| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided including removing of rubish from site complete all as specified and directed. |
| 2 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided including reinforcement cut as required to facilitate demolition and removing debries from site of work completeall as specified and directed. |
| 3 | Dismantling of timber scantling 40 Sqcm and over in section, in any position in framed work and removing materials from site of work complete all as specified and directed. |
| 4 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for and removing materials from site of work complete all as specified and directed. |
| 5 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc including brushing neat cement slurry with 3.00 kg of cement per sqm completeall as specified and directed. |
| 6 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises completeall as specified and directed. |
| 7 | Dismantling of stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed. |
| 8 | Taking down chowkats or frames with shutters n.exc. 1.50 Sqm each (without taking off shutters from the frames) complete all as specified and directed. |
| 9 | Taking down chowkats or frames with shutters exc. 1.50 sqm but n.exc 4.00 sqm each (without taking off shutters from the frames) complete all as specified and directed. |
| 10 | Taking down shutters of any description exc. 1.00 Sqm but n.exc. 2.00 Sqm each complete all as specified and directed. |
| 11 | Taking down wooden door/window of area n.exc 4.00 sqm each carefully and refixing in the same opening after necessary repair such as stay handle etc and making good to existing surface with cement mortar (1:3) complete all as specified and directed.Note:- Concrete required for fixing hold fast shall be included in the quoted rate. |
| 12 | Taking down chowkats or frames with shutters exc. 1.50 sqm but n.exc 4.00 sqm each (without taking off shutters from the frames) and refixing in same opening with using hold fast, minor cement concrete work and making good complete all as specified and directed. |
| 13 | Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for key, scrubbingdown with water etc. and removing debrish from site complete all as specified and directed. |
| 14 | Demolition of brick work or stone boulder masonry, built in cement mortar including all quoins, arches, pillars etc.including removing of unserviciable material from site complete all as specified and directed. |
| 15 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 16 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 17 | Supply and fix 15 mm bore steel tubesmedium grade, galvanised, with all fitting and fixed to walls, ceilings, roofs or laid in floorscomplete all as specified and directed. |
| 18 | Supply and fix 20 mm bore steel tubesmedium grade, galvanised, with all fitting and fixed to walls, ceilings, roofs or laid in floors complete all as specified and directed. |
| 19 | Laying / fixing only 15 mm bore steel water tubing with and including all fittings and fixed to walls and ceilings or laid under floorscomplete all as specified and directed.Note;- Serviciable GI pipe shall be refixed under this item obtained from item No 15.00 after taking up/ down. |
| 20 | Laying / fixing only 20 mm bore steel water tubing with and including all fittings and fixed to walls and ceilings or laid under floorscomplete all as specified and directed.Note;- Serviciable GI pipe shall be refixed under this item obtained from item No 16.00 after taking up/ down. |
| 21 | Material and labourfor 15mm thick rendering in cement mortar (1:4) on fair faces of brick work in two layers, first layer of 10mm thick and top layer of 5mm thick with using liquid water proofing coumpound (WPC) @ 200ml/50Kg bag of cement or as per manufacturers instructionand finish the surfaceseven and smooth without using extra cement as in wall complete all as specified and directed.Note : WPC will be measured and paid separately under respective item. |
| 22 | Material and labour for 10mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:6) andfinish the surfaceseven and smooth without using extra cement on wall complete all as specified and directed. |
| 23 | Material and labour for 5mm thick rendering onconcrete surfaces in cement mortar (1:3) andfinish the surfaceseven and smooth without using extra cementin ceiling complete all as specified anddirected. |
| 24 | Material and labour for preparation of new plastered surfaces of walls and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqmcomplete all as specified and directed. |
| 25 | Material and labour for preparation of new plastered surfaces of walls and applying two coats of acrylic washable distemper over a coat of alkali resistance primer including applying 1mm thick wall care putty complete all as specified and directed. |
| 26 | Material and labour for preparation of new plastered surfaces of wall and applying three coat of white wash completeall as specified and directed. |
| 27 | Material and labour for preparation of new plastered surfaces of ceiling and applying three coat of white wash completeall as specified and directed. |
| 28 | Materials and labour for complete removal of existing treatment of old decorated surfaces of walls and applying two coats of acrylic washable distemper over a coat of alkali resistance primer including applying1mm thick wall care putty including preperation of surface complete all as specified and directed. |
| 29 | Material and labour for preparation of old painted wooden surfaces of any description over 10 cm width or girthand applying one coat ofsynthetic enamel paint complete all as specified and directed. |
| 30 | Material and labour for preparation of old painted steel surfaces of any description over 10 cm width or girthand applying one coat ofsynthetic enamel paint complete all as specified and directed. |
| 31 | Material and labour for preparation of old decoratedsurfaces of wall and applying one coat of white wash complete all as specified and directed. |
| 32 | Material and labour for preparation of old decorated surfaces of ceiling and applying one coat of white wash complete all as specified and directed. |
| 33 | Material and labour for preparation of old decorated surfaces of walls and applying one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 0.715 litre/ 10 sqm complete all as specified anddirected. |
| 34 | Material and labour for preparation of new wooden surfaces of any description exc 10 cm width or girthand applying two coats ofsynthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 35 | Material and labour for preparation of new steel surfaces of any description over 10 cm width or girthand applying two coats ofsynthetic enamel paint over a coat of red oxide zinch chrome primer complete all as specified and directed. |
| 36 | Material and labour for machine cut cudappah stone slab 20-25mm thick as in shelf including rubbing and polishing complete including taking down existing shelf complete all as specified and directed. |
| 37 | Material and labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations completeall as specified and directed. |
| 38 | Material and labour for PCC (1:2:4), type B1, (using 20mm graded stone aggregate), as in coping, bed plate, kerbs, water troughs and like including weathering, slightly rounded or chamfered angles and throating, including necessaryformwork complete all as specified and as directed |
| 39 | Material and labour for brick work with sub class `B` bricks, old size,straight or curved on plan exc 6m mean radius built in cement mortar (1:6)complete all as specified and directed. |
| 40 | Materials and labour for half brick thick brick work with sub class `B` bricks, old size, straight or curved on plan to any radius built in cement mortar(1:4) complete all as specified and directed. |
| 41 | Material and labour for well-seasoned 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 42 | Material and labour for well-seasoned 2nd class hard wood plain fillets, square, rectangular or triangular in section, wrought, secured with nails or brads, sectional area exc. 13 sqcm but not exc. 25 sqcm including taking down existing fillets complete all as specified and directed. |
| 43 | Supply and fix 35mm thick 2nd class hard woodGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars) edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers as specified in SSR Part-I, Section 8, clause 8.24 (a) and fitted to chowkats complete all asspecified and directed. |
| 44 | Supply and fix factory made 30mm thick second class hardwood plain framed panelled shutters (any numbers of panels) with panels of timber flat both sides (feather edged) or of veneered particle board medium density, wood particle with commercial face veneers including framing is moulded on solid (for each side) and fitted to chowkats complete all as specified and directed. |
| 45 | Supply and fix factory made 30mm thick flush shutters, solid core construction, with block board core and plywoodpanels, commercial type, both face complete all as specified and directed. |
| 46 | Supply and fix factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65X150 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 47 | Supply and fix factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified and directed. Note: stainless steel butt hinges and necessary S Sscrews shall be paid separately under respective items. |
| 48 | Supply and fix powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed. |
| 49 | Supply and fix powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed. |
| 50 | Supply and fix anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed. |
| 51 | Supply and fix mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders, framed balusters, walk ways; railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 52 | Material and labour for second class hard woodsmall fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary\" labours; articles n. exc 200 cu. cm each complete all as specified and directed. |
| 53 | Suplly and fix 100mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 54 | Suplly and fix 100mm size stainless steel butt hinges, medium weight complete all as specified and directed. |
| 55 | Suplly and fix 150 mm long aluminum anodised barrel tower bolts cast type complete all as specified and directed. |
| 56 | Supply and fix 100mm long aluminium handles, cast type, anodized complete all as specified and directed. |
| 57 | Suplly and fix 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy complete all as specified and directed. |
| 58 | Suplly and fix in repair 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy complete all as specified and directed. |
| 59 | Supply and fix in repair mild steel 300mm long ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and directed. |
| 60 | Supply and fix in repair 18/19mm thick pre-laminated particle board, exterior grade, pre-laminated both side with decorative choice lamination including 2nd class hard wood leaping fixed to frame work complete all as specified and directed. |
| 61 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 62 | Supply and fix 4 mm thick sheet glass ordinary quality and glazing with oil putty/ aluminium bead/ rubber packing in square not exc 0.5 Sqm in each pane complete all as specified and directed. |
| 63 | Supply and fix 4 mm thick sheet glass ordinary quality and glazing with oil putty/ aluminium bead/ rubber packing in square exc 0.5 Sqm in each pane complete all as specified and directed. |
| 64 | Supply and fix 5 mm thick figured glass pin head type and glazing with oil putty in square n. exc 0.5 Sqm in each pane complete all as specified and directed. |
| 65 | Supply and fix stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 66 | Supply and fix in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 67 | Material and labour for RCC (1:2:4) type B-1 (using 20mmgraded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 68 | Material and labour for mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed. |
| 69 | Material and labour for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bres-summers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished flat surfaces of concrete complete all as specified and directed. |
| 70 | Supply and fix in repair kitchen stainless steel sink of steel grade-304, 1.00 mm thickwith plug, washers and wastes including bedding in cement mortar to dwarf wall or including cantilever cast iron brackets, connecting union etc., overall size 510 mm x 430 mm with bowl size 430mm x 380mm x 203mm including 32 mm bore waste coupling PTMT (minimum weight 45gms)and 32 mm dia PVC corrugated flexible waste pipe of 800 mm longcomplete all as specified and directed. |
| 71 | Material and labour for ceramic coloured tiles (premium quality) 7 to 8mmthick (square/rectangular) area of each tile exceeding 0.18sqm but not exc. 0.38sqmas in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar (1:6)complete all as specified and directed. |
| 72 | All as per item No 71.00 above but in skirting and dado laid over and including 10mm thick rendering in cement mortar (1:4) and -ditto-. |
| 73 | Material and labour for ceramic, non skid coloured tiles (premium quality) 7 to 8mmthick (square/rectangular) area of each tile exceeding 0.11sqm but not exc. 0.18sqmas in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar (1:6)complete all as specified and directed. |
| 74 | Material and labour for glazed ceramic tiles of size 300x450x7-8 mm (premium quality) coloured in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick cement plaster in cement mortar (1:4) completeall as specified and directed. |
| 75 | Material and labour for 20mm thick black marble (Jade black ) tiles machine cut in cooking plateform and jointed with grey cement slurry including cutting and polishing of type laid over and including 20mm thick screed bed in cement mortar (1:6)complete all as specified and directed. |
| 76 | Material and labour for cutting chases, pinning in brick wall making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 77 | Supply and fix in repair 15mm bore stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 78 | Fixing only in repair 15mm bore fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed. |
| 79 | Supply and fix in repair 15mm bore fancy type sink tap chromium plated brass, round headed single liver with quarter turn option with areator, swan neck type wall mounted with extruded brass made spindle and housing with wall flange, screwed down high pressure with long screwed shanks, screwed for iron pipe complete all as specified and directed. |
| 80 | Supply and fix in repair 15mm bore brass angle cock fancy type, chromium plated foriron pipe complete all as specified and directed. |
| 81 | Supply and fix in repairPVC connection pipe 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed. |
| 82 | Supply and fix in repair brass chromium plated shower rose 125mm size with or without swivel joint complete all as specified and directed. |
| 83 | Fixing only in repair 15mm bore fancy type pillar tap cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed. |
| 84 | Supply and fix in repair 125mm PTMT grating doom(minimum weight 40gms) complete all as specified and directed. |
| 85 | Supply and fix in repair vitreous china squatting pan (Orissa pattern) water closet (white) size 580x440mm with integral foot rests (excluding flushing cistern and flush pipe) complete including connection to trap and flushing pipe antisyphonage pipe etc including provision of PCC (1:5:10) type E2 in filling complete all as specified and directed. |
| 86 | Material and labour for toilet sunken floor treatment by approved applicator as under in the following steps including necessary safety measures complete. :-(a) Preparation: - Preparation of RCC slabs surfaces by mechanical means to remove laitance, loose particles, dust etc all as specified. (b) Pressure grouting: - Making holes/ chase opening/ groove into/ at the junctions of RCC slab/ beams to required depth and insert 1/2 inch dia PVC pipe/ pegs as nozzles at an interval of 300mm c/c and inject cement slurry admixed expanding grout admixture Cebex 100 @ 225 gm per bag of cement of make FOSROC or equivalent brand of make of STP Ltd / Asian Paints Ltd within the prefixed nozzles under pressure (2 to 2.5 kg/sqcm) using grouting pump to fill all possible pores and seal the nozzle holes with cement and sand mortar (1:3) mixed with Hydroproof chemical @ 5% by weight of cement of make FOSROC or equivalent brand of make of STP Ltd / Asian Paints Ltd.(c) Coving: Cleaning of all residues of dust and dirt at all the junctions of wall and slab after pressure grouting and dampened to reduce and limit its absorption capacity and make coving the junction of slab and vertical offsets with CM(1:4)mixed with and including WPC @ 5% by weight of cement. |
| 87 | (d) Bore Packing: - Preparing inside surface of core and PVC pipes by roughning using suiltable file to get better adhesion prior to packing works, cleaning surface by wire brushing followed water jet to remove all laitance or loose flaky particles and providing water tight form form on both sides of pipes for packing the holes using suitable arrangement and applying a coat of styrenebutadience based polymer coating using Nitobond SBR Latex of make FOSROC or equivalent brand of make of STP Ltd / Asian Paints Ltd to enhance adhesion between the packing material and other surfaces and packing the gap using Conbextra GP2 of make FOSROC or equivalent brand of make of STP Ltd / Asian Paints Ltd upto the surface of the bore whilst the Nitobond SBR Latex is in taccky state and then sealing with epoxy putty Nitocare VF of make FOSROC or equivalent brand of make of STP Ltd / Asian Paints Ltd.(e) Pond Test: - Pond the slab with water for 48 hours upto 100mm and mark the seeping areas if any.Note: - If seeping is found, then, treating the damp areas by injecting cement slurry mixed with expanding grouting agent Cebax 100 of make FOSROC or equivalent brand of make of STP Ltd / Asian Paints Ltd using pressure grouting pump again as specified. This process shall be done till seepage is arrested. |
| 88 | Supply and fix in repair 10 litre capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe complete all as specified and directed. |
| 89 | Supply and fix in repair vitreous china wash hand basin, white, flat back, size 550x400mm excluding taps, waste pipe, chain & plug and porcelain stopper but with brackets and 32 mm bore brass waste fittings chromium plated including cutting for and pinning in ends of brackets complete all as specified and directed. |
| 90 | Supply, hoist and fix 500 litre capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of old unseviciable existing tank and removing from site complete all as specified and directed. |
| 91 | Supply and fix in repair 20mm dia ball valvehigh pressure high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gm) complete all as specified and directed. |
| 92 | Supply and fix in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 93 | Supply and fix in repair 40mm bore high density polyethylene pipes (HDPE) with all fittings of pressure rating 6 kgf/cm2 fixed to walls, ceilings or in floors etc. complete all as specified and directed. |
| 94 | Supply and fix in repair 25 mm dia aluminium anodised decorative/fancy type drapery rodwith bracket complete all as specified and directed. |
| 95 | Supply and fix in repair looking mirror ofsize 600mm x 450mm x 5mm thick bevelled edge of selected quality glass, decorative type mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers completeall as specified and directed. |
| 96 | Dismantling of 110/100/75mm dia PVC/ cast iron or reinforced concrete drain pipes with all fittings, jointed in cement mortar and taking out of trenches/ from wall, if required complete all as specified and directed. |
| 97 | Supply and fix solid PVC door frame of size 50x47 mm made out of 5mm PVC sheet plain colour reinforced with MS square tube as per specification and drawinggiven in SSR Part-II 2020 complete all as specified and directed. |
| 98 | Supply and fix factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement as per specification and drawinggiven in SSR Part-II 2020 complete all as specified and directed. |
| 99 | Supply and fix factory made PVC wire gauzed door shutters 30mmm thick (style) consisting of frame made of MS tube for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC `C\" channel having a PVC sheet strip of 20 mm width Stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail.Panelling of wire gauzed shutter, the wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly and jointed together with solvent cement as per specification and drawing given on MES schedule Part – II (2020) complete all as specified and directed. |
| 100 | Material and labour for welding in repairs n. exc 2.5cm in length, thickness of metal to be welded exc 6mm but n. exc 9mm complete all as specified and directed. |
| 101 | Supply and fix 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls including stack clamp of suitable size complete all as specified and directed. |
| 102 | Supply and fix 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 103 | Fixing only in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls including stack clamp of suitable size complete all as specified and directed. |
| 104 | Supply and fix 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls including stack clamp of suitable size complete all as specified and directed. |
| 105 | Supply and fix 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 106 | Supply and fix 110mm bore PVC (SWR) juction single (singleT) equal or unequal with access door complete all as speified and directed |
| 107 | Supply and fix 110 mm bore PVC (SWR) bends with access door any radius complete all as speified and directed. |
| 108 | Supply and fix 75mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 109 | Supply and fix 75mm bore PVC (SWR) juction single (singleT) equal or unequal complete all as speified and directed |
| 110 | Supply and fix in repair 75 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 111 | Supply and fix 125 / 110 mm size PVC (SWR) gully trap, setting and jointing with solvent cement complete all as specified and directed. |
| 112 | Supply and fix in repair 32mm bore PVC corrugated waste pipe 800mm long complete all as specified and directed. |
| 113 | Supply and fix in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 114 | Supply and fix in repair towel ring of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 90gms) complete all as specified and directed. |
| 115 | Supply and fix in repair door stopper 150mm long cover plate, aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed to shutter complete all as specified and directed. |
| 116 | Supply and fix in repair 5mm thick glass corner shelf of size 300 x 300mm with stainless steel railing fixed with chromium plated screws complete all as specified and directed. |
| 117 | Supply and fix in repair stainless steel plate rack 0.85 mm thick of size 786x914x254mm of steel grade-204 complete all as specified and directed. |
| 118 | Supply and fix solid PVC wall lining consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC/Aluminium frame complete all as specified and directed. |
| 119 | Supply and fix in repair soap dish, brass, chromium plated complete all as specified and directed. |
| 120 | Material and labour for hardcore of broken stone or boulder of gauge n.exc 63mm, deposited, spread and leveled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 121 | Material and labour for 75mm thick PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in plinth protection, laid in panels including finishing the concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 122 | Material and labour for forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’,thickness of concrete slab in 75mm complete all as specified and directed. |
| 123 | Supply and fix in repair gun-metal globe or gate valves 20 mm dia with iron wheel head screwed both ends for iron pipe complete all as specified and directed. |
| 124 | Material and labour 75mm thick PCC (1:3:6), type C-2 (using 40 mm graded stone aggregate) as in sub-basecomplete all as specified and directed. |
| 125 | Material and labour forjoint free anti skid outdoor pavement coloured tiles (good grip series) of size 300 x 300 x 10mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 20mm thick screed bed in cement mortar (1:6) complete all as specified and directed. |
| 126 | Material and labour for cutting holes into or through brick wall built in cementmortar of superficial area not exc 150 sqcm and making good in CM (1:3) or cement concrete (1:2:4) type B-1 as required complete all as specified and directed. |
| 127 | Material and labour for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces complete all as specified and directed. |
| 128 | Material and labour for preparation of newly bitumen surfaces and applying two coats of bituminous aluminium paint @ 0.10 ltrs per sqm per coat complete all as specified and directed. |
| 129 | Complete removal of existing roof treatment in any layers and disposal of debris from site complete all as specified and directed.Notes: - (a) The rates are inclusive of removal for any type of old water proofing treatement over main RCC slab.(b) Bidders are advised to visit the site and esure about site condition before quoting their rates.(c) Demolition of PCC/ taking down plaster if any shall be measured and paid saparately under respective items. |
| 130 | Material and labourfor 15mm thick rendering in cement mortar (1:4) with using water proofing coumpound (WPC) @ 200 ml per bag of cement (50 kg) or as per manufacturers instruction on roof top and finish the surfaceseven and smooth without using extra cement including taking down existing cement plaster and disposal of debris from site complete all as specified and directed.Note : WPC will be measured and paid separately under respective item. |
| 131 | Supply only liquid water proofing compound (WPC) completeall as specified and directed. |
| 132 | Material and labour for 25mm thick PCC (1:2:4) type B-0 (using 12.50mmgraded stone aggregate) in roof top surfaces complete all as specified and directed. |
| 133 | Material and labourfor 5mm thick rendering in cement mortar (1:3) with using water proofing coumpound (WPC) @ 200 ml per bag of cement (50 Kg) or as per manufacturers instruction on roof top while concrete is green to become integrated part of concrete padding layer and finish the surfaceseven and smooth without using extra cement complete all as specified and directed.Note : WPC will be measured and paid separately under respective item. |
| 134 | Material and labour for water proofing treatment to RCC roof surface comprising with the following course of treatment/specifications from bottom to top :- (a) Applying cold bituminous primer @ 0.30 liters per sqm confirming to IS 3384 over plastered surfaces of roof.(b) One layer of APP based polymeric membrane3mm thick, weight not less than 3.50 kgs per sqm, reinforced with non woven polyester matt central core fabric (weight not less than 160 GSM) and coated on both side with and including layer of APP modified bitumen and finished with and including micro-prefabricated heat fusible polythene film on both surfaces. (c) Finally applying two coats of bituminous aluminum paint @ 0.10 ltrs per sqm per coat on top surface.Note:-(i) Laying of APP based polymeric membrane shall be done by torch on method or as per manufacturers instructions. (ii) A minimum overlap of 150mm and 100mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instructions.(iii) The work shall be executed only through authorised applicator of manufacturer as approved by GE. Make of APP membrane:- Super Thermolay of M/s STP Ltd, Hyperplas of M/s IWL India Ltd, Hydrostop of M/s Tiki Tar Danosa (India) pvt ltd, , M/s FOSROC Chemicals, Smartcare APP membranes of M/s Asian Paints Ltd. |
| 135 | Material and labour for cutting out cracks to V-section in existing roof or terracing, cleaning and filling solidly with hot mixture of bitumen and clean dry sand (1:1) (by weight) complete all as specified and directed. |
| 136 | Material and labour for mild steel round bars 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips conforming to Fe-410-W (Gde-E quality-A) or Fe-290 (Gde-E 165)complete all as specified and directed. |
| 137 | Supply and fix wire netting of galvanised steel wire 0.71mm dia and 20mm mesh size fixed with tinned tacks of wire staples complete all as specified and directed. |
| 138 | Material and labour for providing, cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) in roof kerbs ormud stops, rounded or chamfered on edges complete all as specified and directed. |
| 139 | Material and labour for post constructional anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.Note :The work shall be executed only through authorised applicator as approved by GE. |
| 140 | Material and labour for post constructional anti-termite treatment for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed..Note :The work shall be executed only through authorised applicator as approved by GE. |
| 141 | Supply and fix rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of Fe 410 -W (Gde-E- 250) quality-A including one shop coat of red oxide zinc chrome primer complete all as specified and directed. |
| 142 | Supply and fix 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified anddirected. |
| 143 | Supply and fix in repair 32mm dia bottle trap of PTMT having minimum water seal of 25mm (minimum weight 260 gms) complete all as specified anddirected. |
| 144 | Material and labour for structural steel work in plates/ Base plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk)forming holes,without anyattachment conforming to Fe-410-W (Gde-E-250 quality-A) complete all as specified and directed. |
| 145 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. .complete all as specified and directed. |
| 146 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store for keeping in safe custody for reuse complete all as specified and directed. |
| 147 | Material and labour for light/fan point wiring (concealed type) with single core PVCinsulated unsheathedmultistranded FRLSH copper conductor cable of 1100 volts grade size 1.5 sqmm (nominal area) in and including heavy duty rigid non metalic 20mm dia PVC conduit with accessories including with 1.2mm thick pressed steel terminal boxes in flush to existing wall surface with 3mm thick bakelite sheet top cover (ISI marked) fixed with chromium plated brass screws and cap washers suitable for housingswitches, sockets and regulatorswith all fittings and fixing materials with one single core PVC insulated unsheathed 1.5 sqmm (nominal area) multistranded FRLSH copper conductor as earth continuity wire and connected to earth dully complete all as specified and directed.Note: (a) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.(b) Quoted rate shall be included for cuttings /chasing the wall and making good disturbed surfaces to fix PVC conduit and MS terminal box. |
| 148 | All as per item No. 146.00 here-in-before but for bell/buzzer point controlled by one push button on independent board and -ditto-. |
| 149 | All as per item No. 146.00 here-in-before but for one five pins 5 Amps switch socket outlet point on independent board and -ditto-. |
| 150 | All as per item No. 146.00 here-in-before but for one five pins 5 Ampssocket outlet point on same board and -ditto-. |
| 151 | All as per item No. 146.00 here-in-before but for 15 amps socket outlet on independent board with 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade including 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade as earth continuity conductor and connecting to common earth dollyand -ditto-. |
| 152 | All as per item No. 146.00 here-in-before but for one light point controlled by two 2-way switches of 5 amps and -ditto-. |
| 153 | Supply and fix switch piano one way 5/6 amps240 volts, single polecomplete allas specified and directed. |
| 154 | Supply and fix switch piano two way flush type 5 amps complete allas specified and directed. |
| 155 | Supply and fix bell push AC, 50 Hz, 230 Volts, 5 amps complete allas specified and directed. |
| 156 | Supply and fix bell ding dong AC, 230 Volts, single pole complete allas specified and directed. |
| 157 | Supply and fix delux steppedtype electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed. |
| 158 | Supply and fix switch socket combination 2 in 1,5 pin , 5 amps flush type complete allas specified and directed. |
| 159 | Supply and fix socket outlet2 in 1, 3 pin 5 Amp flush type complete allas specified anddirected. |
| 160 | Supply and fix switch socket combination 5 in 1,5/15 amps socket complete allas specified anddirected. |
| 161 | Supply and fix ceiling rose, 3 terminals, fabricated of PVC/Polycarbonate, isolated body complete all as specified and directed. |
| 162 | Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed. |
| 163 | Supply and fix in repair LED tube light fitting 1 x 20W (+/- 5%), 220V, AC with extruded strip in thermally conductive material & extruded housing in optically efficient material milky white with system lumen efficacy > 120 lumen per watt minimum system 2300 - 2400 and chip, Integrated electronic driver, SMD based LED constant current supply with double sided connection to avoid short circuit and surge protection greater than 2.5 KV, IP 20 protection and CRI>80, Power factor > 0.95, THD less than 15%, correlated Colour temperature (CCT) of 6500K, Operating Voltage of 140 V to 270 V, frequency of 50Hz burning hours 50000 hours with comprises of CRCA pre coated metal housing complete all as specified and directed. |
| 164 | Supply and fix in repair LED tube light fitting 1 x 10W (+/- 5%), 220V, AC with extruded strip in thermally conductive material & extruded housing in optically efficient material milky white with system lumen efficacy > 120 lumen per watt minimum system 2300 - 2400 and chip, Integrated electronic driver, SMD based LED constant current supply with double sided connection to avoid short circuit and surge protection greater than 2.5 KV, IP 20 protection and CRI>80, Power factor > 0.95, THD less than 15%, correlated Colour temperature (CCT) of 6500K, Operating Voltage of 140 V to 270 V, frequency of 50Hz burning hours 50000 hours with comprises of CRCA pre coated metal housing complete all as specified and directed |
| 165 | Fixing only LED tube light fitting of any watt with bracket with necessary electrical connection 1.5 sqmm 2 core copper condutor wire complete all as specified and directedNote:- Item obtained from item No 144.00 shall be reused under this items. |
| 166 | Taking down and refixing exisiting exhaust fan with replacement of new GI sheet louvers and properly fixed to the opening including wire mesh and necessary electrical connection complete all as specified and directed |
| 167 | Taking down electric meter from inside room and refixing the meter with necessary electrical connection near main DB under stair case in proper mannar including Supply and fix PVC enclosure box made out of thermoplastic sheet having IP-66 protection of size 400mm x 300mm x 190mm in front openable type with fixing nut & bolt clamps including writing of Qtr Number on meter Box by paintcomplete all as spcified and directed. |
| 168 | Materials and labour for complete removal of existing treatment of old steel surfaces of LT panel board / feeder pillar box and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer including preperation of surface complete all as specified and directed. |
| 169 | Supply and fix 300mm sweep steel body exhaust fan AC single phase 230/240 volt. 1400 RPM, heavy duty, ISI marked, along with metal blade powder coated metalic finish with GI sheet louvers, low noise including necessary electric connection with and including cutting/making opening having dia of the hole for 300mm sweep exhaust fan inany type of walls of any description with nut, bolt, washer and making good distrubed surfaces complete all as specified and directed. |
| 170 | Supply and fix in repair sheet metal enclosureSPN DB 8 waysdouble door having facility to fix MCB in incomer and MCBs in outgoing,metal door IP-43type complete fitted with bus bars, neutral links, blanking plates complete all as specified and directed. |
| 171 | Supply and fix in repair MCB SPN, 240 Volts, 40amps, \"C\" series, breaking capacity 10 KA complete all as specified and directed. |
| 172 | Supply and fix in repair MCB SP, 240 Volts, of 6 to 32 amps current rating, 10 KA breaking capacity \"C\" series complete all as specified and directed. |
| 173 | Material and labour forconcealed submain wiring comprising single core , 2 Runs of 6 sqmm nominal cross sectional area, FR-LSHmultistrandedcopper conductor cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including appropriate dia. in PVC conduit and its fittings complete including provision of 1x6 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earthwirecomplete including taking down old unserviceable sub main wiring complete allas specified anddirected.Note :-(a) Cost for extra length of cables / wire required for connection to MCBs/DB\"s shall be included in quoted rates.(b). Cost for cuttings /chasing of wall etc and making good the disturbed surface shall be included in quoted rates. |
| 174 | Supply and fix in repair LED street light fitting 35 Watt, 230 volts made with pressure die cast housing with toughened glass with high powered LED, IP-66 protection high power LED with secondary lenses and system efficiency should be minimum 110 lumen per watt. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device, THD shall be <10%, power factor >.95, CCT 5700K and brand name should embossed/engraved on the LED fitting for traceability till life complete all as specified and directed. |
| 175 | Material and labour for street light bracket made of 1.5 meter long GI pipe of light grade of 40 mm dia in proper shaped, bend, threadedand drilling holes for wire entry and MS clamps of flat iron of size 40x5mm of suitable length in 2 pairs incl nut bolts etc of suitable size including taking down old unserviciable street light bracket cmplete all as specified and directed. |
| 176 | Supply, install , testing & commissioning 3 phase neutral, 415 volts indoor type, wall mounted panel of size 1100 mm x 1100 mm x 250mm (CPRI approved)weather proof, made out of 2.00 mm thick CRCA sheet, detachable gland plate at top/bottom of 2mm thick CRCA sheet, with anticorresive coating and finally epoxy polyester powder coating with pure polyster simens grey structural RAL-7032 shade andduly grouted in wall with the help of cement screw/nuts & Bolts protection class IP66 fully compartmentalize design with 04 Nos of busbar made of copper ETP grade suitable for 300 Amp (size of copper strip should not be less than 25 x 6 mm for each phase and neutral) pre-wired with suitable size of copper strip / copper wire with colour code for connecting out going MCCB/ MCB\"s, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring after taking down old unserviceable indoor panel of any size. The Indoor panel shall be fixed with following accessories :- (A) Incoming: - (a) MCCB 200 Amp rating , 4 Pole , 415V, AC, 50 HZ, thermal release range amp with adjustable overload setting and short circuit setting, Ics-100% Icu, service breaking capacity 25 KA - 01 No. |
| 177 | (B) Outgoing: -(a) MCB DP 40 to 63 Amp, breaking capacity of 10 KA - 20 Nos.(b) Digital Voltmeter 0-500 V with selector switch - 01 No. (c) Digital Amp meter 0-100A with set of current transformer of suitable rating and selector switch - 01 No.(d) Indicator lamp (RYB) LED type - 01 set.(e) Current transformer 200/5 Amp - 03 Nos. (f) MCB, SP, 6 to 32 Amp, 10KA for protection and controlling - 03 Nos. Note :- (i) Drawing of LT Panel and make of items shall get approved from GE before ordering the panel. (ii) Cost of lugs for cable and cable gland etc also included in the quoted rate. (iii) Rotary handle to be provided for all MCCB for control and operation of MCCB without any extra cost.(iv) The rating of copper bus bar to outgoing MCCB /MCBs shall not less than 1.5 times the rated current of indiviual outgoing feeders / MCCB. (v) Spreader terminals and phase barriers to be provided with all MCCBs.(vi) Rate of panel include refixing of all cables in panel which shall be dismantled & taking out from old unserviceable panel. |
| 178 | Material and labour for earthing complete with copper earthplate electrode of size 600 x 600 x 3.15mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 20 x 3mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of galvanised iron steel,protected by 40 mm bore HDPE pipe of pressure rating 6 kgf/sqcm allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x 6cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 15 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion including taking down old existing unserviciable earthing complete all as specified and directed.Note:- Strip upto 7.5m length including testing shall be included in quoted rates. |
| 179 | Material and labour for earth continuity conductor or main earthing lead with copper strip 25 x 3.15mm , fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or DB\"s / Indoor type LT PBs orany other indicated situation for loop earthing etc including taking down existing earthing strip complete all as specified and directed |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy