| 1 | Civil Work |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains ( not exceeding 1.50 m in width or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the exacavated soil and disposal of surplus excavated soil as directed, within a lead of 15m.All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel:1:2:4 ( 1 Cement : 2 Coarse sand (Zone - III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 6 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering,finishing and reinforcement: All work up to plinth level : 1:2:4 (1 Cement : 2 Coarse sand (Zone - III) derived from natural sources: 4 graded stone aggregate 20 nominal size derived from natural sources) |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams,girders, bressumers and cantilevers |
| 12 | Centring and shuttering i/c strutting,propping etc and removal of form for: Columns, Pillars, Piers, Abutments, Posts ans Struts. |
| 13 | Steeel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete upto plinth levelThermo- Mechanically treated bars of grade Fe- 500 D or More |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in :1:6 (1 cement : 6 coarse sand) |
| 15 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 16 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab colour black, Cherry/Ruby redArea of slab over 0.50 sqm |
| 17 | Steel work welded in built up section /framed work i/c cutting ,hoisting ,fixing in position and applying a priming coat of approved steel primer using structural steel etc as required. In gratings, frames, guard bar, ladder, railing, brackets, gates and similar works |
| 18 | Marble stone flooring /Skirting/window, door Jambs/sill/lintal with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur green marble |
| 19 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 20 | 12 mm cement plaster of mix : 1 : 6 (1 cement : 6 coarse sand) |
| 21 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) |
| 22 | Finishing walls with water proofing cement paint on required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 23 | Painting with synthetic enamel paint of approved brand and manufactureof required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 24 | Supplying at site Angle iron post & strut of required size i/c bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia.etc.complete |
| 25 | Providing and fixing concentina coil fencing with required dia 610mm ( having 15 nos round per 6 mtr length upto 3 m height of wall with existing angle ironY shape placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. stud tied with G.I.staples and G.I.clips to retain horizontal i/c necessary bolts or G.I.barbed wire tied to angle iron all completeas per the direction of Engineer-In-Charge with reiforced barbed tape(RBT)/Spring core(2.5mmth.)wire of high tensile strength of 165kg/sqmm with tape (0.52mmth) and weight 43.478gm /mtr(cost of MS angle ,CC block shall be paid seperately. |
| 26 | Providing and fixing G.I.chain link fabric fencing of required width in mesh size 25x25mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as requiredcompleteas per the direction of Engineer-In-Charge. |
| 27 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 28 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 29 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 30 | Providing and laying unplasticised Rigid PVC SWR pipe wih min. pressure 6 kg/sqcm conforming to IS : 13592 ,Type B including jointing with adhesive (i) plain socketed pipes. |
| 31 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 32 | Providingand fixingplainmultipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 33 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating not less than 275 gm/m2 |
| 34 | Providing and fixing precoated galvanised iron profile sheets (size, shape andpitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shallbe fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 35 | Providingand fixing thermalinsulation withResinBondedrock wool conforming to IS: 8183, having density 48 kg/m3, 50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing GI wire etc. complete as per directions of Engineer-in-Charge. |
| 36 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 37 | Electrical work |
| 38 | Wiring for light point / fan point / exhaust fanpoint / call bell point with 1.5 sqmmFRLS PVC insulated copperconductor single core cable in surface / recessed steel conduit, with modular switch , Modular plate,, suitable size G I box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required Group A |
| 39 | Wiring for power plug with 2x4 sq. mm FRLS PVC insulated copper conductor singlecore cable in surface/recessed medium class PVC conduitalongwith4sqm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 40 | Wiring for circuit /submain wiring alongwith earth wire with the following sizes of FRLS / PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2x1.5 Sq. mm +1x1.5 Sq. mm earth wire |
| 41 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6Pin 5/6 & 15/16 A modularsocket outlet and 15/16 A modular switch connections as required. |
| 42 | Suppling and fixing 3pin, 5 A ceiling rose on the existing junction box including connections etc. as required. |
| 43 | Supplying and fixing following modular switch / socketon theexisting modular plate & switch box including connections etc but excluding modular plate etc as required. 5 / 6 amps switch |
| 44 | Supplying and fixing following modular switch / socketon theexisting modular plate & switch box including connections etc but excluding modular plate etc as required. 3 pin 5/6 A socket outlet |
| 45 | Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box includingconnections but excluding modular plate etc as required. |
| 46 | Supplying and fixing following size / modules,GI box alongwith modular base& cover plate for modular switches in recess etc as required. 3 Module (100 x 75 mm) |
| 47 | Supplying and fixing following size / modules,GI box alongwith modular base& cover plate for modular switches in recess etc as required. 8 Module (125 x 125 mm) |
| 48 | Supplying and fixingmodular base & cover plate on existing modularmetal boxes etc as required 3 Module |
| 49 | Supplying and fixingmodular base & cover plate on existing modularmetal boxes etc as required 8 Module |
| 50 | Supplying and fixingbrass batten / angleholder includingconnection etc as required. |
| 51 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC... Supply, earthing etc. complete as required |
| 52 | Supply and fixing following way, single and neutral, sheet steel, MCB Distribution Board, 240 V, on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required ( But without MCB/RCCB/ISOLATOR) 6Way double door |
| 53 | Supply and Laying of one no PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgradeofsize 2x25 Sqmm direct in ground including excavation , sand cushining , protactive coveringand refilling etc as required |
| 54 | Supplying and fixing of 12watt LED Bulb -B22/E27 (Colur temp.-6500K/Lumens-900 LM ) cool day light, Input volts (AC 90V -260V), 3star rating suitable for batten /angle holder including making connection complete in all respect. |
| 55 | Providing and fixing of Compound wall lights includingall complete as per direction of Engineer - in -charge |