| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C ) |
| 3 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.a) 3X1.5 Sqmm |
| 4 | b) 3 X 2.5 Sqmm |
| 5 | c) 3X4 sqmm |
| 6 | d) 3x6 sqmm |
| 7 | Supplying and fixing following size/ modules, GI /PVC box alongwith modular base & cover plate for modular switches in recess etc.as required.Make:- M/s Anchor/ L&T/ Legrand/SSa) 3 Module |
| 8 | b)6 Module |
| 9 | c) 12 Module |
| 10 | e)1or 2 module |
| 11 | Supplying and fixing of following modular switches on the existing modular plate & switch box incl including connections but excluding modular plate etc as reqdM/s Anchor/ L&T/ Legrand/SSa) 5/6 A switch |
| 12 | b) 15/16 A switch |
| 13 | c) 3 pin 5/6 A socket outlet |
| 14 | d) 6 pin 15/16 A socket outlet |
| 15 | e)RJ 11 Socket out let |
| 16 | f) RJ 45 Socket out let |
| 17 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as requireda) 1 run of cable |
| 18 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.a) 25 mm |
| 19 | b) 20mm |
| 20 | Providing and fixing of UPVC DLP trunkingandfixing on the wall with fixing accessories including cover and partion etc complete as reqd ( Make :- legrand/ MK/ MDS)a) 105mmX50 mm |
| 21 | b) 80mmX50mm |
| 22 | c)50 mm X 16 mm |
| 23 | d)25 mm |
| 24 | Supplying and fixing following way, single pole/3pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)a) 12 waySPN double door |
| 25 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single pole |
| 26 | b) Double pole |
| 27 | Supplying, installation, testing and commissioningof 36 to 40W LED energy efficient fitting having size 4Ft X 1Ft led and making suitable arrangement for hanging in ceiling etc. complete as required. (Make Havells/ Wipro/Philips/Cromoton/Surya |
| 28 | Supplying, installation, testing and commissioningof 36 to 40W LED energy efficient fitting having size2Ft X 2Ft led and making suitable arrangement for hanging in ceiling etc. complete as required. (Make Havells/ Wipro/Philips/Cromoton/Surya |
| 29 | Providing nd fixing of 20 watt 4 feet long LED fittingsand fixing on the wall withfixing accessoriesand connection etc complete as reqd(make :- Havells/ Philips/ Wipro) |
| 30 | Supply and laying of following sizes of aluminum armoredcable of 1.10 KV grade and laying on the existingwall/ cable trey with fixing accessories etc complete as reqda) 2X 16 Sqmm ( Make :- Havell/ Poly cab/ grandlay) |
| 31 | Supplying and making end termination with brass compressiongland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as requireda) 2X 16sqmm |
| 32 | Supplying & drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, un armored telephone cable in the existing surface /recessed steel/PVC conduit /PVC/MS Channel etc complete as reqd |
| 33 | Supplying & fixing following size MS krone box with krone plate, base etc complete as reqd a)10 pair krone box with complete accessories |
| 34 | Supply and laying of following sizes of aluminum armoredcable of 1.10 KV grade and laying on the existingwall/ cable trey with fixing accessories etc complete as reqd ( Make :- Havell/ Poly cab/ grandlaya) 3.50 coreX 50 Sqmm |
| 35 | Supplying and making end termination with brass compressiongland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as requireda) 3.50 coreX 50sqmm |
| 36 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 37 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \"C\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 38 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 39 | Supplying and fixing of following sizes of wall mounted wall fan operation on 415 Volts, 50 HZ AC Supply and fixing on the wall with fixing accessories etc complete as reqd . ( Make :- Havells/ Crompton/ Usha/Orient/bajaj/SS)a) 400 mm |
| 40 | Supplying & fixing of 12 Port Cat-6 Patch panel including 24 port switch and jack, RACK, PATCH CODE including connection testing and commissioning etc. complete as required. |
| 41 | S/F Polycarbonate 16A 3 Pin Flat Plug Top Constituting Heavy Brass Parts and Longer Durability, Elegent Design with Glossy Finish,Cord Grip Provided to Hold the Flexible Cable(White) etc complete as reqd |
| 42 | Shifting of 10 KVA/20 KVA UPS from one site to another site in the same floor with battery banks i/c dismantling of all i/p , o/pconnection ,i/p & o/P cables of UPS and reconnection after shifting etc complete as reqd |