| Sl. No. | Item Description |
| 1 | M&L for clip in type armstrong metallic powder coated 0.50 mm thickceilinh with GI framework made of standard TEE , Angle or any other section as in grid type ceiling framework as approved by GE . Ceiling shall be hanged to roof trusses / purlin rafters with the help of GI wire not less than 4 mm dia at an interval n.exc 1 m , the size metallic powder coated ceiling tiles is 600 mm x 600 mm. Complete all as specified. |
| 2 | S&F false ceiling with exposed GI system using “SILHOUETTE XL 15 mm (Nominal) designer Grid \"Armstrong\"white or Global white with black reveal and 600 x 600 x 15 mm thick prime fine fissured micro look white/coloured tiles (superfine 15mm/silhouette). Making necessary framework for AC ducting, if any and necessary cutouts for diffusers and light fittings, taping and finishing to proper line & level and incl dismantling old undervicable false ceillingcomplete all as per manufacturer’s instructions and as directed. |
| 3 | Preparation of old surfaces of walls including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc.; rubbing down and stopping of surfaces using sand paper and applying one coat of oil bound distemper, complete all as specified and directed by the Engineer-in-Charge. |
| 4 | Dismantling ceiling board including framework of any description in any position. Complete all as specified and directed. |
| 5 | S&F Mild steel framed work conforming to Fe-290 Gde E-165 quality-A as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, walkways, railing, barred iron doors including side hung gates with pintel hinges, spops, hand made sliding bolts, framed work of water tanks, door chowkats and similar works complete all as specified |
| 6 | M&L Preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamelled paint over one coat of red oxide primer. |
| 7 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/disintegrated rock etc Complete all as specified and directed. |
| 8 | M&L for 75 mm thick cement concrete type D-2 1:4:8with )using 40 mm graded stone aggregates) asin sub base of flooring etc Complete all as specified and directed. |
| 9 | Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved, design & pattern as in footpath , parks , lawns,drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling joints with sand andcutting of paver block as per required size and pattern,finishing and sweeping extra sand etc Complete all as specified and directed |
| 10 | M&L for cement concrete type B0 1:2:4 (using 12.50 mm graded stone aggregate) as in coping benching, gola, slightly rounded and similar items complete all as specified and as directed. |
| 11 | Removing excavated material to distance not exc50 metre and depositing where directed at a level n.exc 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge |
| 12 | Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each all as specified and directed by Engineer - in – Charge. |
| 13 | Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each andall as specified and directed by Engineer - in - Charge. |
| 14 | S&F powder coated anodized aluminum frame for partition, doors, windows, ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 15 | S&F powder coated Anodised aluminium door, fixed/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified. |
| 16 | S&F powder coated Anodised aluminium window and ventilator shutters, fixed/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified. |
| 17 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 18 | S&Ffor 4.8/5.0 mm thick sheet glass ordinary quality and glazingeach pane n exc 0.50 Sqm fixed with neoprenerubber gasket in aluminium frame work complete all as specified. |
| 19 | S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to steel frames with tinned tacks, or galvanized wire staples, or fixed to wooden frames with first class hard wood bead,complete all as specified and directed. |
| 20 | S& F for Hand rails, half round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wiremesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165etc complete all as spd and directed. |
| 21 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on planand n exc 1.5 m in depth and getting out soft/loose soil complete all as specified. |
| 22 | S&F in repair re-inforced punched concertina coil of 600 mm dia in stressed position hot dip galvanized steel wire coated with CLR anti corrosive paints making diamond shape with the help of drove tail clips (18 SWG ) , the concertina coil is to be fixed with barbed wire at points where coil touched the bottom barbed wire with the help of lug rings(24 SWG ) including all fittings like fasteners clips , steel lug rings etc complete all as shown in drg all as specified and directed |
| 23 | Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings withand provision of galvanised mild steel wire, staples or steel pins etCas directed complete all as specified. |
| 24 | M&L PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping,apex stones , bed plates etc including necessaryformwork complete all as specifed and directed. |
| 25 | Excavation(soff/disintegrated rock) in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface |
| 26 | M&L for surface dressing in soft/loose soil n.exc 15 cm deep complete all as specified and directed |
| 27 | M&L PCC 1:4:8 type D2 (using 40mm graded agg) as in foundation filling and mass concrete etc complete all as spd and directed. |
| 28 | M & L modular bricks in cement mortar 1:6 with Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in etc complete all as spd and directed. |
| 29 | M & L for rendering 15mm(10+5 mm)thick in two layers in cement mortar 1:4 including mixing water proofing compound as per manufacurers instructions over a backing coat of 10mm thick in CM 1:4 on concrete or brick masonry surfacesand finishing the top surface even and smooth without using extra cement complete all as specified and as directed.Note: Water proofing compoundwill be measured and paid separately. |
| 30 | Supply only integral water proofing compoundof approved make |
| 31 | M&L Preparing of new surface of wall and applying twocoatsof Cement base paint over a coat of alkali resistent primer.Complete all as specified and directed |
| 32 | M & L for 75 mm thick, PCC 1:3:6, Type C-1, using 20mm graded stone aggregate as in plinth protection, surfaces finished even and smooth complete all as specified and as directed. |
| 33 | M & L for Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding15 cm thick watered and rolled/rammed to a true surface complete all as specified. |
| 34 | M & L for 100 mm thick, PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in sub floor, floor ect, surfaces finished even and smooth complete all as specified and as directed. |
| 35 | M & L for 25 mm thick, PCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in floor, surfaces finished even and smooth complete all as specified and as directed. |
| 36 | Chequered cement concrete tiles 25cm x 25cm x 25mm thick in floors / path set,jointed & pointed in neat cement slurry using grey cement and no pigment laid over and including 15mm thick screed bed in cement mortar (1:6) including necessary cutting as per site requirement complete all as specified. |
| 37 | M & L Mild steel work as in roof trusses including special shaped washers etc complete using ERWor induction butt welded tubes coforming to IS 1161-1979 grade st-240 etc including a shop coat of red oxide primer complete all as speciied anddirected. |
| 38 | S&F Expanded metal, cut to length,bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, Complete all as specified. |
| 39 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 40 | Demolition ofstone / boulder, brickwork built in cement mortar including all quoins, arches, pillars etc all as specified. |
| 41 | M&LCement concrete Type B2 1:3:6 (40 mm graded aggregate) asin foundation filling and mass concrete for column post. Complete all as specified |
| 42 | M & L Mild steel work as in posts, sturts & vertical colmns using ERWor induction butt welded tubes coforming to IS 1161-1979 grade st-240 etc complete with gusset plates,base plates etc including a shop coat of red oxide primer complete all as specified and directed |
| 43 | M&L 100 mm thick PCC 1:4:8 tybe D-2 using 40mm stone aggregate as in subbase. |
| 44 | Cutting holes in Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall, n exc half brick walls,Ditto, but in brick walls built in cement mortar or cement lime mortar and stone walls built in limemortar,complete all as spd and directed. |
| 45 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock. |
| 46 | M&L for RCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete, complete all as specified and shown on drgs. |
| 47 | Formwork to sides of concrete foundations, rough finished surfaces of flat concrete, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter,etc complete all as spd and directed. |
| 48 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed. |
| 49 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as inColumns, pillars, piers, posts and struts complete all as specified. |
| 50 | Use and removal of steel formwork to sides of pillars, posts, struts, piers, columns and stanchions of any shape / cross section for rough finished surfaces of concrete complete all as specified and as directed. |
| 51 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Beams, cantilevers, bressummers, lintel over 1.5 span complete all as specified. |
| 52 | Use and removal of steel formwork to sides and soffits of floor or roof beams, beam launchings, girders, bressummers, lintels,cantilevers, shelves including supports, overhangs, etc, splays between floors and beams and similar works for rough finished surfaces of concrete complete all as specified and as directed. |
| 53 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as inSlabs supported on walls,beams and columns in floors,roofs, complete all as specified. |
| 54 | Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including rough finished surfaces complete all as specified and directed. |
| 55 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Chajjas complete all as specified. |
| 56 | S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 57 | S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 6 mm to 8 mm, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 58 | S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 59 | M & L for Preparing the surfaces of concrete roof and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thickin cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cementincluding mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight notless than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately. |
| 60 | M&L for rendering 15 mm thick in cement mortar (1:6) onbrick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified. |
| 61 | M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling finished even and smooth without using extra cement complete all as specified and as directed. |
| 62 | M & L for preparing newly plastered ceiling surfaces and applying threecoats of white washing complete all as specified and as directed. |
| 63 | M & Lpreparation of newly plastered surfaces of wall and applying two coats ofOBD over a coat of primer including preparation ofsurfaces on walls as specified and directed. |
| 64 | M&L Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick Screed bed or bedding layer of mortarfor laying floor finishes in CM 1:6 |
| 65 | Preparation of new wooden surface and applying two coats of synthetic enamel paint over a coat ofpink primer complete all as specified and directed by Engineer-In-Charge. |
| 66 | Pressed steel frames made out mild steel sheet 1.25 mm thick, with size of frame 125 mm x 60 mmfor doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc and applyinga shop coat of red oxide primer including providing PCC 1:3 :6 type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified and as directed by the Engineer-in-Charge |
| 67 | S & F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats all as specified and directed by Engineer - in - Charge |
| 68 | S & F flush shutter 35 mm thick solid core construction with block board core and plywood face panels commercial type on both sides with lipping / frame to match all as specified and directed by Engineer - in - Charge. |
| 69 | S & F mild steel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm long all as specified and directed by Engineer - in – Charge . |
| 70 | S&F 300mm Aluminium alloy, anodised,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 71 | S & F aluminium handle cast type anodised, 125 mm long all as specified and directed by Engineer - in - Charge . |
| 72 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc completed all as specified. |
| 73 | M & L first quality coloured glazed ceramic, joint free tiles fixed in pattern of different colour including border of Size aera exc 0.15 Sqm but n.exc 0.20 Sqm & 7-8 mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid on and including 10 mm thick rendering in cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles, complete all as specified and directed. Note :- Pattern of the tiles will be decided by GE at the time of execution. |
| 74 | M&L Roughning surfaces of old concrete floor by picking ,sweeping clean and washing down with water to remove dust etc including brushing neat cement slurry with 3 kg of cement per sqm |
| 75 | M&L 7 mm to 8 mmthickJoint less light ceramic tiles Ditto but in Dado/Skirting including Rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as backing coat.complete all as specified and directed by Engineer-in-Charge. |
| 76 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 77 | M&L for 75 mm thick cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregates) asin sub base of flooing etc complete all as specified and as directed. |
| 78 | M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4)for bedding of tilescomplete all as specified. |
| 79 | M&L for ColouredVitrifiedCeramic tiles 9-10 mm thick (Square/rectangular) oflight Shade , polished, area of each tileexceeding 0.36 sqm but n exc. 0.72 Sqm, fixed in floor/skirting etc overset and jointed in neatcement slurry and pointed in coloured cement to match with coloured tiles complete all as specified and as directed. |
| 80 | M&L for preparation ofnewly plastered surface of wall and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification complete all as specified and as directed |
| 81 | M&L for preparation of newly plastered surfaces of wall and applyingTwo or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 82 | M&L for providing 3mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform all as specified. |
| 83 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 84 | S&F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 85 | S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified. |
| 86 | S&F 150 mm size extruded aluminium alloy handles fabricatedtype anodised and fixed. |
| 87 | S&F 250 mm long aluminium alloyanodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified. |
| 88 | S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 \"D\" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc including 4 mm sheet glass in window & 4 mm frosted glass in vent alongwith 0.36mm nominal dia of wire and average width of aperture 1.40mm in mesh shutter complete all as specified and as directed.Make : NCL type-4000 Series |
| 89 | Providing and fixing decorative PVC louvred panels on wall surface, made from extruded rigid PVC profiles of approved quality , thickness not less than 12mm, designed with verticle or horizontal slats (louvers) for asthetic wall cladding purposes, fixed to a GI/Wooden framenor directly to wall using stainless steel screws, adhesive, or mechanical fastners as per manufacturer\"s specifications, including surface prepration, edge trimming, joints finishing, and making good the disturbed surfaces. Complete all as specified and directed. |
| 90 | S & F Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, forming holes, without any attachment confirming to Fe 410-S complete all as specified. |
| 91 | E&M items |
| 92 | Taking down old point wiring complete for light/fan/socket(5/15 Amps) bell point etc complete with all light fittings accessories, such as switch sockets 5/15 Amps ceiling rose etc including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. |
| 93 | M&L for concealed point wiring with PVC insulated and unsheathed, single core FRLSH cable of size 1.5 sqmm stranded copper conductor, 1100 Volt grade, drawn into and including PVC rigid conduitnot less than 20mm dia, medium grade, ISI markedwith and including 1.5 Sqmm unsheathed green colour stranded copper conductor FRLS cable for continuous earth wire and including sunken pressed steel concealed terminal boxes of suitable size made out of 1.2 mm thick sheet covered with 2.6 mm thick white hylam sheet cover of suitable size formounting switches/sockets/fan regulators or Modular flush box for mounting modular switches/sockets/regulators etc including cutting chasing in wall and making good disturbed surface with existing colour complete all as specified & directed for the following :- |
| 94 | (a) One light/fan point controlled by one switch |
| 95 | (d) One socket outlet 2/3 pin 5 amp, multipurpose on same board with other switches |
| 96 | (c) One switch/socket outlet point 2/3 pin 5 amp multipurpose on independent board |
| 97 | All as per Item No 92 above, but with FRLS cable 2.5 sqmm stranded copper conductor for switch/socket outlet 5 Pin,15 Ampsmultipurpose controlled with 2.5 sqmm copper conductor FR cable as continuous earth wire of green colour on independent board. |
| 98 | Supply and fix switch piano flush type, 5 amps, 230V AC,single pole, one way |
| 99 | Supply and fix,switch piano flush type 15 amps, 230V AC single pole one way |
| 100 | Supply and fix,socket out let 2 IN 1,multipurposesuitable for3 pin 5/15 amp flush type. |
| 101 | Supply and fix Modular Switchflush type 6 Amps single pole, one waycomplete all as specified. Make:- Legrand Mylinc Series, Crabtree Athena Series, Anchor ROMA PLUS |
| 102 | Supply and fix Modular Socket outlet, multi purpose, 5 Pin combined 6 Amps flush typecomplete all as specified. Make:- Legrand Mylinc Series, Crabtree Athena Series, Anchor ROMA PLUS |
| 103 | Supply and fix Modular Socket outlet, multi purpose, 2/3 pin combined 16 Amps universal socketcomplete all as specified. Make:- Legrand Mylinc Series, Crabtree Athena Series, Anchor ROMA PLUS |
| 104 | Supply and fixModularSwitch 16 Amps single pole, one waycomplete all as specified. Make:- Legrand Mylinc Series, Crabtree Athena Series, Anchor ROMA PLUS |
| 105 | Supply and fix,socket out let multipurpose suitable for 2/3 pin 5 amp flush type |
| 106 | Supply and fix angle/batton type holder insulated body in white colour |
| 107 | Supply and fix,ceiling rose,phase,polycorbonate isolated body forsurface type, three terminals. |
| 108 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, Decorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient high transmissitivity diffuser, high lumen ouput 230 volts and intregrated electronic driverconnector block etc. complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make :- Havells Cat part No LHEXBLP7PN1W022 or its equivalent in Philips, Wipro, Bajaj |
| 109 | S & F for ceiling fan, 230 Volts, 50Hz, 1200 mm sweep with down road, canopy, blades, BLDC motor etc and service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceiling rose with remoteto fan teriminal includingwritting the MES Number with synthetic enamel paintcomplete all as specified and as directed.Make Havells Cat Part No FHCNF5SWHT48 or its equvalent in Crompton,Usha, Bajaj, |
| 110 | S & F for sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 111 | S & F for sheet metal enclosure MCBDBSPN4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 112 | Supply and fix MCB SPN 6 to 32 amps 10 KA, \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge. |
| 113 | Supply and fix MCB SP 6 to 32 amps 10 KA, \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge. |
| 114 | M&L for Sub main wiring in repairs with two runs ofsingle core FRLSH PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including concealed non metallic rigid PVC conduit of not less than 25 mm dia including one run of PVC insulated unsheathed 2.5 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in concealed wiring system by cutting of wall and making good disturbed surface of wallall as specified and directed.Note:- Two runs of 4.00 sqmm cable,one run of 2.50 sqmm cable and one run of PVC conduit will be measured as one unit. |
| 115 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for Bldg security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 30/35 watts with pre wired andnecessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make :-Bajaj Cat part No ENXT P 24L WH CR PC SD (Edge plus series)or its equivalent in Philips, Wipro, Havells. |
| 116 | Sppply & Laying XLPE insulated,armoured, electric cable 10 Sqmm 2 Corewithaluminium conductor,1100 volts grade, laid in trenches, fixed on poles / walls or passing through pipes including provision of necessary lugs and glands&makingnecessary connectionincluding taking down old unservicable cable of any corecomplete all as specified and directed. |
| 117 | Excavating in trenches, in any type of soilnot exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etcand getting out in any type of soil complete all as specified and directed. |
| 118 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.. |
| 119 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 120 | Supply laying and jointing GI pipe\"light grade\" 40 mm bore in trenches/under floors or roads/ along poles/ on wall incl clamps for protection of cables incl fittingscomplete all as specified and directed. |
| 121 | M & L for clean and dry sand (un washed) in trenches incl spreading and levelling for cushioning of UG cable completeallspecified and directed. |
| 122 | M & L for brick size sub class ‘B’ (modular size), laidflat in trenches for protection of cable complete allas specified and directed. |
| 123 | M&L of earthing complete with GI steel earth plate electrode 60cm x 60cmx6.0mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI strip 32x6mm by means of nuts, bolts checks nuts and washers made of GI earth wire protected by GI pipe 40mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 using 20mm graded aggregate, pre-cast RCC (1:2:4) type-B, over slab 30cmx30cmx10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 3 of MES schedule Part-I and testing after completion. |
| 124 | Supply and fix switchflame proof rotary type with termination box in LM6, 16A, single pole 250V |
| 125 | Supply and fix Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+ earth |
| 126 | Supply and fix exhaust fan,Flame proof steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed by Engr-in-Charge. |
| 127 | Supply and fixing LED light fitting 2 x 16Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.complete all as specified and as directed. Make :- Havells Cat part No LHEXBLP7PN1W022 or its equivalent in Philips, Wipro, Bajaj |
| 128 | Supply and fix exhaust fan,steel body AC single Phase. 230V of size 380 mm sweep with, blades, and frame and louvers complete all as specified and directed by Engr-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail