200 mm dia reinforced concrete (RCC) pipes, class NP2 laid and jointed complete with collars complete all as spd and directed. |
| 28 | M&L forheavy duty vitrified parking tiles of size 300 x 300 x 15 mm thick fixed over and including 15 mm thick screed bed in cement mortar 1:4 fixed using spacers of 5-6 mm and joints filled with epoxy over 75 mm thick cement concretetype D2 (1:4:8), using 40 mm graded aggregate including demolition of existing path/hardstanding of any type and pattern complete all as specified and directed. |
| 29 | M&L for factory made 60 mm thick rubberised interlocking paver blocks confirming to IS 15658-2006 of cement concret M-35 designation (compressive strength) of mixed colour, with grey cement and pigment laid over 25 mm thick sand cushion with compaction etc including demolition of existing tiles of any type and pattern complete all as specified and directed. |
| 30 | Dismantling posts or struts (wood, steel or R.C.C.) any section, embedded in Concrete, brick work, masonry, etc. including taking out embedded portion and making good disturbed ground, complete all as specified and directed. |
| 31 | All as per sl item No. 31 above but embedded on natural ground. |
| 32 | Dismantling barbed wire any type and any size complete all as spd and directed |
| 33 | S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, running bars, for chain link fencing including embeding in concrete and similar work conforming to Fe-290 Gde E-165complete all as specified and directed |
| 34 | S&F MS bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut not exceeding 30 cm long and dia of bolt not exc 12 mm etc, complete all as spd & directed |
| 35 | S&F mild steel tubular work as in doors or gates etc drilled for fixing of steel sheeting or other covering doors etc including hinges for hanging or sliding complete with all items related to door fittings etc complete all as specified and directed |
| 36 | S&F galvanised 2 strand 2.24 dia steel barbed wire, barbed with 2 mm dia barbs at 75mm(approx) spacing and straining and fixing to any type of post, straining bolts, including securing or tying at crossing with and provision of galvanised MS wire , staples or steel pins etc.complete all as specified and as shown on drawing including straining bolts as specified and directed Note: Each line of wire shall be measured separately. |
| 37 | Supply only chain link of MS galvanisd fencing, any size or typecomplete all as specified and directed |
| 38 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc including provision of binding wire including dismantling fencing wire mesh, any type complete all as specified and directed |
| 39 | M&L for preparation of new steel/iron surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 40 | M&L for preparation of old painted steel/iron surfaces of any description, over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 41 | M&L preparation ofold surfaces of wall and applying two coat of water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & colour stay technology, excellent dirt pick up resistance with low VOC less than 50Gram/Litre as per LEEDS specifications having anti algal properties in two coats @1.79 litre (Undiluted)/10 Sqm diluted with water as per manufacturers instructions applied with fully automatic airless spray machine ofpaint application with a flowspeed of minimum 1 litre per minute having a pressure of 3300 PSI. Note : (i). Subsequent coat of painting shall be done after allowed 6 to 8 hrs to dry the painted surface.(ii) The work shall be executed from authorized applicator of makeapproved by Garrison Engineer.(iii) Colour of Exterior Emulsion paint shall be approved by Garrison Engineer. |