Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Note : 1. Contractor need to purchase minimum 50% of all items mentioned in this CA within 20 days of getting sample approval and kept in custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of item/date.2. Contractor should buy the exact items which are given with catalogue reference. Other makes will be approved only by submitting non availability Certificate Company. Contractor need to remove all the dismantled items without delay.3. Rate quoted for demolition/dismantling /taking down is inclusive of removing the same from site and dumping at given locations anywhere inside station.4. Contractor will make his own arrangement to store his items.5. Some places in this contract where the vehicle will not reach the spot directly, the material will be moved manually in these places. The rate quoted will be considered all inclusive on this account.6. All trade skilled labour required in this contract shall be present daily in working hours, irrespective of complaints received.7. Complaint for a similar items may be in scattered / different area, quoted rate will be considered all inclusive on this account. |
| 2 | S & Fin replacement 4ft 20W LED batten tubelightsurface/wall mounted with powder coated Aluminium housing, high optically efficient polycarbonate diffuser, inbuilt electronic driver duly wired upto terminal block, luminous efficiency > 100 lm/watt, surge protection upto 4kV, 440V High voltage protection, power factor > 0.95, CRI > 80 all as specifiedanddirected by the Engineer-in-charge. Model: Wipro Garnet/ Crompton Linea Pro/ Havells Endura Linear Pro / similar |
| 3 | Supply and fixingin replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 240 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete, all as specified and directed by the Engineer-in-charge |
| 4 | S&Fin replacement LED light fitting in replacement of 10 watt bulk head luminaries complete with all accessories and including connecting up with three core twisted flexible copper conductor cable of suitablesize complete all as specified and as directed by the Engineer-in-charge |
| 5 | Supply and fixing in replacement round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers as per sample, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size completeall as specified and as directed by the Engineer-in-charge. Model: Philips Ultra Slim Plus/ Havells Integra NXT/ Wipro garnet/Similar |
| 6 | Supply and fixing in replacement round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers as per sample, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-charge. Model: Philips Ultra Slim Plus/ Havells Integra NXT/ Wipro garnet/Similar |
| 7 | Supply and fixing in replacement Deep recessed downlights, 18Watt, aluminium construction EMC/EMI compliant, Ripple<5% flicker free driver, as per sample provided including connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light to roof surface all as specified and as directed by the Engineer-in-charge.Model: Philips Ultra Slim Plus/ Havells Vibe G2/ Wipro garnet/Similar |
| 8 | Supply and fixing in replacement round shape 20 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers,as per sample provided, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-charge.Model:Wipro garnet/ Crompton Star Lord/ Similar |
| 9 | Supply and fixing in replacement round shape 24 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,as per sample provided, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-charge.Model: Havells Integra NXT/ Jaquar areva prime/Similar |
| 10 | Supply and fixingin replacement surface downlights, 18Watt, aluminium housing with heat sinkas per sample provided including connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light to roof surface all as specifiedanddirected. Model: Havells Integra NXT |
| 11 | Supply & fixing in replacement ofhigh efficacy recess luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free lightand good aesthetic appeal 35/36 W LED (2ft X 2ft) complete with all accessoriesincluding connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. Model: Havells Venus Neo/Crompton super lumen tile / similar |
| 12 | Supply and fixing of surface ceiling light 24watt,dimensions 250mm x 65mm x 250mm ( L x H x W) complete all as specified and directed by the Engineer-in-charge. Model No. Philips Saturn / Crompton star stylus/ similar |
| 13 | S&F in replacement busbar plug-in box 16A, 3phase complete . Make: Legrand Cat No. 75005005 or equivalent approved make for effective working oflights/fans all as specified and directed by the Engineer-in-charge |
| 14 | S & F in replacement of louvers with suitable frame work and fixing arrangements forexhaust fan of any size sweep complete including removing the existing unserviceable one all as specified and directed by the Engineer-in-Charge. |
| 15 | Supply and fixing of fan wall mount brackets, set of 2Pcs, MS material suitable for wall fan of any type complete all as specified and directed by the Engineer-in-charge |
| 16 | Supply and laying PVC wire trunking, self-extinguishing type 100x50 mm, sheet thickness minimum 4mm including coupler plates, elbows, tees, reducers, bolts, nuts, washers and other accessories conforming to NEMA/ASTM/BIS standards complete all as specified and directed by the Engineer in charge |
| 17 | Supply and laying PVC wire trunking, self-extinguishing type 150x50 mm, sheet thickness minimum 4mm including coupler plates, elbows, tees, reducers, bolts, nuts, washers and other accessories conforming to NEMA/ASTM/BIS standards complete all as specified and directed by the Engineer in charge |
| 18 | Supply and laying PVC wire trunking, self-extinguishing type 100x100 mm, sheet thickness minimum 4mm including coupler plates, elbows, tees, reducers, bolts, nuts, washers and other accessories conforming to NEMA/ASTM/BIS standards complete all as specified and directed by the Engineer in charge |
| 19 | Supply and fixing in replacement LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection with suitable no of nuts, bolts and clamps complete all as specified and directed by Engr-in-charge |
| 20 | Material and labour for fixing of building security light bracket made out of 40mm dia medium grade GI pipe 1.5mtr long bent to required shape to illumimate the area complete all as specified and directed by the Engineer-in-charge |
| 21 | Supply and fixing of ceiling fan white canopy/fan cover suitable for all fan types, plastic, downrod mount complete all as specified and directed by the Engineer-in-charge |
| 22 | Supply and Fixin replacement offollowing items all as specified and directed by Engineer-in-Charge:- |
| 23 | a) LED driver suitable for 2x2 LED Panel of any company from 36 watt to 42 watt Make Havells/Philips/CG |
| 24 | b) LED driver suitable for LED Lights of any company from 60 watt to 100 watt Make Havells/Philips/CG |
| 25 | S & F in replacement earth plug and socket with enclosure, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 voltswith and including one MCB, SP, 20A, 240 Volts as per all as specified and directed. |
| 26 | S&F surface plastic boxes made of high impact plastics and metal thread inserts 3Module complete on any surface all as specified and directed by the Engineer-in-charge |
| 27 | All as per item No. 23 here-in-before but with 4 Module complete |
| 28 | All as per item No. 23 here-in-before but with 6 Module complete |
| 29 | All as per item No. 23 here-in-before but with 8 Module complete |
| 30 | All as per item No. 23 here-in-before but with 12 Module complete |
| 31 | S&F modular metal flush box 3 module complete including any civil work required to make good the disturbed surface all as specified and directed by Engr-in-charge. |
| 32 | S&F modular metal flush box 4 module complete including any civil work required to make good the disturbed surface all as specified and directed by Engr-in-charge. |
| 33 | S&F modular metal flush box 6 module complete including any civil work required to make good the disturbed surface all as specified and directed by Engr-in-charge. |
| 34 | S&F modular metal flush box 8 module complete including any civil work required to make good the disturbed surface all as specified and directed by Engr-in-charge. |
| 35 | S&F modular metal flush box 12 module complete including any civil work required to make good the disturbed surface all as specified and directed by Engr-in-charge. |
| 36 | S&F in replacement of modular cover plate white with frame complete for3 module complete all as specified and directed by Engr-in-charge. |
| 37 | S&F in replacement of modular cover plate white with frame complete for4 module complete all as specified and directed by Engr-in-charge. |
| 38 | S&F in replacement of modular cover plate white with frame complete for6 module complete all as specified and directed by Engr-in-charge. |
| 39 | S&F in replacement of modular cover plate white with frame complete for8module complete all as specified and directed by Engr-in-charge. |
| 40 | S&F in replacement of modular cover plate white with frame complete for12module complete all as specified and directed by Engr-in-charge. |
| 41 | Supply and fixing electrical panel hylam sheets 3mm thick including cutting for mounting of switches / sockets /of size required as per site requirementcomplete all as specified and directed. |
| 42 | S&F in replacement of switch piano flush type, single pole one way6 Amps 240 volts ISI marked complete all as specified and as directed. |
| 43 | S&F in replacement of bell push,flush type, 6 Amps ,240 Volts ISI marked complete. |
| 44 | S&Fin replacement of switch socket combination 2 in 1,3 pin 6 Amps, flush type, universal ,240 volts completeall as specified and as directed |
| 45 | M & L in replacement of switch socket combination 2 in 1, 3 pin , 6 Amps/16 Amps, flush type,universal,240 volts completeall as specified and as directed |
| 46 | M & L in replacement ofCall bell, ding dong, AC 240 Volts completeall as specified and as directed |
| 47 | S&F in replacement of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz2 module size in 5 stepsflush type complete all as specified and directed. |
| 48 | S&F in replacement ofstepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hzsinglemodule size in 5 stepsflush type complete all as specified and directed. |
| 49 | S&F BLDC Fan regulator, 12 step control, 2M, High-grade, UV-stabilized polycarbonate material, compatible for all BLDC Fans complete all as specified and directed. |
| 50 | S&F of PCB controlller for BLDC ceiling fan of any type & make, stator with winding and shaft complete all as specified and directed. Note: Make shall be same as the make of fan under repair |
| 51 | S&F in replacement of switch Modular type single pole one way6 Amps 240 volts complete all as specified and as directed. |
| 52 | S&F in replacement of switch Modular type single pole one way16 Amps 240 volts complete all as specified and as directed. |
| 53 | S&F in replacement of bell push,modular type, 6 Amps ,240 Volts ISI marked complete. |
| 54 | S&Fin replacement ofsocket2 in 1,3 pin 6 Amps, modular type, universal ,240 volts completeall as specified and as directed |
| 55 | S&Fin replacement of socket 2 in 1,3 pin 16 Amps, modular type, universal ,240 volts completeall as specified and as directed |
| 56 | S&F in replacement ofstepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz2 module size in 5 stepsmodular type complete all as specified and directed. |
| 57 | S & F in replacement of batten/angle holder, PVC/Polycarbonate type with back plate, 240 V , 50 Hzsuitable for batten fittings complete all as specified and directed. |
| 58 | S&F in replacement of ceiling rose 6 A, 3 plate,PVC/polycarbonate ,insulated body 240 Volt , 50 Hz all as specified and as directed. |
| 59 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fittings etc removing materials and making good disturbed surfaces of walls, floors etc. including paint touch up to match with the existing surface as per site requirement complete all as specified and directed by Engr-in-Charge. |
| 60 | Taking down existing unserviceable MCCB/main switch (any type and capacity) and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge. |
| 61 | Taking down existing unserviceable distribution board with MCBs, switch fuse unit, enclosure and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge. |
| 62 | Taking down Existing old unserviceable submain wiring of any description /type size and removal of UNSV material from site and making good the disturbed surface of walls / ceiling so asto match with the existing finishes all as specified and as directed by the Engineer -in- charge . |
| 63 | M&L for point wiring with 1.5 Sqmm (nominal area) multi stranded copper conductor, single core, FR-LSH PVC insulated & unsheathed cable in accordance with relevant IS with proper colour coding, 1100 volts grade drawn in ISI marked MMS grade PVC conduit of dia 20mm minimum/ casing capping , 1.2 mm thick minimum, 20mm width minimum with double locking arrangement, surface type terminated in sunken type GI sheet metal flush boxes of 16 Gauge (i.e. 1.6mm thickness) including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FR-LSH PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- NOTE FOR ITEM NO. 60,61,62, 73 TO 77 :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxesto required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. If the building is stone masonry, diamond tools must be used to cut the surfaces.(ii) The decision of casing capping/PVC conduit rests with the Engineer-in-charge.For casing capping, screws of minimum 35x8mm and suitable plugs should be used for fixing. In case of stone walls, wooden gutties shall be grouted in wall for fixing of screws. Distance between 2 screws shall not be more than 600mm. Size of Trunking shall be correct depending on number of wires to be drawn as per SSR Part1 but not less than 20mm.(ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A\".(iii) The quoted rates shall be deemed to be inclusive for provision and installation of conduits, covering sunken boards/terminal boxes / junction boxes of any shape and size modular white colour cover plate with frame and modular metal flush box. All metal boxes and plates to be of the same make as the switches mentioned in this schedule. |
| 64 | a)One light point controlled by one, 1 way switch |
| 65 | b)One 3 pin 6 Amps socket point controlled by one switch on same board |
| 66 | c)One 3 pin 6 Amps socket point controlled by one switch on independent board |
| 67 | d)One ceiling fan/exhaust fan point controlled by one 1way switch |
| 68 | e)One bell point controlled by one switch |
| 69 | f)One light point controlled by two, 2 way switches |
| 70 | All as per item No. 60 here-in-before but with 2.5 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. |
| 71 | All as per item No. 60 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. |
| 72 | M&L for point wiring with 1.5 Sqmm (nominal area) multi stranded copper conductor, single core, FR-LSH PVC insulated & unsheathed cable with proper colour coding, 1100 volts grade drawn in ISI marked MMS non-metallic PVC conduit of size not less than 20mm dia conforming to IS 9537:latest, concealed type terminated in sunken type GI sheet metal flush boxes of 16 Gauge including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FR-LSH PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- NOTE FOR ITEM NO. 63,64,65,71,72 :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes and PVC conduits to required depth & making good the disturbed surface in CM 1:4 including core cutting whwrever required and finishing the surface to match with the existing surface. If the building is stone masonry, diamond tools must be used to cut the surfaces.(ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A\".(iii) The quoted rates shall be deemed to be inclusive for provision and installation of conduits, covering sunken boards/terminal boxes / junction boxes of any shape and size modular white colour cover plate with frame and modular metal flush box. All metal boxes and plates to be of the same make as the switches mentioned in this schedule. |
| 73 | a)One light point controlled by one, 1 way switch |
| 74 | b)One 3 pin 6 Amps socket point controlled by one switch on same board |
| 75 | c)One 3 pin 6 Amps socket point controlled by one switch on independent board |
| 76 | d)One ceiling fan/exhaust fan point controlled by one 1way switch |
| 77 | e)One bell point controlled by one switch |
| 78 | f)One light point controlled by two, 2 way switches |
| 79 | All as per item No. 63 here-in-before but with 2.5 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. |
| 80 | All as per item No. 63 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. |
| 81 | M&L in replacement for point wiring with 1.5 sq.mm FRLSH insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through existing steel/PVC conduit upto 32mm including FRLSH, PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour codingand pressed steel terminal boxes made out of 1.6 mm thick MS sheet box with 3mm thick laminated hylam sheet fixed with cadmium plated screws for mounting switches, sockets, fan regulator, etcincluding all accesories if required making good the disturbed surfacesof walls and paint tuch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge. |
| 82 | a)One light point controlled by one switch |
| 83 | b)One 3 pin 6 Amps socket point controlled by one switch on same board |
| 84 | c)One 3 pin 6 Amps socket point controlled by one switch on independent board |
| 85 | d)One ceiling fan point controlled by one switch and regulator |
| 86 | All as per item No. 66 here-in-before but with 2.5 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. |
| 87 | All as per item No. 66 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. |
| 88 | M&L for submain wiring along with earth wire with 3 x 4.0 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through existing recessed/surface steel/PVC Conduit/ casing capping in wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note: Three runs of 4.0 Sqmm copper cable shall be measured as one unit length. |
| 89 | All as per item No.69 here-in-before but with 3 x 6.0 sqmm FRLSH PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge.Note: Three runs of 6.0 Sqmm copper cable shall be measured as one unit length. |
| 90 | M&L for submain wiring alongwith earth wire with 3 x 4.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit concealed and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note:Three runs of 4.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. |
| 91 | All as per item No. 71 here-in-before but with 3 x 6.0 sqmm FRLSH PVC insulated copper conductor cable concealed complete all as specified and directed by Engineer-in-Charge.Note: Three runs of 6.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. |
| 92 | M&L for submain wiring alongwith earth wire with 3 x 6.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit/casing capping on surface and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note:Three runs of 6.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. |
| 93 | M&L for submain wiring alongwith earth wire with 3 x 10.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit/casing capping on surface and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note:Three runs of 10.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. |
| 94 | M&L for submain wiring alongwith earth wire with 5 x 4.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit/casing capping on surface and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note:Five runs of 4.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. |
| 95 | M&L for submain wiring alongwith earth wire with 5 x 6.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit/casing capping on surface and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note:Five runs of 6.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. |
| 96 | M&L for submain wiring alongwith earth wire with 5 x 10.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit/casing capping on surface and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge.Note:Five runs of 10.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. |
| 97 | Supply and fixing/laying2 core 2.5sqmm copper flexible cable, PVC insulated and sheathed, on wall, roof, ground, pole or passing through nallah, under road including fixing to any surface with proper plugging arrangement or in ground/wall complete all as specified and directed by the Engineer in charge |
| 98 | Supply and laying 3 core 2.5sqmm copper flexible cable, PVC insulated and sheathed, on wall, roof, ground, pole or passing through nallah, under road including fixing to any surface with proper plugging arrangement or in ground/wall complete all as specified and directed by the Engineer in charge |
| 99 | Supply and laying 2 core 4sqmm copper flexible cable, PVC insulated and sheathed, on wall, roof, ground, pole or passing through nallah, under road including fixing to any surface with proper plugging arrangement or in ground/wall complete all as specified and directed by the Engineer in charge |
| 100 | Supply and laying 3 core 4sqmm copper flexible cable, PVC insulated and sheathed, on wall, roof, ground, pole or passing through nallah, under road including fixing to any surface with proper plugging arrangement or in ground/wall complete all as specified and directed by the Engineer in charge |
| 101 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty 2 core cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm nominal cross section in service connections complete all as specified and directed by the Engineer in charge |
| 102 | Supply and fixing of electrical flexible conduit 25mm dia, dark grey/white, corrugated , including removing the existing electrical connection on either side of DBs/Switchboards/fixtures/fittings and reconnecting after running the electrical connecting wires in the conduit complete,all as specified and directed by Engineer-in-charge |
| 103 | Supply and laying Non-metallic PVC conduit MMS grade conforming to IS 9537:latest, FRLS, dia 20mm including all accessories and hardware complete all as specified and directed by the Engineer-in-charge.Note: Cost of cutting chases shall be measured and paid separately under relevant item of this schedule. |
| 104 | Supply, Install, testing & commissioning factory made CPRI approved Cubical thermoplastic polycarbonate LT panel shock, rust, dust, impact and water proof, halogen and silicon free, UV resistant with internally embedded high grade gasket made of polyurethane, IP-65 , panel of suitable size fully wired up, ready to connect load and control lines comprising the folowing complete all as specified and directed by the Engineer-in-charge:- |
| 105 | (i) incomingMCCB 100 Amp, 25 KA, 4 Pole thermal magnetic 415 Volt - 01 Nos, (ii) Outgoing MCB SPN 6-32 Amp, 10 KA 230V - 05 Nos (iii) Busbar chamber 150A 4tsrips Aluminium- 01 Set(iv) Panel should have provision and space to install five no of 1 phase electric energy meters.Electric wiring from outgoing MCBs to Electric meters to be provided with suitable size copper wire. Electric meters will be supplied by MES. Wiring from electric meter to main MCB DB will be measured separately(v) Digital Voltmeter 0-500V and inbuilt selector switch- 01No.(vi) Digital Ammeter 0-150A with inbuilt selector switch- 01No.(vii) Phase indicator neon lamps for R,Y,B -01 Set(viii) Protection MCB 6A SP- 03No.(ix) CT 150/5A-03No.(x) Danger plate- 01No.(x) Enclosure of suitable size- 01No. |
| 106 | Supply, Install, testing & commissioning factory made CPRI approved Cubical thermoplastic polycarbonate LT panel shock, rust, dust, impact and water proof, halogen and silicon free, UV resistant with internally embedded high grade gasket made of polyurethane, IP-65 , panel of suitable size fully wired up, ready to connect load and control lines comprising the folowing complete all as specified and directed by the Engineer-in-charge:- |
| 107 | (i) incomingMCCB 125 Amp, 25 KA, 4 Pole thermal magnetic 415 Volt - 01 Nos, (ii) Outgoing MCB SP 6-32 Amp, 10 KA 4 Pole 415 Volt - 14 Nos (iii) Busbar chamber 200A 4tsrips Aluminium- 01 Set(iv) Panel should have provision and space to install four no of 3 phase electric energy meters and 1no. 1phase energy meter. Electric wiring from outgoing MCBs to Electric meters to be provided with suitable size copper wire. Electric meters will be supplied by MES. Wiring from electric meter to main MCB DB will be measured separately(v) Digital Voltmeter 0-500V and inbuilt selector switch- 01No.(vi) Digital Ammeter 0-200A with inbuilt selector switch- 01No.(vii) Phase indicator neon lamps for R,Y,B -05 Sets(viii) Protection MCB 6A SP- 03No.(ix) CT 200/5A-03No.(x) Danger plate- 01No.(x) Enclosure of suitable size- 01No. |
| 108 | Supply and fixin replacement distribution board double door type TPN 8 waysheet steel powder coatedwith bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge. |
| 109 | All as per item No. 87 above but of TPN 4 way. |
| 110 | Supply and fix in replacement distribution board double door type VTPN 8 waysheet steel powder coatedwith bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge. |
| 111 | Supply and fixin replacement distribution board double door type VTPN 4 waysheet steel powder coated with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge. |
| 112 | Supply and fix MCB distribution board single door type SPN 12 way sheet steel powder coated with bus bar ,neutral link & earth bar etc.with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing circuit complete all as specified and directed by Engineer-in-Charge. |
| 113 | All as per item No. 91 above but of SPN 8 way. |
| 114 | All as per item No. 91 above but of SPN 4 way. |
| 115 | Supply and fixin replacement sheet metal powder coated double pole enclosure with a two pin and earth plug and socket flushing in wall including 20 Amps rated double pole MCB 10 KA, \"C\" curve complete all as specified and directed by Engineer-in-Charge. |
| 116 | Supply and fixin replacement sheet metal powder coated triple pole and neutral enclosure with a three pin and earth plug and socket flushing in wall including 32 Amps rated 415 V, three pole MCB 10 KA, \"C\" curve complete all as specified and directed by Engineer-in-Charge. |
| 117 | S&Fin replacement MCBTriple pole and Neutral (TPN) of capacity 40-100 Amps 415 volts ,breaking capacity 10 KA,\"C\" series ,fixed in proper position all as directed by the Engineer in charge . |
| 118 | Supply and fixin replacement MCB, SPN, 40-63 Amps, 240 Volts |
| 119 | Supply and fixin replacement MCB , SP, 6 - 32 Amps, 240Volts |
| 120 | Supply and fixingin replacement MCCB 125 Amp three pole 415 Volt , breaking capacity 16 KA, with fixed thermal & magnetic setting complete all as specified and as directed by the Engineer in charge. |
| 121 | Supply and fixingMCCB 25-100 Amp Three pole 415 Volt , breaking capacity, 16 KA, with fixed thermal & magnetic setting complete all as specified and as directed by the Engineer in charge. |
| 122 | Disconnecting and removing exhaust fan of any sweepany height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly and re-assembling in all respects after replacement of unserviceable parts/components provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan includingpainting of exhaust fan complete with synthetic enamel paint by spraying including filling cavities with filler , one coat after cleaning all dust etc & testing complete all as specified and as directed.Note: Note: Spare parts replaced shall be measured and paid seperately under relevant items.However, labour cost of replacement of parts is included in unit rate quoted |
| 123 | Disconnecting and removingceiling fan of any sweepany height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly, lubricating with approved lubricants, and re-assembling in all respects after replacement of unserviceable parts/components refixing in original position includingminor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan includingpainting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler , one coat after cleaning all dust etc & testing complete all as specified and as directed.Note: Spare parts replaced shall be measured and paid seperately under relevant items.However, labour cost of replacement of parts is included in unit rate quoted |
| 124 | Supply only the following parts in replacement of Ceiling/ Exhaust Fans of existing makes and size complete all as specified and as directed by the Engineer-in Chargre :- |
| 125 | (a)Capacitor 2.5 mfd capacity 240 volts. Make: CAPCO/TIBCON |
| 126 | (b)Ball bearingof suitable size. Make: NBC/SKF/TATA. |
| 127 | (c) Gun metal bush |
| 128 | (d) Copper flexible cord 3 core of size 23/00076, 5m bundle |
| 129 | (e) Fan Clamp with rubber bush |
| 130 | (f)Down rod, 400 mm long |
| 131 | (g) Capacitor 4 mfd capacity 240 volts .Make : CAPCO/TIBCON |
| 132 | (h) Ball bearing for exhaust fans of suitable sizeMake: NBC/SKF/TATA |
| 133 | S & F in replacement of motor for plastic exhaust fan of any size and type complete all as specified and directed by the Engineer-in-Charge. |
| 134 | Taking Down water heater (Electric Geyser) storage type of any make of 25 / 50 ltr capacity after disconnecting the existing electrical connection, water pipes and reassembling in all respects after replacing unserviceable parts/components and testing for proper working after repairs and refixing in the original place/position duly connecting up water supply and electric supply etc.complete all as specified and as directed by the Engineer-in-Charge. Note :- Spare parts replaced shall be measured and paid separately under relevent items below.However labour cost of replacement is deemed to be included in the rate quoted. |
| 135 | Supply only the following parts in replacement of water heater (Electric Geyser) storage type of given make and size complete all as specified and as directed by the Engineer-in Chargre :- |
| 136 | (a) Thermostat ISI marked suitable for 25/50 litre capacity . Make -sphare hot /bajaj/ditz/picco/usha /racold . |
| 137 | (b) Heating element ISI marked 2000 watt push/thread type circular /triangular base suitable for any make and size. Make - bajaj / Racold |
| 138 | (c) Indicator bulb 240 V suitable for givenmake, typeand model |
| 139 | S & F in replacement of PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides for cold water connection. |
| 140 | S & F in replacement of PVC connection 15 mm dia 900 mm long with PTMT nuts on both sides for cold water connection. |
| 141 | S & F in replacement of PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides forhotwater connection. |
| 142 | S & F in replacement of PVC connection 15 mm dia 900 mm long with PTMT nuts on both sides forhotwater connection. |
| 143 | Supply only Geyser Capillary Thermostat and Cut Out, Capillary Thermostat Suitable for any Geyser 10 to 50 Liter, 230volts, copper and plastic material complete all as specified and directed by the Engineer-in-charge |
| 144 | Supply and fixing of Round sheet 5\" , heavy duty PVC/ polypropylene complete all as specified and directed by Engineer-in-charge |
| 145 | Supply and fixing of Round sheet 6\" heavy duty PVC/ polypropylene all as specified and directed by Engineer-in-charge |
| 146 | S & F in replacement of plug top 3 pin 6 Amps 240 volts.Make: Anchor/Leader/Havells. |
| 147 | S & F in replacement of plug top 3 pin 16 Amps 240 volts.Make: Anchor/Leader/Havells. |
| 148 | Repairing/overhauling of TPN/SPN DBs of any size/type fixed on building wallincl cleaning with compressed air, tightening of all electric connection to the bus bar& switch gears , refixing of loosed doors withproper fixing & locking arrangement & necessary welding work as required and replacement of wornout/ burnt/rusted/ loose lugs , door lock, nut bolt,hing, washers,internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire ,repair to plaster workas require at site and including disconnection of all cable/ sub main from the bus bar and insulating the naked portion ofAl/Cu conductorand re-connect the sameafter repair of panel and proper connection of main earth wire/lead with panel body using lugs complete all as specified and directed. |
| 149 | Supply and fixing concealed meter box with isolator made from minimum 0.7mm thick CRCA sheet, to accommodate 1No. Single phase energy meter complete all as specified and directed. |
| 150 | Supply and fixing concealed meter box with isolator made from minimum 0.7mm thick CRCA sheet, to accommodate 1No. Three phase energy meter complete all as specified and directed. |
| 151 | Supply and fix electric water heater, vertical storage typewith ferroglass coated anti-rust inner container and heating element upto 2 KW capacity 25 litre, heavy duty anode rod, preset thermal cutout, BEE 5 Star rated as per latest BEE norms (i.e. standing losses ≤ 0.465 kWh/24 hour/45°C which is only valid till 31st Dec 2025, material shall be supplied as per latest revision at the time of supply, complete with all accessories such as safety valve, thermostat, NRV, connection piece(hot and cold water connection pipe)etc complete all as specified and directed by Engr-in-charge (as per latest authorization). Model: Havells Monza DX or similar in Bajaj/Orient |
| 152 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories without remote, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated as per latest BEE norms in vogue at the time of supply with brushless direct current motor (BLDC) including depositing the unserviceable ceiling fan to MES E/M store complete all as specified and directed by Engineer-in-Charge. |
| 153 | S&F in replacement post top lanterns, 25W , IP65 long life aesthetically designed with symmetrical light distribution with high power LED , clear/opaque cover as per site requirement complete all as specified and directed. |
| 154 | Supply and fix in replacement Exhaust fan, steel body AC Single phase 230 V of size 300 mm sweep with blades, and frame and louvers including taking down the existing unserviceablefan and depositing it to MES E/M Store complete all as specified and directed by Engr-in-charge |
| 155 | Supply and fix in replacement Exhaust fan, steel body AC Single phase 230 V of size 225 mm sweep with blades, and frame and louvers including taking down the existing unserviceablefan and depositing it to MES E/M Store complete all as specified and directed by Engr-in-charge |
| 156 | Supply and fix in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm including taking down the existing unserviceablefan and depositing it to MES E/M Store complete all as specified and directed |
| 157 | Supply & fixing in replacement new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED 8 Watts as light source with all accessoriesincluding connecting up with three core twisted flexible copper conductor cable with suitable size and fixing arrangements such as grouting with suitable nuts bolts and washers in PCC base complete all as specified and directed by Engineer-in-Charge. Make:- Havells Model No BAMBOOBLS8WLED830PSYMTOPC or equivelent in Bajaj/ Crompton/ Philips. |
| 158 | Suppy only Insulation tape all as specified and directed by Engineer-in-charge |
| 159 | S&F in replacement 400mm swing wall fan, 4star, smooth oscillation, copper motor with remote control, 72 speeds, plastic bodyincluding taking down the existing unserviceablefan and depositing it to MES E/M Store complete all as specified and directed |
| 160 | Supply and fix in replacement 12W LED T bulbs, cool day white, energy efficient, no visible flickering, glare reduction technology complete all as specified and directed |
| 161 | Supply and fxing of Cable Zip Ties Heavy Duty Strong Wire Organizer, nylon material, 8inch dia , 20cm length complete all as specified and directed by the Engineer-in-charge |
| 162 | Supply and fixing of blank plates, made of FR grade engineering plastic, for concealing vacant slots in switchboards complete all as specified and directed by the Engineer in charge |
| 163 | Supply and fixing of MCB modular blank plates, made of polycarbonate, glossy finish, rectangular type, thickness minimum 2mm complete all as specified and directed by the Engineer in charge |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail