| 1 | Excavation in trenches not exceeding 1.5mtr wide and not exc 1.5mtr depth and getting out in soft and loose soil complete all as specified and directed by Engr-in-Charge. |
| 2 | Excavationintrenchesnotexceeding1.5 mtr wideand exceeding1.5 mtr but n.exc 3.0 mtr indepthandgettingoutin any type ofsoilfortakingup orlaying ofcable, foundation of poles, stay etccomplete all as specified and directed by Engr-in-Charge. |
| 3 | Returning and filling in of excavated material ay type including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed by Engr-in-Charge. |
| 4 | Removal of surplus excavated material of any type not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 5 | Material and Labour for Sand cushioning/sand coveringfor underground cable protection complete all as specified.Note: Punned thickness only will be measured and paid complete all as specified and directed by Engr-in-Charge. |
| 6 | Supply and laying sub class \"B\" bricks of old size (225mm x 115mm x 75mm) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 7 | All as per srl item No 6 here-in-before but using old bricks obtained under srl item No1 here in before complete all as specified and directed by Engr-in-charge. |
| 8 | Material and Labour for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection complete all as specified and directed by Engr-in-Charge. |
| 9 | Material and Labour for Cutting the tarmac / hard standings and excavating in trenches across the road for laying cablecomplete all as specified and directed by Engr-in-Charge. |
| 10 | Material and Labour for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) forbase of foundation of pole / stay including form work etc complete all as specified and directed by Engr-in-Charge. |
| 11 | Material and Labour for PCC type C2, 1:3:6 using (40 mm gradded stone aggregate) in foundations complete all as specified and directed by Engr-in-Charge. |
| 12 | Material and Labour for PCCtype B-1, 1:2:4 using (20 mm gradded stone aggregate) for coping, including form work complete all as specified and directed by Engr-in-Charge. |
| 13 | Supply and fix in replacement Electronic Timer suitable for street light timer panel complete all as specified and directed by Engr-in-Charge. |
| 14 | Supply and fix in replacement 3/4 Pole Contactor suitable for street light timer panel complete all as specified and directed by Engr-in-Charge. |
| 15 | Taking down defectivestreet light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as specified and directed by Engr-in-Charge..Note:a) The M/L forItems like ballast, lamp, igniters, capacitors, electronicdrivers,surge protection devices etcshall be measured and paid separately under relevant items herein under this Schedule.b) Necessary tools like ladders & other T&P reuired etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L forrepairs toLED panel is not included in the scope and shall be measured and paid separately. |
| 16 | Supply only the following spares suitable for street light/food light/post top lantern light fittings complete all as specified and directed by Engr-in-Charge. |
| 17 | Electronic driver suitable for 120 to 150 W LED light fitting |
| 18 | Electronic driver suitable for 90 to 100 W LED light fitting |
| 19 | Electronic driver suitable for 70 to 80 W LED light fitting |
| 20 | Surge protection device of capacity 10 KV suitable for LED light fitting |
| 21 | Dismantling LED light fitting ofany make of following capacity ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items complete all as specified and directed by Engr-in-Charge. |
| 22 | 120 to150 W LED light fitting |
| 23 | 90 to100 W LED light fitting |
| 24 | 70 to80 W LED light fitting |
| 25 | Taking down old unserviceable street light/Flood light fittings from any height and Supply & fixing LED street light/flood lifht fittings of following capacity comprising of epoxy powder coated housing, enclosed with cover in frame, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc completeand testing on completion complete all as specified and directed by Engr-in-Charge.Note: The GI pipe bracket if requiredwill be measured and paid separately under relevant schedule items |
| 26 | 60 Watt LED Street light |
| 27 | 90 Watt LED Street light |
| 28 | 100 Watt LED Street light |
| 29 | 120 Watt LED Street light |
| 30 | 120 Watt LED Flood Light |
| 31 | 150-170 Watt LED Flood Light |
| 32 | Taking down old unserviceable post top lantern fittings and Supply & fixing post topluminarie LED type of 40 W with IP 65 protection with die cast aluminium graphite grey powder coated finished body , polycarbonate opal diffuser, low power warm white (WW) LEDs with better heat dissipation, high efficient constant current electronic driver having operating voltage range from 140 to 280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 10 KV etc complete suitable for 60 mm OD pipe entry including suitable size loop in loop out boxeSupplying and Fixinglexible 3 core 1.5 Sqmm copper connecting cable from loop in loop out box to fitting etc complete all as specified and directed by Engr-in-Charge. Note: The GI pipe if required will be measured and paid separately under relevant schedule items |
| 33 | Supply and fixing LED Solar street light fitting 20 Watt including lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed by Engr-in-Charge. |
| 34 | Supply & laying or fixing or passing through pipe or in cable ducts, 1100 volts grade,XLPE, armoured, electric power cables (heavy duty) with aluminium conductorof the following size including dismantling old one complete all as specified and directed by Engr-in-Charge. |
| 35 | 35 Sqmm 3.5 Core |
| 36 | 25 Sqmm 4 core |
| 37 | 16 Sqmm 4 core |
| 38 | 10 Sqmm 4 core |
| 39 | Supply and erection, testing and commissioning of steel tubular swaged poles type 410 SP- 31 (9 meter long) complete with CI base plate,, finial taper plug, bolts, nuts & screwscomplete all as specified and directed by Engr-in-Charge.. |
| 40 | Supplying and Fixing in repair PVC insulated 3 core 1.5 Sq mm stranded copper conductor cable for connecting junction box to street light fittingtesting and commissioning complete all as specified and directed by Engr-in-Charge. |
| 41 | Supply and fixing timelite distribution boards (street light DBs) 65 A 3 polewith 230 V Astronomical time switch complete all as specified and directed by Engr-in-Charge. including dismantling old one . |
| 42 | Supplying and Fixing loop-in/loop-out box of internal size 250 x 200 x 100 mm made out ofFRP(Hot moulded type) with weather proof canopy and locking screws along with with 6 Amps MCB - 01 No, 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed toto steel tubular pole using 25 x 3mm MS clamp, including suitable gland and lugs for connecting cable complete all as specified and directed by Engr-in-Charge. |
| 43 | Material and Labour for bracket for street light fitting made out of40 mm bore pipe light grade GI tube bent to shape required, not less than 1.20 meter long,fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete all as specified and directed by Engr-in-Charge. including dismantling old defective. |
| 44 | Material and Labour for preparation of old painted steel surfaces of 9 m long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with 125 mm dia adhesive sticker with white letters/ blackground etc complete all as specified and directed by Engr-in-Charge. |
| 45 | Material and Labour for fixing in repair adhesive sticker radium type red coloured water resistant of approx 2 inches width around the circumference of pole at a approx height of two meters complete all as specified and directed by Engr-in-Charge. |
| 46 | Supply and fixing Weather proofflat twin core cable of aluminium conductor of complete all as specified and directed by Engr-in-Charge following sizes:- |
| 47 | 16 Sqmm 2 Core |
| 48 | 10 Sqmm 2 Core |
| 49 | 6 Sqmm 2 Core |
| 50 | Supply & fixing of GI Reducer assembly for street light bracket of sze 50 to 40 mm complete all as specified and directed by Engr-in-Charge. |
| 51 | Supplying and Fixing in replacement Retro Reflective installation sign boards of size 5 feet x 4 feet fabricated out of 16 gauge MS sheet frame duly welded/riveted with MS square pipe of size 25mm x25mm at height 2.00 meter above ground level on stainless steel heavy dutypipe of size 80mmbore embedded 60 CM in PCC 1:2:4 type B 1 block of size 45cmx45cmx60cm including necessary excavation and earth work.The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape.The writing matter will be in English language on both sides with reflective adhesive painter tapes complete all as specified and directed by Engineer- in- Charge. |
| 52 | Supply and fix in repairs Isolator 415 Volts of following current carrying capacity complete all as specified and directed by Engr-in-Charge. |
| 53 | 4 Pole 63 Amps |
| 54 | 4 Pole 100 Amps |
| 55 | Cuting of trees / bushes in surrounding of LT Panels/Transformer yard of any size and complete cleaning of grass upto 1.5 mtr radius area around the panel in every quarter complete all as specified and directed by Engr-in-Charge. |
| 56 | Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work orderand shall be verified by the Engr-in-charge. |