| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 2 | In cement mortar |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 4 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 6 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 7 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 8 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 9 | 12 mm cement plaster of mix : |
| 10 | 1:6 (1 cement: 6 fine sand) |
| 11 | Reparing 50 Mmm G.I.Pipe line including G.I. Fitting Etc. Complete. |
| 12 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 13 | 20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. |
| 14 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. |
| 15 | With cement mortar 1:4 (1cement: 4 coarse sand). |
| 16 | Making repairing of leaking GI pipe line including trenching wherever required / dismantling the existing pipe line, making repairing with M seal or by adding small piece of GI pipe/ GI nipple as required, filling the trenches, re-fixing the pipe all complete as per the direction of Engineer-in-Charge.(Payment includes complete job including labour & material required) |
| 17 | Replacement of Indian type orissa pattern W.C. pan of size 580 x 440 mm by dismantling existing broken WC including replacement of P trap if reqd. repairing the floor complete as per direction of Engineer-in-Charge. |
| 18 | P/F polythelene cover to be fixed on PVC tank all complete as per the direction of Engineer-in-Charge. |
| 19 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 20 | 10 litre capacity - White |
| 21 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : |
| 22 | Flat back wash basin of size 630x450 mm. |
| 23 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 24 | 32 mm dia |
| 25 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 26 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45cm length |
| 27 | 15 mm nominal bore |
| 28 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 29 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 30 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 31 | 15 mm nominal bore, 86 mm long. Weighing not less than 88gms. |
| 32 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. |
| 33 | 25 mm nominal outer dia .Pipes. |
| 34 | 32 mm nominal outer dia .Pipes. |
| 35 | Providing and fixing PPR Unions |
| 36 | PPR Union 25 mm |
| 37 | PPR Union 32 mm |
| 38 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 39 | Felling trees of the grith(measured at a Height of 2 m. And above ground level) including cutting of trunks and branches,removing the the roots and stacking of serviceable marerial and disposal of un serviceable material; |
| 40 | Beyond 150Cm grith up to and including 40 cm grith. |
| 41 | 15 to25 mm plaster on cement concrete or reinforced cement concrete work with polymer modified liquid of approved make and making chequer pattern as per the direction of Engineer-In-Charge. |
| 42 | Scafolding all complete with ballies and necessary item with labour including complete for plaster work.Upto floor 3 Label |
| 43 | 15mm cement plaster on the rough side of single or half brick wall of mix: |
| 44 | 1:6(1 Cement : 6 fine sand) |