| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group \"B\"). |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.A) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire the following sizes FRLS PVC insulated copper conductor, single core cable in surface/ recess medium class PVC conduit as required. A) 2 x 4 sq. mm + 1 x 4 sq. mm |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire the following sizes FRLS PVC insulated copper conductor, single core cable in surface/ recess medium class PVC conduit as required. A) 4 x 4 sq. mm + 2 x 4 sq. mm |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.A) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 6 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. A). 3X 1.5 Sqmm Wire |
| 7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. B). 5 X 6Sqmm Wire |
| 8 | Supplying and fixing of following sizes of mediumclass PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. A) 32 mm |
| 9 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 11 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providing &fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16amps modular switch, connection etc. as required. |
| 12 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required. |
| 13 | Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 4 way (4 + 12), Double door |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Single pole |
| 15 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.A) 40 Amp |
| 16 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) 63 Amp |
| 17 | Supplying & fixing suitable size GI box wih modular plate andcover in front on surface or in recess including providing andfixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 18 | LED Panel light 2x2ft.(System lumen efficacy ≥120<135 lm/Watt). Supplying, Installation, Testing & Commissioning ofPanel light 2x2 ft.,of following body material andconstruction as per IS : 10322 with driver as per therequirementwith Driver efficiency >85%, Operatingvoltage AC140-270 Volt,frequency50/60hz, Operatingtemprange-50Cto40 0C,internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95,IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flickershould be below 5 %), life time (LED, Driver & electrical circuitry), of minimum50000 Burning Hours with , 70% of initial Lumenmaintained tilllife ends, CCT 3000°K /4000°K/5700°K/6500°K(As perANSI Bin), SDCM(Standard Deviation Color Matching) <3,Maximumpower consumption should not more than the specified rating and Fixture shall be ofrelevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete inallrespecti/c external connectionswith1.5sq mmFRLS/HFFR,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120<135 lm/Watt output .LM79 & LM80 Test report andalltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkof aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm)a) 36 Watt |
| 19 | Supply, Installation, Testing and Comissioning ofAir Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/ R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe,the system shall be capable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity withScroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM)warranty both compressor andPrinted Circuit Board (PCB) as specified.The system shall be able to deliver 100% ofthe rated capacity as per relevant IS Code. Thelab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as perInternational Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.a) Inverter Type- Cooling only 2.0 TR with 5 Star BEE Rating |
| 20 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body materialand construction as per IS : 10322 withdriver (Replaceable)as per the requirement with Driver efficiency >85% ,Operating voltage AC140-270 Volt,freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI>80, Flicker free, (flickershould be below 5 %), life time (LED,Driver & electrical circuitary), ofminimum 50000BurningHourswith,70%ofinitial Lumenmaintained tilllife ends, CCT3000°K/ 4000°K / 5700°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard andtrade markcertificate(T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completeinallrespecti/c external connectionswith1.5sqmmFRLS/HFFR,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥105 <120lm/Watt output . LM79 & LM80 Test report andalltestingrequiredforLED fixtures as per BISshall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminiumhousing such that LED junction temperature shall not rise above 90°C). Powdercoateddiecast/Extruded aluminiumBody (Thickness > 1.20 mm) A) 18- 22 Watt |
| 21 | Supply and fixing of 400 mm sweep size wall fan suitable for operation on 230 Volt, 50 Hz including connection, testing etc. complete as required. (Model No. Striker Hi speed, USHA make or it\"s equivalent to Havells/Khaitan/Bajaj make) |