| 1 | S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing |
| 2 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 3 | M&L taking down loose ceiling cement plaster including raking out joint hacking ,scrubbing down with water, Dubbing out average 10mm thick on irregular face of walls (when specifically ordered in writing) In 1:6 cement plaster.brushing neat cement slurry with 3.0 kg of cement per Sq.m & Rendering 15mm thick on fair faces of brick work or concrete surfaces of 1:3 cement mortar in ceiling.rendering is to be finished even and smooth (without using extra lime or cement). |
| 4 | S & F of Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mmnd web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to ntre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. Complete in all respect. |
| 5 | S&F of Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of faceboard with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately) |
| 6 | M&L for dismantling brickwork or stone/ boulder masonry, built in built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles. |
| 7 | M&L for Brick work with sub class \"B\" bricks,straight or curved on plan exc 6.0m mean radius built in cement mortar 1:4. |
| 8 | M&L Taking down old cement mortar plaster on wall including raking out joint hacking, scrubbing down with water. |
| 9 | M&L for applying neat cement slurry&rendering 15mm thick cement plaster 1:4 on wall& surface to be finished even & smooth. |
| 10 | M&L for preparation of surface of new plastered wall and Chalk whiting, on plastered surfaces, preparatory to distempering etc. |
| 11 | S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified (minimum thicknessof powder coating 50 micron) |
| 12 | Supply & Fixing of powder coating of any colour (Thickness or powder coating not less than 50 micron) Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified |
| 13 | Supply & Fixing of powder coating of any colour (Thickness or powder coating not less than 50 micron) Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beadingscrews etc. complete all as specified |
| 14 | S&F 6.3 mm thick Sheet glass, ordinary quality, frosted on one side and glazing with oil putty in square not exc 0.5 sq. m in each pane |
| 15 | S & F of Stainless Steel wire cloth,0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 16 | Cutting holes in brick walls exc. half brick but n. exc. one brick, built in cement mortar andmaking good to dismantled portion in cement concrete 1:2:4, Type B-1. |
| 17 | Demolition of PCCConcrete of any description and in any position not otherwise specifically provided for. |
| 18 | M&L cement concrete M-15, 1:2:4, 20.0 mm graded aggregate in foundation filling and mass concrete and finished surface even and smooth. |
| 19 | Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colored (Make- Johnson / Nitco/Kajaria)colour tile. |
| 20 | M/L for Formwork to sides of concretefoundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in fair finish surface. |
| 21 | M/L for RCC (Reinforced cement concrete) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like M20 & 20mm graded aggregate. |
| 22 | S&F of TMT Bars 10 mm dia and over cut to length,bent to shape required, including cranking bending spirally for hooping for columns, hooking each, binding with and including mild steel wire(annealed) n.less than 0.9mm dia or securing with clips. |
| 23 | M & L for taking down the Chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) and remove to store. |
| 24 | M & L for taking down the Shutters of any description exc 1 sqm but n exc 2sqm each. |
| 25 | S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified (Fixing only) |
| 26 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings |
| 27 | S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified (small patches). |
| 28 | M&L for 3mm thick wall care putty on wall |
| 29 | M&L for preparing the new surfaces, apply plastic interior emulsion two coat Surfaces of any description over 10cm girth or width, not otherwise described (Asian paints/ Nerolac, Berger) as approved by EIC. |
| 30 | S&F of PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors 4mm thick |
| 31 | M&L for preparing old painted surfaces of steel apply two coats of syntheticenamel paint (ordinary/ tint), not otherwise descri-bed, over 10cm width or girth on steel based surface.Make: (Apcolite of Asian paints, Dulux Gloss of ICI Paints, Goodlass of Nerolac) Shade as approved by EIC at the time of execution. |
| 32 | S&F of Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed |
| 33 | M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc, Brushing neat cement slurry with 3.0kg of cement per sq. metre®and Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes (1:4). |
| 34 | Removing building materials etc. to a distance of 100 m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination. |
| 35 | Supplied & fixed, of350A, MCCBs 415V, 36KA, 4 Pole (Make - CG/ Havells/ L&T/ BCH/ Schneider/ Siemens) |
| 36 | Supplied & fixed, of125A, MCCBs 415V, 16KA, 4 Pole (Make - CG/ Havells/ L&T/ BCH/ Schneider/ Siemens) |
| 37 | Supplied & fixed, of63A, MCCBs 415V, 16KA, 4 Pole (Make - CG/ Havells/ L&T/ BCH/ Schneider/ Siemens) |
| 38 | Supplied & fixed, of40A, MCCBs 415V, 16KA, 4 Pole (Make - CG/ Havells/ L&T/ BCH/ Schneider/ Siemens) |
| 39 | Supplied & fixed,for sheet metal Encloser for DB\"s, double door, Triple pole and neutral, 415V, 12 way, (Make Havells/ MDS /L&T/ Siemens) |
| 40 | M&L for 100A TPN MCB/Isolater, 415V (triple pole & neutral), (Make Havells/ MDS /L&T/ Siemens) |
| 41 | M&L for 40A DP MCB/Isolater with encloser box, 240V (single pole & neutral), (Make Havells/ MDS /L&T/ Siemens) |
| 42 | M&L for 40A MCB/Isolater 240V single pole (Make Havells/ MDS /L&T/ Siemens) |
| 43 | Taking down carefully aluminium /copper point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling rose, pendents, regulators, sockets etc to be measured sepatately) removing material to store for keeping in safe custody or for taking creadit, at site and making good disturbed surfaces of walls floors etc. |
| 44 | M&L for concealled type wiring for one light point or one fan point or 5A plug point controlled by one switch with 1.5 sqmm size copper cables FRLS in PVC conduit (Make Finolex/ Havells/Anchor), (iccluding PVC conduit / JB/ concelled boxes etc.). |
| 45 | M&L for flush type single pole, one way 5 Amp, piano type (Make Anchor/ Cub/ Cabtree/ Cona) |
| 46 | M&L for socket outlet 3pin, 5amp flush type (Make Anchor / Cabtree / Cub) |
| 47 | M&L for concealled type wiring for 15A socket out let with 2.5sqmm copper conductor cables FRLS in PVC conduit, independent wiring for each power point and additional 1.5sq.mm copper conductor cable for earth. (Make Finolex/ Havells/ Anchor) (iccluding PVC conduit / JB/ concelled boxes etc.). . |
| 48 | M&L for socket outlet 2 in 1, 6 pin, 5 and 15amp flush type (MakeAnchor/ Cona/ Cabtree) |
| 49 | M&L for 15A switch piano flush type (Make Anchor/ Cub/Cona) |
| 50 | M&L for fan step electronic regulator 120watts 2 module mini switch (Make Anchor/ Cub/ Cona) |
| 51 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete (Make Phillips/ CG / Syska /Wipro). |
| 52 | M&L Ceiling rose, 3 phase/PVC/polycarbonate, isolated body |
| 53 | M&L for cutting chases, pinning in making good to facing where require and pointing in cement morter 1:3 to ends or edges of landings, steps, chills, sunssades, selves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, cutting not exc 10 cm grith on brick walls. |
| 54 | Dismentaling of existing panel (incl. MCCB & SFU) frmwall mount type different size 16A to 63A TPN/SPN), each panel represents all accessories of single panel) |
| 55 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of acoat of bitumen primer for bitumen membrane @ 0.40 litre/sqm of the same manufactures as membrane of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer ofmembrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through theauthorised applicator of the manufacturer of membrane Make- STP,IWL,TATA. |