| 1 | 12 mm cement plaster of mix : (a) 1:6 (1 cement: 6 fine sand) |
| 2 | 15 mm cement plaster on the rough side of single or half brick wall of mix (a) 1:6 (1 cement: 6 fine sand) |
| 3 | Neat cement punning |
| 4 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. (a) With cement mortar 1:4 (1 cement : 4 fine sand). |
| 5 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade (a) One or more coats on old work. |
| 6 | Finishing walls with Acrylic Smooth exterior paint of required shade (a) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 7 | Finishing walls with Acrylic Smooth exterior paint of required shade : (a) Old work (One or more coat applied @ 0.90 ltr/10 sqm). |
| 8 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (a) 110 mm diameter |
| 9 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (a) Single tee with door (i) 110x110x110 mm |
| 10 | (b) Bend 87.5°(i) 110 mm bend |
| 11 | © Shoe (Plain)(i) 110 mm Shoe |
| 12 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (a) 110 mm |
| 13 | Uprooting of medium size trees/plants on brick masonary wall/RCC chajja, roof duct etc by cutting through axe,chisel and hammer including dugging and removing roots of trees/plants and pouring chemical into the chases and finishing the same as existing wall as per direction of EIC. |
| 14 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge (a) 75 mm average thickness |
| 15 | b) 50 mm average thickness |
| 16 | c) 25 mm average thickness |
| 17 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. a) Bars upto 12 mm diameter |
| 18 | b) Bars above 12 mm diameter |
| 19 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. a) Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make. |
| 20 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). (a) 12 mm average thickness. |
| 21 | b) 25 mm average thickness in 2 layers. |
| 22 | c) 50 mm average thickness in 3 layers. |
| 23 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: a) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |