| 1 | Supply of steel Tubular pole 8.5 to 9.00 mt with Red oxide painted 410/SP.-29 swaged type steel tubular pole in single part along with 300X300X6 base plate & 100X3 top cap(Confoming to IS 2713 (PART I TO III) : 1980 or equivalent with upto date amendments ) |
| 2 | Erection of metallic pole of above 8 meter and upto 10 meter length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. (Confoming to relevent BIS/IS standard or equivalent) |
| 3 | Supply of ABC clamp |
| 4 | Supply of ABC hook |
| 5 | Supply of Suspension Clamp |
| 6 | Supply of Dead Clamp |
| 7 | Supply of PG connector |
| 8 | Supply of PG Clamp |
| 9 | Supply of PVC sheathed L.T. ABC Cable of 1.1 KV Grade Al Conductor cable as reqd as per IS-14255 3X70 + 1X16 + 1X50 sqmm |
| 10 | Erection of ABC Cable on existing poles including fixing accessories as reqd. |
| 11 | S/I/T/C of weather proof 3 phase SMC MOULDEDSERVICE CONNECTION BOARDS / Busbar box for AB Cables with pole mounting arrangement, with cable entry from bottom or sides and Busbar for high fault currents(Confoming to relevant BIS/IS standard or equivalent) |
| 12 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts,bolts and washer, painting the flat iron with primer and finish paint etc. as required. (conforming to IS-1239 part 1 (2004) or equivalent) |
| 13 | LED Street light fixture, powder coated pressure die cast aluminium body (system lumen efficacy≥105<120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED Fixture powder coated pressure die cast aluminium body with driver as per requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50°C, internal surge protection of 5KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD< 10% as per IEC 61000-3-2, P.F. ≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000 °K / 4000 °K / 5700 °K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching ) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105<120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90 °C). |
| 14 | 120 Watt |
| 15 | 90 Watt |
| 16 | Supply of PVC insulated PVC sheathed cable of 1.1KV grade armouredUnderground aluminum conductor cable as reqd confirming to IS –7098 part I with up to date amendments) of the following size as per direction in charge. |
| 17 | 3.5X50 sqmm |
| 18 | 3.5X35 sqmm |
| 19 | 4X25 sqmm |
| 20 | 4X16 sqmm |
| 21 | 4X10 sqmm |
| 22 | 4X6 sqmm |
| 23 | 2X10 sqmm |
| 24 | 1X16 sqmm |
| 25 | Supplying and drawing ofFlexible PVC round insulated FRLS copper cable of following sizea)3 X 1.5 SQMM |
| 26 | Supplying and fixing of light class G.I. pipe of 50 mm dia.(nominal) 3metres length along the pole for protection of underground cable as required.(conforming to IS-1239 part 1 (2004) or equivalent) |
| 27 | Supplying , installation , testing and commissioning ofcubical type,inverted V shaped top, outdoor feeder pillar panel with size (1.0x1.0x.4 Mtr) suitable for operation at 415 (+/-) 6% Volts,50Hz,3 Phase 4 Wire system made outfromCRCA sheet steel 2.0 mm and covers shall be cold rolled sheet thickness not less than 1.6mm fabricated factory finished followed-42 by powder coated painting & provided with gaskit etc. to make dust & vermin proof degree of IP ,Weather Proof, hinged type openable door , loaking arrangement , detachable gland plate , connection , interconnections with suitable size (150 Amp capacity) 4 striphigh conductivety elctrical aluminium (ALU) busbar codifies in red,yellow,blue and black colour and PVC insulated copper conductor cable 1100Volt grade for internal wiring including providing and fixing digital type Ampere meter, Voltmeter, Indication LED lamp, ,Labeling comprise white letters on black background including foundation works etc as required with following:- (Confoming to relevent BIS/IS standard or equivalent)1) 4P MCCB 125Amps,36KA-01No2) 4P MCCB 100 Amps.36KA-01 Nos3) 4P MCCB 63 Amps.25KA-04 Nos4) MCB DP 40 Amps -02 Nos5) TPN MCB 63Amp-02 Nos6) 4 strip AL Busbar 150Amp- 01 Set |
| 28 | Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required. Upto 35 sq. mm |
| 29 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 30 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required (Confoming to relevent BIS/IS standard or equivalent) |
| 31 | Supply, installation, testing and commisioning of weather proof MS loop in loop out busbar box havin 4P MCCB 63Amp and of size not less than450x350x200 mmwith 4 Nos. suitable capacity ALU (upto 150 Amp) Bus Bar (R,Y,B & N) duly finished and painting, detachable gland plate & Arrangement for interconnection etc as required. (Confoming to relevent BIS/IS standard or equivalent) |
| 32 | Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (conforming to IS 12943 (1990) or equivalent) |
| 33 | 3.5X50 sqmm (35mm) |
| 34 | 3.5X35 sqmm (32mm) |
| 35 | 4X25 sqmm (28mm) |
| 36 | 4X16 sqmm (28mm) |
| 37 | 4X10 sqmm (25mm) |
| 38 | 2X10 sqmm (19mm) |
| 39 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted/welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm and fixing the same in ground as required. |
| 40 | Supply , Installation, Testing & Commissioning of loop in loop out box made of PVC sheet 200x 150x100 mm having suitable size 2 nos. terminals and 1 no. SP MCB 5/6A detachable gland plate, interconnection etc as required |
| 41 | Supplying and fixing of 20A, TPN, indutrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure with connections, testing and commissioning etc. as required. |