| 1 | Surface dressing n.exc 15cm deepin hard /dense soil n exc 1.5 complete all as specified & directed. |
| 2 | M&L for excavating in trenchesn.exc 1.5m wide and n.exc 1.5m deep for foundation in any type of soil and getting out etc complete all as specified & directed. |
| 3 | Removing of excavated material n.exc 50 mtr and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified & directed. |
| 4 | Returning filling in including spreading levelling watering &well ramming in layers n.exc 25 cm in hard/dence soil complete all as specified & directed. |
| 5 | M&L for plain cement concrete 1:4:8 type B2 (40 mm graded aggregate) for foundation fillings and mass concrete complete all as specified & directed. |
| 6 | M&L brick work with sub class \"B\" bricks straight or curved on plan exc 6M mean radius in CM 1:6 complete all as specified & directed. |
| 7 | M&L for PCC 1:2:4 type B-1( using 20 mm graded stone aggregate) in coping etc including necessary from work complete all as specified & directed. |
| 8 | S & F oil and grease trap for 100 users size (1000x750x600 mm) or as per specified by Engr-in-charge made of Stainless steel of grade 304 complete all as specified & directed. |
| 9 | M&L Cutting in to existing manholes for connecting new drains making good to pipe of size 150mm dia and rendering cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1 :2 : 4 type B-1 smooth finished and reforming benching as required of 150mm dia of pipe complete all as specified & directed. |
| 10 | S&F PVC (SWR) 110 mm bore pipes double socketed, in any length with rubber ring joints laid in trenches or in floors or complete all as specified & directed. |
| 11 | S&F PVC (SWR) 110 mm bore,junction double, (double T), equal or unequalcomplete all as specified & directed. |
| 12 | M&L for Point wiringfor One Ceiling fan/exhaust fan point controlled by one switch or one ceiling fan point controlled by one switch & fan regulator etc. with 1.5 Sq. mm (nominal area), multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 1.5 Sq. mm (nominal area) PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawin in and including rigid non metallic PVC heavy duty concealed conduit, GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed. |
| 13 | S&F Switch piano, flush type, single pole, one way, 6 Amp complete all as specified & directed. |
| 14 | S&F Supply and fix ceiling fans, 1200mm sweep, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor and making connection from ceiling rose or connector to fan complete all as specified.NOTE:The length of suspension rod shall be as per site requirement. |
| 15 | Fan regulator, stepped type, electronic type, heavy duty, flush type 230V AC. |
| 16 | S&F Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan complete all as specified & directed. |
| 17 | M & L For Making hole in Brick/stone wall for exhaust fan of size 250 mm to 350 mm Sweep,making it smooth by plastering internal surface of hole ,Taking down exhaust fan safely from existing site and fixing on the fresh hole Connecting to electrical cicrcuit , provisioning for Flap(metal)outside of wall for Mosquito/fly safety complete all as specified & directed. |
| 18 | S&F Anti suicide Fan Rod(18\") white/Brown ,other including metallic as per need MS pipe Zinc Plated pipe OD-19mm, thickness 1.8+/- 0.05 mm,Spring set grade 3 Carbon Spring steel material suitably tested and Rod tested for axial sudden pull/impact test with axial load of 22Kgs supported and spring holding the lower pipe expanding upto 1000mm without breaking ,the rod will get open from centre spring will be expanded , fan clamp with rubber reel nut bolt & safety pin as suitable for ceiling fan complete all as specified and as directed. |
| 19 | M & L for street light fitting 60 watt pressure die cast aluminium housing Heat resistance toughened glass IP 66 protection better optics for uniform distribution complete all as specified & directed. |
| 20 | Supply and fixing in replacement , bracket made out of 25 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as direct ,02 nos clamps made out of MS flat iron 40X6mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete all as specified & directed.(Rates quoted by the contractor shall deemed to include for nut and bolts). |
| 21 | Supply and Fix in repair cable FRPVC insulated PVC sheathed with multistranded copper conductor of size 2.5 sq mm 2 core and connecting to the street light feeder complete all as specified & directed. |
| 22 | S & F SS 202 Hood with Baffle Filter Size :4\"x2.5\"for Industrial Chimney Stainless steel complete all as specified & directed. |
| 23 | S & F 24\" Tube Axial Fan with 1HP 1440RPM Motor-01 nos & stater for Industrial Chimney Stainless steel complete all as specified & directed. |
| 24 | S & F 0.60 mm GI Ducting for Industrial Chimney Stainless steel complete all as specified & directed. |
| 25 | M & Lfor Canvas Connection For Fan for Industrial Chimney Stainless steel complete all as specified & directed. |