| 1 | Taking down rolling shutter of any description with or without ball bearing & with/ without gear box incl taking out lugs etc incl top cover anchoring rod complete all as specified and as directed. |
| 2 | S&F in repairs steel rolling shutter of thickness of laths 1.25mm with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; push pull or manual type incl greasing incl match to the existing suface with cement work and finishing complete Note: Paint will be mesured and paid separatly complete all as specified and as directed. |
| 3 | Repairs to rolling shutters without taking off rolling shutter securing or easing, cleaning/greasing/oiling/ overoiling/welding in gear box, crank handle, rolling spring, channels, ball bearing, pully, adjustment of lock device, including replacement of berm & any description n.exc 6.00sqm each complete all as specified and as directed. |
| 4 | Repairs to rolling shutters without taking off rolling shutter securing or easing, cleaning/greasing/oiling/ overoiling/welding in gear box, crank handle, rolling spring, channels, ball bearing, pully, adjustment of lock device etc, & any description exc 6.00sqm but n.exc 32.00sqm each complete all as specified and as directed. |
| 5 | S&F in repairs MS floor, safety lock suitable for rolling shutter 4 levers goodrej or equivalent with duplicate keys fixed incl necessary cement repair complete all as specified and directed. |
| 6 | Repalcement of damaged 40mm dia medium gde MS pipes in single length including welding in existing rolling shutter complete all as specified and as directed. |
| 7 | Replacement of damaged top pinnion in existing rolling shutter all as required and as directed |
| 8 | Replacement of damaged shaft spring suitable for large size rolling shutter of opening exc 3.00m wide heavy duty etc complete all as specified and as directed. |
| 9 | Replacement of damaged shaft spring suitable for small size rolling shutter of opening n.exc 3.00m wide heavy duty etc complete all as specified and as directed. |
| 10 | Replacement of damaged shutter spring suitable for rolling shutter of opening exc 3.00m wide heavy duty etc complete all as specified and as directed. |
| 11 | Replacement of damaged shutter spring suitable for rolling shutter of opening n.exc 3.00m wide heavy duty etc including dismantling and refixing of shutter complete all as specified and as directed. |
| 12 | Replacement of damaged gear box connecting rod 25mm dia GI medium grade tube complete all as specified and directed |
| 13 | Replacement of damaged roller assembly suitable for rolling shutter of opening n.exc 3.00m wide heavy duty etc including dismantling and refixing of shutter complete all as specified and as directed |
| 14 | Replacement of damaged roller assembly suitable for rolling shutter of opening exc 3.00m but not exc 6.00m wide heavy duty etc complete all as specifed and as directed |
| 15 | S&F in repairs automatic floor mounted hydraulic door closer, heavy duty with pivot, aluminium body ISI marked, complete all as specified and directed. |
| 16 | S&F in repairs automatic hydraulic door closer, heavy duty with pivot, aluminium body ISI marked, complete all as specified and directed. |
| 17 | Demolition of brick work or stone/boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 18 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed. |
| 19 | Brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius built in CM 1:6 but except brick. |
| 20 | Demolition ofcement concrete of any position not exc 15 cm thickness, above or below ground level, unreinforcedcomplete all as specified and as directed. |
| 21 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for cut as required to facilitate demolition complete all as specified and directed. |
| 22 | M&L reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in walls complete all as specified and directed. |
| 23 | M&L for mild steel TMT bars 10 mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 24 | Use & waste of formwork to faces of walls,and similar work etc.; vertical or to batter complete all as specified and directed. |
| 25 | M&L 75mm thicknessPCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as insub base of plinth protection/sub base complete all as specified |
| 26 | M&L for Chequered cement concrete tiles 300 x 300m x 25mm thick incl Screed bed 15mm thick in CM 1:6 set, jointed and pointed in near cement slurry in floors with grey cement and pigment |
| 27 | M&L 100mm thicknessPCC 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as inhardstanding incl necessary joints with bitumen joint filling complete all as specified |
| 28 | Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 29 | M&L rendering 15mm thick onfair faces of brick work in cement mortar 1:4 with WPC as per manufacture instructions finished even and smooth w/o using extra cement complete all as specified and directed. (Note: WPC will be measured and paid separatly) |
| 30 | Supply only integral water proofing compound (mix in cement morter as per manufacture instructions). |
| 31 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed. |
| 32 | S&F in repairs roof trusses (framed), trussed purlins single angle iron, including distance pieces, cleats etc Fe 410-W (Gde E 250) quality A complete all as specified and directed. |
| 33 | M&L for preparation of newly plastered surfaces of walls and applying two coat of cement base paint over a coat of primer complete all as specified and directed. |
| 34 | M & L for preparation of new steel surface over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 35 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc or insulation boards/ slabs/ blankets any thickness including cover filletts complete all as specified and as directed. |
| 36 | S & F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre. size of grid 605 mm x 605mm complete all as specified and as directed. |
| 37 | S &F Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long (removing old hangers) complete all as specified and as directed. |
| 38 | S & F exposed metal frame ceiling with calcium silicate board6 mm thick of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid (Frame work for ceiling shall be measured and paid separately) complete all as specified and as directed. |
| 39 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering/valley gutter etc complete all as specified and directed |
| 40 | S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed self tapping screws complete all as specified and as directed. |
| 41 | S & F for pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding/valley gutter to wall, fixed self tapping screws complete all as specified and as directed. |
| 42 | Dismantaling of Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coveringscomplete all as specified and as directed. |
| 43 | M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls and fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed. |
| 44 | S&F In repairs framed work such as grill grating, gates etc with ends of bars shouldered or riveted or forged into spikes frame guard bars etc all complete all as specified and as directed. |
| 45 | M&L in repairs 30mm thick Dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size exceeding 0.25 sqm and notexceeding 0.5 sqm area fixed with and including one number SS clamps (grade-202) of flat 30mmxx 2mm, 150 mm long made to shape in each slab, making V groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment Note: The stone size and colour will be provided as per existing on walls and also finished the joints / grooves even and smooth complete all as specified and as directed. |
| 46 | M&L in repairs 25mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.Note:The stone size and colour will be provided as per already existing on walls and also finished the joints / grooves even and smooth. |
| 47 | Removing existing water proofing treatment of any description from roof slabs, cleaning the surface using wire brushes etc, roughening the concrete surfaces picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.00 kg of cement per Sqm (Where PCC padding is to be provided) complete all as specified. |
| 48 | M & Lfor preparation of old roof surfaces by brooming and watering, cleaning all dust particles and providing PCC (1:2:4) type B-0,(using 12.5 mm graded crushed stone aggregate) with water proofing compound as per manufacturer instruction asinpaddding/ levelling course of average thickness not exceeding 25mmcomplete all as specified and as directed.Note : Water proofing compound will be measured and paid separately. |
| 49 | M & L preparation of newly plastered surfaces of roof including cleaning the surfaces by using wire brush/ pressure hose and applying high performance polyurethene liquid membrane waterproofing coating cold applied in two coats @ 1.5kg/Sqm/2coats spray/brush applied, with an elongation of 300% to 700% and tensile strength of not less than 3N/Sqmm as per ASTM D412 and ASTM C2370, crack bridging ability of 3.5mm as per ASTM C1305, shore a hardnessof not less than 60 as per ASTM D2240. The item includes applying epoxy primer @ 0.15Kg/Sqm and a geotextile of 40 GSM to be applied over first coat while first coat is still wet complete as per manufacturer\"s instructions. |