| 1 | M & L for servicing of window/spit type A/C of any capacity/size/makeby removing from position drawing out the unit from cabinet, clearing the whole unit to be free from dust deposits rust etc, servicing of condensing units, evaporator coil, cleaning and servicing of grills, exhaust vent, shutter mechanism and re-fixing the AC unit in original position, connecting and testing complete all as required for smooth and efficient functioning complete all as specified and directed. Note :- Gas charging/top up,any parts/materials if required during servicing will be measured and paid seperately under respective items. |
| 2 | M & L for gas charging using R 22 refrigerant for split/window type A/C of any capacity/size/make including arresting of gas leakage by using gas welding complete all as directed. |
| 3 | M & L for gas charging using R 32 refrigerant for split/window type A/C of any capacity/size/make including arresting of gas leakage by using gas welding complete all as directed. |
| 4 | M & L for shifting ofSpilt AC indoor and outdoor unit complete all as specified and directed. Note :- Wall mounted stand for fixing out door unit will be measured and paid seperately under respective items. |
| 5 | M & L for Repair ofPCB Circuit of Split type AC complete all as specified and directed . |
| 6 | M & L for replacement ofPCB Circuit of inverter Split type AC complete all as specified and directed . |
| 7 | M & L for Repair/Rewinding of blower Fan motor of windowtype AC complete all as specified and directed . |
| 8 | M & L for Starting Capacitor 40/50 MFD for Split/window type AC complete all as specified and directed . |
| 9 | M & L for Running Capacitor 6 MFD for split/window type AC complete all as specified and directed . |
| 10 | M & L for Contractor for out door unit of SplitAC complete all as specified and directed . |
| 11 | M & L for fixing of new stand for split AC outdoor unit complete all as specified and directed . |
| 12 | M & L for repair of circuit wiring of indoor unit of Spilt type AC complete all as specified and directed . |
| 13 | Dismantling/taking out of unserviceable compressor from outdoor unit of split type AC of cap 1.5 TR by removing all electrical connection and disconnecting from condensor/evaporating coil by using gas welding and Supply and fixing new compressor of same cap & same size connection and testing complete all as required. |
| 14 | Dismantling/taking out of unserviceable compressor from outdoor unit of split type AC of cap 2 TR by removing all electrical connection and disconnecting from condensor/evaporating coil by using gas welding and Supply and fixing new compressor of same cap & same size connection and testing complete all as required. |
| 15 | Dismantling/taking out of unserviceable copper condensor from outdoor unit of split type AC of cap 1.5 TR by removing all electrical connection and disconnecting from condensor/ evaporating coil by using gas welding andbrazing the condenser coil and refixing , testing complete all as required. |
| 16 | Dismantling/taking out of unserviceable copper condensor from outdoor unit of split type AC of cap 2.0 TR by removing all electrical connection and disconnecting from condensor/ evaporating coil by using gas welding andbrazing the condenser coil and refixing ,testing complete all as required. |
| 17 | Material & labour andrepair of Indoor unit cooling coilfor split type AC 1.5 Ton capacity of suitable make and model all as required at site and as directed by Engr-in-Charge. |
| 18 | Supply and fix inrepair of Indoor unit cooling for split type AC 2 Ton capacity of suitable make and model all as required at site and as directed by Engr-in-Charge. |
| 19 | Material & labour and repair of outdoor unit condensor any typefor split type AC 1.5 Ton capacity of suitable make and model all as required at site and as directed by Engr-in-Charge. |
| 20 | Material & labour and repair of outdoor unit condensor any typefor split type AC 2 Ton capacity of suitable make and model all as required at site and as directed by Engr-in-Charge. |
| 21 | Labour charges for taking out and refixingfixing of Geyser, icluding fastener, fixing of pipe, angle cocks, bib cock etc complete all as specified and directed by Engr-in-Charge |
| 22 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 |
| 23 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 24 | Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore. |
| 25 | S&F of copper pipe with cover1/2\", 1/4\" dia and 3/4\",SplitAC\"smake:-as required. |
| 26 | Replacement of Remote (handset) of window/splitAC’s (originalcompany make) |
| 27 | Supply and fix heating element 1KW/2KW triangle or round shape all are required st site condition |