| 1 | Excavating in trenches for hard rock, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out complete all as specified & directed. |
| 2 | Removing of excavated material n.exc 50 mtr and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified & directed. |
| 3 | Returning filling in including spreading levelling watering &well ramming in layers n.exc 25 cm in Soft/lossesoil complete all as specified & directed. |
| 4 | M&L for providing PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified & directed. |
| 5 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (horizontal or sloping) complete all as specified & directed. |
| 6 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; verticle or to batter complete all as specified & directed. |
| 7 | M&L for Formwork tosides of pillars, posts, struts, piers,columns and stanchions complete all as specified & directed. |
| 8 | M&L for Reinforced cement concrete M-25 Grade using of 20 mm graded stone aggregate for foundation, footing and mass concrete complete all as specified & directed. |
| 9 | M&L for Reinforced cement concrete M-25 Grade using of 20 mm graded stone aggregate forColumns, pillars, piers, posts and struts complete all as specified & directed. |
| 10 | M&L for Reinforced cement concrete M-25 Grade using of 20 mm graded stone aggregate for Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified & directed. |
| 11 | M&L for Reinforced cement concrete M-25 Grade using of 20 mm graded stone aggregate for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed. |
| 12 | M&L for 10 mm dia and over TMT bar cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends binding with MS wire n.exc 0.9mm or with securing clips etc. complete all as specified & directed. |
| 13 | M&L for 6 to 8 mm dia TMT bar cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends binding with MS wire n.exc 0.9mm or with securing clips etc complete all as specified & directed. |
| 14 | M & L brick work using sub class \"B\" bricks curved or straight in plan exc 6 mtr mean radius in CM (1:6) complete all as specified & directed. |
| 15 | Earth filling under floorsin layers n exc 25 cm thick spreading & levelling including well ramming complete all as specified and directed. |
| 16 | M & L for hard core broken stone or builders of gauge not exceeding 63mm, deposited, spread and leveled in layer not exceeding 20 cm thick, watered and rammed to a true surface completeall as specifiedand directed. |
| 17 | M&LWalling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 completeall as specifiedand directed. |
| 18 | M&L for 75mm thick pcc 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection/flooring,surface finished even and smooth without using extra cement, laid in panels n exc 3mtr long and joints shall be filled with the mixture of bitumen and sand in (1:3) by weight complete all as specified and directed. |
| 19 | M&L 15 mm thick rendering in cm 1:4 on brick surfaces finished even and smooth without using extra cement incl mixing of WPC completeall as specifiedand directed. |
| 20 | M&L for Rendering 10mm thick CM 1:6 on fair faces of brick work or concrete sur faces finished even and smooth using extra cement complete all as specified and directed. |
| 21 | M&L 10 mm thick rendering in cm 1:3 on on ceiling surfaces finished even and smooth without using extra cement completeall as specifiedand directed. |
| 22 | Supply only liquid water proofing compound |
| 23 | M&L fornew surface of ceiling by scrapping and washing including preparation of surface by applying three coat of white washing completeall as specifiedand directed. |
| 24 | M&L for preperation of new plastered surfaces and applying two coats of oil bound distemper on walls over a coat of 3 mm thick wall care putty completeall as specifiedand directed. |
| 25 | M & L for two coats of pastic emulsion exterior paint inover a coat of primer completeall as specifiedand directed. |
| 26 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurrymmixed with pigment to match the shade of the slab including rubbing and polishing complete with 15mm thick screed bed or bedding layar of mortar for laying floor finishes in CM 1:3 complete all as specified and directed. |
| 27 | 5M&L Machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screedbase laid and joined with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and including10mm thick rendering to wall tiles in CM 1:6 completeall as specifiedand directed. |
| 28 | S&F First class hard wood 30mm Glazed and skeleton shutters, openrebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters completeall as specifiedand directed. |
| 29 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples completeall as specifiedand directed. |
| 30 | S&F aluminium anodised frame for doors, windows,partitions powder coated (min thickness 50 microns) completeall as specifiedand directed. |
| 31 | S&F Aluminium anodised powder coated window shutter or partition, fixed type without sash bar, alumn section section weighing 0.55 kg per mtr incl necessary joining cleats, glazing clips, rubberpacking, anodised aluminium snap beading, screws etccompleteall as specifiedand directed. |
| 32 | S&F tinted glass pane 5.5mm thick area of each pane exc 0.5 sqm fixed with beads and metal clips/pins completeall as specifiedand directed. |
| 33 | S&F Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides one face is covered with decorative face vaneer with lipping/frame to match completeall as specifiedand directed. |
| 34 | S & F 150mm Extruded aluminium alloy handles, fabricated type, anodised completeall as specifiedand directed. |
| 35 | Aluminium alloy, anodised,300mmsliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminiumalloy and fixed completeall as specifiedand directed. |
| 36 | S & F 100mm stainless steelbutt hinges medium weightcompleteall as specifiedand directed. |
| 37 | S & Faluminium anodised barrel tower bolts of extruded section 150 mm long complete all as specified and directed. |
| 38 | S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 completeall as specifiedand directed. |
| 39 | M&LMachine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Gradecompleteall as specifiedand directed. |
| 40 | M&L for 75mm thick cement concrete type D2 1:4:8(40mm graded stone agg) as in sub base vof flooring completeall as specifiedand directed. |
| 41 | M&L Sand filling under floors or in foundations including watering and consolidation completeall as specifiedand directed. |
| 42 | M&L Preparetion of new surfaces of any description, over 10cm in width or girth, and applying two coat of synthetic enamel paint over one coat of red oxide completeall as specifiedand directed. |
| 43 | M&L for concealed point wiring for one light/ceiling point controlled by one way switch 5/6 amps including cutting and chasing on wall / roof surfacecontrolled by one switch with 1.50 Sqmm (nominal area) FRLS, PVC insulated 1100 volts grade multi stranded copper conductor single core unsheathed cableandFRLS, ISI marked, PVC insulated 1100 volts grade multi stranded copper conductor single core of size 1.50 Sqmm as earth continuity conductor connected to common earth dolly, not less than 1.50mm thick, drawn through in and including rigid PVCconduit (Medium Grade) of suitable size, with all fittings, ISImarked and accessories, the pipe shall be fixed with clamping and shadle including provision of mild steelterminal boxes/Sunken boxes of suitable size made with 1.60 mm thick mild steel sheet recessed/concealed in wall with a coat of black bituminus paint and providing of modular cover plate , suitable for fixing of modular switches / sockets / regulators etc.fixed in recess/concealed of wall making good to the disturbed surface and matching the existing finish complete all as specified and directed. |
| 44 | Description all as per BoQ srl item No 43.00 here-in-before but one ceiling fan/Exhaust fan point controlled by one way switch 5/6 amps. |
| 45 | Description all as per BoQ srl item No 43.00 here-in-before but one socket out let 5/6 amps point on the independent board |
| 46 | Description all as per BoQ srl item No 43.00 here-in-before butone socket out let 5/6 amps point on the same board |
| 47 | Description all as per BoQ srl item No 43.00 here-in-before but wiring with 2.5 sq mm single coremultistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed |
| 48 | S&F of Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. |
| 49 | S&F of Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. |
| 50 | S&F of Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and as directed. |
| 51 | S&F of Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and as directed. |
| 52 | S & Flamp holder, insulated body, with back plate suitable for batten/anglefittings complete all as specified and directed. |
| 53 | S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed. |
| 54 | S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified. |
| 55 | Supply and fixing Wallfan complete accessories, 230 V, 400 mm sweep, 125W, copper binded, controlled with remote and manually complte all as specified and directed |
| 56 | S & F of MCB, DB Vertical TPN, 415 volts 4 ways , DOUBLE DOOR, IP-43, with MCCB Incomer, metal door, rated bus bars, earth bar, neutral links complete incl. blanking plates as required & fixed flush to wall/other surface complete all as specified and as directed. |
| 57 | S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA allcomplete with and including taking down old unsv one complete all as specified and as directed. |
| 58 | S&F MCB, Single pole, 5 to32 amps, 240 volts, ‘C’ curve, 10 KAall complete with and including taking down old unsv one complete all as specified and as directed. |
| 59 | Materialand labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits &making good to walls, floors etc complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE: Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles |
| 60 | S&F MCCB, TPN, 25Amp, 240 volts, 10KA complete as specified and as directed. |
| 61 | S&F Switch piano, flush type, single pole, one way, 6 Amp complete as specified and as directed. |
| 62 | Supply, laying, jointing & testing in trenches or passing through pipe or saddling with wall , 1100 volts grade, XLPE insulatedPVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 25 sqmm 3.5 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. |
| 63 | M&L for 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed. |
| 64 | Excavation in post holes or similar in soft/disintegrated rock each n exc 0.50 cu. m getting out,returningfilling in and ramming earth or broken rubble mixed with earth around in layer not exc 25 cm watering and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed. |
| 65 | M&L providing ,cement concrete in roof kerbs or mud stops, rounded or chamferd on edges,in lintels upto 1.5m clearspan,cills,steps,seismic and other similker bands ,plinths,courses,string courses,lacing courses,parapets and railing up to 60cm in height ,coping kneelers,apex stones,bed,plates,kerbs not provided for in item,waterthrouygh and the like including weathering,slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 66 | Supply and fixing aluminium composite panel (ACP design) sheet 3mm thick any colour fixing with MS pipe on wall nut and bolt and necessary fixing arrangement any height including various alphabets etc. complete all as specified and directed. |
| 67 | S&F joist channel angle, tee sections, MS pipe, MS square tube ,bars , MS plate fixed in purlin rafter cleat, support etc incl welding, riveting etc conf to Fe-410-W Gde E-250 quality-A complete all as specified and directed. |
| 68 | M&L preparation of new cement plastered surfaces over 10 cm in width or girth and applyingtwo coat of synthetic enamel paintovera one coat of primer complete all as specified and directed. |
| 69 | M&L preparation of newsteel/ iron surfaces over 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as certified and directed |