| 1 | Excavationin trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation,laying of cable or pipe ( where provided for protection of cable or fixing with poles and stays) and getting out in any type of soilincluding trimming the sides and forming bottom surfaces to required levelscomplete all as specified and directed by Engr-in-Charge. |
| 2 | Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cmafter laying of cables including spreading, levelling, and well ramming complete all as specified and directed by Engr-in-Charge. |
| 3 | Removing surplus excavated soil to a distance n.exc. 50 metre anddepositing where directed at a level n.exc.1.5 metre high from the starting point complete all as specified and directed by Engr-in-Charge. |
| 4 | Material and Labour for sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and directed by Engr-in-Charge. |
| 5 | Supply and laying brick old size, sub class \"B\" brunt bricks laid in trenches as cable cover across the cable in trenches complete all as specified and directed by Engr-in-Charge. |
| 6 | All as per sr item No 5 here in before but using old bricks obtained under srl item No 1 here in before complete all as specified and directed by Engr-in-Charge. |
| 7 | Supplying, laying, jointing testing and connecting in replacementXLPE insulated, screened, PVCbedded, galvanised steel strip or wire armoured,electric power cable (heavy duty) with multistranded aluminum conductors,IS 7098marked, suitable for LT 1100 Voltsystem, laid in trenchesfixed to pole, including jointing & testing complete all as specified and directed by Engr-in-Charge of following sizes:-Note :-Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule. |
| 8 | All as in item No 7here-in-before but16 Sqmm 4 Core |
| 9 | All as in item No 7 here-in-before but50 Sqmm3.5 Core |
| 10 | All as in item No 7here-in-before but70 Sqmm3.5 Core |
| 11 | All as in item No 7here-in-before but 120 Sqmm 3.5 core |
| 12 | All as in item No 7here-in-before but 185 Sqmm 3.5 core |
| 13 | All as in item No 7here-in-before but 300 Sqmm 3.5 core |
| 14 | Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed by Engr-in-Charge. |
| 15 | Material and Labour for GI tubes of size 80 mm dia (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by Engr-in-Charge. |
| 16 | Material and Labour for GI tubes of size 50 mm dia (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by Engr-in-Charge. |
| 17 | Material and Labour for GI tubes of size 40 mm dia (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by Engr-in-Charge. |
| 18 | Supply, installing, testing and commissioning in replacement of factory made and testedBus bar chamberoutdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work,powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of size 450mm x 450mm x 300mm with 4 Nos500 Amps aluminium bus bar and with 250 Amp MCCB,4 pole, 36 KA, 415 Volt 50 Hz including excavation,earth workand platform for the Bus bar chamberwith PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class \"B\", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber.The platform shall be such that it is of a height 45 cm above the nearest road level complete all as specified and directed by Engr-in-Charge. |
| 19 | Material and Labour for earthing complete with galvanized Steel earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 meters below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and incl galvanized iron strip 25X4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by GI protection pipe light grade 40mm dia connected to main earth wire on pole or controll board GI pipe light grade 20mm bore for watering funnel with wire mesh PCC chamber pit in PCC 1:3:6 type C-1 40mm yhick Precast RCC -25 cover reincorced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50m complete all as sprecified and shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engr-in-Charge. |
| 20 | Supplying & fixing of LED street light Fitting 60 watt LED, IP-66 protection, single peice pressure die cast aluminiumhousing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartmentwith high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable complete all as specified and directed by Engg-In-charge. |
| 21 | Supply and Fixing in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Ampsincluding embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut,bolts & washer complete all as specified and directed by Engr-in-Charge. |
| 22 | Supplying, install and erect in true vertical position steel tubular swaged weldedpole in replacement of PCC poles , 9.0 meter long of appx weight 147 Kg conforming to IS-2713 part-II, type 410 SP-31, complete with cast iron/MS base plate 6mm thick and of size 300x300mm,finial taper, pole cap, bolts, nuts, washers & screws etc., pole made out of ERW M.S. tubing including of holes of reqd Nos and size for fixing of cross arms, GI pipe for cable protection etc. and GI bracket made of GI pipe medium grade 40 mm bore , 1.5 mtr long for fixing of street light fitings alongwith clamps, paintingwith one coat of red oxide primer and two coats of aluminium paint for exposed surfacesand two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bends at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No the black paint by stenciled letters/figures of 8cm height complete all as specified and directed by Engr-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed by Engr-in-Charge. |
| 23 | Supply and Fixing for wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed/on pole as required of size 2x1.5 sqmm + 1x1.50 sqmm earth wire alongwith and included steel conduit painted black and suitable size of MS clamp for connection of street light from MCB box at polecomplete all as specified and directed by Engr-in-Charge. |
| 24 | Supplying & fixing of LED flood lightFitting 120 watt LED, IP-66 protection, single peice pressure die cast aluminiumhousing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartmentwith high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable complete all as specified and directed by Engr-in-Charge. |
| 25 | Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT Panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZAC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The fixing of doubledoors shall be on MS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work,powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size ( but not less than 2.5 Sqmm)and complete all as specified and directed by Engr-in-Charge comprising of the following:-(a) Incoming :-(i)MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 35 KA, with microprocessor release - 01 Nos(ii) Voltmeter 0-500 volts digital typewith 4 way rotary selector swicth -01No (iii)Ammeter digital type with 4 way rotary selector switch-01No (iv)CTsratio 400/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three(vi)Aluminium bus bar of rating 800A- set of four (b) Outgoing(i) MCCB 4 pole , 250Amps, 50 Hz,415 Volts, 25 KA with thermal magnetic release- 03 Nos(ii)MCCB 4 pole , 125 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release- 03 Nos(c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class \"B\", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. Note :-(i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) All MCCBwithadjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer |
| 26 | All as in item No 19here-in-before but comprising complete all as specified and directed by Engr-in-Charge of the following:-(a) Incoming :-(i)MCCB 4 pole , 315 Amps,50 Hz,415 Volts, 36 KA, with microprocessor release - 01 Nos(ii) Voltmeter 0-500 volts digital typewith 4 way rotary selector swicth -01No (iii)Ammeter digital type with 4 way rotary selector switch-01No (iv)CTsratio 250/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three(vi)Aluminium bus bar of rating 500 Amps- set of four (b) Outgoing(i) MCCBFP ,125Amps,50 Hz,415 Volts, 25KA with thermal magnetic release- 02Nos(ii)MCCBFP , 63 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release- 04 Nos |
| 27 | Supply & Fixing in replacementbracket for street light fitting complete with 2.2 mtr long 50mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers and painting on steel surfaces with two coats of aluminium paint complete all as specified and directed by Engr-in-Charge. |
| 28 | Material and Labour for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by Engr-in-Charge. |
| 29 | Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work orderand shall be verified by the Engr-in-charge. |